Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38438087

RESUMEN

BACKGROUND: Lung transplantation is the only curative treatment for patients with end-stage pulmonary fibrosis. It is still under debate whether over- or undersizing of lung allografts is preferably performed regarding the postoperative outcome. We therefore analyzed our data using predicted total lung capacity to compare size mismatches. METHODS: Patient records were retrospectively reviewed. Three groups were formed, 1 including patients with a donor-recipients pTLC ratio (DRPR) of <1.0 (undersized group), the second with a DRPR of ≥1.0 and <1.1 (size-matched group), and the third group with a DRPR of ≥1.1 (oversized group). Outcomes were evaluated using chi-square test and Kruskall-Wallis test as well as Kaplan-Meier analysis, competing risk analysis, and multivariable analysis, respectively. RESULTS: Between January 2010 and May 2023, among the 1501 patients transplanted at our institution, 422 (28%) patients were included, 26 (2%) patients forming the oversized group (median DRPR: 1.14), 101 (7%) patients forming the size-matched group (median DRPR: 1.03), and 296 (20%) patients forming the undersized group (median DRPR: 0.92). Patients from the oversized group had a higher PGD grade 3 rate at 24 (p < 0.001), 48 (p < 0.001), and 72 (p = 0.039) hours after transplantation as well as a higher in-hospital mortality compared to the undersized group (p = 0.033). The long-term survival was also better in the undersized group compared to the oversized group (p = 0.011) and to the size-matched group (p = 0.01). CONCLUSIONS: Oversizing lung allografts more than 10% deteriorated early postoperative outcomes and long-term survival in patients with pulmonary fibrosis.

2.
Eur Heart J Case Rep ; 8(2): ytae035, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38425726

RESUMEN

Background: The introduction of a transapical transcatheter beating heart replacement system has significantly expanded therapeutic options for patients with severely diseased mitral valves, particularly those ineligibles for traditional surgery or transcatheter repair. However, challenges, such as left ventricular outflow tract obstruction (LVOT-O) and the risk of dynamic systolic anterior motion (SAM) in cases with elongated anterior mitral leaflet (AML) post-prosthesis implantation, impede the widespread adoption of transcatheter mitral valve replacement (TMVR). Case summary: In 2022, a 75-year-old male with severe mixed-genesis mitral regurgitation (MR) underwent Carillon Mitral Contour System annuloplasty. Recurrent heart failure admissions (New York Heart Association IV) and prohibitive risk for open-heart surgery (European System for Cardiac Operative Risk Evaluation II 8.27%) prompted evaluation for Tendyne TMVR with the MitraCut technique. This beating heart transapical approach involved scissor-mediated splitting of the elongated 27 mm AML, essential for mitigating LVOT-O risk and dynamic SAM. The screening echocardiogram revealed the poorly tethered AML near the thickened septum at the simulated neo-LVOT site. Discussion: This case underscores the intricate management challenges associated with severe MR, highlighting the successful application of the MitraCut technique as a viable alternative in high-risk scenarios. The imperative for further research and clinical studies is emphasized to comprehensively elucidate outcomes and safety parameters, providing valuable insights for refining TMVR applications within this context.

3.
Transpl Int ; 36: 11089, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547752

RESUMEN

Extending selection criteria to face donor organ shortage in heart transplantation (HTx) may increase the risk of mortality. Ex-vivo normothermic perfusion (EVP) limits ischemic time allowing assessment of graft function. We investigated the outcome of HTx in 80 high-risk recipients transplanted with marginal donor and EVP-preserved grafts, from 2016 to 2021. The recipients median age was 57 years (range, 13-75), with chronic renal failure in 61%, impaired liver function in 11% and previous cardiac surgery in 90%; 80% were mechanically supported. Median RADIAL score was 3. Mean graft ischemic time was 118 ± 25 min, "out-of-body" time 420 ± 66 min and median cardiopulmonary bypass (CPB) time 228 min (126-416). In-hospital mortality was 11% and ≥moderate primary graft dysfunction 16%. At univariable analysis, CPB time and high central venous pressure were risk factors for mortality. Actuarial survival at 1 and 3 years was 83% ± 4%, and 72% ± 7%, with a median follow-up of 16 months (range 2-43). Recipient and donor ages, pre-HTx extracorporeal life support and intra-aortic balloon pump were risk factors for late mortality. In conclusion, the use of EVP allows extension of the graft pool by recruitment of marginal donors to successfully perform HTx even in high-risk recipients.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Obtención de Tejidos y Órganos , Humanos , Persona de Mediana Edad , Donantes de Tejidos , Perfusión , Preservación de Órganos , Supervivencia de Injerto
4.
Artículo en Inglés | MEDLINE | ID: mdl-36858067

RESUMEN

BACKGROUND: The minimally invasive mitral valve procedure warrants minimal surgical trauma and might influence the postoperative course positively, especially in old patients. In this retrospective study, we reviewed our experience in minimally invasive mitral valve surgery (miMVS) in patients aged ≥ 75 years. METHODS: In this retrospective cohort study, based on propensity score matching, we compared patients aged ≥75 years with patients aged <75 years who underwent miMVS. The primary endpoint was 30-day mortality. Secondary endpoints were myocardial infarction, stroke, and renal failure. RESULTS: Between January 2011 and February 2021, 761 patients underwent miMVS at our institution. After propensity score matching, a study group (≥75 years, n = 189) and a control group (<75 years, n = 189) were formed. Preoperatively patients ≥75 years more often suffered from NYHA III heart failure (60 vs. 46%; p = 0.013). Their valves were more often frequently replaced (48 vs. 32%; p < 0.001), and their postoperative ventilation time was longer (13 hours vs. 11 hours; p < 0.001). There were no statistically significant differences regarding postoperative stroke (3 vs. 0.6%; p = 0.16), myocardial infarction (0 vs. 1%; p = 0.32), renal insufficiency with new dialysis (5 vs. 4%; p = 0.62), and 30-day mortality (4 vs. 2%; p = 0.56). CONCLUSION: miMVS results in satisfactory early postoperative outcomes in elderly patients.

5.
J Thorac Cardiovasc Surg ; 166(1): 38-48.e4, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-34583844

RESUMEN

OBJECTIVE: The study objective was to analyze the effects of chronic oral anticoagulation on long-term outcomes after repair of type A acute aortic dissection and its influence on false lumen fate. METHODS: We studied 188 patients (median age, 62 years; 74% were male) who underwent repair of type A aortic dissection; patients receiving postoperative chronic oral anticoagulation (n = 59) were compared with those receiving antiplatelet therapy alone (n = 129). RESULTS: Median age was similar: 60 years (18-79 years; OAC group) versus 64 years (22-86; no-OAC group) (P = .11); patients taking anticoagulants were more frequently male (88% vs 67%, P = .003). After a median follow-up of 8.4 years (2 months to 30 years), 58 patients died, 18 of aortic-related causes, and 37 patients underwent aortic reintervention. After multivariable adjustment, anticoagulation showed no significant effect on long-term survival (hazard ratio, 0.85; 95% confidence interval, 0.41-1.76; P = .66) or risk of reintervention (hazard ratio, 0.55; 95% confidence interval, 0.27-1.15; P = .11). Analysis of 127 postoperative computed tomography scans showed a patent false lumen in 53% of anticoagulated patients versus 38% of nonanticoagulated patients (P = .09): partially thrombosed in 8% versus 28% (P = .01) and thrombosed in 39% versus 34% (P = .63), respectively. In patients with a control computed tomography, there were 6 late aortic-related deaths, 1 among anticoagulated patients and 5 in those who were not. CONCLUSIONS: Chronic anticoagulation after repair of type A acute aortic dissection favors persistent late false lumen patency, which is not a risk factor for late mortality or reoperation. Chronic anticoagulation can be administered safely to patients with repaired type A acute aortic dissection regardless of its specific indication.


Asunto(s)
Anticoagulantes , Disección Aórtica , Humanos , Masculino , Persona de Mediana Edad , Femenino , Anticoagulantes/efectos adversos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aorta , Periodo Posoperatorio , Reoperación
6.
Indian J Thorac Cardiovasc Surg ; 38(2): 207-210, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35221560

RESUMEN

We report a patient who presented with paraplegia after ascending aorta and arch replacement using the frozen elephant trunk technique. Immediate postoperatively cerebrospinal fluid drainage allowed successful reversal of spinal cord injury. Early awakening of patients following a frozen elephant trunk technique is mandatory because it allows recognition and treatment of this complication by prompt cerebrospinal liquor drainage.

7.
J Clin Med ; 10(17)2021 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-34501320

RESUMEN

This observational study aimed to: (i) assess the presence of periodontal disease among patients requiring aortic valve replacement; (ii) investigate the presence of oral pathogens in aortic valve specimens and compare them with the microorganisms detected in the oral cavity. Twenty-six patients (15 men and 11 women) were scheduled to be visited the day before the cardiac surgery: periodontal conditions were accurately registered through clinical and radiographic examinations; dental plaque or salivary samples were collected. Valve specimens were collected during surgical aortic valve replacement and analyzed for pathogens detection through microbiological 16SrRna gene sequencing. Bacteria found in plaque samples and valve specimens were assessed according to oral and periodontal conditions. A qualitative comparison between oral and cardiac profiles of the microorganisms detected was performed. The overall number of patients examined for soft tissues conditions was 19, as 7 patients were edentulous. Twelve and three individuals, respectively, presented moderate and severe periodontitis. Nine valves were found to be positive for the presence of oral and periodontopathic bacterial DNA. The microbial species found in valve samples of patients with periodontitis suggest that the presence of these microorganisms in valvular tissue seems to be not coincidental.

8.
Ann Thorac Surg ; 112(1): e61-e64, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33662315

RESUMEN

Tricuspid valve replacement is commonly performed using biologic or mechanical prostheses. Partial or complete valve replacement using mitral homograft tissue has also been described. Anecdotal reports exist of valve replacement using a pulmonary homograft within a cylinder. This report describes a technique for native or prosthetic valve replacement using a freehand scalloped pulmonary homograft. Late follow-up confirmed the efficacy of this surgical strategy.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Endocarditis Bacteriana/complicaciones , Enfermedades de las Válvulas Cardíacas/cirugía , Válvula Pulmonar/trasplante , Válvula Tricúspide/cirugía , Adulto , Aloinjertos , Ecocardiografía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/etiología , Humanos , Válvula Tricúspide/diagnóstico por imagen
9.
Am J Cardiol ; 142: 103-108, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33278359

RESUMEN

Right-parasternal-view (RPV) often provides the best hemodynamic assessment of the aortic-valve-stenosis by echocardiography. However, no detailed study on patients with aortic prosthesis is available. Thus, RPV usefulness is left as an anecdotical notion in this context. We aimed to define feasibility and clinical-impact of RPV before and soon-after percutaneous implantation (TAVI) or surgical (SAVR) aortic-valve-replacement (AVR) for AS. Patients with severe-AS electively referred for AVR between September-2019 and February-2020 were prospectively evaluated. Echocardiographic examinations inclusive of apical and RPV to measure aortic-peak-velocity , gradients and area (AVA) were performed the day before AVR and at hospital discharge and compared by matched-pair-analysis. Forty-seven patients (mean age 79 ± 8 years, 63% female, ejection-fraction 61 ± 6%) referred for SAVR (24 [51%]) or TAVI (23 [49%]) were enrolled. RPV was feasible in 45 patients (96%) before-AVR but in only 32 after-AVR (68%), particularly after SAVR (50%) than TAVI (87% p = 0.005). RPV remained the best acoustic window after TAVI in 75% of cases. Hemodynamic assessment of TAVI, but not SAVR, invariably benefit from RPV versus apical evaluation (aortic-peak-velocity: 2.57 ± 0.39 vs 2.23 ± 0.47 m/sec, p = 0.002; mean gradient: 15 ± 5 vs 12 ± 5 mm Hg, p = 0.01). Five (11%) patients presented severe patient-prosthesis-mismatch, 4 of which were detectable only by RPV. This pilot-experience demonstrates that RPV feasibility is slightly reduced after AVR. RPV can improve the hemodynamic assessment of the prosthetic valve versus apical view, including the detection of patient-prosthesis-mismatch. Furthermore, when RPV is the best acoustic windows in patients with severe AS, it generally remains so after-TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Presión Arterial , Velocidad del Flujo Sanguíneo , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Proyectos Piloto , Cuidados Posoperatorios , Cuidados Preoperatorios , Ajuste de Prótesis , Presión Ventricular
10.
Interact Cardiovasc Thorac Surg ; 32(3): 476-482, 2021 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-33221874

RESUMEN

OBJECTIVES: Patients with mechanical circulatory support bridged to a heart transplant (HTx) are at higher risk of postoperative graft dysfunction. In this subset, a mode of graft preservation that shortens graft ischaemia should be beneficial. METHODS: The outcomes of 38 patients on mechanical circulatory support (extracorporeal life support, left ventricular assist device and biventricular assist device) who received a HTx between 2015 and 2020 were analysed according to the method of graft preservation: cold storage (CS) group, 24 (63%) or ex vivo perfusion (EVP) group, 14 (37%). RESULTS: The median age was 57 (range 30-73) vs 64 (35-75) years (P = 0.10); 88% were men (P = 0.28); extracorporeal life support was more frequent in the CS group (54% vs 36%; P = 0.27) versus left ventricular and biventricular assist devices in the EVP group (46% vs 64%; P = 0.27). Clamping time was shorter in the EVP group (P < 0.001) and ischaemic time >4 h was higher in the CS group (P = 0.01). Thirty-day mortality was 13% (0-27%) in the CS group and 0% (P = 0.28) in the EVP group. A significantly lower primary graft failure [7% (0-23%) vs 42% (20-63%); P = 0.03] was observed in the EVP group. Survival at 1 year was 79 ± 8% (63-95%) in the CS group and 84 ± 10% (64-104%) in the EVP group (P = 0.95). CONCLUSIONS: Our results support the use of ex vivo graft perfusion in patients on mechanical circulatory support as a bridge to a HTx. This technique, by shortening graft ischaemic time, seems to improve post-HTx outcomes.


Asunto(s)
Criopreservación/métodos , Oxigenación por Membrana Extracorpórea/métodos , Trasplante de Corazón/métodos , Preservación de Órganos/métodos , Perfusión/métodos , Adulto , Anciano , Circulación Extracorporea/métodos , Circulación Extracorporea/tendencias , Oxigenación por Membrana Extracorpórea/tendencias , Femenino , Estudios de Seguimiento , Trasplante de Corazón/tendencias , Corazón Auxiliar/tendencias , Humanos , Masculino , Persona de Mediana Edad , Preservación de Órganos/tendencias , Perfusión/tendencias , Estudios Retrospectivos , Resultado del Tratamiento
12.
J Card Surg ; 35(3): 679-682, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31886917

RESUMEN

Mesothelial/monocytic incidental cardiac excrescence (MICE) is a rare benign finding made of mesothelial cells, histiocytes, and fibrin, usually found during heart valve surgery. The clinical relevance resides in the potential misdiagnosis as metastatic carcinoma or arterial embolism. The pathogenesis remains uncertain, with artifactual and reactive hypotheses. Here we present a case of MICE with paradigmatic clinical, imaging, and histological features in a 28-year-old woman with undifferentiated connective tissue disease without previous cardiac catheterization with possible pathogenesis, highlighting the importance of awareness of the existence of this lesion in patients with autoimmune disease.


Asunto(s)
Enfermedades Autoinmunes/complicaciones , Cardiomiopatías/patología , Cardiomiopatías/cirugía , Enfermedades del Tejido Conjuntivo/complicaciones , Epitelio/patología , Hallazgos Incidentales , Monocitos/patología , Miocardio/patología , Adulto , Procedimientos Quirúrgicos Cardíacos , Cardiomiopatías/etiología , Diagnóstico Diferencial , Femenino , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...