Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 63(23): 235007, 2018 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-30468682

RESUMEN

With more patients receiving external beam radiation therapy with protons, it becomes increasingly important to refine the clinical understanding of the relative biological effectiveness (RBE) for dose delivered during treatment. Treatment planning systems used in clinics typically implement a constant RBE of 1.1 for proton fields irrespective of their highly heterogeneous linear energy transfer (LET). Quality assurance tools that can measure beam characteristics and quantify or be indicative of biological outcomes become necessary in the transition towards more sophisticated RBE weighted treatment planning and for verification of the Monte Carlo and analytical based models they use. In this study the RBE for the CHO-K1 cell line in a passively delivered clinical proton spread out Bragg peak (SOBP) is determined both in vitro and using a silicon-on-insulator (SOI) microdosimetry method paired with the modified microdosimetric kinetic model. The RBE along the central axis of a SOBP with 2 Gy delivered at the middle of the treatment field was found to vary between 1.11-1.98 and the RBE for 10% cell survival between 1.07-1.58 with a 250 kVp x-ray reference radiation and between 1.19-2.34 and 0.95-1.41, respectively, for a Co60 reference. Good agreement was found between RBE values calculated from the SOI-microdosimetry-MKM approach and in vitro. A strong correlation between proton lineal energy and RBE was observed particularly in the distal end and falloff of the SOBP.


Asunto(s)
Terapia de Protones/métodos , Animales , Células CHO , Supervivencia Celular , Cricetinae , Cricetulus , Relación Dosis-Respuesta en la Radiación , Humanos , Transferencia Lineal de Energía , Método de Montecarlo , Terapia de Protones/efectos adversos , Efectividad Biológica Relativa
2.
Radiat Prot Dosimetry ; 182(2): 252-257, 2018 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29669096

RESUMEN

Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.


Asunto(s)
Terapia de Protones , Radiometría/métodos , Humanos , Modelos Anatómicos , Protección Radiológica , Dispersión de Radiación , Sudáfrica
3.
Strahlenther Onkol ; 175 Suppl 2: 10-2, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10394385

RESUMEN

A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.


Asunto(s)
Terapia de Protones , Planificación de la Radioterapia Asistida por Computador , Algoritmos , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Agua
4.
Strahlenther Onkol ; 175 Suppl 2: 30-2, 1999 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10394392

RESUMEN

The 200 MeV cyclotron facility at the National Accelerator Centre has been operational since 1987. Between September 1988 and December 1997 a total of 973 patients (26,916 fields) had been treated on the 66 MeV p+Be isocentric neutron therapy system. Patients are currently being treated according to several protocols, including tumors of the head and neck, salivary gland and breast and soft tissue sarcomas, uterine sarcomas and paranasal sinuses. A multiblade post-collimator trimmer has recently being installed. This device provides improved neutron beam shaping capability. Between September 1993 and December 1997 a total of 243 patients (4008 fields) had been treated (mainly intracranial stereotactic irradiations) on the fixed horizontal 200 MeV proton therapy facility. The facility incorporates an innovative automatic patient positioning system. Two new fixed beam lines for proton therapy are presently being designed (horizontal and 30 degrees to the vertical) for an existing unused treatment vault. Spot scanning systems will be developed for both beam lines.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias/radioterapia , Aceleradores de Partículas , Planificación de la Radioterapia Asistida por Computador , Humanos , Neutrones/uso terapéutico , Fantasmas de Imagen , Terapia de Protones , Sudáfrica
6.
S Afr Med J ; 73(10): 610, 1988 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-3287650

RESUMEN

Three cases of gallstone in children with no apparent predisposing condition are reported. The importance of considering cholelithiasis in the child with abdominal pain is described and the use of ultrasonography in its efficient diagnosis is stressed.


Asunto(s)
Colelitiasis , Adolescente , Niño , Preescolar , Colelitiasis/diagnóstico , Colelitiasis/patología , Humanos , Masculino , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...