Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Int J Radiat Oncol Biol Phys ; 117(1): 45-52, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37037359

RESUMEN

PURPOSE: To compare transarterial chemoembolization delivered with drug eluting beads (TACE-DEB) with stereotactioc body radiation therapy (SBRT) in patients with hepatocellular carcinoma (HCC) in a multicenter randomized trial. METHODS AND MATERIALS: Patients were included if they were eligible for TACE. They could also be recruited if they required treatment prior to liver transplantation. A maximum of four TACE-DEB procedures and ablation after incomplete TACE-DEB were both allowed. SBRT was delivered in six fractions of 8-9Gy. Primary end point was time to progression (TTP). Secondary endpoints were local control (LC), overall survival (OS), response rate (RR), toxicity, and quality of life (QoL). The calculated sample size was 100 patients. RESULTS: Between May 2015 and April 2020, 30 patients were randomized to the study. Due to slow accrual the trial was closed prematurely. Two patients in the SBRT arm were considered ineligible leaving 16 patients in the TACE-DEB arm and 12 in the SBRT arm. Median follow-up was 28.1 months. Median TTP was 12 months for TACEDEB and 19 months for SBRT (p=0.15). Median LC was 12 months for TACE-DEB and >40 months (not reached) for SBRT (p=0.075). Median OS was 36.8 months for TACEDEB and 44.1 months for SBRT (p=0.36). A post-hoc analysis showed 100% for SBRT 1- and 2-year LC, and 54.4% and 43.6% for TACE-DEB (p=0.019). Both treatments resulted in RR>80%. Three episodes of possibly related toxicity grade ≥3 were observed after TACE-DEB. No episodes were observed after SBRT. QoL remained stable after both treatment arms. CONCLUSIONS: In this trial, TTP after TACE-DEB was not significantly improved by SBRT, while SBRT showed higher local antitumoral activity than TACE-DEB, without detrimental effects on OS, toxicity and QoL. To overcome poor accrual in randomized trials that include SBRT, and to generate evidence for including SBRT in treatment guidelines, international cooperation is needed.


Asunto(s)
Carcinoma Hepatocelular , Quimioembolización Terapéutica , Neoplasias Hepáticas , Radiocirugia , Humanos , Radiocirugia/efectos adversos , Carcinoma Hepatocelular/radioterapia , Calidad de Vida , Neoplasias Hepáticas/radioterapia
2.
Front Oncol ; 13: 1114737, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36969072

RESUMEN

Using fiducial-marker-based robotic respiratory tumor tracking, we treated perihilar cholangiocarcinoma patients in the STRONG trial with 15 daily fractions of 4 Gy. For each of the included patients, in-room diagnostic-quality repeat CTs (rCT) were acquired pre- and post-dose delivery in 6 treatment fractions to analyze inter- and intrafraction dose variations. Planning CTs (pCTs) and rCTs were acquired in expiration breath-hold. Analogous to treatment, spine and fiducials were used to register rCTs with pCTs. In each rCT, all OARs were contoured, and the target was rigidly copied from the pCT based on grey values. The rCTs acquired were used to calculate the doses to be delivered through the treatment-unit settings. On average, target doses in rCTs and pCTs were similar. However, due to target displacements relative to the fiducials in rCTs, 10% of the rCTs showed PTV coverage losses of >10%. Although target coverages had been planned below desired values in order to protect OARs, many pre-rCTs contained OAR constraint violations: 44.4% for the 6 major constraints. Most OAR dose differences between pre- and post-rCTs were not statistically significant. The dose deviations observed in repeat CTs represent opportunities for more advanced adaptive approaches to enhancing SBRT treatment quality.

3.
Phys Imaging Radiat Oncol ; 23: 103-108, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35928600

RESUMEN

Background and purpose: Stereotactic body radiotherapy (SBRT) has been proven to be beneficial for several disease sites in the (lower) abdomen. However, the quality of the treatment plan, based on a single planning computed tomography (CT), can be compromised due to large inter-fraction motion of the target and organs at risk (OARs) in this anatomical region. The aim of this study was to investigate the feasibility of online adaptive SBRT treatments on a robotic radiosurgery system and to record estimated total treatment times. Materials and methods: For two disease sites, locally advanced pancreatic cancer (LAPC) and oligometastatic lymph nodes, four patients with repeat CTs were included in the feasibility study. Quick treatment plan templates were generated based on the planning CT and validated by running them on the plan and fraction CTs. For two cases a dummy run was performed and the individual steps were timed. Dose delivery was the largest contributor to the total treatment time, followed by contour adaptation. Results: Running the quick plan templates resulted in plans similar to unrestricted plans, obeying the OAR constraints. The dummy runs showed that online adaptive treatments were completed in 64 to 83 min respectively for oligometastases and LAPC, comparable to other clinically available solutions. Conclusions: This study showed the feasibility of online re-planning for two challenging disease sites within a clinically acceptable time frame on a robotic radiosurgery system, making use of commercially available elements that are not integrated by the vendor.

4.
Front Oncol ; 12: 910792, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35756687

RESUMEN

Purpose: To determine the dosimetric impact of using unedited autocontours in daily plan adaptation of patients with locally advanced pancreatic cancer (LAPC) treated with stereotactic body radiotherapy using tumor tracking. Materials and Methods: The study included 98 daily CT scans of 35 LAPC patients. All scans were manually contoured (MAN), and included the PTV and main organs-at-risk (OAR): stomach, duodenum and bowel. Precision and MIM deformable image registration (DIR) methods followed by contour propagation were used to generate autocontour sets on the daily CT scans. Autocontours remained unedited, and were compared to MAN on the whole organs and at 3, 1 and 0.5 cm from the PTV. Manual and autocontoured OAR were used to generate daily plans using the VOLO™ optimizer, and were compared to non-adapted plans. Resulting planned doses were compared based on PTV coverage and OAR dose-constraints. Results: Overall, both algorithms reported a high agreement between unclipped MAN and autocontours, but showed worse results when being evaluated on the clipped structures at 1 cm and 0.5 cm from the PTV. Replanning with unedited autocontours resulted in better OAR sparing than non-adapted plans for 95% and 84% plans optimized using Precision and MIM autocontours, respectively, and obeyed OAR constraints in 64% and 56% of replans. Conclusion: For the majority of fractions, manual correction of autocontours could be avoided or be limited to the region closest to the PTV. This practice could further reduce the overall timings of adaptive radiotherapy workflows for patients with LAPC.

5.
Cancers (Basel) ; 13(16)2021 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-34439146

RESUMEN

BACKGROUND: In unresectable pCCA, the standard of care is palliative chemotherapy. We investigated the feasibility and safety of adding stereotactic body radiation therapy (SBRT) after chemotherapy. METHODS: Patients with unresectable pCCA, stage T1-T4N0-N1M0, ECOG 0-1, having finished 6-8 cycles of cisplatin and gemcitabine without disease progression were eligible. SBRT was planned in 15 fractions of 3.0-4.5 Gy. The primary endpoints were feasibility (defined as completing SBRT as planned) and toxicity, evaluated within 3 months after SBRT (CTCAE v4.03). A conventional "3 + 3" design was used, corresponding to a sample size of 6 patients. Dose-limiting toxicity (DLT) was defined as grade ≥ 4 hepatobiliary or grade ≥ 3 gastrointestinal toxicity. The secondary endpoints, measured from the start of radiotherapy, were local control, progression-free survival, overall survival, and quality of life (QoL). ClinicalTrials.gov identifier: NCT03307538. RESULTS: Six patients were enrolled between November 2017 and March 2020. SBRT was delivered as planned. All patients were treated with 60Gy (15 × 4.0Gy). No SBRT-related DLT was observed. The most common grade ≥ 3 toxicity was cholangitis (n = 5). The median follow-up was 14 months. The 12-month local control rate was 80%. We observed no substantial changes in QoL. CONCLUSION: In patients with unresectable pCCA with stable disease after palliative chemotherapy, adding SBRT is feasible and safe. The observed local control merits an additional evaluation of effectiveness.

6.
J Appl Clin Med Phys ; 22(3): 35-47, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33475227

RESUMEN

Recently, VOLO™ was introduced as a new optimizer for CyberKnife® planning. In this study, we investigated possibilities to improve treatment plans for MLC-based prostate SBRT with enhanced peripheral zone dose while sparing the urethra, and central lung tumors, compared to existing Sequential Optimization (SO). The primary focus was on reducing OAR doses. For 25 prostate and 25 lung patients treated with SO plans, replanning with VOLO™ was performed with the same planning constraints. For equal PTV coverage, almost all OAR plan parameters were improved with VOLO™. For prostate patients, mean rectum and bladder doses were reduced by 34.2% (P < 0.001) and 23.5% (P < 0.001), with reductions in D0.03cc of 3.9%, 11.0% and 3.1% for rectum, mucosa and bladder (all P ≤ 0.01). Urethra D5% and D10% were 3.8% and 3.0% lower (P ≤ 0.002). For lung patients, esophagus, main bronchus, trachea, and spinal cord D0.03cc was reduced by 18.9%, 11.1%, 16.1%, and 13.2%, respectively (all P ≤ 0.01). Apart from the dosimetric advantages of VOLO™ planning, average reductions in MU, numbers of beams and nodes for prostate/lung were 48.7/32.8%, 26.5/7.9% and 13.4/7.9%, respectively (P ≤ 0.003). VOLO™ also resulted in reduced delivery times with mean/max reductions of: 27/43% (prostate) and 15/41% (lung), P  < 0.001. Planning times reduced from 6 h to 1.1 h and from 3 h to 1.7 h for prostate and lung, respectively. The new VOLO™ planning was highly superior to SO planning in terms of dosimetric plan quality, and planning and delivery times.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Procedimientos Quirúrgicos Robotizados , Humanos , Masculino , Órganos en Riesgo , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
7.
Strahlenther Onkol ; 194(9): 843-854, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29802435

RESUMEN

PURPOSE: To investigate the quality of treatment plans of spinal radiosurgery derived from different planning and delivery systems. The comparisons include robotic delivery and intensity modulated arc therapy (IMAT) approaches. Multiple centers with equal systems were used to reduce a bias based on individual's planning abilities. The study used a series of three complex spine lesions to maximize the difference in plan quality among the various approaches. METHODS: Internationally recognized experts in the field of treatment planning and spinal radiosurgery from 12 centers with various treatment planning systems participated. For a complex spinal lesion, the results were compared against a previously published benchmark plan derived for CyberKnife radiosurgery (CKRS) using circular cones only. For two additional cases, one with multiple small lesions infiltrating three vertebrae and a single vertebra lesion treated with integrated boost, the results were compared against a benchmark plan generated using a best practice guideline for CKRS. All plans were rated based on a previously established ranking system. RESULTS: All 12 centers could reach equality (n = 4) or outperform (n = 8) the benchmark plan. For the multiple lesions and the single vertebra lesion plan only 5 and 3 of the 12 centers, respectively, reached equality or outperformed the best practice benchmark plan. However, the absolute differences in target and critical structure dosimetry were small and strongly planner-dependent rather than system-dependent. Overall, gantry-based IMAT with simple planning techniques (two coplanar arcs) produced faster treatments and significantly outperformed static gantry intensity modulated radiation therapy (IMRT) and multileaf collimator (MLC) or non-MLC CKRS treatment plan quality regardless of the system (mean rank out of 4 was 1.2 vs. 3.1, p = 0.002). CONCLUSIONS: High plan quality for complex spinal radiosurgery was achieved among all systems and all participating centers in this planning challenge. This study concludes that simple IMAT techniques can generate significantly better plan quality compared to previous established CKRS benchmarks.


Asunto(s)
Benchmarking , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Columna Vertebral , Vértebras Torácicas , Anciano , Algoritmos , Fraccionamiento de la Dosis de Radiación , Humanos , Recurrencia Local de Neoplasia/radioterapia , Órganos en Riesgo , Radiocirugia/instrumentación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/instrumentación , Reirradiación , Procedimientos Quirúrgicos Robotizados/instrumentación , Neoplasias de la Columna Vertebral/radioterapia , Neoplasias de la Columna Vertebral/secundario , Vértebras Torácicas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...