Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Aging Cell ; : e14160, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38566432

RESUMEN

Age and elevated intraocular pressure (IOP) are the two primary risk factors for glaucoma, an optic neuropathy that is the leading cause of irreversible blindness. In most people, IOP is tightly regulated over a lifetime by the conventional outflow tissues. However, the mechanistic contributions of age to conventional outflow dysregulation, elevated IOP and glaucoma are unknown. To address this gap in knowledge, we studied how age affects the morphology, biomechanical properties and function of conventional outflow tissues in C57BL/6 mice, which have an outflow system similar to humans. As reported in humans, we observed that IOP in mice was maintained within a tight range over their lifespan. Remarkably, despite a constellation of age-related changes to the conventional outflow tissues that would be expected to hinder aqueous drainage and impair homeostatic function (decreased cellularity, increased pigment accumulation, increased cellular senescence and increased stiffness), outflow facility, a measure of conventional outflow tissue fluid conductivity, was stable with age. We conclude that the murine conventional outflow system has significant functional reserve in healthy eyes. However, these age-related changes, when combined with other underlying factors, such as genetic susceptibility, are expected to increase risk for ocular hypertension and glaucoma.

2.
bioRxiv ; 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-38106150

RESUMEN

Age and elevated intraocular pressure (IOP) are the two primary risk factors for glaucoma, an optic neuropathy that is the leading cause of irreversible blindness. In most people, IOP is tightly regulated over a lifetime by the conventional outflow tissues. However, the mechanistic contributions of age to conventional outflow dysregulation, elevated IOP and glaucoma are unknown. To address this gap in knowledge, we studied how age affects the morphology, biomechanical properties and function of conventional outflow tissues in C57BL/6 mice, which have an outflow system similar to humans. As reported in humans, we observed that IOP in mice was maintained within a tight range over their lifespan. Remarkably, despite a constellation of age-related changes to the conventional outflow tissues that would be expected to hinder aqueous drainage and impair homeostatic function (decreased cellularity, increased pigment accumulation, increased cellular senescence and increased stiffness), outflow facility, a measure of conventional outflow tissue fluid conductivity, was stable with age. We conclude that the murine conventional outflow system has significant functional reserve in healthy eyes. However, these age-related changes, when combined with other underlying factors, such as genetic susceptibility, are expected to increase risk for ocular hypertension and glaucoma.

3.
ACS Meas Sci Au ; 3(2): 120-126, 2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37090258

RESUMEN

Fast scan cyclic voltammetry (FSCV) at carbon fiber microelectrodes (CFMs) is a method traditionally used for real-time quantification of neurotransmitters in biological systems. Reliable calibration of CFMs is essential for converting FSCV signals to analyte concentrations and generally employs flow injection analysis (FIA) performed with flow cells fabricated in-house. Such FSCV FIA cells often require significant and ongoing troubleshooting with pulsing, leaking, flow inconsistencies and dead volume being major causes of common challenges. In this work, we address these issues by creating a robust, plug-and-play FSCV flow cell. This novel design permits reproducible, high-precision, and stable flow injection profiles using low-cost materials to improve FSCV calibration. The ready-to-print computer-aided designs and hardware list are provided.

4.
Sci Adv ; 9(16): eadf6537, 2023 04 21.
Artículo en Inglés | MEDLINE | ID: mdl-37075118

RESUMEN

Approximately 80 million people globally are affected by glaucoma, with a projected increase to over 110 million by 2040. Substantial issues surrounding patient compliance remain with topical eye drops, and up to 10% of patients become treatment resistant, putting them at risk of permanent vision loss. The major risk factor for glaucoma is elevated intraocular pressure, which is regulated by the balance between the secretion of aqueous humor and the resistance to its flow across the conventional outflow pathway. Here, we show that adeno-associated virus 9 (AAV9)-mediated expression of matrix metalloproteinase-3 (MMP-3) can increase outflow in two murine models of glaucoma and in nonhuman primates. We show that long-term AAV9 transduction of the corneal endothelium in the nonhuman primate is safe and well tolerated. Last, MMP-3 increases outflow in donor human eyes. Collectively, our data suggest that glaucoma can be readily treated with gene therapy-based methods, paving the way for deployment in clinical trials.


Asunto(s)
Glaucoma , Presión Intraocular , Humanos , Animales , Ratones , Metaloproteinasa 3 de la Matriz/metabolismo , Glaucoma/genética , Glaucoma/terapia , Glaucoma/metabolismo , Humor Acuoso/metabolismo , Terapia Genética
5.
Exp Eye Res ; 220: 109103, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35525299

RESUMEN

The key risk factor for glaucoma is elevation of intraocular pressure (IOP) and alleviating it is the only effective therapeutic approach to inhibit further vision loss. IOP is regulated by the flow of aqueous humour across resistive tissues, and a reduction in outflow facility, is responsible for the IOP elevation in glaucoma. Measurement of outflow facility is therefore important when investigating the pathophysiology of glaucoma and testing candidate treatments for lowering IOP. Due to similar anatomy and response to pharmacological treatments, mouse eyes are a common model of human aqueous humour dynamics. The ex vivo preparation, in which an enucleated mouse eye is mounted in a temperature controlled bath and cannulated, has been well characterised and is widely used. The postmortem in situ model, in which the eyes are perfused within the cadaver, has received relatively little attention. In this study, we investigate the postmortem in situ model using the iPerfusion system, with a particular focus on i) the presence or absence of pressure-independent flow, ii) the effect of evaporation on measured flow rates and iii) the magnitude and pressure dependence of outflow facility and how these properties are affected by postmortem changes. Measurements immediately after cannulation and following multi-pressure facility measurement demonstrated negligible pressure-independent flow in postmortem eyes, in contrast to assumptions made in previous studies. Using a humidity chamber, we investigated whether the humidity of the surrounding air would influence measured flow rates. We found that at room levels of humidity, evaporation of saline droplets on the eye resulted in artefactual flow rates with a magnitude comparable to outflow, which were eliminated by a high relative humidity (>85%) environment. Average postmortem outflow facility was ∼4 nl/min/mmHg, similar to values observed ex vivo, irrespective of whether a postmortem delay was introduced prior to cannulation. The intra-animal variability of measured outflow facility values was also reduced relative to previous ex vivo data. The pressure-dependence of outflow facility was reduced in the postmortem relative to ex vivo model, and practically eliminated when eyes were cannulated >40 min after euthanisation. Overall, our results indicate that the moderately increased technical complexity associated with postmortem perfusion provides reduced variability and reduced pressure-dependence in outflow facility, when experimental conditions are properly controlled.


Asunto(s)
Humor Acuoso , Glaucoma , Animales , Humor Acuoso/fisiología , Presión Intraocular , Ratones , Perfusión/métodos , Tonometría Ocular , Malla Trabecular
6.
Invest Ophthalmol Vis Sci ; 63(2): 12, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35129590

RESUMEN

Due to their similarities in anatomy, physiology, and pharmacology to humans, mice are a valuable model system to study the generation and mechanisms modulating conventional outflow resistance and thus intraocular pressure. In addition, mouse models are critical for understanding the complex nature of conventional outflow homeostasis and dysfunction that results in ocular hypertension. In this review, we describe a set of minimum acceptable standards for developing, characterizing, and utilizing mouse models of open-angle ocular hypertension. We expect that this set of standard practices will increase scientific rigor when using mouse models and will better enable researchers to replicate and build upon previous findings.


Asunto(s)
Humor Acuoso/fisiología , Consenso , Glaucoma/metabolismo , Presión Intraocular/fisiología , Hipertensión Ocular/metabolismo , Malla Trabecular/metabolismo , Animales , Modelos Animales de Enfermedad , Glaucoma/fisiopatología , Ratones , Hipertensión Ocular/fisiopatología , Tonometría Ocular
7.
Invest Ophthalmol Vis Sci ; 63(1): 21, 2022 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-35040876

RESUMEN

Purpose: Rodent and primate models are commonly used in glaucoma research; however, both have their limitations. The tree shrew (Tupaia belangeri) is an emerging animal model for glaucoma research owing in part to having a human-like optic nerve head anatomy, specifically a collagenous load-bearing lamina. However, the anterior segment anatomy and function have not been extensively studied in the tree shrew. Thus, the purpose of this study was to provide the first detailed examination of the anterior segment anatomy and aqueous outflow facility in the tree shrew. Methods: Aqueous outflow dynamics were measured in five ostensibly normal eyes from three tree shrews using the iPerfusion system over a range of pressures. Gross histological assessment and immunohistochemistry were performed to characterize anterior segment anatomy and to localize several key molecules related to aqueous outflow. Results: Anterior segment anatomy in tree shrews is similar to humans, demonstrating a scleral spur, a multilayered trabecular meshwork and a circular Schlemm's canal with a single lumen. Average outflow facility was 0.193 µL/min/mm Hg (95% confidence interval, 0.153-0.244), and was stable over time. Outflow facility was more similar between contralateral eyes (approximately 5% average difference) than between eyes of different animals. No significant dependence of outflow facility on time or pressure was detected (pressure-flow nonlinearity parameter of 0.01 (95% % confidence interval, -0.29 to 0.31 CI µL/min/mm Hg). Conclusions: These studies lend support to the usefulness of the tree shrew as a novel animal model in anterior segment glaucoma and pharmacology research. The tree shrew's cost, load-bearing collagenous lamina cribrosa, and lack of washout or anterior chamber deepening provides a distinct experimental and anatomic advantage over the current rodent and nonhuman primate models used for translational research.


Asunto(s)
Segmento Anterior del Ojo/anatomía & histología , Humor Acuoso/fisiología , Glaucoma/patología , Presión Intraocular/fisiología , Animales , Segmento Anterior del Ojo/fisiología , Modelos Animales de Enfermedad , Femenino , Glaucoma/metabolismo , Masculino , Tupaia
8.
Biomech Model Mechanobiol ; 21(1): 335-361, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34907491

RESUMEN

Modelling blood flow in microvascular networks is challenging due to the complex nature of haemorheology. Zero- and one-dimensional approaches cannot reproduce local haemodynamics, and models that consider individual red blood cells (RBCs) are prohibitively computationally expensive. Continuum approaches could provide an efficient solution, but dependence on a large parameter space and scarcity of experimental data for validation has limited their application. We describe a method to assimilate experimental RBC velocity and concentration data into a continuum numerical modelling framework. Imaging data of RBCs were acquired in a sequentially bifurcating microchannel for various flow conditions. RBC concentration distributions were evaluated and mapped into computational fluid dynamics simulations with rheology prescribed by the Quemada model. Predicted velocities were compared to particle image velocimetry data. A subset of cases was used for parameter optimisation, and the resulting model was applied to a wider data set to evaluate model efficacy. The pre-optimised model reduced errors in predicted velocity by 60% compared to assuming a Newtonian fluid, and optimisation further reduced errors by 40%. Asymmetry of RBC velocity and concentration profiles was demonstrated to play a critical role. Excluding asymmetry in the RBC concentration doubled the error, but excluding spatial distributions of shear rate had little effect. This study demonstrates that a continuum model with optimised rheological parameters can reproduce measured velocity if RBC concentration distributions are known a priori. Developing this approach for RBC transport with more network configurations has the potential to provide an efficient approach for modelling network-scale haemodynamics.


Asunto(s)
Hemodinámica , Hidrodinámica , Velocidad del Flujo Sanguíneo , Eritrocitos , Reología/métodos
9.
Front Med Technol ; 3: 707826, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35047946

RESUMEN

There has existed a severe ventilator deficit in much of the world for many years, due in part to the high cost and complexity of traditional ICU ventilators. This was highlighted and exacerbated by the emergence of the COVID-19 pandemic, during which the increase in ventilator production rapidly overran the global supply chains for components. In response, we propose a new approach to ventilator design that meets the performance requirements for COVID-19 patients, while using components that minimise interference with the existing ventilator supply chains. The majority of current ventilator designs use proportional valves and flow sensors, which remain in short supply over a year into the pandemic. In the proposed design, the core components are on-off valves. Unlike proportional valves, on-off valves are widely available, but accurate control of ventilation using on-off valves is not straightforward. Our proposed solution combines four on-off valves, a two-litre reservoir, an oxygen sensor and two pressure sensors. Benchtop testing of a prototype was performed with a commercially available flow analyser and test lungs. We investigated the accuracy and precision of the prototype using both compressed gas supplies and a portable oxygen concentrator, and demonstrated the long-term durability over 15 days. The precision and accuracy of ventilation parameters were within the ranges specified in international guidelines in all tests. A numerical model of the system was developed and validated against experimental data. The model was used to determine usable ranges of valve flow coefficients to increase supply chain flexibility. This new design provides the performance necessary for the majority of patients that require ventilation. Applications include COVID-19 as well as pneumonia, influenza, and tuberculosis, which remain major causes of mortality in low and middle income countries. The robustness, energy efficiency, ease of maintenance, price and availability of on-off valves are all advantageous over proportional valves. As a result, the proposed ventilator design will cost significantly less to manufacture and maintain than current market designs and has the potential to increase global ventilator availability.

10.
Prog Retin Eye Res ; 83: 100922, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33253900

RESUMEN

Catalyzed by endothelial nitric oxide (NO) synthase (eNOS) activity, NO is a gaseous signaling molecule maintaining endothelial and cardiovascular homeostasis. Principally, NO regulates the contractility of vascular smooth muscle cells and permeability of endothelial cells in response to either biochemical or biomechanical cues. In the conventional outflow pathway of the eye, the smooth muscle-like trabecular meshwork (TM) cells and Schlemm's canal (SC) endothelium control aqueous humor outflow resistance, and therefore intraocular pressure (IOP). The mechanisms by which outflow resistance is regulated are complicated, but NO appears to be a key player as enhancement or inhibition of NO signaling dramatically affects outflow function; and polymorphisms in NOS3, the gene that encodes eNOS modifies the relation between various environmental exposures and glaucoma. Based upon a comprehensive review of past foundational studies, we present a model whereby NO controls a feedback signaling loop in the conventional outflow pathway that is sensitive to changes in IOP and its oscillations. Thus, upon IOP elevation, the outflow pathway tissues distend, and the SC lumen narrows resulting in increased SC endothelial shear stress and stretch. In response, SC cells upregulate the production of NO, relaxing neighboring TM cells and increasing permeability of SC's inner wall. These IOP-dependent changes in the outflow pathway tissues reduce the resistance to aqueous humor drainage and lower IOP, which, in turn, diminishes the biomechanical signaling on SC. Similar to cardiovascular pathogenesis, dysregulation of the eNOS/NO system leads to dysfunctional outflow regulation and ocular hypertension, eventually resulting in primary open-angle glaucoma.


Asunto(s)
Glaucoma de Ángulo Abierto , Presión Intraocular , Humor Acuoso , Células Endoteliales , Homeostasis , Humanos , Óxido Nítrico , Malla Trabecular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...