Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 307
Filtrar
1.
J Endovasc Ther ; : 15266028241248600, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38708986

RESUMEN

PURPOSE: The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated endovascular aortic repair (FEVAR) and to determine and visualize BECS-associated complications. METHODS: This multicenter retrospective study included patients who underwent FEVAR between 2018 and 2022 in 3 vascular centers participating in the VBX Expand Registry. Patients with at least one visceral artery treated with the VBX and with availability of 2 post-FEVAR computed tomography angiography (CTA) scans (follow-up [FU] 1: 0-6 months; FU2: 9-24 months) were included. The flare geometry of the VBX, including flare-to-fenestration distance, flare-to-fenestration diameter ratio, flare angle, and apposition with the target artery were assessed using a vascular workstation and dedicated CTA applied software. RESULTS: In total, 90 VBX BECS were analyzed in 43 FEVAR patients. The median CTA FU for FU1 and FU2 was 35 days (interquartile range [IQR], 29-51 days) and 14 months (IQR, 13-15 months), respectively. The mean flare-to-fenestration distance was 5.6±2.0 mm on FU1 and remained unchanged at 5.7±2.0 mm on FU2 (p=.417). The flare-to-fenestration diameter ratio was 1.19±0.17 on FU1 and remained unchanged at 1.21±0.19 (p=.206). The mean apposition length was 18.6±5.3 mm on FU1 and remained 18.6±5.3 mm (p=.550). The flare angle was 31°±15° on FU1 and changed to 33°±16° (p=.009). On FU1, the BECS-associated complication rate was 1%, and the BECS-associated reintervention rate was 0%. On FU2, the BECS-associated complication rate was 3%, and the BECS-associated reintervention rate was 1%. CONCLUSIONS: The flare geometry of the VBX bridging stent did not change significantly during 14 months follow-up in this study. Three-dimensional geometric analysis of the flare may contribute to identify the origin of endoleaks and occlusions, but this should be confirmed in a larger study including enough patients and BECS to compare complicated and uncomplicated cases. CLINICAL IMPACT: The three-dimensional flare geometry of the Gore Viabahn VBX BECS was assessed on the first and second postoperative CTA scans, and geometrical changes during this period were identified. For BECS that were diagnosed with a type 3c endoleak or occlusion, the BECS geometry was analyzed to detect geometrical components that were related to the complication. Geometric analysis of the flare may help to better detect and identify the cause of such complications.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38670221

RESUMEN

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiography (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre-operative and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at 1 year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at 1 year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was acquired at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

3.
Ann Vasc Surg ; 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38579908

RESUMEN

INTRODUCTION: The study aims to describe midterm outcomes following treatment of infrarenal abdominal aortic aneurysms (AAAs) with short necks by endosutured aneurysm repair (ESAR) using the Heli-FX EndoAnchor system. METHODS: This is a retrospective study of prospectively collected data from nine vascular surgery departments between June 2010 - December 2019, including treated AAAs with neck lengths ≤ 10mm. The decision for the use of EndoAnchors was made by the treating surgeon or multidisciplinary aortic committee according to each centre's practice. There were two subgroups further assessed according to neck length, A (≥4 and < 7mm) and B (≥7 and ≤10mm). The main outcomes analysed were technical success, freedom from type Ia endoleaks (TIaEL), sac size increase, all-cause (ACM) and aneurysm related mortality (ARM). RESULTS: 76 patients were included in the study, 17 fell into Subgroup A and 59 into subgroup B. Median follow-up for the cohort was 40.5 (IQR 12-61) months. A median of 6 (IQR 3) EndoAnchors were deployed in each subject. Technical success was 86.8% for the total group, 82.4% and 88.1% (p=0.534) for subgroups A and B respectively. Six out of ten (60%) of TIaELs at the completion angiographies showed spontaneous resolution. Cumulative freedom from TIaEL at 3 and 5 years for the total group was 89% and 84% respectively; this was 93% and 74% for subgroup A and 88% at both intervals in subgroup B (p=0.545). In total, there were 7 (9.2%) patients presenting with type Ia endoleaks over the entire study period. Two (11.8%) in subgroup A and 5 (8.5%) in subgroup B (p=0.679). There were more patients with sac regression in subgroup B (subgroup A=6 - 35.3% versus subgroup B=34 - 57.6%, p=0.230) with no statistical significance. ACM was 19 (25%) patients, with no difference (4 - 23.5% versus 15 - 25.4%, p=0.874) between subgroups; whereas ARM occurred in one patient from subgroup A and 3 from subgroup B. CONCLUSIONS: This study demonstrates reasonable outcomes for patients with short-necked AAAs treated by ESAR in terms of type Ia endoleaks up to 5 year follow up. EndoAnchor use should be judiciously evaluated in short necks and may be a reasonable option when anatomical constraints are encountered, mainly for those with 7-10mm neck lengths. Shorter neck length aspects, as indicated by the results from Group A, may be an alternative when no other options are available or feasible.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38552837

RESUMEN

OBJECTIVE: This scoping review summarises health literacy and disease knowledge in patients with abdominal aortic aneurysm (AAA) or peripheral arterial disease (PAD) and the influencing factors. DATA SOURCES: A systematic search was conducted in PubMed, Embase, PsychINFO, and CINAHL covering the period January 2012 to October 2022. REVIEW METHODS: This scoping review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Inclusion criteria encompassed studies addressing health literacy, knowledge, perception, or awareness in patients with AAA or PAD. Two authors independently reviewed abstracts and full texts, resolving any discrepancies through discussion or by consulting a third author for consensus. All article types were included except letters, editorials, study protocols, reviews, and guidelines. No language restrictions were applied. Primary outcomes were health literacy and disease knowledge. Secondary outcomes were factors that could influence this. Quality assessment was done using the Mixed Methods Appraisal Tool (MMAT). RESULTS: The review included 32 articles involving a total of 5 268 patients. Four articles reported health literacy and the rest disease knowledge. Ten studies (31%) met all quality criteria. Twenty studies were quantitative, eight were qualitative, and four were mixed methods studies. The review revealed inadequate health literacy in the majority of patients, and disease knowledge was relatively low among patients with AAA and PAD, with disparities in measures and assessment tools across studies. Factors influencing health literacy and disease knowledge included socioeconomic status, education, income, and employment. CONCLUSION: This scoping review revealed low health literacy and low disease knowledge in patients with AAA and PAD. Standardised health literacy assessment may contribute to improve communication strategies and decision aids to enhance patients' understanding and engagement in healthcare decisions, however further research is needed to prove its merits.

5.
J Clin Med ; 13(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38542032

RESUMEN

Background: Endovascular techniques have gained preference over peripheral arterial bypass surgery due to their minimally invasive nature; however, endovascular treatments often show limited efficacy in arterial segments with a high atherosclerotic load. The use of atherectomy devices enables the removal of calcified plaque material and may promote arterial wall remodeling. This study assessed the technical success, safety, and feasibility of the BYCROSS® atherectomy device in femoropopliteal lesions. Methods: This single-center, retrospective cohort study analyzed elective patients undergoing BYCROSS® atherectomy for chronic peripheral arterial disease from March 2022 to May 2023. Patient data, procedural details, and outcomes were retrospectively collected from electronic patient records. The primary performance endpoints of this study were technical success, complications, and patency rates. Primary safety endpoints included 30-day and short-term major adverse limb events (MALEs), major adverse cardiovascular events (MACEs), and mortality rate. Results: The study included 19 patients (median age, 71 years; 63% male) with Fontaine class IIb (26%), III (21%), or IV (53%). The BYCROSS® atherectomy device was used to treat 22 limbs in the femoropopliteal tract, of which 11 lesions (50%) were occlusions and 11 were stenoses, with a median length of 24 cm (interquartile range: 17-38). Technical success was achieved in all cases: 4.5% required atherectomy only, 50% required additional balloon angioplasties, 41% required balloon angioplasties and stenting, and 4.5% required segments only stenting. Additional treatment of below-the-knee arteries was performed in 12 patients. Procedurally related complications (not limited to the use of the BYCROSS® device) occurred in 23% of limbs, including distal embolization and laceration. At 30 days, mortality was 5%, the MACE rate was 11%, and the MALE rate was 0%. The observed mortality rate was not directly related to the procedure. Patency (<50% restenosis at duplex ultrasound) was 83% at 30 days. Conclusions: The use of the BYCROSS® atherectomy device for the treatment of femoropopliteal lesions appears to be safe and feasible, with high technical success and low MALE and MACE rates in a challenging population with long-segment femoropopliteal lesions. Long-term follow-up in larger patient series is needed to confirm these findings and to determine the durability of this technique.

6.
Lancet Gastroenterol Hepatol ; 9(4): 299-309, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38301673

RESUMEN

BACKGROUND: Mesenteric artery stenting with a bare-metal stent is the current treatment for atherosclerotic chronic mesenteric ischaemia. Long-term patency of bare-metal stents is unsatisfactory due to in-stent intimal hyperplasia. Use of covered stents might improve long-term patency. We aimed to compare the patency of covered stents and bare-metal stents in patients with chronic mesenteric ischaemia. METHODS: We conducted a multicentre, patient-blinded and investigator-blinded, randomised controlled trial including patients with chronic mesenteric ischaemia undergoing mesenteric artery stenting. Six centres in the Netherlands participated in this study, including two national chronic mesenteric ischaemia expert centres. Patients aged 18 years or older were eligible for inclusion when an endovascular mesenteric artery revascularisation was scheduled and a consensus diagnosis of chronic mesenteric ischaemia was made by a multidisciplinary team of gastroenterologists, interventional radiologists, and vascular surgeons. Exclusion criteria were stenosis length of 25 mm or greater, stenosis caused by median arcuate ligament syndrome or vasculitis, contraindication for CT angiography, or previous target vessel revascularisation. Digital 1:1 block randomisation with block sizes of four or six and stratification by inclusion centre was used to allocate patients to undergo stenting with bare-metal stents or covered stents at the start of the procedure. Patients, physicians performing follow-up, investigators, and radiologists were masked to treatment allocation. Interventionalists performing the procedure were not masked. The primary study outcome was the primary patency of covered stents and bare-metal stents at 24 months of follow-up, evaluated in the modified intention-to-treat population, in which stents with missing data for the outcome were excluded. Loss of primary patency was defined as the performance of a re-intervention to preserve patency, or 75% or greater luminal surface area reduction of the target vessel. CT angiography was performed at 6 months, 12 months, and 24 months post intervention to assess patency. The study is registered with ClinicalTrials.gov (NCT02428582) and is complete. FINDINGS: Between April 6, 2015, and March 11, 2019, 158 eligible patients underwent mesenteric artery stenting procedures, of whom 94 patients (with 128 stents) provided consent and were included in the study. 47 patients (62 stents) were assigned to the covered stents group (median age 69·0 years [IQR 63·0-76·5], 28 [60%] female) and 47 patients (66 stents) were assigned to the bare-metal stents group (median age 70·0 years [63·5-76·5], 33 [70%] female). At 24 months, the primary patency of covered stents (42 [81%] of 52 stents) was superior to that of bare-metal stents (26 [49%] of 53; odds ratio [OR] 4·4 [95% CI 1·8-10·5]; p<0·0001). A procedure-related adverse event occurred in 17 (36%) of 47 patients in the covered stents group versus nine (19%) of 47 in the bare-metal stent group (OR 2·4 [95% CI 0·9-6·3]; p=0·065). Most adverse events were related to the access site, including haematoma (five [11%] in the covered stents group vs six [13%] in the bare-metal stents group), pseudoaneurysm (five [11%] vs two [4%]), radial artery thrombosis (one [2%] vs none), and intravascular closure device (none vs one [2%]). Six (13%) patients in the covered stent group versus one (2%) in the bare-metal stent group had procedure-related adverse events not related to the access site, including stent luxation (three [6%] vs none), major bleeding (two (4%) vs none), mesenteric artery perforation (one [2%] vs one [2%]), mesenteric artery dissection (one [2%] vs one [2%]), and death (one [2%] vs none). INTERPRETATION: The findings of this trial support the use of covered stents for mesenteric artery stenting in patients with chronic mesenteric ischaemia. FUNDING: Atrium Maquet Getinge Group.


Asunto(s)
Aterosclerosis , Isquemia Mesentérica , Humanos , Femenino , Anciano , Masculino , Isquemia Mesentérica/cirugía , Constricción Patológica/etiología , Stents/efectos adversos , Arterias Mesentéricas
7.
Eur J Trauma Emerg Surg ; 50(1): 37-47, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38261077

RESUMEN

PURPOSE: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. METHODS: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. RESULTS: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6-3.9°) for rotation, 1.4° (IQR: 0.6-2.9°) for dorsal angulation, 4.7° (IQR: 2.9-5.7°) for radial angulation, and 2.4 mm (IQR: 1.3-2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. CONCLUSION: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.


Asunto(s)
Fracturas Mal Unidas , Fracturas del Radio , Cirugía Asistida por Computador , Humanos , Radio (Anatomía)/diagnóstico por imagen , Radio (Anatomía)/cirugía , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Cirugía Asistida por Computador/métodos , Fracturas Mal Unidas/cirugía , Osteotomía/métodos
8.
Bone Jt Open ; 5(1): 46-52, 2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38240277

RESUMEN

Aims: Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods: A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results: A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion: The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort.

9.
Disabil Rehabil ; 46(2): 257-269, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36656686

RESUMEN

PURPOSE: To systematically review literature on nutritional intake, nutritional status and nutritional interventions, and to study their association with short- and long-term clinical outcomes in people with a major dysvascular lower limb amputation. METHODS: PubMed, Ovid, CINAHL, and The Cochrane Library were searched. Studies were included if nutritional intake, nutritional status, or nutritional interventions in people with a major dysvascular lower limb amputation were analyzed. RESULTS: Of the 3038 unique papers identified, 30 studies were included. Methodological quality was moderate (1 study) or weak (29 studies). Limited information was available on nutritional intake (2 studies) and nutritional interventions (1 study). Nutritional intake and nutritional status were assessed by diverse methods. The percentage of people with a poor nutritional status ranged from 1% to 100%. In some studies, measures of poor nutritional status were associated with adverse short- and long-term clinical outcomes. CONCLUSIONS: The percentage of people with a poor nutritional status is inconclusive in the major dysvascular lower limb amputation population, because of the heterogeneity of the assessment methods used. Some included studies reported a negative association between poor nutritional status and clinical outcomes. However, these results should be interpreted with caution, because of the limited quality of the studies available. Studies high in methodological quality and high in hierarchy of evidence are needed.IMPLICATIONS FOR REHABILITATIONThe proportion of people with a poor nutritional status in the major dysvascular lower limb amputation population is inconclusive.Poor nutritional status seems to affect clinical outcomes negatively.More uniformity in assessment of malnutrition in the major dysvascular lower limb amputation population is needed.


Asunto(s)
Amputación Quirúrgica , Extremidad Inferior , Estado Nutricional , Humanos , Ingestión de Alimentos , Extremidad Inferior/cirugía
10.
Eur J Trauma Emerg Surg ; 50(1): 11-19, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37391531

RESUMEN

PURPOSE: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. METHODS: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. RESULTS: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1). CONCLUSION: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.


Asunto(s)
Fracturas de la Tibia , Fracturas de la Meseta Tibial , Humanos , Fijación Interna de Fracturas , Fracturas de la Tibia/diagnóstico por imagen , Fracturas de la Tibia/cirugía , Tornillos Óseos , Placas Óseas , Impresión Tridimensional
11.
Eur Radiol ; 34(4): 2334-2351, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37672051

RESUMEN

OBJECTIVES: Position- and posture-dependent deformation of the vascular system is a relatively unexplored field. The goal of this scoping review was to create an overview of existing vascular imaging modalities in different body positions and postures and address the subsequent changes in vascular anatomy. METHODS: Scopus, Medline, and Cochrane were searched for literature published between January 1, 2000, and June 30, 2022, incorporating the following categories: image modality, anatomy, orientation, and outcomes. RESULTS: Out of 2446 screened articles, we included 108. The majority of papers used ultrasound (US, n = 74) in different body positions and postures with diameter and cross-sectional area (CSA) as outcome measures. Magnetic resonance imaging (n = 22) and computed tomography (n = 8) were less frequently used but allowed for investigation of other geometrical measures such as vessel curvature and length. The venous system proved more sensitive to postural changes than the arterial system, which was seen as increasing diameters of veins below the level of the heart when going from supine to prone to standing positions, and vice versa. CONCLUSIONS: The influence of body positions and postures on vasculature was predominantly explored with US for vessel diameter and CSA. Posture-induced deformation and additional geometrical features that may be of interest for the (endovascular) treatment of vascular pathologies have been limitedly reported, such as length and curvature of an atherosclerotic popliteal artery during bending of the knee after stent placement. The most important clinical implications of positional changes are found in diagnosis, surgical planning, and follow-up after stent placement. CLINICAL RELEVANCE STATEMENT: This scoping review presents the current state and opportunities of position- and posture-dependent imaging of vascular structures using various imaging modalities that are relevant in the fields of clinical diagnosis, surgical planning, and follow-up after stent placement. KEY POINTS: • The influence of body positions and postures on the vasculature was predominantly investigated with US for vessel diameter and cross-sectional area. • Research into geometrical deformation, such as vessel length and curvature adaptation, that may be of interest for the (endovascular) treatment of vascular pathologies is limited in different positions and postures. • The most important clinical implications of postural changes are found in diagnosis, surgical planning, and follow-up after stent placement.


Asunto(s)
Postura , Tomografía Computarizada por Rayos X , Humanos , Imagen por Resonancia Magnética/métodos , Arteria Poplítea
12.
Ann Vasc Surg ; 99: 166-174, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37924865

RESUMEN

BACKGROUND: Patients with chronic limb threatening ischemia (CLTI) are at high risk for amputation and other cardiovascular adverse events. Nutrition-related symptoms and malnutrition are common in the CLTI population, and lead to worse clinical outcomes. Understanding of the factors influencing nutritional intake is required to determine whether optimization of nutritional intake in this population requires interventions. Therefore, this study aimed to describe perceptions and experiences on nutrition of patients with CLTI, and to identify perceived barriers and facilitators influencing their nutritional intake. METHODS: In this phenomenological qualitative study, individual semi-structured, face-to-face interviews were conducted with patients with CLTI who lived independently. Interviews were transcribed verbatim, and reflexive thematic analysis was performed. RESULTS: Twelve participants were interviewed. Five themes were generated: (1) lack of nutritional risk perception, (2) role of nutrition for health, functioning, and surviving, (3) multiple factors influencing nutritional intake, (4) limited nutritional advice, and (5) no intention to change current nutritional intake. CONCLUSIONS: Patients with CLTI perceive nutritional intake as a necessity to survive and function. Patients express limited risk perception regarding adequate nutritional intake and undernutrition. Nutritional intake is mainly based on non-health-related factors, as habits and taste, and multiple barriers hinder nutritional intake. Patients received no or only limited nutritional advice. Together this leads to an expressed lack of intention to change nutritional intake. Findings of this study stress the urgency for patient-centered nutritional support, to increase nutrition-related knowledge and motivation, to prevent or treat undernutrition, and may improve clinical outcomes in patients with CLTI.


Asunto(s)
Desnutrición , Enfermedad Arterial Periférica , Humanos , Isquemia Crónica que Amenaza las Extremidades , Isquemia , Resultado del Tratamiento , Desnutrición/diagnóstico , Estado Nutricional , Factores de Riesgo , Recuperación del Miembro , Estudios Retrospectivos
13.
Eur Radiol Exp ; 7(1): 82, 2023 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-38123829

RESUMEN

BACKGROUND: Abdominal aortic endoleaks after endovascular aneurysm repair might be position-dependent, therefore undetectable using supine imaging. We aimed to determine the feasibility and benefit of using a low-field tiltable magnetic resonance imaging (MRI) scanner allowing to study patients who can be imaged in both supine and upright positions of endoleaks. METHODS: Ten EVAR patients suspected of endoleak based on ultrasound examination were prospectively included. MRI in upright and supine positions was compared with routine supine computed tomography angiography (CTA). Analysis was performed through (1) subjective image quality assessment by three observers, (2) landmark registration between MRI and CTA scans, (3) Euclidean distances between renal and endograft landmarks, and (4) evaluation of endoleak detection on MRI by a consensus panel. Statistical analysis was performed by one-way repeated measures analysis of variance. RESULTS: The image quality of upright/supine MRI was inferior compared to CTA. Median differences in both renal and endograft landmarks were approximately 6-7 mm between upright and supine MRI and 5-6 mm between supine MRI and CTA. In the proximal sealing zone of the endograft, no differences were found among all three scan types (p = 0.264). Endoleak detection showed agreement between MRI and CTA in 50% of the cases, with potential added value in only one patient. CONCLUSIONS: The benefit of low-field upright MRI for endoleak detection was limited. While MRI assessment was non-inferior to standard CTA in detecting endoleaks in selected cases, improved hardware and sequences are needed to explore the potential of upright MRI in patients with endoleaks. RELEVANCE STATEMENT: Upright low-field MRI has limited clinical value in detecting position-dependent endoleaks; improvements are required to fulfil its potential as a complementary modality in this clinical setting. KEY POINTS: • Upright MRI shows potential for imaging endoleaks in aortic aneurysm patients in different positions. • The image quality of upright MRI is inferior to current techniques. • Upright MRI complements CTA, but lacks accurate deformation measurements for clinical use. • Advancements in hardware and imaging sequences are needed to fully utilise upright MRI capabilities.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Endofuga/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Estudios de Factibilidad , Reparación Endovascular de Aneurismas , Aortografía/métodos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Imagen por Resonancia Magnética
14.
Diagnostics (Basel) ; 13(19)2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37835870

RESUMEN

Nowadays, a substantial number of our patients have multimorbidity, and need treatment for complex diseases [...].

15.
J Clin Med ; 12(18)2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37762994

RESUMEN

BACKGROUND: Conventional measures of fracture displacement have low interobserver reliability. This study introduced a novel 3D method to measure tibial plateau fracture displacement and its impact on functional outcome. METHODS: A multicentre study was conducted on patients who had tibial plateau fracture surgery between 2003 and 2018. Eligible patients had a preoperative CT scan (slice thickness ≤ 1 mm) and received a Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire. A total of 362 patients responded (57%), and assessment of initial and residual fracture displacement was performed via measurement using the 3D gap area (mm2). Patients were divided into four groups based on the 3D gap area size. Differences in functional outcome between these groups were assessed using analysis of variance (ANOVA). Multiple linear regression was used to determine the association between fracture displacement and patient-reported outcome. RESULTS: Functional outcome appeared significantly worse when initial or residual fracture displacement increased. Multivariate linear regression showed that initial 3D gap area (per 100 mm2) was significantly negatively associated with all KOOS subscales: symptoms (-0.9, p < 0.001), pain (-0.0, p < 0.001), ADL (-0.8, p = 0.002), sport (-1.4, p < 0.001), and QoL (-1.1, p < 0.001). In addition, residual gap area was significantly negatively associated with the subscales symptoms (-2.2, p = 0.011), ADL (-2.2, p = 0.014), sport (-2.6, p = 0.033), and QoL (-2.4, p = 0.023). CONCLUSION: A novel 3D measurement method was applied to quantify initial and residual displacement. This is the first study which can reliably classify the degree of displacement and indicates that increasing displacement results in poorer patient-reported functional outcomes.

16.
Sensors (Basel) ; 23(15)2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37571519

RESUMEN

Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Signos Vitales/fisiología , Frecuencia Cardíaca , Frecuencia Respiratoria , Hospitales
17.
BMJ Open ; 13(8): e072875, 2023 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-37643848

RESUMEN

INTRODUCTION: Acute mesenteric ischaemia (AMI) is a life-threatening condition with short-term mortality of up to 80%. The diagnosis of AMI has remained troublesome due to the non-specific clinical presentation, symptoms and laboratory findings. Early unambiguous diagnosis of AMI is critical to prevent progression from reversible to irreversible transmural intestinal damage, thereby decreasing morbidity and improving survival. The present study aims to validate a panel of plasma biomarkers and investigate volatile organic compound (VOC) profiles in exhaled air as a tool to timely and accurately diagnose AMI. METHODS AND ANALYSIS: In this international multicentre prospective observational study, 120 patients (>18 years of age) will be recruited with clinical suspicion of AMI. Clinical suspicion is based on: (1) clinical manifestation, (2) physical examination, (3) laboratory measurements and (4) the physician's consideration to perform a CT scan. The patient's characteristics, repetitive blood samples and exhaled air will be prospectively collected. Plasma levels of mucosal damage markers intestinal fatty acid-binding protein and villin-1, as well as transmural damage marker smooth muscle protein 22-alpha, will be assessed by ELISA. Analysis of VOCs in exhaled air will be performed by gas chromatography time-of-flight mass spectrometry. Diagnosis of AMI will be based on CT, endovascular and surgical reports, clinical findings, and (if applicable) verified by histopathological examination. ETHICS AND DISSEMINATION: The study protocol was approved by the Medical Research Ethics Committee (METC) of Maastricht University Medical Centre+ and Maastricht University (METC azM/UM), the Netherlands (METC19-010) and the Ethics Committee Research UZ/KU Leuven, Belgium (S63500). Executive boards and local METCs of other Dutch participating centres Gelre Ziekenhuizen (Apeldoorn), Medisch Spectrum Twente (Enschede), and University Medical Centre Groningen have granted permission to carry out this study. Study results will be disseminated via open-access peer-reviewed scientific journals and national/international conferences. TRIAL REGISTRATION NUMBER: NCT05194527.


Asunto(s)
Isquemia Mesentérica , Compuestos Orgánicos Volátiles , Humanos , Isquemia Mesentérica/diagnóstico , Centros Médicos Académicos , Biomarcadores , Comités de Ética en Investigación , Estudios Observacionales como Asunto , Estudios Multicéntricos como Asunto
18.
Bone Joint J ; 105-B(9): 1020-1029, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37652442

RESUMEN

Aims: The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a total hip arthroplasty (THA), and to determine predictors for conversion to THA in patients treated nonoperatively for acetabular fractures. Methods: A multicentre cross-sectional study was performed in 170 patients who were treated nonoperatively for an acetabular fracture in three level 1 trauma centres. Using the post-injury diagnostic CT scan, the maximum gap and step-off values in the weightbearing dome were digitally measured by two trauma surgeons. Native hip survival was reported using Kaplan-Meier curves. Predictors for conversion to THA were determined using Cox regression analysis. Results: Of 170 patients, 22 (13%) subsequently received a THA. Native hip survival in patients with a step-off ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 94% vs 70% vs 74%). Native hip survival in patients with a gap ≤ 2 mm, > 2 to 4 mm, or > 4 mm differed at five-year follow-up (respectively: 100% vs 84% vs 78%). Step-off displacement > 2 mm (> 2 to 4 mm hazard ratio (HR) 4.9, > 4 mm HR 5.6) and age > 60 years (HR 2.9) were independent predictors for conversion to THA at follow-up. Conclusion: Patients with minimally displaced acetabular fractures who opt for nonoperative fracture treatment may be informed that fracture displacement (e.g. gap and step-off) up to 2 mm, as measured on CT images, results in limited risk on conversion to THA. Step-off ≥ 2 mm and age > 60 years are predictors for conversion to THA and can be helpful in the shared decision-making process.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Persona de Mediana Edad , Estudios Transversales , Tomografía Computarizada por Rayos X
19.
Eur J Nucl Med Mol Imaging ; 50(13): 3880-3889, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37507493

RESUMEN

PURPOSE: 18F-fluoro-D-deoxyglucose positron emission tomography with low dose and/or contrast enhanced computed tomography ([18F]FDG-PET/CT) scan reveals high sensitivity for the diagnosis of vascular graft and endograft infection (VGEI), but lower specificity. Reporting [18F]FDG-PET/CT scans of suspected VGEI is challenging, reader dependent, and reporting standards are lacking. The aim of this study was to evaluate variability of [18F]FDG-PET/low dose CT (LDCT) reporting of suspected VGEI using a proposed standard reporting format. METHODS: A retrospective cohort study was conducted including all patients with a suspected VGEI (according to the MAGIC criteria) without need for urgent surgical treatment who underwent an additional [18F]FDG-PET/LDCT scan between 2006 and 2022 at a tertiary referral centre. All [18F]FDG-PET/LDCT reports were scored following pre-selected criteria that were formulated based on literature and experts in the field. The aim was to investigate the completeness of [18F]FDG-PET/LDCT reports for diagnosing VGEI (proven according to the MAGIC criteria) and to evaluate if incompleteness of reports influenced the diagnostic accuracy. RESULTS: Hundred-fifty-two patients were included. Median diagnostic interval from the index vascular surgical procedure until [18F]FDG-PET/LDCT scan was 35.5 (7.3-73.3) months. Grafts were in 65.1% located centrally and 34.9% peripherally. Based on the pre-selected reporting criteria, 45.7% of the reports included all items. The least frequently assessed criterion was FDG-uptake pattern (40.6%). Overall, [18F]FDG-PET/LDCT showed a sensitivity of 91%, a specificity of 72%, and an accuracy of 88% when compared to the gold standard (diagnosed VGEI). Lower sensitivity and specificity in reports including ≤ 8 criteria compared to completely evaluated reports were found (83% and 50% vs. 92% and 77%, respectively). CONCLUSION: Less than half of the [18F]FDG-PET/LDCT reports of suspected VGEI met all pre-selected criteria. Incompleteness of reports led to lower sensitivity and specificity. Implementing a recommendation with specific criteria for VGEI reporting is needed in the VGEI-guideline update. This study provides a first recommendation for a concise and complete [18F]FDG-PET/LDCT report in patients with suspected VGEI.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Enfermedades Vasculares , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Fluorodesoxiglucosa F18 , Estudios Retrospectivos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Sensibilidad y Especificidad , Radiofármacos
20.
J Clin Med ; 12(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37297962

RESUMEN

Knowledge about anatomical shape variations in the pelvis is mandatory for selection, fitting, positioning, and fixation in pelvic surgery. The current knowledge on pelvic shape variation mostly relies on point-to-point measurements on 2D X-ray images and computed tomography (CT) slices. Three-dimensional region-specific assessments of pelvic morphology are scarce. Our aim was to develop a statistical shape model of the hemipelvis to assess anatomical shape variations in the hemipelvis. CT scans of 200 patients (100 male and 100 female) were used to obtain segmentations. An iterative closest point algorithm was performed to register these 3D segmentations, so a principal component analysis (PCA) could be performed, and a statistical shape model (SSM) of the hemipelvis was developed. The first 15 principal components (PCs) described 90% of the total shape variation, and the reconstruction ability of this SSM resulted in a root mean square error of 1.58 (95% CI: 1.53-1.63) mm. In summary, an SSM of the hemipelvis was developed, which describes the shape variations in a Caucasian population and is able to reconstruct an aberrant hemipelvis. Principal component analyses demonstrated that, in a general population, anatomical shape variations were mostly related to differences in the size of the pelvis (e.g., PC1 describes 68% of the total shape variation, which is attributed to size). Differences between the male and female pelvis were most pronounced in the iliac wing and pubic rami regions. These regions are often subject to injuries. Future clinical applications of our newly developed SSM may be relevant for SSM-based semi-automatic virtual reconstruction of a fractured hemipelvis as part of preoperative planning. Lastly, for companies, using our SSM might be interesting in order to assess which sizes of pelvic implants should be produced to provide proper-fitting implants for most of the population.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...