1.
Parkinsonism Relat Disord ; 124: 106996, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38776725

RESUMEN

INTRODUCTION: Identifying biomarkers reflecting cellular dysfunctions in early Parkinson's disease patients (ePD) is needed to develop targeted therapeutic strategies. We aimed to determine if cellular energetic dysfunction related to increased brain sodium concentration would be co-located to microstructural alterations and iron deposition in ePD. METHODS: We prospectively included 12 ePD (mean disease duration 20.0 ± 10.2 months) and 13 healthy controls (HC), scanned with a 7 T 1H and 23Na MRI. Complementary voxel-based and region-based assessments were performed, the latter utilizing a high-resolution multimodal template we created (combining quantitative T1 maps (qT1), transverse relaxation rate (R2*), quantitative magnetic susceptibility mapping (QSM) images) from 200 subjects. This template allowed a precise multiparametric assessment of sodium concentration, QSM, R2*, qT1, mean diffusivity, and fractional anisotropy values. A two-sided p-value<0.05 was considered statistically significant after the Bonferroni correction. RESULTS: Relative to HC, ePD showed significantly higher sodium concentration in left Substantia nigra (SN) pars reticulata (46.13 mM ± 3.52 vs 38.60 mM ± 6.10, p = 0.038), a subpart of the SN pars compacta (SNc) and ventral tegmental area, Putamen, Globus Pallidum external, accumbens nucleus and claustrum. Significantly increased QSM and R2* values, and decreased T1 values, were limited to the Nigrosomes 1 (Nig) and right SNc (all p < 0.05). QSM values in the Nig were significantly correlated to UPDRS-III scores (r = 0.91,p < 0.001). CONCLUSION: In ePD, brain sodium accumulation was broad and dissociated from iron accumulation. As with iron accumulation, a sodium-related pathophysiological approach could lead to identifying potential new therapeutic agents and deserves further investigation.

2.
NMR Biomed ; 35(7): e4701, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35088465

RESUMEN

Magnetic resonance elastography aims to non-invasively and remotely characterize the mechanical properties of living tissues. To quantitatively and regionally map the shear viscoelastic moduli in vivo, the technique must achieve proper mechanical excitation throughout the targeted tissues. Although it is straightforward, ante manibus, in close organs such as the liver or the breast, which practitioners clinically palpate already, it is somewhat fortunately highly challenging to trick the natural protective barriers of remote organs such as the brain. So far, mechanical waves have been induced in the latter by shaking the surrounding cranial bones. Here, the skull was circumvented by guiding pressure waves inside the subject's buccal cavity so mechanical waves could propagate from within through the brainstem up to the brain. Repeatable, reproducible and robust displacement fields were recorded in phantoms and in vivo by magnetic resonance elastography with guided pressure waves such that quantitative mechanical outcomes were extracted in the human brain.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen
3.
Eur J Neurosci ; 55(2): 438-460, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34939245

RESUMEN

We present a new consensus atlas of deep grey nuclei obtained by shape-based averaging of manual segmentation of two experienced neuroradiologists and optimized from 7T MP2RAGE images acquired at (.6 mm)3 in 60 healthy subjects. A group-wise normalization method was used to build a high-contrast and high-resolution T1 -weighted brain template (.5 mm)3 using data from 30 out of the 60 controls. Delineation of 24 deep grey nuclei per hemisphere, including the claustrum and 12 thalamic nuclei, was then performed by two expert neuroradiologists and reviewed by a third neuroradiologist according to tissue contrast and external references based on the Morel atlas. Corresponding deep grey matter structures were also extracted from the Morel and CIT168 atlases. The data-derived, Morel and CIT168 atlases were all applied at the individual level using non-linear registration to fit the subject reference and to extract absolute mean quantitative T1 values derived from the 3D-MP2RAGE volumes, after correction for residual B1+ biases. Three metrics (the Dice and the volumetric similarity coefficients and a novel Hausdorff distance) were used to estimate the inter-rater agreement of manual MRI segmentation and inter-atlas variability, and these metrics were measured to quantify biases due to image registration, and their impact on the measurements of the quantitative T1 values was highlighted. This represents a fully automated segmentation process permitting the extraction of unbiased normative T1 values in a population of young healthy controls as a reference for characterizing subtle structural alterations of deep grey nuclei relevant to a range of neurological diseases.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Mapeo Encefálico/métodos , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Núcleos Talámicos
4.
Magn Reson Med ; 84(6): 3286-3299, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32618387

RESUMEN

PURPOSE: Performing simultaneous quantitative MRI at ultrahigh field is challenging, as B0 and B1+ heterogeneities as well as specific absorption rate increase. Too large deviations of flip angle from the target can induce biases and impair SNR in the quantification process. In this work, we use calibration-free parallel transmission, a dedicated pulse-sequence parameter optimization and signal fitting to recover 3D proton density, flip angle, T1 , and T2 maps over the whole brain, in a clinically suitable time. METHODS: Eleven optimized contrasts were acquired with an unbalanced SSFP sequence by varying flip-angle amplitude and RF phase-cycling increment, at a 1.0 × 1.0 × 3.0 mm3 resolution. Acquisition time was 16 minutes 36 seconds for the whole brain. Parallel transmission and universal pulses were used to mitigate B1+ heterogeneity, to improve the results' reliability over 6 healthy volunteers (3 females/3 males, age 22.6 ± 2.7 years old). Quantification of the physical parameters was performed by fitting the acquired contrasts to the simulated ones using the Bloch-Torrey equations with a realistic diffusion coefficient. RESULTS: Whole-brain 3D maps of effective flip angle, proton density, and relaxation times were estimated. Parallel transmission improved the robustness of the results at 7 T. Results were in accordance with literature and with measurements from standard methods. CONCLUSION: These preliminary results show robust proton density, flip angle, T1 , and T2 map retrieval. Other parameters, such as ADC, could be assessed. With further optimization in the acquisition, scan time could be reduced and spatial resolution increased to bring this multiparametric quantification method to clinical research routine at 7 T.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Protones , Adulto , Algoritmos , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Fantasmas de Imagen , Reproducibilidad de los Resultados , Adulto Joven
5.
Rev Sci Instrum ; 91(2): 024102, 2020 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32113406

RESUMEN

The dependence of the nuclear magnetic resonance relaxation rate on the magnetic field has been widely studied, in particular, in biomedical areas with the objectives to better understand the underlying microscopic mechanisms in tissues and provide biomarkers of diseases. By combining fast-field cycling (FFC) and magnetic resonance imaging (MRI), it is possible to provide localized relaxation dispersion measurements in heterogeneous systems with recent demonstrations in solutions, biological samples, human beings, and small animals. We report here the developments and performances of a device designed for small animal FFC-MRI comprising a resistive insert technology operating inside a 1.5 T MRI system. Specific measurement methods were developed to characterize the system efficiency, response time, homogeneity, stability, and compensation. By adding a non-linear element in the system and using a dual amplifier strategy, it is shown that large field offsets can be produced during relaxation periods while maintaining precise field control during detection periods. The measurement of longitudinal nuclear magnetic relaxation dispersion (NMRD) profiles in the range of 1.08 T-1.92 T is reported, essentially displaying a linear variation in this range for common MRI contrast agents. The slopes of both the longitudinal and transverse relaxation dispersion profiles at 1.5 T are measured and validated, extending the capabilities of previous approaches. The performances of a longitudinal relaxation dispersion mapping method are finally reported, opening the way to quantitative preclinical dispersion imaging studies at a high FFC-MRI field.


Asunto(s)
Imagen por Resonancia Magnética/instrumentación , Calibración , Diseño de Equipo , Factores de Tiempo
6.
EBioMedicine ; 52: 102365, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31447395

RESUMEN

BACKGROUND: Total liquid ventilation (TLV) of the lungs could provide radically new benefits in critically ill patients requiring lung lavage or ultra-fast cooling after cardiac arrest. It consists in an initial filling of the lungs with perfluorocarbons and subsequent tidal ventilation using a dedicated liquid ventilator. Here, we propose a new paradigm for a lung-conservative TLV using pulmonary volumes of perfluorocarbons below functional residual capacity (FRC). METHODS AND FINDINGS: Using a dedicated technology, we showed that perfluorocarbon end-expiratory volumes could be maintained below expected FRC and lead to better respiratory recovery, preserved lung structure and accelerated evaporation of liquid residues as compared to complete lung filling in piglets. Such TLV below FRC prevented volutrauma through preservation of alveolar recruitment reserve. When used with temperature-controlled perfluorocarbons, this lung-conservative approach provided neuroprotective ultra-fast cooling in a model of hypoxic-ischemic encephalopathy. The scale-up and automating of the technology confirmed that incomplete initial lung filling during TLV was beneficial in human adult-sized pigs, despite larger size and maturity of the lungs. Our results were confirmed in aged non-human primates, confirming the safety of this lung-conservative approach. INTERPRETATION: This study demonstrated that TLV with an accurate control of perfluorocarbon volume below FRC could provide the full potential of TLV in an innovative and safe manner. This constitutes a new paradigm through the tidal liquid ventilation of incompletely filled lungs, which strongly differs from the previously known TLV approach, opening promising perspectives for a safer clinical translation. FUND: ANR (COOLIVENT), FRM (DBS20140930781), SATT IdfInnov (project 273).


Asunto(s)
Ventilación Liquida/métodos , Pulmón , Rehabilitación , Animales , Biopsia , Cuidados Críticos , Fluorocarburos/administración & dosificación , Hipotermia Inducida , Inmunohistoquímica , Ventilación Liquida/instrumentación , Macaca fascicularis , Recuperación de la Función , Rehabilitación/instrumentación , Rehabilitación/métodos , Pruebas de Función Respiratoria , Porcinos , Tomografía Computarizada por Rayos X
7.
Alzheimers Dement (Amst) ; 11: 538-549, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31388558

RESUMEN

INTRODUCTION: The goal of European Ultrahigh-Field Imaging Network in Neurodegenerative Diseases (EUFIND) is to identify opportunities and challenges of 7 Tesla (7T) MRI for clinical and research applications in neurodegeneration. EUFIND comprises 22 European and one US site, including over 50 MRI and dementia experts as well as neuroscientists. METHODS: EUFIND combined consensus workshops and data sharing for multisite analysis, focusing on 7 core topics: clinical applications/clinical research, highest resolution anatomy, functional imaging, vascular systems/vascular pathology, iron mapping and neuropathology detection, spectroscopy, and quality assurance. Across these topics, EUFIND considered standard operating procedures, safety, and multivendor harmonization. RESULTS: The clinical and research opportunities and challenges of 7T MRI in each subtopic are set out as a roadmap. Specific MRI sequences for each subtopic were implemented in a pilot study presented in this report. Results show that a large multisite 7T imaging network with highly advanced and harmonized imaging sequences is feasible and may enable future multicentre ultrahigh-field MRI studies and clinical trials. DISCUSSION: The EUFIND network can be a major driver for advancing clinical neuroimaging research using 7T and for identifying use-cases for clinical applications in neurodegeneration.

8.
J Neuroimaging ; 29(6): 689-698, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31379055

RESUMEN

BACKGROUND AND PURPOSE: Quantitative susceptibility mapping (QSM) of the brain has become highly reproducible and has applications in an expanding array of diseases. To translate QSM from bench to bedside, it is important to automate its reconstruction immediately after data acquisition. In this work, a server system that automatically reconstructs QSM and exchange images with the scanner using the DICOM standard is demonstrated using a multi-site, multi-vendor reproducibility study and a large, single-site, multi-scanner image quality review study in a clinical environment. METHODS: A single healthy subject was scanned with a 3D multi-echo gradient echo sequence at nine sites around the world using scanners from three manufacturers. A high-resolution (HiRes, .5 × .5 × 1 mm3 reconstructed) and standard-resolution (StdRes, .5 × .5 × 3 mm3 ) protocol was performed. ROI analysis of various white matter and gray matter regions was performed to investigate reproducibility across sites. At one institution, a retrospective multi-scanner image quality review was carried out of all clinical QSM images acquired consecutively in 1 month. RESULTS: Reconstruction times using a GPU were 29 ± 22 seconds (StdRes) and 55 ± 39 seconds (HiRes). ROI standard deviation across sites was below 24 ppb (StdRes) and 17 ppb (HiRes). Correlations between ROI averages across sites were on average .92 (StdRes) and .96 (HiRes). Image quality review of 873 consecutive patients revealed diagnostic or excellent image quality in 96% of patients. CONCLUSION: Online QSM reconstruction for a variety of sites and scanner platforms with low cross-site ROI standard deviation is demonstrated. Image quality review revealed diagnostic or excellent image quality in 96% of 873 patients.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Mapeo Encefálico/métodos , Sustancia Gris/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sustancia Blanca/diagnóstico por imagen
9.
World Neurosurg ; 122: e10-e19, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30201583

RESUMEN

OBJECTIVE: To introduce quantitative susceptibility mapping (QSM), a novel magnetic resonance imaging sequence, to the field of neurosurgery. METHODS: QSM is introduced both in its historical context and by providing a brief overview of the physics behind the technique tailored to a neurosurgical audience. Its application to clinical neurosurgery is then highlighted using case examples. RESULTS: QSM offers a quantitative assessment of susceptibility (previously considered as an artifact) via a single, straightforward gradient echo acquisition. QSM differs from standard susceptibility weighted imaging in its ability to both quantify and precisely localize susceptibility effects. Clinical applications of QSM are wide reaching and include precise localization of the deep nuclei for deep brain stimulation electrode placement, differentiation between blood products and calcification within brain lesions, and enhanced sensitivity of cerebral micrometastasis identification. CONCLUSIONS: We present this diverse range of QSM's clinical applications to neurosurgical care via case examples. QSM can be obtained in all patients able to undergo magnetic resonance imaging and is easily integratable into busy neuroradiology programs because of its short acquisition time and straightforward, automated offline postprocessing workflow. Clinical integration of QSM may help clinicians better identify and characterize neurosurgical lesions, thereby improving patient care.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Procedimientos Neuroquirúrgicos , Cirugía Asistida por Computador , Adolescente , Anciano , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Encefalopatías/diagnóstico por imagen , Encefalopatías/cirugía , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
NMR Biomed ; 31(12): e4013, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30307075

RESUMEN

Asthma is a chronic respiratory disease, commonly treated with inhaled therapy. Better understanding of the mechanisms of aerosol deposition is required to improve inhaled drug delivery. Three-dimensional ultrashort echo time (UTE) MRI acquisitions at 1.5 T were combined with spontaneous nose-only inhalation of aerosolized gadolinium (Gd) to map the aerosol deposition and to characterize signal enhancement in asthmatic rat lungs. The rats were sensitized to ovalbumin (OVA) to develop asthmatic models and challenged before imaging by nebulization of OVA to trigger asthmatic symptoms. The negative controls were not sensitized or challenged by nebulization of saline. The animal lungs were imaged before and after administration of Gd-based aerosol in freely breathing rats, by using a T1 -weighted 3D UTE sequence. A contrast-enhanced quantitative analysis was performed to assess regional concentration. OVA-sensitized rats had lower signal enhancement and lower deposited aerosol concentration. Their enhancement dynamics showed large inter-subject variability. The signal intensity was homogeneously enhanced for controls while OVA-sensitized rats showed heterogeneous enhancement. Contrast-enhanced 3D UTE was applied with aerosolized Gd to efficiently measure spatially resolved deposition in asthmatic lungs. The small administered dose (around 1 µmol/kg body weight) and the use of standard clinical MRI suggest a potential application for the exploration of asthma.


Asunto(s)
Aerosoles/análisis , Asma/diagnóstico por imagen , Asma/patología , Compuestos Heterocíclicos/química , Imagenología Tridimensional , Pulmón/diagnóstico por imagen , Pulmón/patología , Imagen por Resonancia Magnética , Compuestos Organometálicos/química , Animales , Femenino , Ratas Wistar , Respiración , Factores de Tiempo
11.
Magn Reson Imaging ; 53: 156-163, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30055291

RESUMEN

PURPOSE: Quantifying multiple NMR properties of sodium could be of benefit to assess changes in cellular viability in biological tissues. A proof of concept of Quantitative Imaging using Configuration States (QuICS) based on a SSFP sequence with multiple contrasts was implemented to extract simultaneously 3D maps of applied flip angle (FA), total sodium concentration, T1, T2, and Apparent Diffusion Coefficient (ADC). METHODS: A 3D Cartesian Gradient Recalled Echo (GRE) sequence was used to acquire 11 non-balanced SSFP contrasts at a 6 × 6 × 6 mm3 isotropic resolution with carefully-chosen gradient spoiling area, RF amplitude and phase cycling, with TR/TE = 20/3.2 ms and 25 averages, leading to a total acquisition time of 1 h 18 min. A least-squares fit between the measured and the analytical complex signals was performed to extract quantitative maps from a mono-exponential model. Multiple sodium phantoms with different compositions were studied to validate the ability of the method to measure sodium NMR properties in various conditions. RESULTS: Flip angle maps were retrieved. Relaxation times, ADC and sodium concentrations were estimated with controlled precision below 15%, and were in accordance with measurements from established methods and literature. CONCLUSION: The results illustrate the ability to retrieve sodium NMR properties maps, which is a first step toward the estimation of FA, T1, T2, concentration and ADC of 23Na for clinical research. With further optimization of the acquired QuICS contrasts, scan time could be reduced to be suitable with in vivo applications.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagenología Tridimensional/métodos , Sodio/química , Artefactos , Supervivencia Celular , Humanos , Espectroscopía de Resonancia Magnética , Método de Montecarlo , Fantasmas de Imagen , Relación Señal-Ruido
12.
NMR Biomed ; 31(1)2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29130539

RESUMEN

The purpose of this work was to investigate sources of bias in magnetic resonance imaging (MRI) liver fat quantification that lead to a dependence of the proton density fat fraction (PDFF) on the number of echoes. This was a retrospective analysis of liver MRI data from 463 subjects. The magnitude signal variation with TE from spoiled gradient echo images was curve fitted to estimate the PDFF using a model that included monoexponential R2 * decay and a multi-peak fat spectrum. Additional corrections for non-exponential decay (Gaussian), bi-exponential decay, degree of fat saturation, water frequency shift and noise bias were introduced. The fitting error was minimized with respect to 463 × 3 = 1389 subject-specific parameters and seven additional parameters associated with these corrections. The effect on PDFF was analyzed, notably the dependence on the number of echoes. The effects on R2 * were also analyzed. The results showed that the inclusion of bias corrections resulted in an increase in the quality of fit (r2 ) in 427 of 463 subjects (i.e. 92.2%) and a reduction in the total fitting error (residual norm) of 43.6%. This was largely a result of the Gaussian decay (57.8% of the reduction), fat spectrum (31.0%) and biexponential decay (8.8%) terms. The inclusion of corrections was also accompanied by a decrease in the dependence of PDFF on the number of echoes. Similar analysis of R2 * showed a decrease in the dependence on the number of echoes. Comparison of PDFF with spectroscopy indicated excellent agreement before and after correction, but the latter exhibited lower bias on a Bland-Altman plot (1.35% versus 0.41%). In conclusion, correction for known and expected biases in PDFF quantification in liver reduces the fitting error, decreases the dependence on the number of echoes and increases the accuracy.


Asunto(s)
Adiposidad , Hígado/metabolismo , Imagen por Resonancia Magnética , Protones , Adolescente , Adulto , Anciano , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Análisis de Regresión , Adulto Joven
13.
Contrast Media Mol Imaging ; 2017: 7498538, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29097936

RESUMEN

Molecular magnetic resonance imaging targeted to an endothelial integrin involved in neoangiogenesis was compared to DCE-US and immunochemistry to assess the early response of three different therapeutic agents in renal cell carcinoma. Human A498 renal cells carcinoma was subcutaneously inoculated into 24 nude mice. Mice received either phosphate-buffered saline solution, sunitinib, everolimus, or bevacizumab during 4 days. DCE-US and molecular MRI targeting αvß3 were performed at baseline and 4 days after treatment initiation. PI, AUC, relaxation rate variations ΔR2⁎, and percentage of vessels area quantified on CD31-stained microvessels were compared. Significant decreases were observed for PI and AUC parameters measured by DCE-US for bevacizumab group as early as 4 days, whereas molecular αvß3-targeted MRI was able to detect significant changes in both bevacizumab and everolimus groups. Percentage of CD31-stained microvessels was significantly correlated with DCE-US parameters, PI (R = 0.87, p = 0.0003) and AUC (R = 0.81, p = 0.0013). The percentage of vessel tissue area was significantly reduced (p < 0.01) in both sunitinib and bevacizumab groups. We report an early detection of neoangiogenesis modification after induction of targeted therapies, using DCE-US or αvß3-targeted MRI. We consider these outcomes should encourage clinical trial developments to further evaluate the potential of this molecular MRI technique.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Imagen Molecular/métodos , Terapia Molecular Dirigida/métodos , Animales , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Bevacizumab/farmacología , Bevacizumab/uso terapéutico , Carcinoma de Células Renales/irrigación sanguínea , Carcinoma de Células Renales/tratamiento farmacológico , Línea Celular Tumoral , Everolimus/farmacología , Everolimus/uso terapéutico , Xenoinjertos , Humanos , Indoles/farmacología , Indoles/uso terapéutico , Imagen por Resonancia Magnética/métodos , Masculino , Ratones , Pirroles/farmacología , Pirroles/uso terapéutico , Sunitinib , Resultado del Tratamiento
14.
IEEE Trans Biomed Eng ; 64(11): 2531-2545, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28885147

RESUMEN

Quantitative susceptibility mapping (QSM) solves the magnetic field-to-magnetization (tissue susceptibility) inverse problem under conditions of noisy and incomplete field data acquired using magnetic resonance imaging. Therefore, sophisticated algorithms are necessary to treat the ill-posed nature of the problem and are reviewed here. The forward problem is typically presented as an integral form, where the field is the convolution of the dipole kernel and tissue susceptibility distribution. This integral form can be equivalently written as a partial differential equation (PDE). Algorithmic challenges are to reduce streaking and shadow artifacts characterized by the fundamental solution of the PDE. Bayesian maximum a posteriori estimation can be employed to solve the inverse problem, where morphological and relevant biomedical knowledge (specific to the imaging situation) are used as priors. As the cost functions in Bayesian QSM framework are typically convex, solutions can be robustly computed using a gradient-based optimization algorithm. Moreover, one can not only accelerate Bayesian QSM, but also increase its effectiveness at reducing shadows using prior knowledge based preconditioners. Improving the efficiency of QSM is under active development, and a rigorous analysis of preconditioning needs to be carried out for further investigation.Quantitative susceptibility mapping (QSM) solves the magnetic field-to-magnetization (tissue susceptibility) inverse problem under conditions of noisy and incomplete field data acquired using magnetic resonance imaging. Therefore, sophisticated algorithms are necessary to treat the ill-posed nature of the problem and are reviewed here. The forward problem is typically presented as an integral form, where the field is the convolution of the dipole kernel and tissue susceptibility distribution. This integral form can be equivalently written as a partial differential equation (PDE). Algorithmic challenges are to reduce streaking and shadow artifacts characterized by the fundamental solution of the PDE. Bayesian maximum a posteriori estimation can be employed to solve the inverse problem, where morphological and relevant biomedical knowledge (specific to the imaging situation) are used as priors. As the cost functions in Bayesian QSM framework are typically convex, solutions can be robustly computed using a gradient-based optimization algorithm. Moreover, one can not only accelerate Bayesian QSM, but also increase its effectiveness at reducing shadows using prior knowledge based preconditioners. Improving the efficiency of QSM is under active development, and a rigorous analysis of preconditioning needs to be carried out for further investigation.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Artefactos , Teorema de Bayes , Encéfalo/diagnóstico por imagen , Simulación por Computador , Humanos
15.
Neuroimage Clin ; 15: 274-283, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28560152

RESUMEN

INTRODUCTION/PURPOSE: In vivo detection of cerebral microbleeds (CMBs) from T2* gradient recalled echo (GRE) magnitude image suffers from low specificity, modest inter-rater reproducibility and is biased by its sensitivity to acquisition parameters. New methods were proposed for improving this identification, but they mostly rely on 3D acquisitions, not always feasible in clinical practice. A fast 2D phase processing technique for computing internal field maps (IFM) has been shown to make it possible to characterize CMBs through their magnetic signature in routine clinical setting, based on 2D multi-slice acquisitions. However, its clinical interest for CMBs identification with respect to more common images remained to be assessed. To do so, systematic experiments were undertaken to compare the ratings obtained by trained observers with several image types, T2* magnitude, Susceptibility Weighted Imaging reconstructions (SWI) and IFM built from the same T2*-weighted acquisition. MATERIALS/METHODS: 15 participants from the MEMENTO multi-center cohort were selected: six subjects with numerous CMBs (20 ± 6 CMBs), five subjects with a few CMBs (2 ± 1 CMBs) and four subjects without CMB. 2D multi-slice T2* GRE sequences were acquired on Philips and Siemens 3T systems. After pilot experiments, T2* magnitude, Susceptibility Weighted Imaging (SWI) minimum intensity projection (mIP) on three slices and IFM were considered for the rating experiments. A graphical user interface (GUI) was designed in order to consistently display images in random order. Six raters of various background and expertise independently selected "definite" or "possible" CMBs. Rating results were compared with respect to a specific consensus reference, on both lesion and subject type points of view. RESULTS: IFM yielded increased sensitivity and decreased false positives rate (FPR) for CMBs identification compared to T2* magnitude and SWI-mIP images. Inter-rater variability was decreased with IFM when identifying subjects with numerous lesions, with only a limited increase in rating time. IFM thus appears as an interesting candidate to improve CMBs identification in clinical setting.


Asunto(s)
Hemorragia Cerebral/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/normas , Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
NMR Biomed ; 30(4)2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27717080

RESUMEN

The elimination of so-called background fields is an essential step in phase MRI and quantitative susceptibility mapping (QSM). Background fields, which are caused by sources outside the region of interest (ROI), are often one to two orders of magnitude stronger than tissue-related field variations from within the ROI, hampering quantitative interpretation of field maps. This paper reviews the current literature on background elimination algorithms for QSM and provides insights into similarities and differences between the many algorithms proposed. We discuss the basic theoretical foundations and derive fundamental limitations of background field elimination. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Algoritmos , Artefactos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Técnica de Sustracción , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Relación Señal-Ruido
17.
Magn Reson Med ; 75(2): 594-605, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25809444

RESUMEN

PURPOSE: Aerosol toxicology and drug delivery through the lungs, which depend on various parameters, require methods to quantify particle deposition. Intrapulmonary-administered MRI contrast agent combined with lung-specific imaging sequences has been proposed as a high performance technique for aerosol research. Here, aerosol deposition is assessed using ultra-short echo (UTE) sequences. METHODS: Before and after administration of Gd-DOTA-based aerosol delivered nose-only in free-breathing healthy rats, a T1 -weighted 3D UTE sequence was applied in a clinical 1.5 Tesla scanner. Administration lasted 14 min, and the experiment was performed on six rats. A contrast-enhanced quantitative analysis was done. RESULTS: Fifty percent signal enhancement was obtained in the lung parenchyma. Lung clearance of the contrast agent was evaluated to be 14% per h (corresponding to a characteristic clearance time of 3.6 h) and aerosol deposition was shown to be homogeneous throughout the lung in healthy rats. The total deposited dose was estimated to be 1.05 µmol/kg body weight, and the concentration precision was 0.02 mM. CONCLUSION: The UTE protocol with nebulized Gd-DOTA is replicable to significantly enhance the lung parenchyma and to map aerosol deposition. This functional strategy, applied in a clinical system with a clinical nebulization setup and a low inhaled dose, suggests a feasible translation to human.


Asunto(s)
Medios de Contraste/administración & dosificación , Compuestos Heterocíclicos/administración & dosificación , Pulmón/anatomía & histología , Imagen por Resonancia Cinemagnética/métodos , Compuestos Organometálicos/administración & dosificación , Administración por Inhalación , Administración Intranasal , Aerosoles , Animales , Estudios de Factibilidad , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Ratas , Ratas Wistar
18.
Neuroimage ; 104: 287-300, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25149849

RESUMEN

Cerebral microbleeds (CMBs) have emerged as a new imaging marker of small vessel disease. Composed of hemosiderin, CMBs are paramagnetic and can be detected with MRI sequences sensitive to magnetic susceptibility (typically, gradient recalled echo T2* weighted images). Nevertheless, their identification remains challenging on T2* magnitude images because of confounding structures and lesions. In this context, T2* phase image may play a key role in better characterizing CMBs because of its direct relationship with local magnetic field variations due to magnetic susceptibility difference. To address this issue, susceptibility-based imaging techniques were proposed, such as Susceptibility Weighted Imaging (SWI) and Quantitative Susceptibility Mapping (QSM). But these techniques have not yet been validated for 2D clinical data in multicenter settings. Here, we introduce 2DHF, a fast 2D phase processing technique embedding both unwrapping and harmonic filtering designed for data acquired in 2D, even with slice-to-slice inconsistencies. This method results in internal field maps which reveal local field details due to magnetic inhomogeneity within the region of interest only. This technique is based on the physical properties of the induced magnetic field and should yield consistent results. A synthetic phantom was created for numerical simulations. It simulates paramagnetic and diamagnetic lesions within a 'brain-like' tissue, within a background. The method was evaluated on both this synthetic phantom and multicenter 2D datasets acquired in standardized clinical setting, and compared with two state-of-the-art methods. It proved to yield consistent results on synthetic images and to be applicable and robust on patient data. As a proof-of-concept, we finally illustrate that it is possible to find a magnetic signature of CMBs and CMCs on internal field maps generated with 2DHF on 2D clinical datasets that give consistent results with CT-scans in a subsample of 10 subjects acquired with both modalities.


Asunto(s)
Hemorragia Cerebral/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Bases de Datos Factuales , Humanos
19.
Med Eng Phys ; 37(1): 100-8, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25500196

RESUMEN

Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state.


Asunto(s)
Presión Sanguínea , Técnicas de Imagen Cardíaca/métodos , Ventrículos Cardíacos/anatomía & histología , Imagen por Resonancia Magnética/métodos , Imagen Óptica/métodos , Función Ventricular/fisiología , Animales , Técnicas de Imagen Cardíaca/instrumentación , Estudios de Factibilidad , Femenino , Contracción Miocárdica/fisiología , Imagen Óptica/instrumentación , Tamaño de los Órganos , Presión , Ovinos
20.
BMC Pharmacol Toxicol ; 15: 53, 2014 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-25253660

RESUMEN

BACKGROUND: The respiratory properties of perfluorocarbons (PFC) have been widely studied for liquid ventilation in humans and animals. Several PFC were tested but their tolerance may depend on the species. Here, the effects of a single administration of liquid PFC into pig lungs were assessed and compared. Three different PFC having distinct evaporative and spreading coefficient properties were evaluated (Perfluorooctyl bromide [PFOB], perfluorodecalin [PFD] and perfluoro-N-octane [PFOC]). METHODS: Pigs were anesthetized and submitted to mechanical ventilation. They randomly received an intra-tracheal administration of 15 ml/kg of either PFOB, PFD or PFOC with 12 h of mechanical ventilation before awakening and weaning from ventilation. A Control group was submitted to mechanical ventilation with no PFC administration. All animals were followed during 4 days after the initial PFC administration to investigate gas exchanges and clinical recovery. They were ultimately euthanized for histological analyses and assessment of PFC residual concentrations within the lungs using dual nuclei fluorine and hydrogen Magnetic Resonance Imaging (MRI). Sixteen animals were included (4/group). RESULTS: In the PFD group, animals tended to be hypoxemic after awakening. In PFOB and PFOC groups, blood gases were not significantly different from the Control group after awakening. The poor tolerance of PFD was likely related to a large amount of residual PFC, as observed using MRI in all lung samples (≈10% of lung volume). This percentage was lower in the PFOB group (≈1%) but remained significantly greater than in the Control group. In the PFOC group, the percentage of residual PFC was not significantly different from that of the Control group (≈0.1%). Histologically, the most striking feature was an alveolar infiltration with foam macrophages, especially in the groups treated by PFD or PFOB. CONCLUSIONS: Of the three tested perfluorocarbons, PFOC offered the best tolerance in terms of lung function, gas exchanges and residuum in the lung. PFOC was rapidly cleared from the lungs and virtually disappeared after 4 days whereas PFOB persisted at significant levels and led to foam macrophage infiltration. PFOC could be relevant for short term total liquid ventilation with a rapid weaning.


Asunto(s)
Fluorocarburos/administración & dosificación , Pulmón/efectos de los fármacos , Animales , Pulmón/fisiopatología , Imagen por Resonancia Magnética , Respiración Artificial , Porcinos