Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sultan Qaboos Univ Med J ; 22(2): 233-240, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35673290

RESUMEN

Objectives: This study aimed to evaluate the influence of different polymerisation methods of acrylic resin for ocular prostheses on the subcutaneous tissue inflammatory response of rats. Methods: The study was conducted at the Basic Sciences Department, Araçatuba Dental School, São Paulo State University (UNESP), Brazil, from 2016 to 2018. The samples were prepared by water bath (WB), microwave energy (MW) or autopolymerisation (AP) (n = 20 samples per group). The inflammatory response (cell count and immunohistochemical analysis of interleukin [IL]-1ß, IL-6, tumour necrosis factor [TNF]-α, IL-17 and macrophage inflammatory protein-3α) was analysed by the implantation of a sample from each group in the subcutaneous tissue of 20 Wistar rats and evaluated after seven, 15, 30 and 60 days. The quantitative and qualitative data were analysed using analysis of variance and Tukey tests (P <0.05) and visual comparison, respectively. Results: There was a moderate inflammatory infiltrate for the MW and AP groups and a light infiltrate for the WB group after seven days. The inflammatory infiltrate and the immunolabeling of tested targets decreased gradually during the 60-day period. The AP group had the highest immunolabeling of TNF-α (seven days), IL-1ß and IL-17 (at 15 and 30 days) and IL-6 (at 30 and 60 days). The WB and MW groups showed greater immunolabeling at 15 and 30 days, while the MW group also had high results at 60 days. Conclusion: Polymerisation by microwave energy and by chemical activation resulted in a higher inflammatory response.


Asunto(s)
Resinas Acrílicas , Ojo Artificial , Animales , Brasil , Humanos , Interleucina-17 , Interleucina-6 , Ratas , Ratas Wistar , Tejido Subcutáneo
2.
Mater Sci Eng C Mater Biol Appl ; 92: 196-205, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30184742

RESUMEN

The aim of this study was to develop and characterise a new plasma-enhanced chemical vapor deposition (PECVD) film for improving shear bond strength (SBS) between yttria-stabilised tetragonal zirconia (Y-TZP) and veneering ceramic. In total, 192 Y-TZP samples (13 × 5.4 × 5 mm) were divided into 6 groups: control - no treatment (C), airborne-particle abrasion with 27 µm aluminum oxide particles (Al27), 110 µm aluminum oxide particles (Al110), and 250 µm aluminum oxide particles (Al250), application of liner for zirconia (L) and the PECVD film application (P). The Y-TZP surface was characterised by means of Scanning Electronic Microscopy (SEM), Energy-dispersive Spectroscopy (EDS), atomic force microscopy (AFM), surface profilometry and surface-free energy (SFE). SBS between Y-TZP and veneering ceramic was tested before and after thermocycling (20,000 cycles of 5 and 55 °C), and failure mode was also evaluated. Data were analysed by ANOVA and Tukey's HSD test (α = 0.05). Data analysis showed that PECVD film had no effect on surface roughness of Y-TZP (p > 0.05 vs control), whilst the other groups presented higher roughness values (p < 0.05). All treatments increased SFE, except the Al27 group. The highest SBS was presented by the P group (p < 0.05), and values were similar to those of the Al27 group (p = 0.107). Mixed failures were prevalent in all groups, and premature failures were found only in Al groups after thermocycling. Whilst PECVD treatment did not affect Y-TZP surface roughness, high SBS between Y-TZP and the veneering layer was observed. Therefore, PECVD treatment is a promising alternative to improve the performance of bi-layer zirconia-based restorations.


Asunto(s)
Cerámica/química , Coronas con Frente Estético , Gases em Plasma/química , Resistencia al Corte , Circonio/química , Porcelana Dental/química , Propiedades de Superficie , Itrio/química
3.
J Prosthet Dent ; 119(5): 749-754, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-28967406

RESUMEN

STATEMENT OF PROBLEM: Many elderly individuals are rehabilitated with removable complete dentures, which require an initial adaptation period for both oral perception and the perioral muscles. Studies assessing the changes in stimulus perception and the electromyographic (EMG) activity of the orbicularis oris muscle shortly after conventional complete denture insertion are lacking. PURPOSE: The purpose of this clinical study was to evaluate the effect of mouth rehabilitation with removable complete dentures on stimulus perception and the EMG activity of the orbicularis oris muscle. MATERIAL AND METHODS: This study was approved by the Human Research Ethics Committee of the Araçatuba Dental School (São Paulo State University). Fifteen participants who had worn their removable complete dentures for at least 5 years and needed rehabilitation with new prostheses were enrolled in the study. A perception questionnaire was applied, and surface EMG examinations of the orbicularis oris muscle during rest, suction of water with a straw, and pronunciation of the syllables /bah/, /mah/, /pah/, and the word 'Mississippi' were performed before (T0) and 30 (T1) and 100 (T2) days after insertion of the new prostheses. The data were analyzed with the Cochran Q test, McNemar test, 2-way repeated measures ANOVA, and honestly significant difference (HSD) Tukey test (α=.05). RESULTS: Significant improvement was reported in the perception questionnaire in terms of the oral discomfort sensation in the T2 period. EMG activity decreased during rest and suction after insertion of the new prostheses. A statistical difference between the upper and lower fascicles of the orbicularis oris muscle was detected, with a decrease of EMG activity between the T0 and T1 periods on the lower fascicle, except for when pronouncing the /pah/ syllable. CONCLUSIONS: Mouth rehabilitation with removable complete dentures decreased oral discomfort and, depending on the oral function, decreased or increased EMG activity of the orbicularis oris muscle. In addition, the lower fascicle was more active than the upper fascicle during rest and most functional activities.


Asunto(s)
Dentadura Completa , Electromiografía , Músculos Faciales/fisiología , Rehabilitación Bucal/métodos , Anciano , Anciano de 80 o más Años , Diseño de Dentadura , Expresión Facial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Habla/fisiología , Encuestas y Cuestionarios
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...