Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Biochem ; 121-122: 110679, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37884085

RESUMEN

BACKGROUND: The Atellica® VTLi point-of-care (POC) High Sensitivity Cardiac Troponin-I (hs-cTnI) assay is intended for use as an aid in the diagnosis of myocardial infarction (MI). Our primary objective is to assess its diagnostic performance in patients presenting with suspected acute coronary syndrome (ACS). METHODS: This prospective observational study will enrol ∼1500 patients at ∼20 U.S. Emergency Departments. After informed consent, adults (>21 years of age) with suspected ACS, and no prior enrollment in this study, will provide a fingerstick and venous blood sample within 2 h of ED presentation, >2 to ≤4 h, and >4 to ≤9 h (max. blood draw = 60 mL). HEART and EDACS scores will be prospectively documented. Patients without the first blood draw may be enrolled if the second draw was obtained. Capillary and venous whole blood will undergo Atellica VTLi assay testing, with remaining venous sample processed to plasma and run. All results will be blinded to the clinical care team. Site operators will undergo a 3-day familiarization period. Quality control testing will be performed daily. At 30 ± 3 days, patient mortality status, major adverse cardiac events, and rehospitalizations will be determined. A clinical endpoint adjudication committee, blinded to hs-cTnI VTLi result, will define the final diagnosis. Sensitivity, specificity, and predictive values will describe the assay performance. RESULTS: We expect study completion within 114 weeks of enrollment of the first patient. CONCLUSIONS: It is anticipated that the Atellica VTLi hs-cTnI assay validation study will define a performance equivalent to lab-based hs-cTnI, with results within ∼8 min at the point of care.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Adulto , Humanos , Sistemas de Atención de Punto , Troponina I , Servicio de Urgencia en Hospital , Troponina T , Biomarcadores
2.
Clin Chem Lab Med ; 60(10): 1669-1674, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-35858956

RESUMEN

OBJECTIVES: Patients with acute coronary syndrome (ACS) should be referred promptly to the hospital to reduce mortality and morbidity. Differentiating between low-risk and high-risk patients remains a diagnostic challenge. Point-of-care testing can contribute to earlier disposition decisions for patients excluded from ACS. This study describes the validation of the Atellica® VTLi. Patient-side Immunoassay Analyzer for high-sensitivity troponin point-of-care (POC) analysis. (The Atellica VTLi is not available for sale in the USA. The products/features (mentioned herein) are not commercially available in all countries. Their future availability cannot be guaranteed). METHODS: A total of 152 patients with acute chest pain admitted at the cardiac emergency department (ED) were included in the study. Capillary blood was compared with a whole blood and plasma sample obtained by venipuncture. All samples were analyzed using the Atellica VTLi Patient-side Immunoassay Analyzer; in addition, plasma was analyzed by a central lab immunoassay analyzer. RESULTS: No significant difference was observed between venous whole blood vs. plasma analyzed by the Atellica VTLi Patient-side Immunoassay Analyzer. The difference between capillary blood and venous blood showed a constant bias of 7.1%, for which a correction factor has been implemented. No clinically relevant differences were observed for the capillary POC results compared to plasma analyzed with a standard immunoassay analyzer. CONCLUSIONS: The Atellica VTLi Patient-side Immunoassay Analyzer for high-sensitivity troponin analysis shows equivalent results for all sample types, including capillary blood. No clinically relevant discordances were observed between capillary POC and central laboratory results. With additional studies, this could pave the way towards rapid testing of high-sensitivity troponin in the ambulance or the general practitioner's office without the need for hospitalization of patients with acute chest pain.


Asunto(s)
Síndrome Coronario Agudo , Troponina I , Biomarcadores , Dolor en el Pecho , Servicio de Urgencia en Hospital , Humanos , Sistemas de Atención de Punto
3.
J Appl Lab Med ; 7(4): 971-988, 2022 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-35660917

RESUMEN

BACKGROUND: High-sensitivity cardiac troponin (hs-cTn) assays enable more precise use of traditional diagnostic strategies and earlier rule-out/rule-in at 0/1 h or 0/2 h after presentation of acute myocardial infarction (AMI). Availability of hs-cTn measurements at point-of-care (POC) can improve timely management of AMI patients. A roadmap for regulatory and analytical validation is exemplified with studies with the Atellica VTLi hs-cTnI at POC. METHODS: High-sensitivity performance was assessed with AACC/IFCC expert recommendations. Clinical Laboratory Standards Institute protocols were used for characterizing limit of blank, limit of detection (LoD), limit of quantitation (LoQ), 10% CV, precision, linearity, and analytic specificity with several reagent lots. Bland-Altman, Passing-Bablok, and hematocrit bias plots compared hs-cTnI measurement in lithium-heparin plasma (PL) and whole blood (WB) matrices. RESULTS: LoB was 0.55 ng/L; LoD and LoQ were 1.24 ng/L and 2.1 ng/Lm for PL and 1.60 ng/L and 3.7 ng/L for WB, respectively. The male 99th percentile is 27 ng/L, and female 99th percentile upper reference limit is 18 ng/L; 10% CVs were 6.7 ng/L for PL and 8.9 ng/L for WB. Also ≥50% of hs-cTnI values for healthy cohorts exceeded the LoD, confirming high-sensitivity performance. Linearity spanned from LoQ to 1250 ng/L. Specificity was >90% for 40 potential interferences; no hook effect was detected. WB and PL correlation was WB = 1.02*plasma + 0.3 ng/L (r = 0.996, n = 152). No hs-cTnI association with hematocrit was detected (R2 = 0.003). CONCLUSION: This analytical roadmap showed high-sensitivity performance, good analytic characteristics, and excellent PL and WB agreement for the Atellica VTLi hs-cTnI POC system. Essential clinical performance studies in patients by intended POC users may now commence.


Asunto(s)
Infarto del Miocardio , Troponina I , Femenino , Humanos , Masculino , Diterpenos , Heparina , Litio , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto
4.
Clin Chem Lab Med ; 59(9): 1574-1578, 2021 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-34022125

RESUMEN

OBJECTIVES: High sensitivity (hs) cardiac troponin (cTn) assays are defined per the IFCC Committee on Clinical Application of Cardiac Biomarker (C-CB) by the ability to measure ≥ 50% of concentrations greater than the limit of detection (LoD) with an impression of ≤10% at sex-specific 99th percentiles. Our study determined the sex-specific 99th percentile upper reference limits for males and females utilizing heparinized plasma from AACC universal sample bank for the Siemens point of care (POC) Atellica® VTLi hs-cTnI immunoassay. METHODS: Apparently healthy subjects, included overall 693, males 363, and females 330, following exclusionary surrogate biomarker use of hemoglobin A1c, NT-proBNP, and eGFR, along with statin medication. hs-cTnI was measured in a central laboratory, on multiple POC Atellica® VTLi immunoassay analyzers. The LoD was 1.24 ng/L and the 10%CV concentration was 6.7 ng/L. 99th percentile URLs were determined by the nonparametric (NP) method. RESULTS: Histograms of the hs-cTnI concentrations (ng/L) for males and females were used to visualize the distributions and concentrations in men and women and differed significantly (pre- and post-exclusion, both p <0.001). 99th percentile URLs were: overall 23 ng/L (90% CI 20-32 ng/L); male 27 ng/L (CI 21-37 ng/L); female 18 ng/L (CI 9-78 ng/L). The percentages of subjects having a measurable concentration ≥ the LoD were: overall 83.7%, male 87.3%, female 79.7%. CONCLUSIONS: Our findings show the novel POC Atellica® VTLi hs-cTnI assay meets the designation of a 'high-sensitivity' assay using heparinized plasma.


Asunto(s)
Sistemas de Atención de Punto , Troponina I , Bioensayo/métodos , Femenino , Humanos , Límite de Detección , Masculino , Valores de Referencia , Sensibilidad y Especificidad , Troponina T
5.
Clin Biochem ; 50(4-5): 174-180, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27847339

RESUMEN

OBJECTIVES: Point-of-care cardiac troponin testing with adequate analytical performances has the potential to improve chest pain patients flow in the emergency department. We present the analytical evaluation of the newly developed Philips Minicare cTnI point-of-care immunoassay. DESIGN & METHODS: Li-heparin whole blood and plasma were used to perform analytical studies. The sample type comparison study was performed at 4 different hospitals. The 99th percentile upper reference limit (URL) study was performed using Li-heparin plasma, Li-heparin whole blood and capillary blood samples from 750 healthy adults, aging from 18 to 86years. RESULTS: Limit of the blank, limit of detection and limit of quantitation at 20% coefficient of variation (CV) were determined to be 8.5ng/L, 18ng/L and 38ng/L respectively without significant differences between whole blood and plasma for LoQ. Cross-reactivity and interferences were minimal and no high-dose hook was observed. Total CV was found to be from 7.3% to 12% for cTnI concentrations between 109.6 and 6135.4ng/L. CV at the 99th percentile URL was 18.6%. The sample type comparison study between capillary blood, Li-heparin whole blood and Li-heparin plasma samples demonstrated correlation coefficients between 0.99 and 1.00 with slopes between 1.03 and 1.08. The method comparison between Minicare cTnI and Beckman Coulter Access, AccuTnI+3 demonstrated a correlation coefficient of 0.973 with a slope of 1.09. The 99th percentile URL of a healthy population was calculated to be 43ng/L with no significant difference between genders or sample types. CONCLUSIONS: The Minicare cTnI assay is a sensitive and precise, clinical usable test for determination of cTnI concentration that can be used in a near-patient setting as an aid in the diagnosis of acute myocardial infarction.


Asunto(s)
Análisis Químico de la Sangre/métodos , Troponina I/sangre , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto , Valores de Referencia , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...