Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Mech Behav Biomed Mater ; 143: 105888, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37178636

RESUMEN

Y-TZP/MWCNT-SiO2 nanocomposite was synthesized by co-precipitation and hydrothermal treatment methods. After the characterization of the MWCNT-SiO2 powder, specimens were obtained from the synthesized material Y-TZP/MWCNT-SiO2 by uniaxial pressing for a second characterization and later comparison of its optical and mechanical properties with the conventional Y-TZP. The MWCNT-SiO2 was presented in bundles of carbon nanotubes coated by silica (mean length: 5.10 ± 1.34 µm /D90: 6.9 µm). The composite manufactured was opaque (contrast ratio: 0.9929 ± 0.0012) and had a white color with a slightly difference from the conventional Y-TZP (ΔE00: 4.4 ± 2.2) color. The mechanical properties of Y-TZP/MWCNT-SiO2: vickers hardness (10.14 ± 1.27 GPa; p = 0.25) and fracture toughness (4.98 ± 0.30 MPa m1/2; p = 0.39), showed no significant difference from the conventional Y-TZP (hardness: 8.87 ± 0.89; fracture toughness: 4.98 ± 0.30 MPa m1/2). However, for flexural strength (p = 0.003), a lower value was obtained for Y-TZP/MWCNT-SiO2 (299.4 ± 30.5 MPa) when compared to the control Y-TZP (623.7 ± 108.8 MPa). The manufactured Y-TZP/MWCNT-SiO2 composite presented satisfactory optical properties, however the co-precipitation and hydrothermal treatment methods need to be optimized to avoid the formation of porosities and strong agglomerates, both from Y-TZP particles and MWCNT-SiO2 bundles, which lead to a significant decrease in the material flexural strength.


Asunto(s)
Nanocompuestos , Nanotubos de Carbono , Dióxido de Silicio , Ensayo de Materiales , Circonio , Itrio , Propiedades de Superficie , Materiales Dentales
2.
J Oral Biol Craniofac Res ; 9(2): 183-186, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31211032

RESUMEN

The aim of this study was to evaluate and compare changes in linear distance and inclination of lower incisors and canines and intercanine distance after a 30 months orthodontic treatment with self-ligating appliances. Seven patients were treated orthodontically with a Roth prescription passive self-ligating bracket. To perform the measurements and comparisons, CBCT scans were taken before the start of the orthodontic treatment (T1) and after a period of 30 months treatment (T2). The following measurements were performed: (1) the lower incisors and canines inclination in relation to the mandibular plane, (2) intercanine linear distance in millimeters and (3) linear distance in millimeters of the incisal and apical part of lower anterior teeth to a plane (POGM) passing through pogonion point and perpendicular to the mandibular plane. No significant difference were observed between T1 and T2 for canine inclination (p = 0.835), incisors inclination (p = 0.149), canine incisal distance to POGM (p = 0.423) and incisors incisal distance to POGM (p = 0.966), however canine apical distance (p = 0.049) and incisors apical distance (p = 0.002) to POGM was lower at T1 than at T2. The intercanine distance was significantly lower (p = 0.022) at T1 when compared to T2. The use of passive self-ligating brackets in orthodontic treatment to solve 4 mm tooth crowding were able to produce dental arch expansion by bodily tooth movement.

3.
Gen Dent ; 66(6): 56-59, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30444708

RESUMEN

This pediatric study aimed to assess the masticatory function of patients with anterior open bite through a method that utilizes colorimetric capsules. The sample consisted of 106 patients aged 7-11 years, of whom 51 presented with anterior open bite (experimental group) and 55 presented with normal overbite (control group). The colorimetric capsules used in this evaluation contained basic fuchsin granules, which were used to produce a solution after they were ground during chewing. Each patient was asked to chew 1 capsule for 20 seconds. The absorbance of the obtained solutions was analyzed with a spectrophotometer. Greater masticatory efficiency is directly related to the greater light absorbance of a solution, since light absorbance increases with solution concentration. A nonparametric Wilcoxon test indicated that the solutions obtained from the control group presented significantly greater light absorbance than did those from the experimental group (P < 0.05). Therefore, children with an anterior open bite exhibited less masticatory efficiency than those with a normal overbite.


Asunto(s)
Mordida Abierta/diagnóstico , Cápsulas , Estudios de Casos y Controles , Niño , Colorimetría/métodos , Humanos , Masticación/fisiología , Mordida Abierta/fisiopatología
4.
Int J Dent ; 2017: 5130241, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28713426

RESUMEN

PURPOSE: The objective of this study was to evaluate the computational reconstruction of the articular eminence of the temporomandibular joint (TMJ) based on magnetic resonance imaging (MRI) and semiautomatic volumetric segmentation techniques for morphological classification of the TMJ structure. MATERIALS AND METHODS: A total of 36 MRI scans of TMJ individuals were selected and formatted by using the ITK-SNAP software, consisting of MRI segmentation and generation of 3D models. The TMJ articular eminences were also classified according to the morphology analysis of the articular eminence in 3D reconstructions. Two independent trained and calibrated investigators performed the image analysis, which was repeated after thirty days. RESULTS: There was no association between sex and eminence shape (p = 0.456). Fisher's test revealed no statistically significant association between disc classification and eminence shape on both sides (p = 0.629). Chi-square test showed a significant statistically association between disc classification and disc displacement (p = 0.000). Intra- and interrater correlation coefficients showed excellent reproducibility values. CONCLUSIONS: Anatomical variability of the sample investigated was found, with predominantly round shape and presence of correlation between this shape and normal disc position. The correlation of flattened and convex shapes with disc position reduction indicated that type of disc derangement is more prevalent.

5.
Dent Mater ; 30(11): e283-8, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24950806

RESUMEN

OBJECTIVES: The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw. METHODS: Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured. RESULTS: FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region. SIGNIFICANCE: In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment.


Asunto(s)
Pilares Dentales , Análisis de Elementos Finitos , Humanos
6.
Gen Dent ; 60(1): e13-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22313987

RESUMEN

This article presents a prototype of an intraoral device that facilitates preparation of parallel guide planes with accuracy and minimal occlusal divergence. The design of this device facilitates transfer of the desired path of insertion from the diagnostic cast to the mouth quickly and efficiently.


Asunto(s)
Oclusión Dental , Diseño de Dentadura/instrumentación , Dentadura Parcial Removible , Pilares Dentales , Humanos , Ajuste de Prótesis/instrumentación , Preparación Protodóncica del Diente/instrumentación
7.
J Adhes Dent ; 14(1): 47-50, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21734978

RESUMEN

PURPOSE: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber. MATERIALS AND METHODS: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%). RESULTS: Group A2 (97.9 ± 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength. CONCLUSION: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo , Materiales Dentales/química , Dentadura Parcial Fija , Vidrio/química , Análisis del Estrés Dental/instrumentación , Diseño de Dentadura , Humanos , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Docilidad , Estrés Mecánico , Propiedades de Superficie
8.
Eur J Prosthodont Restor Dent ; 18(3): 107-10, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21077418

RESUMEN

The objective of this study was to evaluate the flexural strength of denture base resin reinforced with glass fibers and with a laboratorial composite resin. Group G1 was formed with specimens made of acrylic resin. Group G2 was formed with the same acrylic resin but reinforced with a glass-fiber system, and G3 was reinforced with the composite resin. A flexural strength test was performed in all groups (n=10). The mean value for the G1 was 86.70 MPa +/- 6.48, for G2 it was 86.60 MPa +/- 15.01 and for G3 it was 108.90 + 11.03. The addition of glass fiber did not increase the flexural strength however the use of a resin-based composite produced significant reinforcement.


Asunto(s)
Resinas Acrílicas/química , Análisis del Estrés Dental , Bases para Dentadura , Análisis de Varianza , Resinas Compuestas , Vidrio , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Docilidad , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA