Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Am Heart Assoc ; 11(22): e026041, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36346050

RESUMEN

Background In a previous trial, higher 5-year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus-eluting stents (SES). We assessed 5-year safety and efficacy of all-comers as well as patients with diabetes treated with SES or Synergy everolimus-eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus-eluting stents (ZES). Methods and Results The randomized BIO-RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug-Eluting Stents in an All Comers Population) trial enrolled 3514 all-comer patients at 4 Dutch cardiac centers. Patients aged ≥18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five-year follow-up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71-1.12], Plog-rank=0.31; and HR, 0.82 [95% CI, 0.65-1.04], Plog-rank=0.10, respectively). Individual components of target vessel failure showed no significant between-stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent-groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [Plog-rank=0.69 and Plog-rank=0.63]). Conclusions Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5-year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5-year clinical outcomes. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Adolescente , Adulto , Diseño de Prótesis , Resultado del Tratamiento , Everolimus , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Diabetes Mellitus/etiología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA