Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
1.
Eur Heart J Imaging Methods Pract ; 2(1): qyae017, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39045178

RESUMEN

Tricuspid regurgitation (TR) carries an unfavourable prognosis and often leads to progressive right ventricular (RV) failure. Secondary TR accounts for over 90% of cases and is caused by RV and/or tricuspid annulus dilation, in the setting of left heart disease or pulmonary hypertension. Surgical treatment for isolated TR entails a high operative risk and is seldom performed. Recently, transcatheter edge-to-edge repair (TEER) has emerged as a low-risk alternative treatment in selected patients. Although the experience gained from mitral TEER has paved the way for the technique's adaptation to the tricuspid valve (TV), its anatomical complexity necessitates precise imaging. To this end, a comprehensive protocol integrating 2D and 3D imaging from both transthoracic echocardiography (TTE) and transoesophageal echocardiography (TOE) plays a crucial role. TTE allows for an initial morphological assessment of the TV, quantification of TR severity, evaluation of biventricular function, and non-invasive haemodynamic evaluation of pulmonary circulation. TOE, conversely, provides a detailed evaluation of TV morphology, enabling precise assessment of TR mechanism and severity, and represents the primary method for determining eligibility for TEER. Once a patient is considered eligible for TEER, TOE, alongside fluoroscopy, will guide the procedure in the catheterization lab. High-quality TOE imaging is crucial for patient selection and to achieve procedural success. The present review examines the roles of TTE and TOE in managing patients with severe TR eligible for TEER, proposing the step-by-step protocol successfully adopted in our centre.

2.
Clin Res Cardiol ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046472

RESUMEN

BACKGROUND: To assess the interaction between heart failure (HF) severity and optimal reduction of secondary mitral regurgitation (SMR) on mortality in patients undergoing transcatheter edge-to-edge repair (M-TEER). METHODS AND RESULTS: Among 1656 patients included in the Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) 984 had SMR and complete data on advanced HF. Advanced HF was defined as NYHA class III or IV, left ventricular ejection fraction ≤ 30%, and > 1 HF hospitalization during the last 12 months. Optimal M-TEER was defined as residual SMR ≤ 1 + at discharge. One hundred sixteen patients (11.8%) had advanced HF. Achievement of an optimal SMR reduction was similar in patients with and without advanced HF (65% and 60% respectively). Advanced HF was an independent predictor of 2-year all-cause death (adjusted HR 1.52, 95% CI 1.09-2.10). Optimal M-TEER, as compared to a no-optimal M-TEER, was associated with a reduced risk of death both in patients with advanced (HR 0.55, 95% CI 0.32-0.97; p = 0.039) and no-advanced HF (HR 0.59, 95% CI 0.46-0.78; p < 0.001; p = 0.778 for interaction). CONCLUSIONS: Advanced HF is associated with poor outcome in patients undergoing M-TEER. However, an optimal SMR reduction reduces the risk of 2-year mortality regardless of HF severity.

3.
JACC Cardiovasc Interv ; 17(12): 1455-1466, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38925749

RESUMEN

BACKGROUND: Right ventricular impairment is common among patients undergoing transcatheter edge-to-edge repair for secondary mitral regurgitation (SMR). Adherence to guideline-directed medical therapy (GDMT) for heart failure is poor in these patients. OBJECTIVES: The aim of this study was to evaluate the impact of GDMT on long-term survival in this patient cohort. METHODS: Within the EuroSMR (European Registry of Transcatheter Repair for Secondary Mitral Regurgitation) international registry, we selected patients with SMR and right ventricular impairment (tricuspid annular plane systolic excursion ≤17 mm and/or echocardiographic right ventricular-to-pulmonary artery coupling <0.40 mm/mm Hg). Titrated guideline-directed medical therapy (GDMTtit) was defined as a coprescription of 3 drug classes with at least one-half of the target dose at the latest follow-up. The primary outcome was all-cause mortality at 6 years. RESULTS: Among 1,213 patients with SMR and right ventricular impairment, 852 had complete data on medical therapy. The 123 patients who were on GDMTtit showed a significantly higher long-term survival vs the 729 patients not on GDMTtit (61.8% vs 36.0%; P < 0.00001). Propensity score-matched analysis confirmed a significant association between GDMTtit and higher survival (61.0% vs 43.1%; P = 0.018). GDMTtit was an independent predictor of all-cause mortality (HR: 0.61; 95% CI: 0.39-0.93; P = 0.02 for patients on GDMTtit vs those not on GDMTtit). Its association with better outcomes was confirmed among all subgroups analyzed. CONCLUSIONS: In patients with right ventricular impairment undergoing transcatheter edge-to-edge repair for SMR, titration of GDMT to at least one-half of the target dose is associated with a 40% lower risk of all-cause death up to 6 years and should be pursued independent of comorbidities.


Asunto(s)
Cateterismo Cardíaco , Fármacos Cardiovasculares , Adhesión a Directriz , Insuficiencia de la Válvula Mitral , Guías de Práctica Clínica como Asunto , Sistema de Registros , Disfunción Ventricular Derecha , Función Ventricular Derecha , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Anciano , Resultado del Tratamiento , Factores de Tiempo , Disfunción Ventricular Derecha/fisiopatología , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/terapia , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Fármacos Cardiovasculares/uso terapéutico , Fármacos Cardiovasculares/efectos adversos , Europa (Continente) , Anciano de 80 o más Años , Medición de Riesgo , Ecocardiografía Transesofágica , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Persona de Mediana Edad , Recuperación de la Función
4.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios Retrospectivos
7.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38410954

RESUMEN

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Pronóstico , Ecocardiografía de Estrés/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Gasto Cardíaco , Insuficiencia Cardíaca/complicaciones , Oxígeno
9.
Catheter Cardiovasc Interv ; 103(1): 209-218, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37957842

RESUMEN

BACKGROUND: Balloon post-dilation (BPD) is a widely adopted strategy to optimize acute results of TAVI, with a positive impact on both paravalvular leak and mean gradients. On the other hand, the inflation of the balloon inside prosthetic leaflets may damage them increasing the risk of structural valve deterioration (SVD). Furthermore, the impact of BPD on long-term clinical outcomes and valve hemodynamics is yet unknown. AIMS: To evaluate the impact of BPD on valve durability and long-term clinical outcomes in patients undergoing self-expanding transcatheter valve implantation (TAVI). METHODS: Echocardiographic and clinical data from the ClinicalService (a nation-based data repository and medical care project) were analyzed. Patients were divided into two groups, those who underwent BPD after TAVI and those who did not. Coprimary endpoints were all-cause death and SVD. Cumulative incidence functions for SVD were estimated. RESULTS: Among 1835 patients included in the study, 417 (22.7%) underwent BPD and 1418 (77.3%) did not undergo BPD. No statistically significant differences at 6-year follow-up were found between groups in terms of all-cause mortality (HR: 1.05, 95% CI: 0.9-1.22; p = 0.557) and SVD (2.1% vs. 1.4%, p = 0.381). In addition, BPD did not predispose to higher risk of cardiovascular death, myocardial infarction, valve thrombosis, and endocarditis at 6-year follow-up. CONCLUSIONS: BPD following TAVI with a self-expanding prosthesis does not seem to be associated with an increased risk of adverse clinical outcomes or SVD at 6-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Dilatación , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Diseño de Prótesis
10.
Am J Cardiol ; 212: 118-126, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38036051

RESUMEN

Given the expanding indications toward younger patients at lower surgical risk, transcatheter aortic valve replacement (TAVR) simplification and streamlining are gaining increasing importance. Patients who underwent TAVR from the year 2015 to 2020 were prospectively enrolled. The patients were divided in time tertiles according to the date of intervention. Data on preprocedural planning, including coronary computed tomography angiography (CCTA), procedures, and outcomes, were compared between the time tertiles. A total of 771 consecutive patients from a single institution were enrolled. We observed a trend toward the use of a fully percutaneous versus surgical approach for the index access, left radial artery versus contralateral femoral artery for the secondary access, and left ventricular pacing on the stiff guidewire versus right ventricular pacing. Immediate device success significantly increased, whereas the length of hospital stay decreased. Overall, approximately 60% of the total study population underwent CCTA instead of coronary angiography, with no adverse events. One-year survival rates significantly improved over time. A simplified TAVR approach was associated with better survival, whereas low baseline functional capacity, preexisting coronary artery disease, renal impairment, periprocedural blood transfusions, and paravalvular leak were related to worse outcomes. In conclusion, our study showed a constant tendency to procedure streamlining and improve procedural success and 1-year outcomes. A strategy based on CCTA allows sparing safely almost half of the preoperative invasive coronary angiography.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Angiografía Coronaria , Estudios Retrospectivos
11.
Medicina (Kaunas) ; 59(10)2023 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-37893422

RESUMEN

Background: We evaluated the bio-humoral and non-invasive haemodynamic correlates of renal congestion evaluated by Doppler renal venous flow (RVF) across the heart failure (HF) spectrum, from asymptomatic subjects with cardiovascular risk factors (Stage A) and structural heart disease (Stage B) to patients with clinically overt HF (Stage C). Methods: Ultrasound evaluation, including echocardiography, lung ultrasound and RVF, along with blood and urine sampling, was performed in 304 patients. Results: Continuous RVF was observed in 230 patients (76%), while discontinuous RVF (dRVF) was observed in 74 (24%): 39 patients had pulsatile RVF, 18 had biphasic RVF and 17 had monophasic RVF. Stage C HF was significantly more common among patients with dRVF. Monophasic RVF was associated with worse renal function and a higher urinary albumin-to-creatinine ratio (uACR). After adjusting for hypertension, diabetes mellitus, the presence of Stage C HF and serum creatinine levels, worsening RVF patterns were associated with higher NT-proBNP levels, worse right ventricular-arterial coupling, larger inferior vena cava and higher echo-derived pulmonary artery wedge pressure. This trend was confirmed when only patients with HF Stage C were analysed after adjusting for the left ventricle ejection fraction (LVEF). Conclusion: Abnormal RVF is common across the HF spectrum. Worsening RVF patterns are independently associated with increased congestion, worse non-invasive haemodynamics and impaired RV-arterial coupling. RVF evaluation could refine prognostic stratification across the HF spectrum, irrespective of LVEF.


Asunto(s)
Insuficiencia Cardíaca , Disfunción Ventricular Derecha , Humanos , Hemodinámica , Ecocardiografía , Función Ventricular Izquierda , Riñón/fisiología , Disfunción Ventricular Derecha/etiología
12.
G Ital Cardiol (Rome) ; 24(10 Suppl 2): 37S-41S, 2023 10.
Artículo en Italiano | MEDLINE | ID: mdl-37767846

RESUMEN

Acute coronary syndromes typically result from the formation of atherosclerotic lesions in a large epicardial vessel, which restrict blood flow either partially or completely. These lesions can be identified through angiography, an invasive imaging technique that enables visualization of the coronary arteries. However, a small percentage of patients, usually ranging from 5% to 10%, experience symptoms and/or signs of myocardial ischemia, either acute or chronic, without significant obstructive coronary lesions visible on angiography. This condition is particularly prevalent in young women and is characterized by two distinct forms: myocardial infarction with no obstructive coronary arteries (MINOCA) and myocardial ischemia with no obstructive coronary arteries (INOCA). MINOCA can be caused by a variety of heterogeneous mechanisms, including coronary vascular spasm, microvascular disease, spontaneous coronary dissection, and plaque rupture or erosion. Conversely, coronary vasospasm and microvascular dysfunction account for the majority of patients with INOCA. We here present three cases of MINOCA/INOCA that were evaluated using optical coherence tomography, coronary flow reserve, index of microcirculatory resistance, and acetylcholine provocative test. These diagnostic tests allowed us to identify a specific condition and adopt a targeted treatment for each patient.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Isquemia Miocárdica , Humanos , Femenino , Vasos Coronarios/diagnóstico por imagen , Microcirculación , MINOCA , Angiografía Coronaria , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Isquemia Miocárdica/complicaciones
13.
Eur J Heart Fail ; 25(11): 1947-1958, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37655676

RESUMEN

AIMS: Degenerative aortic valve stenosis with preserved ejection fraction (ASpEF) and heart failure with preserved ejection fraction (HFpEF) display intriguing similarities. This study aimed to provide a non-invasive, comparative analysis of ASpEF versus HFpEF at rest and during exercise. METHODS AND RESULTS: We prospectively enrolled 148 patients with HFpEF and 150 patients with degenerative moderate-to-severe ASpEF, together with 66 age- and sex-matched healthy controls. All subjects received a comprehensive evaluation at rest and 351/364 (96%) performed a combined cardiopulmonary exercise stress echocardiography test. Patients with ASpEF eligible for transcatheter aortic valve replacement (n = 125) also performed cardiac computed tomography (CT). HFpEF and ASpEF patients showed similar demographic distribution and biohumoral profiles. Most patients with ASpEF (134/150, 89%) had severe high-gradient aortic stenosis; 6/150 (4%) had normal-flow, low-gradient ASpEF, while 10/150 (7%) had low-flow, low-gradient ASpEF. Both patient groups displayed significantly lower peak oxygen consumption (VO2 ), peak cardiac output, and peak arteriovenous oxygen difference compared to controls (all p < 0.01). ASpEF patients showed several extravalvular abnormalities at rest and during exercise, similar to HFpEF (all p < 0.01 vs. controls). Epicardial adipose tissue (EAT) thickness was significantly greater in ASpEF than HFpEF and was inversely correlated with peak VO2 in all groups. In ASpEF, EAT was directly related to echocardiography-derived disease severity and CT-derived aortic valve calcium burden. CONCLUSION: Functional capacity is similarly impaired in ASpEF and HFpEF due to both peripheral and central components. Further investigation is warranted to determine whether extravalvular alterations may affect disease progression and prognosis in ASpEF even after valve intervention, which could support the concept of ASpEF as a specific sub-phenotype of HFpEF.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Humanos , Volumen Sistólico , Consumo de Oxígeno , Hemodinámica , Prueba de Esfuerzo/métodos , Estenosis de la Válvula Aórtica/cirugía , Fenotipo , Tolerancia al Ejercicio , Función Ventricular Izquierda
14.
Am J Cardiol ; 205: 241-248, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37611417

RESUMEN

Symptoms of aortic stenosis (AS) are not proportional to its severity and patients with very severe AS (VSAS) remain asymptomatic for a long time. The appropriate time for intervention in patients with VSAS and the effects of transcatheter aortic valve implantation (TAVI) on left ventricular hypertrophy (LVH) remain debated. Our aim was to compare the procedural and 30-day outcomes of TAVI between patients with VSAS and patients with severe AS (SAS) and the changes in LVH. We selected patients with an aortic peak velocity ≥5 m/s (VSAS) and those with aortic peak velocity 4 to 5 m/s (SAS) treated with TAVI. Patients with reduced left ventricular ejection fraction (<45%) were excluded. The primary end point was the incidence of all-cause death at 30 days. The secondary end points included the 30-day incidence of cardiac death, cardiac rehospitalization, and stroke/transient ischemic attack and the changes in LVH from baseline to 30 days. A total of 102 patients in the VSAS group and 535 in the SAS group were included. Patients in the VSAS group had a thicker septal wall (p <0.001) and a higher Agaston score (p <0.001) and calcium volume (p = 0.007). No differences were observed regarding the primary and secondary clinical end points. However, patients with VSAS showed a significantly greater improvement in concentric LVH, although the prevalence of concentric LVH remained higher than in patients with SAS. TAVI in patients with VSAS showed similar procedural and clinical outcomes to patients with SAS and experienced a more pronounced improvement in the prevalence of concentric LVH.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Volumen Sistólico , Función Ventricular Izquierda , Hipertrofia Ventricular Izquierda , Estenosis de la Válvula Aórtica/cirugía
16.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
17.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858659

RESUMEN

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Asunto(s)
Ataque Isquémico Transitorio , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Sistema de Registros
18.
J Clin Med ; 12(3)2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36769421

RESUMEN

BACKGROUND: We investigated the role of the dynamic changes of pulmonary congestion, as assessed by sonographic B-lines, as a tool to stratify prognosis in patients admitted for acute heart failure with reduced and preserved ejection fraction (HFrEF, HFpEF). METHODS: In this multicenter, prospective study, lung ultrasound was performed at admission and before discharge by trained investigators, blinded to clinical findings. RESULTS: We enrolled 208 consecutive patients (mean age 76 [95% confidence interval, 70-84] years), 125 with HFrEF, 83 with HFpEF (mean ejection fraction 32% and 57%, respectively). The primary composite endpoint of cardiovascular death or HF re-hospitalization occurred in 18% of patients within 6 months. In the overall population, independent predictors of the occurrence of the primary endpoint were the number of B-lines at discharge, NT-proBNP levels, moderate-to-severe mitral regurgitation, and inferior vena cava diameter on admission. B-lines at discharge were the only independent predictor in both HFrEF and HFpEF subgroups. A cut-off of B-lines > 15 at discharge displayed the highest accuracy in predicting the primary endpoint (AUC = 0.80, p < 0.0001). Halving B-lines during hospitalization further improved event classification (continuous net reclassification improvement = 22.8%, p = 0.04). CONCLUSIONS: The presence of residual subclinical sonographic pulmonary congestion at discharge predicts 6-month clinical outcomes across the whole spectrum of acute HF patients, independent of conventional biohumoral and echocardiographic parameters. Achieving effective pulmonary decongestion during hospitalization is associated with better outcomes.

19.
Europace ; 25(3): 1116-1125, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36691737

RESUMEN

AIMS: Permanent pacemaker implantation (PPM-I) remains nowadays the most important drawback of transcatheter aortic valve replacement (TAVR) procedure and the optimal strategy of delayed conduction disturbances (CDs) in these patients is unclear. The study aimed to validate an ambulatory electrocardiogram (ECG) monitoring through a 30 s spot ambulatory digital mobile ECG (AeECG), by using KardiaMobile-6L device in a 30-day period after TAVR procedure. METHODS AND RESULTS: Between March 2021 and February 2022, we consecutively enrolled all patients undergoing TAVR procedure, except pacemaker (PM) carriers. At discharge, all patients were provided of a KardiaMobile-6L device and a spot digital ECG (eECG) recording 1 month schedule. Clinical and follow-up data were collected, and eECG schedule compliance and recording quality were explored. Among 151 patients without pre-existing PM, 23 were excluded for pre-discharge PPM-I, 18 failed the KardiaMobile-6L training phase, and 10 refused the device. Delayed CDs with a Class I/IIa indication for PPM-I occurred in eight patients (median 6 days). Delayed PPM-I vs. non-delayed PPM-I patients were more likely to have longer PR and QRS intervals at discharge. PR interval at discharge was the only independent predictor for delayed PPM-I at multivariate analysis. The overall eECG schedule compliance was 96.5%. None clinical adverse events CDs related were documented using this new AeECG monitoring modality. CONCLUSION: A strategy of 30 s spot AeECG is safe and efficacious in delayed CDs monitoring after TAVR procedure with a very high eECG schedule level of compliance.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estimulación Cardíaca Artificial/métodos , Resultado del Tratamiento , Factores de Riesgo , Trastorno del Sistema de Conducción Cardíaco/etiología , Electrocardiografía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA