Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Food Chem ; 203: 183-189, 2016 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-26948604

RESUMEN

This work reports an in-line electrochemical reagent generation coupled to a flow injection biamperometric procedure for the determination of SO3(2-). The method was based on a redox reaction between the I3(-) and SO3(2-) ions, after the diffusion of SO2 through a gas diffusion chamber. Under optimum experimental conditions, a linear response ranging from 1.0 to 12.0 mg L(-1) (R=0.9999 and n=7), a detection and quantification limit estimated at 0.26 and 0.86 mg L(-1), respectively, a standard deviation relative of 0.4% (n=10) for a reference solution of 4.0 mg L(-1) SO3(2-) and sampling throughput for 40 determinations per hour were achieved. Addition and recovery tests with juice and wine samples were performed resulting in a range between 92% and 110%. There were no significant differences at a 95% confidence level in the analysis of eight samples when comparing the new method with a reference procedure.


Asunto(s)
Bebidas/análisis , Técnicas Electroquímicas/métodos , Aditivos Alimentarios/análisis , Yoduros/química , Sulfitos/análisis , Bebidas/normas , Análisis de Inyección de Flujo/métodos , Jugos de Frutas y Vegetales/análisis , Jugos de Frutas y Vegetales/normas , Indicadores y Reactivos , Límite de Detección , Oxidación-Reducción , Estándares de Referencia , Soluciones , Vino/análisis , Vino/normas
2.
Talanta ; 144: 986-91, 2015 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26452917

RESUMEN

The fluorescence quenching of TGA-CdSe quantum dots (QDs) was used for Cr(3+) quantification in vitamin supplements. The QD was electrochemically synthesized, demonstrating high reproducibility with control of particle size, thus making it a clean method, without the presence of reducing agents. Under ideal conditions, with the fluorescence band at 551 nm (excitation 365 nm), the maximum fluorescence quenching was observed at pH 4.0, with a time of 200 s for each data acquisition. Under optimum experimental conditions, linear quenching was observed for Cr(3+) in the range of 25.0-325.0 ng L(-1) (R=0.9996, n=6), a limit of detection of 5.67 ng L(-1), and relative standard deviation of 4.43% (n=10). The recovery test for Cr(3+) quantification in vitamin supplements presented results from 82% to 98%. These Cr(3+) determination results were compared to the same vitamin supplement sample using flame atomic absortion spectrometry (FAAS) method, and no significant differences were observed at 95% confidence level.


Asunto(s)
Compuestos de Cadmio/química , Cromo/análisis , Suplementos Dietéticos/análisis , Puntos Cuánticos/química , Compuestos de Selenio/química , Tioglicolatos/química , Vitaminas/análisis , Cromo/química , Técnicas Electroquímicas , Colorantes Fluorescentes/química