Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 62(13): 5312-5326, 2017 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-28557798

RESUMEN

The incidence of small renal masses (SRMs) sized <4 cm has increased over the decades (as co-findings/or due to introduction of cross sectional imaging). Currently, partial nephrectomy (PN) or watchful waiting is advised in these patients. Ultimately, 80-90% of these SRMs require surgical treatment and PN is associated with a 15% complication rate. In this aging population, with possible comorbidities and poor health condition, both PN and watchful waiting are non-ideal treatment options. This resulted in an increased need for early, non-invasive treatment strategies such as MR-guided high intensity focused ultrasound (MR-HIFU). (i) To investigate the feasibility of creating a confluent lesion in the kidney using respiratory-gated MR-HIFU under clinical conditions in a pre-clinical study and (ii) to evaluate the reproducibility of the MR-HIFU ablation strategy. Healthy pigs (n = 10) under general anesthesia were positioned on a clinical MR-HIFU system with integrated cooling. A honeycomb pattern of seven overlapping ablation cells (4 × 4 × 10 mm3, 450 W, <30 s) was ablated successively in the cortex of the porcine kidney. Both MR thermometry and acoustic energy delivery were respiratory gated using a pencil beam navigator on the contralateral kidney. The non-perfused volume (NPV) was visualized after the last sonication by contrast-enhanced (CE) T 1-weighted MR (T 1 w) imaging. Cell viability staining was performed to visualize the extent of necrosis. RESULTS: a median NPV of 0.62 ml was observed on CE-T 1 w images (IQR 0.58-1.57 ml, range 0.33-2.75 ml). Cell viability staining showed a median damaged volume of 0.59 ml (IQR 0.24-1.35 ml, range 0-4.1 ml). Overlooking of the false rib, shivering of the pig, and too large depth combined with a large heat-sink effect resulted in insufficient heating in 4 cases. The NPV and necrosed volume were confluent in all cases in which an ablated volume could be observed. Our results demonstrated the feasibility of creating a confluent volume of ablated kidney cortical tissue in vivo with MR-HIFU on a clinically available system using respiratory gating and near-field cooling and showed its reproducibility.


Asunto(s)
Técnicas de Ablación/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Riñón/diagnóstico por imagen , Riñón/cirugía , Imagen por Resonancia Magnética , Cirugía Asistida por Computador/métodos , Porcinos , Animales , Femenino , Reproducibilidad de los Resultados , Temperatura
2.
J Ther Ultrasound ; 5: 8, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28194274

RESUMEN

BACKGROUND: Magnetic resonance high-intensity focused ultrasound (MR-HIFU) treatment for uterine fibroids is rapidly gaining popularity as a treatment modality. This procedure is generally uncomfortable, painful, and requires minimal or absence of movement and an MR-HIFU synchronised breathing pattern of the patient. Procedural sedation and analgesia protocols have become the standard practice in interventional radiology departments worldwide. The aim of this study was to explore if a sedation regimen with low-dose propofol and ketamine performed by trained non-medical sedation practitioners could result in relief of discomfort for the patient and in adequate working conditions for MR-HIFU treatment for uterine fibroids. METHODS: In this study, conducted from August 2013 until November 2014, 20 patients were subjected to MR-HIFU treatment of uterine fibroids. Patients were deeply sedated using intravenous propofol and esketamine according to a standardised hospital protocol to allow synchronisation of the breathing pattern to the MR-HIFU. The quality of sedation for MR-HIFU and complications were recorded and analysed. The side effects of the sedation technique, the propofol and esketamine consumption rate, the duration of recovery, and patient satisfaction after 24 h were examined. RESULTS: A total of 20 female patients (mean age 42.4 [range 32-53] years) were enrolled. Mean propofol/esketamine dose was 1309 mg/39.5 mg (range 692-1970 mg/ 23.6-87.9 mg). Mean procedure time was 269 min (range 140-295 min). Application of the sedation protocol resulted in a regular breathing pattern, which could be synchronised with the MR-HIFU procedures without delay. The required treatment was completed in all cases. There were no major adverse events. Hypoxemia (oxygen desaturation <92%) and hallucinations were not observed. CONCLUSIONS: The use of a specific combination of IV propofol and esketamine for procedural sedation and analgesia reduced the discomfort and pain during MR-guided HIFU treatments of uterine fibroids. The resulting regular breathing pattern allowed for easy synchronisation of the MR-HIFU procedure. Based on our results, esketamine and propofol sedation performed by trained non-medical sedation practitioners is feasible and safe, has a low risk of major adverse events, and has a short recovery time, avoiding a session of general anaesthesia.

3.
Phys Med Biol ; 61(3): 1057-77, 2016 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-26757987

RESUMEN

This study investigated whether an MR-guided pulsed HIFU ablation strategy could be implemented under clinical conditions, using a transducer designed for uterine fibroid ablation, to obtain an ablation rate that is sufficiently high for clinical abdominal HIFU therapy in highly perfused organs. A pulsed HIFU ablation strategy, aimed at increasing the energy absorption in the HIFU focal area by local shock wave formation in the non-linear pressure regime, was compared to an energy-equivalent continuous wave sonication strategy in the linear pressure regime. Both ablation strategies were used for transcutaneous sonication of pre-defined treatment cells in the livers of 5 pigs in vivo. Temperature evolution in both the target area as well as the pre-focal muscle layer was monitored simultaneously using MR thermometry. Local energy absorption and thermal dose volumes were shown to be increased using the pulsed ablation strategy, while preserving healthy tissue in the near field of the acoustic beam. Respiratory motion compensation of both acoustic energy delivery and MR thermometry was applied through gating based on MR navigator echoes. Histopathology showed that confluent vacuolated thermal lesions were created when the pulsed ablation strategy was used. Additionally, it was shown that the heat sink effect caused by the presence of larger vessels could be overcome. The pulsed HIFU ablation strategy achieved an ablation rate of approximately 4 ml per hour in the in vivo porcine liver, without causing undesired damage to healthy tissues in the near field.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Hígado/cirugía , Imagen por Resonancia Magnética/métodos , Sonicación/métodos , Animales , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...