Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 30(6): 3083-3093, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32065282

RESUMEN

PURPOSE: To compare 3D T1-weighted fast spin echo (FSE) and 3D T1-weighted gradient echo (GE) mDixon as morphologic sequences to complement diffusion-weighted imaging (DWI) for the metastatic screening in prostate cancer (PCa) patients. MATERIALS AND METHODS: Thirty PCa patients at high risk of metastases prospectively underwent both a 3D T1 FSE (14 min) and a rapid 3D T1 GEmDixon (1 min 20 s) sequences within a WB-MRI protocol. Two readers assessed the diagnostic performance of the FSE/Fat/in-phase (IP)/IP+Fat sequences in detecting bone and node metastases. The reference standard was established by a panel of four physicians on the basis of all baseline and follow-up imaging, biological and clinical information. The reproducibility of readings, predictive accuracy (Acc) from ROC curves analysis, and contrast-to-reference ratio (CRR) in lesions were assessed for each sequence. RESULTS: In bone and lymph nodes (per-region analysis), reproducibility was at least good for all sequences/readers, except for nodes in the common iliac/inguinal regions. In bone (per-organ analysis), Acc of FSE was superior to that of mDixon (difference + 4%, p < 0.0083). In nodes (per-organ analysis), Acc of Fat was superior to that of other sequences (difference + 4% to + 6% depending on reader, p < 0.0083). In the per-patient analysis, Acc of FSE was superior to that of mDixon (difference + 4% to + 6% depending on sequence, p < 0.0083). Fat images had higher CRR compared with FSE in the thoracic spine, the bony pelvis and lymph node metastases (p < 0.025). CONCLUSION: 3D T1 GEmDixon may replace 3D T1 FSE to complement DWI in WB-MRI for metastatic screening in PCa. It demonstrates an Acc ranging from + 4% to + 6% (nodes) to - 4% to - 6% (bone and patient staging) compared with FSE and considerably reduces the examination time, offering the perspective of acquiring WB-MRI examinations in less than 20 min. KEY POINTS: • The replacement of 3D T1 FSE by the 3D T1 GE mDixon as morphologic sequence to complement DWI drastically reduces the acquisition time of WB-MRI studies. • The 3D T1 GE mDixon sequence offers similar reproducibility of image readings compared with that of the 3D T1 FSE. • Differences in diagnostic accuracy are limited (+ 4%/+ 6% in favor of mDixon to detect node metastases; + 4%/+ 6% in favor of FSE to detect bone metastases/metastatic disease in a patient).


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Detección Precoz del Cáncer/métodos , Neoplasias de la Próstata/diagnóstico , Imagen de Cuerpo Entero/métodos , Anciano , Anciano de 80 o más Años , Humanos , Metástasis Linfática , Masculino , Persona de Mediana Edad , Neoplasias de la Próstata/secundario , Reproducibilidad de los Resultados
2.
J Cereb Blood Flow Metab ; 33(9): 1314-21, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23778162

RESUMEN

Venous dysfunction has recently been hypothesized to contribute to the pathophysiology of multiple sclerosis (MS). 2D phase-contrast (PC) magnetic resonance imaging (MRI) is a non-invasive and innocuous technique enabling reliable quantification of cerebrospinal fluid (CSF) and blood flows in the same imaging session. We compared PC-MRI measurements of CSF, arterial and venous flows in MS patients to those from a normative cohort of healthy controls (HC). Nineteen MS patients underwent a standardized MR protocol for cerebral examination on a 3T system including Fast cine PC-MRI sequences with peripheral gating in four acquisition planes. Quantitative data were processed using a homemade software to extract CSF and blood flow regions of interest, animate flows, and calculate cervical and intracranial vascular flow curves during the cardiac cycle (CC). Results were compared with values obtained in 21 HC using multivariate analysis. Venous flow patterns were comparable in both groups without signs of reflux. Arterial flows (P=0.02) and cervical CSF dynamic oscillations (P=0.01) were decreased in MS patients. No significant differences in venous cerebral and cervical outflows were observed between groups, thereby contradicting the recently proposed theory of venous insufficiency. Unexpected decrease in arterial perfusion in MS patients warrants further correlation to volumetric measurements of the brain.


Asunto(s)
Circulación Cerebrovascular , Esclerosis Múltiple/fisiopatología , Adulto , Arterias/fisiopatología , Velocidad del Flujo Sanguíneo , Líquido Cefalorraquídeo/diagnóstico por imagen , Estudios de Cohortes , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Radiografía , Venas/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA