1.
J Chromatogr Sci ; 58(2): 117-126, 2020 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-31950982

RESUMEN

One major challenge in quantifying drugs in biological matrices is to manage interfering compounds. A technique such liquid chromatography coupled to mass spectrometry in tandem (LC-MS/MS) is especially suitable for this application due to its high sensitivity and selectivity in detecting low concentrations of analytes in a complex system. Due to the complexity of LC-MS/MS systems, a number of experimental parameters must be optimized to provide an adequate separation and detection of the analyte. In the present work, a design of experiments approach was developed to optimize an LC-MS/MS-based bioanalytical method to extract olanzapine (OLZ) and quetiapine (QTP) from human plasma. Three steps for the optimization process were conducted: central composite face-centered design to optimize chromatographic parameters (Step 1), ionization in mass spectrometry (Step 2) and a full 32 factorial design to optimize analyte extraction conditions (Step 3). After the optimization process, resolutions and QTP and OLZ retention time (2.3 and 4, respectively) were optimum with pH of 4.7 and 85.5% of acetonitrile for the chromatographic step. Mass spectrometry optimization step provided an increase of (±50%) in the average peak area with high signal-to-noise relationship for the analytes studied. The proposed extraction method was 70% more efficient than the initial method for all drugs analyzed.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Olanzapina/sangre , Fumarato de Quetiapina/sangre , Espectrometría de Masas en Tándem/métodos , Antipsicóticos/sangre , Humanos , Plasma/química
2.
Clin Exp Pharmacol Physiol ; 42(3): 305-13, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25491375

RESUMEN

1. A rapid method using liquid chromatography tandem mass spectrometry for the quantification of olanzapine (OLZ) in human plasma was developed and validated. Venlafaxine was used as the internal standard (IS), and the samples were extracted from 400-µL human plasma with methyl tert-butyl ether for liquid-liquid extraction. 2. Chromatography was performed using an ACE C18, 125 × 4.6-mm i.d., 5-µm column. The mobile phase consisted of water with 0.1% formic acid for solvent A and acetonitrile with 0.1% formic acid for solvent B (50 : 50 v/v) in isocratic mode. The flow rate was 1.2 mL/min. The retention times for OLZ and the IS were 0.78 and 1.04 min, respectively. Tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used to detect OLZ and the IS (m/z: 313.1 > 256.1 and 278.1 > 260.2, respectively). 3. No significant matrix effects were observed on OLZ and the IS retention times, and the mean recovery of OLZ was 90.08%. The assay was linear in the concentration range of 1-20 ng/mL (R(2) = 0.9976). The intra- and inter-day precision were < 11.60% and the accuracy was < 1.66%. 4. This validated method was successfully applied to a pharmacokinetic study in which 10-mg OLZ tablets were administered to healthy volunteers and their plasma OLZ levels were monitored over time. The tests showed that the OLZ test and reference drug (Zyprexa(®)) were bioequivalent, as 90% of the confidence intervals were within the 80-125% interval proposed by regulatory agencies.


Asunto(s)
Benzodiazepinas/sangre , Benzodiazepinas/farmacocinética , Análisis Químico de la Sangre/métodos , Espectrometría de Masas en Tándem , Adolescente , Adulto , Cromatografía Liquida , Estabilidad de Medicamentos , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Olanzapina , Distribución Tisular , Adulto Joven