1.
Imaging Sci Dent ; 52(1): 53-60, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35387102

RESUMEN

Purpose: The aim of this study was to compare the fractal dimension (FD) measured at 2 bone sites (second cervical vertebra and mandible) on cone-beam computed tomography (CBCT). The research question was whether FD could serve as an accessory tool to refer postmenopausal women for densitometric analysis. Therefore, the reliability and accuracy of FD were evaluated. Materials and Methods: In total, 103 postmenopausal women were evaluated, of whom 52 had normal bone mineral density and 51 had osteoporosis, according to dual X-ray absorptiometry of the lumbar spine and hip. On the CBCT scans, 2 regions of interest were selected for FD analysis: 1 at the second cervical vertebra and 1 located at the mandible. The correlations between both measurements, intra- and inter-observer agreement, and the accuracy of the measurements were calculated. A P value less than 0.05 was considered to indicate statistical significance for all tests. Results: The mean FD values were significantly lower at the mandibular region of interest in osteoporotic patients than in individuals with normal bone mineral density. The areas under the curve were 0.644 (P=0.008) and 0.531 (P=0.720) for the mandibular and vertebral sites, respectively. Conclusion: FD at the vertebral site could not be used as an adjuvant tool to refer women for osteoporosis investigation. Although FD differed between women with normal BMD and osteoporosis at the mandibular site, it demonstrated low accuracy and reliability.

2.
Clin Oral Investig ; 24(9): 3193-3202, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31912243

RESUMEN

OBJECTIVE: To verify whether mandibular cortical analyses accurately distinguish postmenopausal women with normal bone mineral density (BMD) from women with osteoporosis by means of a cone-beam computed tomography (CBCT)-driven composite osteoporosis index (three-dimensional mandibular osteoporosis index-3D MOI). MATERIAL AND METHODS: The comparison was performed between 52 women with normal BMD and 51 women with osteoporosis according to dual-energy X-ray absorptiometry (DXA) examination of the lumbar spine and hip. Mandibular cortical width (MCW) and cortical quality were evaluated on cross-sectional and panoramic reconstructed images. ANOVA, ROC curves and accuracy measurements were used for statistical analyses, as well as a predictive model combining the quantitative and qualitative analyses and age. RESULTS: All CBCT-driven measurements presented good to moderate intra- and interobserver agreements. MCW values were significantly lower in women with osteoporosis. Postmenopausal women with osteoporosis were 8 times more likely to have the cortex classified as C3, and 2.4 times more likely to have MCW thinner than 2.75 mm. The area under the ROC curve was 0.8 for the predictive model. CONCLUSIONS: The newly developed 3D MOI enables distinguishing women with osteoporosis from those with normal BMD with good sensitivity and specificity. CLINICAL RELEVANCE: Whenever a CBCT scan is performed for specific clinical indications, a 3D MOI may be performed to qualitatively and quantitatively assess the condition of the mandibular cortex. This may be surely helpful to assess the osteoporosis status in the ageing population and more specifically in peri- or postmenopausal women.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Osteoporosis Posmenopáusica , Osteoporosis , Absorciometría de Fotón , Densidad Ósea , Estudios Transversales , Femenino , Humanos , Mandíbula/diagnóstico por imagen , Osteoporosis/diagnóstico por imagen , Osteoporosis Posmenopáusica/diagnóstico por imagen , Radiografía Panorámica