Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Mayo Clin Proc Innov Qual Outcomes ; 7(5): 499-513, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37859995

RESUMEN

Objective: To examine the association of COVID-19 convalescent plasma transfusion with mortality and the differences between subgroups in hospitalized patients with COVID-19. Patients and Methods: On October 26, 2022, a systematic search was performed for clinical studies of COVID-19 convalescent plasma in the literature from January 1, 2020, to October 26, 2022. Randomized clinical trials and matched cohort studies investigating COVID-19 convalescent plasma transfusion compared with standard of care treatment or placebo among hospitalized patients with confirmed COVID-19 were included. The electronic search yielded 3841 unique records, of which 744 were considered for full-text screening. The selection process was performed independently by a panel of 5 reviewers. The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Data were extracted by 5 independent reviewers in duplicate and pooled using an inverse-variance random effects model. The prespecified end point was all-cause mortality during hospitalization. Results: Thirty-nine randomized clinical trials enrolling 21,529 participants and 70 matched cohort studies enrolling 50,160 participants were included in the systematic review. Separate meta-analyses reported that transfusion of COVID-19 convalescent plasma was associated with a decrease in mortality compared with the control cohort for both randomized clinical trials (odds ratio [OR], 0.87; 95% CI, 0.76-1.00) and matched cohort studies (OR, 0.76; 95% CI, 0.66-0.88). The meta-analysis of subgroups revealed 2 important findings. First, treatment with convalescent plasma containing high antibody levels was associated with a decrease in mortality compared with convalescent plasma containing low antibody levels (OR, 0.85; 95% CI, 0.73 to 0.99). Second, earlier treatment with COVID-19 convalescent plasma was associated with a decrease in mortality compared with the later treatment cohort (OR, 0.63; 95% CI, 0.48 to 0.82). Conclusion: During COVID-19 convalescent plasma use was associated with a 13% reduced risk of mortality, implying a mortality benefit for hospitalized patients with COVID-19, particularly those treated with convalescent plasma containing high antibody levels treated earlier in the disease course.

2.
Transfusion ; 63(3): 552-563, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36550639

RESUMEN

BACKGROUND: Previous studies have demonstrated low first-time donor return rates (DRR) following catastrophic events. Little is known, however, about the influence of demographic factors on the DRR of first-time donors during the COVID-19 pandemic, including the unique motivation of COVID-19 convalescent plasma (CCP) donors as compared to non-CCP donors. STUDY DESIGN AND METHODS: Thirteen blood collection organizations submitted deidentified data from first-time CCP and non-CCP donors returning for regular (non-CCP) donations during the pandemic. DRR was calculated as frequencies. Demographic factors associated with returning donors: race/ethnicity, gender, and generation (Gen Z: 19-24, Millennial: 25-40, Gen X: 41-56, and Boomer: ≥57 years old), within the CCP and non-CCP first-time cohorts were compared using chi-square test at p < .05 statistical significance. RESULTS: From March 2020 through December 2021, there were a total of 44,274 first-time CCP and 980,201 first-time non-CCP donors. DRR were 14.6% (range 11.9%-43.3%) and 46.6% (range 10.0%-76.9%) for CCP and non-CCP cohorts, respectively. Age over 40 years (Gen X and Boomers), female gender, and White race were each associated with higher return in both donor cohorts (p < .001). For the non-CCP return donor cohort, the Millennial and Boomers were comparable. CONCLUSION: The findings demonstrate differences in returning donor trends between the two donor cohorts. The motivation of a first-time CCP donor may be different than that of a non-CCP donor. Further study to improve first-time donor engagement would be worthwhile to expand the donor base with a focus on blood donor diversity emphasizing engagement of underrepresented minorities and younger donors.


Asunto(s)
Donantes de Sangre , COVID-19 , Humanos , Femenino , Adulto , Persona de Mediana Edad , Pandemias , COVID-19/epidemiología , COVID-19/terapia , Sueroterapia para COVID-19 , Etnicidad
3.
Sci Rep ; 12(1): 637, 2022 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-35022488

RESUMEN

Convalescent plasma is used to treat COVID-19. There are theoretical concerns about the impact of pro-coagulant factors in convalescent plasma on the coagulation cascade particularly among patients with severe COVID-19. The aim of this study was to evaluate the coagulation profile of COVID-19 convalescent plasma. Clotting times and coagulation factor assays were compared between fresh frozen plasma, COVID-19 convalescent plasma, and pathogen-reduced COVID-19 convalescent plasma. Measurements included prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen, D-dimer, von Willebrand factor activity, von Willebrand factor antigen, coagulation factors II, V, VII-XII, protein S activity, protein C antigen, and alpha-2 plasmin inhibitor. Clotting times and coagulation factor assays were not different between COVID-19 convalescent plasma and fresh frozen plasma, except for protein C antigen. When compared to fresh frozen plasma and regular convalescent plasma, pathogen reduction treatment increased activated partial thromboplastin time and thrombin time, while reducing fibrinogen, coagulation factor II, V, VIII, IX, X, XI, XII, protein S activity, and alpha-2 plasmin inhibitor. The coagulation profiles of human COVID-19 convalescent plasma and standard fresh frozen plasma are not different. Pathogen reduced COVID-19 convalescent plasma is associated with reduction of coagulation factors and a slight prolongation of coagulation times, as anticipated. A key limitation of the study is that the COVID-19 disease course of the convalesced donors was not characterized.


Asunto(s)
Coagulación Sanguínea , COVID-19/sangre , COVID-19/terapia , Adulto , Pruebas de Coagulación Sanguínea , Conservación de la Sangre , Transfusión Sanguínea , Femenino , Humanos , Inmunización Pasiva , Masculino , Persona de Mediana Edad , Sueroterapia para COVID-19
4.
PLoS Med ; 18(12): e1003872, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34928960

RESUMEN

BACKGROUND: The United States (US) Expanded Access Program (EAP) to coronavirus disease 2019 (COVID-19) convalescent plasma was initiated in response to the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of COVID-19. While randomized clinical trials were in various stages of development and enrollment, there was an urgent need for widespread access to potential therapeutic agents. The objective of this study is to report on the demographic, geographical, and chronological characteristics of patients in the EAP, and key safety metrics following transfusion of COVID-19 convalescent plasma. METHODS AND FINDINGS: Mayo Clinic served as the central institutional review board for all participating facilities, and any US physician could participate as a local physician-principal investigator. Eligible patients were hospitalized, were aged 18 years or older, and had-or were at risk of progression to-severe or life-threatening COVID-19; eligible patients were enrolled through the EAP central website. Blood collection facilities rapidly implemented programs to collect convalescent plasma for hospitalized patients with COVID-19. Demographic and clinical characteristics of all enrolled patients in the EAP were summarized. Temporal patterns in access to COVID-19 convalescent plasma were investigated by comparing daily and weekly changes in EAP enrollment in response to changes in infection rate at the state level. Geographical analyses on access to convalescent plasma included assessing EAP enrollment in all national hospital referral regions, as well as assessing enrollment in metropolitan areas and less populated areas that did not have access to COVID-19 clinical trials. From April 3 to August 23, 2020, 105,717 hospitalized patients with severe or life-threatening COVID-19 were enrolled in the EAP. The majority of patients were 60 years of age or older (57.8%), were male (58.4%), and had overweight or obesity (83.8%). There was substantial inclusion of minorities and underserved populations: 46.4% of patients were of a race other than white, and 37.2% of patients were of Hispanic ethnicity. Chronologically and geographically, increases in the number of both enrollments and transfusions in the EAP closely followed confirmed infections across all 50 states. Nearly all national hospital referral regions enrolled and transfused patients in the EAP, including both in metropolitan and in less populated areas. The incidence of serious adverse events was objectively low (<1%), and the overall crude 30-day mortality rate was 25.2% (95% CI, 25.0% to 25.5%). This registry study was limited by the observational and pragmatic study design that did not include a control or comparator group; thus, the data should not be used to infer definitive treatment effects. CONCLUSIONS: These results suggest that the EAP provided widespread access to COVID-19 convalescent plasma in all 50 states, including for underserved racial and ethnic minority populations. The study design of the EAP may serve as a model for future efforts when broad access to a treatment is needed in response to an emerging infectious disease. TRIAL REGISTRATION: ClinicalTrials.gov NCT#: NCT04338360.


Asunto(s)
COVID-19/terapia , Ensayos de Uso Compasivo/métodos , Necesidades y Demandas de Servicios de Salud/estadística & datos numéricos , Sistemas de Distribución en Hospital/organización & administración , Sistema de Registros , Reacción a la Transfusión/complicaciones , Reacción a la Transfusión/epidemiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/epidemiología , Minorías Étnicas y Raciales , Femenino , Humanos , Inmunización Pasiva/efectos adversos , Inmunización Pasiva/métodos , Pacientes Internos , Masculino , Área sin Atención Médica , Persona de Mediana Edad , Pandemias , Seguridad del Paciente , SARS-CoV-2 , Resultado del Tratamiento , Estados Unidos , Sueroterapia para COVID-19
5.
Nat Commun ; 12(1): 4864, 2021 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-34381030

RESUMEN

Successful therapeutics and vaccines for coronavirus disease 2019 (COVID-19) have harnessed the immune response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Evidence that SARS-CoV-2 exists as locally evolving variants suggests that immunological differences may impact the effectiveness of antibody-based treatments such as convalescent plasma and vaccines. Considering that near-sourced convalescent plasma likely reflects the antigenic composition of local viral strains, we hypothesize that convalescent plasma has a higher efficacy, as defined by death within 30 days of transfusion, when the convalescent plasma donor and treated patient were in close geographic proximity. Results of a series of modeling techniques applied to approximately 28,000 patients from the Expanded Access to Convalescent Plasma program (ClinicalTrials.gov number: NCT04338360) support this hypothesis. This work has implications for the interpretation of clinical studies, the ability to develop effective COVID-19 treatments, and, potentially, for the effectiveness of COVID-19 vaccines as additional locally-evolving variants continue to emerge.


Asunto(s)
COVID-19/terapia , Plasma/inmunología , Adolescente , Adulto , Anciano , Anticuerpos Antivirales/inmunología , Especificidad de Anticuerpos , Variación Antigénica , Donantes de Sangre , COVID-19/mortalidad , Femenino , Humanos , Inmunización Pasiva/mortalidad , Masculino , Persona de Mediana Edad , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Resultado del Tratamiento , Estados Unidos/epidemiología , Adulto Joven , Sueroterapia para COVID-19
6.
Transfusion ; 61(9): 2668-2676, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34227689

RESUMEN

BACKGROUND: Although the safety and therapeutic efficacy of COVID-19 convalescent plasma (CCP) has been extensively evaluated, the safety of CCP donation has not been explored in a multi-institutional context. STUDY DESIGN AND METHODS: Nine blood collection organizations (BCOs) participated in a multi-institutional donor hemovigilance effort to assess the safety of CCP donation. Donor adverse events (DAEs) were defined according to the Standard for Surveillance of Complications Related to Blood Donation, and severity was assessed using the severity grading tool. Multivariate analysis was performed to determine attributes associated with DAE severity. RESULTS: The overall DAE rate was 37.7 per 1000 donations. Repeat apheresis and apheresis-naïve donors experienced adverse event rates of 19.9 and 49.8 per 1000 donations, respectively. Female donors contributed 51.9% of CCP donations with a DAE rate of 49.4 per 1000 donations. The DAE rate for male donors was 27.4 per 1000 donations. Vasovagal reactions accounted for over half of all reported DAEs (51.1%). After adjustment, volume of CCP donated was associated with vasovagal reaction severity (odds ratio [OR] 6.5, 95% confidence interval [CI] 2.5-17.1). Donor age and donation history were also associated with DAE severity. Considerable differences in DAE types and rates were observed across the participating BCOs despite the use of standardized hemovigilance definitions. CONCLUSION: The safety of CCP donation appears comparable to that of conventional apheresis plasma donation with similar associated risk factors for DAE types and severity.


Asunto(s)
Donantes de Sangre , Seguridad de la Sangre , COVID-19/sangre , COVID-19/inmunología , SARS-CoV-2/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , COVID-19/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Vigilancia en Salud Pública , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estados Unidos/epidemiología , Adulto Joven
7.
medRxiv ; 2021 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-33851175

RESUMEN

BACKGROUND: The United States (US) Expanded Access Program (EAP) to COVID-19 convalescent plasma was initiated in response to the rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease-2019 (COVID-19). While randomized clinical trials were in various stages of development and enrollment, there was an urgent need for widespread access to potential therapeutic agents particularly for vulnerable racial and ethnic minority populations who were disproportionately affected by the pandemic. The objective of this study is to report on the demographic, geographic, and chronological access to COVID-19 convalescent plasma in the US via the EAP. METHODS AND FINDINGS: Mayo Clinic served as the central IRB for all participating facilities and any US physician could participate as local physician-principal investigator. Registration occurred through the EAP central website. Blood banks rapidly developed logistics to provide convalescent plasma to hospitalized patients with COVID-19. Demographic and clinical characteristics of all enrolled patients in the EAP were summarized. Temporal trends in access to COVID-19 convalescent plasma were investigated by comparing daily and weekly changes in EAP enrollment in response to changes in infection rate on a state level. Geographical analyses on access to convalescent plasma included assessing EAP enrollment in all national hospital referral regions as well as assessing enrollment in metropolitan and less populated areas which did not have access to COVID-19 clinical trials.From April 3 to August 23, 2020, 105,717 hospitalized patients with severe or life-threatening COVID-19 were enrolled in the EAP. A majority of patients were older than 60 years of age (57.8%), male (58.4%), and overweight or obese (83.8%). There was substantial inclusion of minorities and underserved populations, including 46.4% of patients with a race other than White, and 37.2% of patients were of Hispanic ethnicity. Severe or life-threatening COVID-19 was present in 61.8% of patients and 18.9% of patients were mechanically ventilated at time of convalescent plasma infusion. Chronologically and geographically, increases in enrollment in the EAP closely followed confirmed infections across all 50 states. Nearly all national hospital referral regions enrolled patients in the EAP, including both in metropolitan and less populated areas. CONCLUSIONS: The EAP successfully provided widespread access to COVID-19 convalescent plasma in all 50 states, including for underserved racial and ethnic minority populations. The efficient study design of the EAP may serve as an example framework for future efforts when broad access to a treatment is needed in response to a dynamic disease affecting demographic groups and areas historically underrepresented in clinical studies.

8.
N Engl J Med ; 384(11): 1015-1027, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33523609

RESUMEN

BACKGROUND: Convalescent plasma has been widely used to treat coronavirus disease 2019 (Covid-19) under the presumption that such plasma contains potentially therapeutic antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that can be passively transferred to the plasma recipient. Whether convalescent plasma with high antibody levels rather than low antibody levels is associated with a lower risk of death is unknown. METHODS: In a retrospective study based on a U.S. national registry, we determined the anti-SARS-CoV-2 IgG antibody levels in convalescent plasma used to treat hospitalized adults with Covid-19. The primary outcome was death within 30 days after plasma transfusion. Patients who were enrolled through July 4, 2020, and for whom data on anti-SARS-CoV-2 antibody levels in plasma transfusions and on 30-day mortality were available were included in the analysis. RESULTS: Of the 3082 patients included in this analysis, death within 30 days after plasma transfusion occurred in 115 of 515 patients (22.3%) in the high-titer group, 549 of 2006 patients (27.4%) in the medium-titer group, and 166 of 561 patients (29.6%) in the low-titer group. The association of anti-SARS-CoV-2 antibody levels with the risk of death from Covid-19 was moderated by mechanical ventilation status. A lower risk of death within 30 days in the high-titer group than in the low-titer group was observed among patients who had not received mechanical ventilation before transfusion (relative risk, 0.66; 95% confidence interval [CI], 0.48 to 0.91), and no effect on the risk of death was observed among patients who had received mechanical ventilation (relative risk, 1.02; 95% CI, 0.78 to 1.32). CONCLUSIONS: Among patients hospitalized with Covid-19 who were not receiving mechanical ventilation, transfusion of plasma with higher anti-SARS-CoV-2 IgG antibody levels was associated with a lower risk of death than transfusion of plasma with lower antibody levels. (Funded by the Department of Health and Human Services and others; ClinicalTrials.gov number, NCT04338360.).


Asunto(s)
Anticuerpos Antivirales/sangre , COVID-19/terapia , SARS-CoV-2/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/inmunología , COVID-19/mortalidad , Femenino , Hospitalización , Humanos , Inmunización Pasiva , Inmunoglobulina G/sangre , Masculino , Persona de Mediana Edad , Sistema de Registros , Respiración Artificial , Estudios Retrospectivos , Factores de Riesgo , Tiempo de Tratamiento , Estados Unidos/epidemiología , Adulto Joven , Sueroterapia para COVID-19
10.
Transfusion ; 61(1): 72-77, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33029791

RESUMEN

BACKGROUND: The COVID-19 pandemic has placed great strain on blood resources. In an effort to extend platelet (PLT) shelf life and minimize waste, our institution transitioned room temperature to cold-stored PLTs for administration to bleeding patients. STUDY DESIGN AND METHODS: We describe the administrative and technical processes involved in transitioning room temperature PLTs to cold storage in April 2020. Additionally, we describe the clinical utilization of cold-stored PLTs in the first month of this practice change, with a focus on changes in PLT counts after transfusion, hemostasis, and safety outcomes. RESULTS: A total of 61 cold-stored PLT units were transfused to 40 bleeding patients, with a median (interquartile range [IQR]) of 1 (1-2) units per patient. The median age was 68 (59-73) years; 58% male. Median pretransfusion and posttransfusion PLTs counts were 88 (67-109) and 115 (93-145). A total of 95% of transfusions were administered in the operating room: 57% cardiac surgery, 20% vascular surgery, 8% general surgery, and 5% solid organ transplantation. Hemostasis was deemed to be adequate in all cases after transfusion. There were no transfusion reactions. One patient (3%) experienced a fever and infection within 5 days of transfusion, which was unrelated to transfusion. Median (IQR) hospital length of stay was 8.5 (6-17) days. Two patients (5%) died in the hospital of complications not related to transfusion. CONCLUSION: Cold-stored PLT utilization was associated with adequate hemostasis and no overt signal for patient harm. Conversion from room temperature to cold-stored PLTs may be one method of reducing waste in times of scarce blood inventories.


Asunto(s)
Plaquetas , Conservación de la Sangre/métodos , COVID-19/terapia , Transfusión de Plaquetas/métodos , Anciano , Femenino , Hemorragia/terapia , Humanos , Masculino , Persona de Mediana Edad , SARS-CoV-2/inmunología , SARS-CoV-2/patogenicidad , Temperatura
12.
Mayo Clin Proc ; 95(9): 1888-1897, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32861333

RESUMEN

OBJECTIVE: To provide an update on key safety metrics after transfusion of convalescent plasma in hospitalized coronavirus 2019 (COVID-19) patients, having previously demonstrated safety in 5000 hospitalized patients. PATIENTS AND METHODS: From April 3 to June 2, 2020, the US Food and Drug Administration Expanded Access Program for COVID-19 convalescent plasma transfused a convenience sample of 20,000 hospitalized patients with COVID-19 convalescent plasma. RESULTS: The incidence of all serious adverse events was low; these included transfusion reactions (n=78; <1%), thromboembolic or thrombotic events (n=113; <1%), and cardiac events (n=677, ~3%). Notably, the vast majority of the thromboembolic or thrombotic events (n=75) and cardiac events (n=597) were judged to be unrelated to the plasma transfusion per se. The 7-day mortality rate was 13.0% (12.5%, 13.4%), and was higher among more critically ill patients relative to less ill counterparts, including patients admitted to the intensive care unit versus those not admitted (15.6 vs 9.3%), mechanically ventilated versus not ventilated (18.3% vs 9.9%), and with septic shock or multiple organ dysfunction/failure versus those without dysfunction/failure (21.7% vs 11.5%). CONCLUSION: These updated data provide robust evidence that transfusion of convalescent plasma is safe in hospitalized patients with COVID-19, and support the notion that earlier administration of plasma within the clinical course of COVID-19 is more likely to reduce mortality.


Asunto(s)
Infecciones por Coronavirus/terapia , Seguridad del Paciente , Neumonía Viral/terapia , Adolescente , Adulto , Sistemas de Registro de Reacción Adversa a Medicamentos , Anciano , Anciano de 80 o más Años , COVID-19 , Infecciones por Coronavirus/mortalidad , Enfermedad Crítica , Femenino , Hospitalización , Humanos , Inmunización Pasiva/efectos adversos , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/mortalidad , Estados Unidos , Adulto Joven , Sueroterapia para COVID-19
13.
medRxiv ; 2020 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-32817978

RESUMEN

IMPORTANCE: Passive antibody transfer is a longstanding treatment strategy for infectious diseases that involve the respiratory system. In this context, human convalescent plasma has been used to treat coronavirus disease 2019 (COVID-19), but the efficacy remains uncertain. OBJECTIVE: To explore potential signals of efficacy of COVID-19 convalescent plasma. DESIGN: Open-label, Expanded Access Program (EAP) for the treatment of COVID-19 patients with human convalescent plasma. SETTING: Multicenter, including 2,807 acute care facilities in the US and territories. PARTICIPANTS: Adult participants enrolled and transfused under the purview of the US Convalescent Plasma EAP program between April 4 and July 4, 2020 who were hospitalized with (or at risk of) severe or life threatening acute COVID-19 respiratory syndrome. INTERVENTION: Transfusion of at least one unit of human COVID-19 convalescent plasma using standard transfusion guidelines at any time during hospitalization. Convalescent plasma was donated by recently-recovered COVID-19 survivors, and the antibody levels in the units collected were unknown at the time of transfusion. Main Outcomes and Measures: Seven and thirty-day mortality. RESULTS: The 35,322 transfused patients had heterogeneous demographic and clinical characteristics. This cohort included a high proportion of critically-ill patients, with 52.3% in the intensive care unit (ICU) and 27.5% receiving mechanical ventilation at the time of plasma transfusion. The seven-day mortality rate was 8.7% [95% CI 8.3%-9.2%] in patients transfused within 3 days of COVID-19 diagnosis but 11.9% [11.4%-12.2%] in patients transfused 4 or more days after diagnosis (p<0.001). Similar findings were observed in 30-day mortality (21.6% vs. 26.7%, p<0.0001). Importantly, a gradient of mortality was seen in relation to IgG antibody levels in the transfused plasma. For patients who received high IgG plasma (>18.45 S/Co), seven-day mortality was 8.9% (6.8%, 11.7%); for recipients of medium IgG plasma (4.62 to 18.45 S/Co) mortality was 11.6% (10.3%, 13.1%); and for recipients of low IgG plasma (<4.62 S/Co) mortality was 13.7% (11.1%, 16.8%) (p=0.048). This unadjusted dose-response relationship with IgG was also observed in thirty-day mortality (p=0.021). The pooled relative risk of mortality among patients transfused with high antibody level plasma units was 0.65 [0.47-0.92] for 7 days and 0.77 [0.63-0.94] for 30 days compared to low antibody level plasma units. CONCLUSIONS AND RELEVANCE: The relationships between reduced mortality and both earlier time to transfusion and higher antibody levels provide signatures of efficacy for convalescent plasma in the treatment of hospitalized COVID-19 patients. This information may be informative for the treatment of COVID-19 and design of randomized clinical trials involving convalescent plasma. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04338360.

14.
J Clin Invest ; 130(9): 4791-4797, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32525844

RESUMEN

BACKGROUNDConvalescent plasma is the only antibody-based therapy currently available for patients with coronavirus disease 2019 (COVID-19). It has robust historical precedence and sound biological plausibility. Although promising, convalescent plasma has not yet been shown to be safe as a treatment for COVID-19.METHODSThus, we analyzed key safety metrics after transfusion of ABO-compatible human COVID-19 convalescent plasma in 5000 hospitalized adults with severe or life-threatening COVID-19, with 66% in the intensive care unit, as part of the US FDA expanded access program for COVID-19 convalescent plasma.RESULTSThe incidence of all serious adverse events (SAEs), including mortality rate (0.3%), in the first 4 hours after transfusion was <1%. Of the 36 reported SAEs, there were 25 reported incidences of related SAEs, including mortality (n = 4), transfusion-associated circulatory overload (n = 7), transfusion-related acute lung injury (n = 11), and severe allergic transfusion reactions (n = 3). However, only 2 of 36 SAEs were judged as definitely related to the convalescent plasma transfusion by the treating physician. The 7-day mortality rate was 14.9%.CONCLUSIONGiven the deadly nature of COVID-19 and the large population of critically ill patients included in these analyses, the mortality rate does not appear excessive. These early indicators suggest that transfusion of convalescent plasma is safe in hospitalized patients with COVID-19.TRIAL REGISTRATIONClinicalTrials.gov NCT04338360.FUNDINGMayo Clinic, Biomedical Advanced Research and Development Authority (75A50120C00096), National Center for Advancing Translational Sciences (UL1TR002377), National Heart, Lung, and Blood Institute (5R35HL139854 and R01 HL059842), National Institute of Diabetes and Digestive and Kidney Diseases (5T32DK07352), Natural Sciences and Engineering Research Council of Canada (PDF-532926-2019), National Institute of Allergy and Infectious Disease (R21 AI145356, R21 AI152318, and AI152078), Schwab Charitable Fund, United Health Group, National Basketball Association, Millennium Pharmaceuticals, and Octapharma USA Inc.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/terapia , Neumonía Viral/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , COVID-19 , Ensayos de Uso Compasivo , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/mortalidad , Femenino , Humanos , Inmunización Pasiva/efectos adversos , Inmunización Pasiva/mortalidad , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , SARS-CoV-2 , Seguridad , Reacción a la Transfusión/epidemiología , Reacción a la Transfusión/etiología , Lesión Pulmonar Aguda Postransfusional/epidemiología , Lesión Pulmonar Aguda Postransfusional/etiología , Estados Unidos/epidemiología , United States Food and Drug Administration , Adulto Joven , Sueroterapia para COVID-19
15.
BMJ Open ; 7(8): e016398, 2017 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-28821525

RESUMEN

INTRODUCTION: The transfusion-related respiratory complications, transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO), are leading causes of transfusion-related morbidity and mortality. At present, there are no effective preventive strategies with red blood cell (RBC) transfusion. Although mechanisms remain incompletely defined, soluble biological response modifiers (BRMs) within the RBC storage solution may play an important role. Point-of-care (POC) washing of allogeneic RBCs may remove these BRMs, thereby mitigating their impact on post-transfusion respiratory complications. METHODS AND ANALYSIS: This is a multicenter randomised clinical trial of standard allogeneic versus washed allogeneic RBC transfusion for adult patients undergoing cardiac surgery testing the hypothesis that POC RBC washing is feasible, safe, and efficacious and will reduce recipient immune and physiologic responses associated with transfusion-related respiratory complications. Relevant clinical outcomes will also be assessed. This investigation will enrol 170 patients at two hospitals in the USA. Simon's two-stage design will be used to assess the feasibility of POC RBC washing. The primary safety outcomes will be assessed using Wilcoxon Rank-Sum tests for continuous variables and Pearson chi-square test for categorical variables. Standard mixed modelling practices will be employed to test for changes in biomarkers of lung injury following transfusion. Linear regression will assess relationships between randomised group and post-transfusion physiologic measures. ETHICS AND DISSEMINATION: Safety oversight will be conducted under the direction of an independent Data and Safety Monitoring Board (DSMB). Approval of the protocol was obtained by the DSMB as well as the institutional review boards at each institution prior to enrolling the first study participant. This study aims to provide important information regarding the feasibility of POC washing of allogeneic RBCs and its potential impact on ameliorating post-transfusion respiratory complications. Additionally, it will inform the feasibility and scientific merit of pursuing a more definitive phase II/III clinical trial. REGISTRATION: ClinicalTrials.gov registration number is NCT02094118 (Pre-results).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Transfusión de Eritrocitos/métodos , Eritrocitos , Atención Perioperativa , Sistemas de Atención de Punto , Edema Pulmonar/prevención & control , Insuficiencia Respiratoria/prevención & control , Adolescente , Adulto , Transfusión de Eritrocitos/efectos adversos , Femenino , Humanos , Factores Inmunológicos/efectos adversos , Pulmón , Masculino , Edema Pulmonar/etiología , Proyectos de Investigación , Insuficiencia Respiratoria/etiología
16.
Adv Neonatal Care ; 16(1): E3-9, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26734813

RESUMEN

BACKGROUND: Extremely low birth-weight (ELBW) infants frequently receive packed red blood cell (PRBC) transfusions. Recent studies have shown that more restrictive PRBC transfusion guidelines limit donor exposure and reduce transfusion-related costs without any increase in adverse clinical outcomes. PURPOSE: We developed and implemented an evidence-based PRBC transfusion guideline for ELBW infants treated in our unit and then measured provider adherence to this guideline. METHODS/SEARCH STRATEGY: We performed a retrospective review of all PRBC transfusions given to ELBW infants in 2012 (preguideline) and the first half of 2014 (postguideline). We identified the indication for each transfusion by reviewing physiological/laboratory data and the daily clinical note. We then determine whether each transfusion met criteria according to our new evidence-based guideline. FINDINGS/RESULTS: When extrapolating the newly developed protocol to 2012 data, less than 15% of transfusions among ELBW infants would have met the current evidence-based standard. Conversely, during the first 6 months of 2014, 61% of transfusions were administered in adherence to the guideline (P < 001). Using current cost estimates, this represents a projected cost savings of $31,000 in that 6-month period. IMPLICATIONS FOR PRACTICE: A multidisciplinary approach to improving PRBC transfusion practices results in potentially safer, more cost-effective care for ELBW infants. IMPLICATIONS FOR RESEARCH: Given the frequency, potential harms, and costs associated with PRBC transfusions in ELBW infants, it seems both feasible and important to pursue prospective clinical trials comparing permissive and restrictive approaches to transfusion in this vulnerable population.


Asunto(s)
Anemia Neonatal/terapia , Transfusión de Sangre Autóloga/normas , Transfusión de Eritrocitos/efectos adversos , Transfusión de Eritrocitos/economía , Práctica Clínica Basada en la Evidencia/normas , Enfermería Neonatal/normas , Guías de Práctica Clínica como Asunto , Anemia Neonatal/economía , Transfusión de Sangre Autóloga/economía , Práctica Clínica Basada en la Evidencia/economía , Humanos , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recien Nacido Extremadamente Prematuro , Recién Nacido , Enfermería Neonatal/economía , Estudios Prospectivos , Estudios Retrospectivos
17.
J Appl Physiol (1985) ; 117(2): 131-41, 2014 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-24876357

RESUMEN

The purpose of this study was to compare hemodynamic and blood analyte responses to reduced central venous pressure (CVP) and pulse pressure (PP) elicited during graded lower body negative pressure (LBNP) to those observed during graded blood loss (BL) in conscious humans. We hypothesized that the stimulus-response relationships of CVP and PP to hemodynamic responses during LBNP would mimic those observed during BL. We assessed CVP, PP, heart rate, mean arterial pressure (MAP), and other hemodynamic markers in 12 men during LBNP and BL. Blood samples were obtained for analysis of catecholamines, hematocrit, hemoglobin, arginine vasopressin, and blood gases. LBNP consisted of 5-min stages at 0, 15, 30, and 45 mmHg of suction. BL consisted of 5 min at baseline and following three stages of 333 ml of hemorrhage (1,000 ml total). Individual r(2) values and linear regression slopes were calculated to determine whether the stimulus (CVP and PP)-hemodynamic response trajectories were similar between protocols. The CVP-MAP trajectory was the only CVP-response slope that was statistically different during LBNP compared with BL (0.93 ± 0.27 vs. 0.13 ± 0.26; P = 0.037). The PP-heart rate trajectory was the only PP-response slope that was statistically different during LBNP compared with BL (-1.85 ± 0.45 vs. -0.46 ± 0.27; P = 0.024). Norepinephrine, hematocrit, and hemoglobin were all lower at termination in the BL protocol compared with LBNP (P < 0.05). Consistent with our hypothesis, LBNP mimics the hemodynamic stimulus-response trajectories observed during BL across a significant range of CVP in humans.


Asunto(s)
Presión Venosa Central/fisiología , Hemodinámica/fisiología , Hemorragia/fisiopatología , Adulto , Arginina Vasopresina/metabolismo , Presión Arterial/fisiología , Análisis de los Gases de la Sangre/métodos , Catecolaminas/metabolismo , Frecuencia Cardíaca/fisiología , Hematócrito/métodos , Hemoglobinas/metabolismo , Hemorragia/metabolismo , Humanos , Presión Negativa de la Región Corporal Inferior/métodos , Masculino , Norepinefrina/metabolismo
18.
Transfusion ; 54(9): 2175-81, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24660833

RESUMEN

BACKGROUND: Allogeneic blood transfusion induces immunosuppression, and concern has been raised that it may increase propensity for cancer recurrence; however, these effects have not been confirmed. We examined the association of perioperative transfusion of allogeneic blood long-term oncologic outcomes in patients with prostate cancer who underwent prostatectomy. STUDY DESIGN AND METHODS: We reviewed medical records of patients who underwent radical prostatectomy between 1991 and 2005 and received allogeneic nonleukoreduced blood. Each transfused patient was matched to two controls who did not receive blood: matching included age, surgical year, prostate-specific antigen level, pathologic tumor stages, pathologic Gleason scores, and anesthetic type. Primary outcome was systemic tumor progression, with secondary outcomes of prostate cancer death and all-cause mortality. Stratified proportional hazards regression analysis was used to assess differences in outcomes between the transfused and nontransfused group. RESULTS: A total of 379 prostatectomy patients who were transfused and 758 nontransfused controls were followed for 9.4 and 10.2 years (median), respectively. In a multivariable analysis that took into account the matched study design and adjusted for positive surgical margins and adjuvant therapies, the use of allogeneic blood was not associated with systemic tumor progression (hazard ratio [HR], 0.88; 95% confidence interval [CI], 0.39-1.99; p = 0.76), prostate cancer-specific death (HR, 1.69; 95% CI, 0.44 to 6.48; p = 0.44), or all-cause death (HR, 1.20; 95% CI, 0.87 to 1.67; p = 0.27). CONCLUSIONS: When adjusted for clinicopathologic and procedural variables transfusion of allogeneic blood was not associated with systemic tumor progression and survival outcomes.


Asunto(s)
Prostatectomía/métodos , Neoplasias de la Próstata/cirugía , Reacción a la Transfusión , Anciano , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Neoplasias de la Próstata/patología , Estudios Retrospectivos
19.
Blood Transfus ; 10(4): 453-61, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22507860

RESUMEN

BACKGROUND: We used sensitive spectroscopic techniques to measure changes in Band 3 oligomeric state during storage of packed red blood cells (RBC); these changes were compared to metabolic changes, RBC morphology, cholesterol and membrane protein loss, phospholipid reorganisation of the RBC membrane, and peroxidation of membrane lipid. The aim of the study was to temporally sequence major biochemical events occurring during cold storage, in order to determine which changes may underlie the structural defects in stored RBC. MATERIALS AND METHODS: Fifteen RBC units were collected from normal volunteers and stored under standard blood bank conditions; both metabolic changes and lipid parameters were measured by multiple novel assays including a new mass spectrometric measurement of isoprostane (lipid peroxidation) and flow cytometric assessment of CD47 expression. Band 3 oligomeric state was assessed by time-resolved phosphorescence anisotropy, and RBC morphology by microscopy of glutaraldehyde-fixed RBC. RESULTS: Extracellular pH decreased and extracellular potassium increased rapidly during cold storage. Band 3 on the RBC membrane aggregated into large oligomers early in the storage period and coincident with changes in RBC morphology. Membrane lipid changes, including loss of unesterified cholesterol, lipid peroxidation and expression of CD47, also changed early during the storage period. In contrast loss of acetylcholinesterase activity and haemolysis of RBC occurred late during storage. DISCUSSION: Our results demonstrate that changes in the macromolecular organisation of membrane proteins on the RBC occur early in storage and suggest that lipid peroxidation and/or oxidative damage to the membrane are responsible for irreversible morphological changes and loss of function during red cell storage.


Asunto(s)
Proteína 1 de Intercambio de Anión de Eritrocito/metabolismo , Bancos de Sangre , Conservación de la Sangre , Antígeno CD47/biosíntesis , Membrana Eritrocítica/metabolismo , Peroxidación de Lípido , Femenino , Regulación de la Expresión Génica , Humanos , Concentración de Iones de Hidrógeno , Masculino
20.
Am J Respir Crit Care Med ; 185(8): 842-50, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22281833

RESUMEN

RATIONALE: Transfusion-related pulmonary complications are leading causes of morbidity and mortality attributed to transfusion. Observational studies suggest an important role for red blood cell (RBC) storage duration in these adverse outcomes. OBJECTIVES: To evaluate the impact of RBC storage duration on short-term pulmonary function as well as immunologic and coagulation status in mechanically ventilated patients receiving RBC transfusion. METHODS: This is a double-blind, randomized, clinical trial comparing fresh (≤5 d of storage) versus standard issue single-unit RBC transfusion in adult intubated and mechanically ventilated patients. The primary outcome is the change in pulmonary gas exchange as assessed by the partial pressure of arterial oxygen to fraction of inspired oxygen concentration ratio (ΔPa(O(2))/Fi(O(2))). Secondary outcomes include changes in immune and coagulation status. MEASUREMENTS AND MAIN RESULTS: Fifty patients were randomized to receive fresh RBCs and an additional 50 patients to standard issue RBCs. Median storage age was 4.0 days (interquartile range, 3.0-5.0) and 26.5 days (interquartile range, 21.0-36.0) in the fresh RBC group and standard issue RBC group, respectively. No differences were noted in the primary outcome of ΔPa(O(2))/Fi(O(2)) (difference between the mean ΔPa(O(2))/Fi(O(2)) in the standard issue RBC group vs. the fresh RBC group, -11.5; 95% confidence interval, -35.3 to 12.3; P = 0.22). Similarly, no significant differences were noted in markers of immunologic or coagulation status. CONCLUSIONS: In this randomized clinical trial, no differences were noted in early measures of pulmonary function or in immunologic or coagulation status when comparing fresh versus standard issue single-unit RBC transfusion. Clinical trial registered with ClinicalTrials.gov (NCT00751322).


Asunto(s)
Trastornos de la Coagulación Sanguínea/etiología , Conservación de la Sangre/efectos adversos , Seguridad de la Sangre , Transfusión de Eritrocitos/efectos adversos , Enfermedades Pulmonares/etiología , Centros Médicos Académicos , Anciano , Biomarcadores/sangre , Bancos de Sangre , Trastornos de la Coagulación Sanguínea/epidemiología , Conservación de la Sangre/métodos , Enfermedad Crítica/mortalidad , Enfermedad Crítica/terapia , Método Doble Ciego , Transfusión de Eritrocitos/métodos , Femenino , Humanos , Unidades de Cuidados Intensivos , Intubación Intratraqueal , Enfermedades Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Intercambio Gaseoso Pulmonar , Valores de Referencia , Respiración Artificial , Medición de Riesgo , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...