Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
1.
BJR Open ; 6(1): tzae006, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38737623

RESUMEN

Objectives: We validated an auto-contouring algorithm for heart substructures in lung cancer patients, aiming to establish its accuracy and reliability for radiotherapy (RT) planning. We focus on contouring an amalgamated set of subregions in the base of the heart considered to be a new organ at risk, the cardiac avoidance area (CAA), to enable maximum dose limit implementation in lung RT planning. Methods: The study validates a deep-learning model specifically adapted for auto-contouring the CAA (which includes the right atrium, aortic valve root, and proximal segments of the left and right coronary arteries). Geometric, dosimetric, quantitative, and qualitative validation measures are reported. Comparison with manual contours, including assessment of interobserver variability, and robustness testing over 198 cases are also conducted. Results: Geometric validation shows that auto-contouring performance lies within the expected range of manual observer variability despite being slightly poorer than the average of manual observers (mean surface distance for CAA of 1.6 vs 1.2 mm, dice similarity coefficient of 0.86 vs 0.88). Dosimetric validation demonstrates consistency between plans optimized using auto-contours and manual contours. Robustness testing confirms acceptable contours in all cases, with 80% rated as "Good" and the remaining 20% as "Useful." Conclusions: The auto-contouring algorithm for heart substructures in lung cancer patients demonstrates acceptable and comparable performance to human observers. Advances in knowledge: Accurate and reliable auto-contouring results for the CAA facilitate the implementation of a maximum dose limit to this region in lung RT planning, which has now been introduced in the routine setting at our institution.

2.
Radiother Oncol ; 193: 110113, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38301958

RESUMEN

BACKGROUND AND PURPOSE: Radiation induced cardiotoxicity (RICT) is as an important sequela of radiotherapy to the thorax for patients. In this study, we aim to investigate the dose and fractionation response of RICT. We propose global longitudinal strain (GLS) as an early indicator of RICT and investigate myocardial deformation following irradiation. METHODS: RICT was investigated in female C57BL/6J mice in which the base of the heart was irradiated under image-guidance using a small animal radiation research platform (SARRP). Mice were randomly assigned to a treatment group: single-fraction dose of 16 Gy or 20 Gy, 3 consecutive fractions of 8.66 Gy, or sham irradiation; biological effective doses (BED) used were 101.3 Gy, 153.3 Gy and 101.3 Gy respectively. Longitudinal transthoracic echocardiography (TTE) was performed from baseline up to 50 weeks post-irradiation to detect structural and functional effects. RESULTS: Irradiation of the heart base leads to BED-dependent changes in systolic and diastolic function 50 weeks post-irradiation. GLS showed significant decreases in a BED-dependent manner for all irradiated animals, as early as 10 weeks after irradiation. Early changes in GLS indicate late changes in cardiac function. BED-independent increases were observed in the left ventricle (LV) mass and volume and myocardial fibrosis. CONCLUSIONS: Functional features of RICT displayed a BED dependence in this study. GLS showed an early change at 10 weeks post-irradiation. Cardiac remodelling was observed as increases in mass and volume of the LV, further supporting our hypothesis that dose to the base of the heart drives the global heart toxicity.


Asunto(s)
Corazón , Miocardio , Humanos , Femenino , Animales , Ratones , Ratones Endogámicos C57BL , Corazón/efectos de la radiación , Ecocardiografía , Cardiotoxicidad/etiología
3.
Br J Radiol ; 97(1156): 757-762, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38407369

RESUMEN

OBJECTIVES: Metallic implants cause artefacts and distortion on MRI. To ensure accurate dose delivery and plan adaptation on an MR Linac, there is a need to evaluate distortion caused. METHODS: Participants were imaged on an MR Linac (Elekta Unity, Elekta AB Stockholm). Three sequences were evaluated. Two vendor supplied (T2W TSE 3D), and one T2W TSE 3D optimized to reduce metal artefact distortions. Images were rigidly registered to CT images by a single observer, using bony anatomy. Three coronal and three axial images were selected, and six paired, adjacent, bony landmarks were identified on each slice. Images bisecting treatment isocentre were included. Difference between landmark coordinates was taken to be measure of distortion. RESULTS: Five observers participated. Thirty six pairs of bony landmarks were identified. Median difference in position of landmarks was ≤3 mm (range 0.3-4.4 mm). One-way analysis of variance (ANOVA) between observer means showed no significant variation between sequences or patients (P = 1.26 in plane, P = 0.11 through plane). Interobserver intra class correlation (ICC) was 0.70 in-plane and 0.78 through-plane. Intra-observer ICC for three observers was 0.76, 0.81, 0.83, showing moderate to good reliability on this small cohort. CONCLUSIONS: This in-vivo feasibility study suggests distortion due to metallic hip prosthesis is not an obstacle for pelvic radiotherapy on an MR Linac. Research on the impact on plan quality is warranted. ADVANCES IN KNOWLEDGE: This work supports feasibility of treating patients with metallic hip prosthesis on an MR Linac.


Asunto(s)
Prótesis de Cadera , Neoplasias de la Próstata , Masculino , Humanos , Prótesis de Cadera/efectos adversos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Aceleradores de Partículas
4.
Radiother Oncol ; 190: 109963, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38406888

RESUMEN

BACKGROUND: Implementation of daily cone-beam CT (CBCT) into clinical practice in paediatric image-guided radiotherapy (IGRT) lags behind compared to adults. Surveys report wide variation in practice for paediatric IGRT and technical information remains unreported. In this study we report on technical settings from applied paediatric CBCT protocols and review the literature for paediatric CBCT protocols. METHODS: From September to October 2022, a survey was conducted among 246 SIOPE-affiliated centres across 35 countries. The survey consisted of 3 parts: 1) baseline information; technical CBCT exposure settings and patient set-up procedure for 2) brain/head, and 3) abdomen. Descriptive statistics was used to summarise current practice. The literature was reviewed systematically with two reviewers obtaining consensus RESULTS: The literature search revealed 22 papers concerning paediatric CBCT protocols. Seven papers focused on dose-optimisation. Responses from 50/246 centres in 25/35 countries were collected: 44/50 treated with photons and 10/50 with protons. In total, 48 brain/head and 53 abdominal protocols were reported. 42/50 centres used kV-CBCT for brain/head and 35/50 for abdomen; daily CBCT was used for brain/head = 28/48 (58%) and abdomen = 33/53 62%. Greater consistency was seen in brain/head protocols (dose range 0.32 - 67.7 mGy) compared to abdominal (dose range 0.27 - 119.7 mGy). CONCLUSION: Although daily CBCT is now widely used in paediatric IGRT, our survey demonstrates a wide range of technical settings, suggesting an unmet need to optimise paediatric IGRT protocols. This is in accordance with the literature. However, there are only few paediatric optimisation studies suggesting that dose reduction is possible while maintaining image quality.


Asunto(s)
Radioterapia Guiada por Imagen , Tomografía Computarizada de Haz Cónico Espiral , Adulto , Humanos , Niño , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Abdomen , Tomografía Computarizada de Haz Cónico/métodos , Europa (Continente) , Fantasmas de Imagen , Dosificación Radioterapéutica , Literatura de Revisión como Asunto
5.
Front Cardiovasc Med ; 10: 1267800, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37799779

RESUMEN

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

6.
Breast ; 72: 103578, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37713940

RESUMEN

BACKGROUND: Normal tissue complication probability (NTCP) models can be useful to estimate the risk of fibrosis after breast-conserving surgery (BCS) and radiotherapy (RT) to the breast. However, they are subject to uncertainties. We present the impact of contouring variation on the prediction of fibrosis. MATERIALS AND METHODS: 280 breast cancer patients treated BCS-RT were included. Nine Clinical Target Volume (CTV) contours were created for each patient: i) CTV_crop (reference), cropped 5 mm from the skin and ii) CTV_skin, uncropped and including the skin, iii) segmenting the 95% isodose (Iso95%) and iv) 3 different auto-contouring atlases generating uncropped and cropped contours (Atlas_skin/Atlas_crop). To illustrate the impact of contour variation on NTCP estimates, we applied two equations predicting fibrosis grade ≥ 2 at 5 years, based on Lyman-Kutcher-Burman (LKB) and Relative Seriality (RS) models, respectively, to each contour. Differences were evaluated using repeated-measures ANOVA. For completeness, the association between observed fibrosis events and NTCP estimates was also evaluated using logistic regression. RESULTS: There were minimal differences between contours when the same contouring approach was followed (cropped and uncropped). CTV_skin and Atlas_skin contours had lower NTCP estimates (-3.92%, IQR 4.00, p < 0.05) compared to CTV_crop. No significant difference was observed for Atlas_crop and Iso95% contours compared to CTV_crop. For the whole cohort, NTCP estimates varied between 5.3% and 49.5% (LKB) or 2.2% and 49.6% (RS) depending on the choice of contours. NTCP estimates for individual patients varied by up to a factor of 4. Estimates from "skin" contours showed higher agreement with observed events. CONCLUSION: Contour variations can lead to significantly different NTCP estimates for breast fibrosis, highlighting the importance of standardising breast contours before developing and/or applying NTCP models.


Asunto(s)
Neoplasias de la Mama , Enfermedad Fibroquística de la Mama , Femenino , Humanos , Dosificación Radioterapéutica , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Mama/diagnóstico por imagen , Planificación de la Radioterapia Asistida por Computador , Probabilidad , Fibrosis
7.
Front Oncol ; 13: 1200676, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37397380

RESUMEN

Background: One in three high-risk prostate cancer patients treated with radiotherapy recur. Detection of lymph node metastasis and microscopic disease spread using conventional imaging is poor, and many patients are under-treated due to suboptimal seminal vesicle or lymph node irradiation. We use Image Based Data Mining (IBDM) to investigate association between dose distributions, and prognostic variables and biochemical recurrence (BCR) in prostate cancer patients treated with radiotherapy. We further test whether including dose information in risk-stratification models improves performance. Method: Planning CTs, dose distributions and clinical information were collected for 612 high-risk prostate cancer patients treated with conformal hypo-fractionated radiotherapy, intensity modulated radiotherapy (IMRT), or IMRT plus a single fraction high dose rate (HDR) brachytherapy boost. Dose distributions (including HDR boost) of all studied patients were mapped to a reference anatomy using the prostate delineations. Regions where dose distributions significantly differed between patients that did and did-not experience BCR were assessed voxel-wise using 1) a binary endpoint of BCR at four-years (dose only) and 2) Cox-IBDM (dose and prognostic variables). Regions where dose was associated with outcome were identified. Cox proportional-hazard models with and without region dose information were produced and the Akaike Information Criterion (AIC) was used to assess model performance. Results: No significant regions were observed for patients treated with hypo-fractionated radiotherapy or IMRT. Regions outside the target where higher dose was associated with lower BCR were observed for patients treated with brachytherapy boost. Cox-IBDM revealed that dose response was influenced by age and T-stage. A region at the seminal vesicle tips was identified in binary- and Cox-IBDM. Including the mean dose in this region in a risk-stratification model (hazard ratio=0.84, p=0.005) significantly reduced AIC values (p=0.019), indicating superior performance, compared with prognostic variables only. The region dose was lower in the brachytherapy boost patients compared with the external beam cohorts supporting the occurrence of marginal misses. Conclusion: Association was identified between BCR and dose outside of the target region in high-risk prostate cancer patients treated with IMRT plus brachytherapy boost. We show, for the first-time, that the importance of irradiating this region is linked to prognostic variables.

8.
Front Oncol ; 13: 1156389, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37503315

RESUMEN

Purpose: For patients receiving lung stereotactic ablative radiotherapy (SABR), evidence suggests that high peritumor density predicts an increased risk of microscopic disease (MDE) and local-regional failure, but only if there is low or heterogenous incidental dose surrounding the tumor (GTV). A data-mining method (Cox-per-radius) has been developed to investigate this dose-density interaction. We apply the method to predict local relapse (LR) and regional failure (RF) in patients with non-small cell lung cancer. Methods: 199 patients treated in a routine setting were collated from a single institution for training, and 76 patients from an external institution for validation. Three density metrics (mean, 90th percentile, standard deviation (SD)) were studied in 1mm annuli between 0.5cm inside and 2cm outside the GTV boundary. Dose SD and fraction of volume receiving less than 30Gy were studied in annuli 0.5-2cm outside the GTV to describe incidental MDE dosage. Heat-maps were created that correlate with changes in LR and RF rates due to the interaction between dose heterogeneity and density at each distance combination. Regions of significant improvement were studied in Cox proportional hazards models, and explored with and without re-fitting in external data. Correlations between the dose component of the interaction and common dose metrics were reported. Results: Local relapse occurred at a rate of 6.5% in the training cohort, and 18% in the validation cohort, which included larger and more centrally located tumors. High peritumor density in combination with high dose variability (0.5 - 1.6cm) predicts LR. No interactions predicted RF. The LR interaction improved the predictive ability compared to using clinical variables alone (optimism-adjusted C-index; 0.82 vs 0.76). Re-fitting model coefficients in external data confirmed the importance of this interaction (C-index; 0.86 vs 0.76). Dose variability in the 0.5-1.6 cm annular region strongly correlates with heterogeneity inside the target volume (SD; ρ = 0.53 training, ρ = 0.65 validation). Conclusion: In these real-world cohorts, the combination of relatively high peritumor density and high dose variability predicts increase in LR, but not RF, following lung SABR. This external validation justifies potential use of the model to increase low-dose CTV margins for high-risk patients.

9.
Int J Radiat Oncol Biol Phys ; 117(4): 903-913, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37331569

RESUMEN

PURPOSE: Dysphagia is a common toxicity after head and neck (HN) radiation therapy that negatively affects quality of life. We explored the relationship between radiation therapy dose to normal HN structures and dysphagia 1 year after treatment using image-based datamining (IBDM), a voxel-based analysis technique. METHODS AND MATERIALS: We used data from 104 patients with oropharyngeal cancer treated with definitive (chemo)radiation therapy. Swallow function was assessed pretreatment and 1 year posttreatment using 3 validated measures: MD Anderson Dysphagia Inventory (MDADI), performance status scale for normalcy of diet (PSS-HN), and water swallowing test (WST). For IBDM, we spatially normalized all patients' planning dose matrices to 3 reference anatomies. Regions where the dose was associated with dysphagia measures at 1 year were found by performing voxel-wise statistics and permutation testing. Clinical factors, treatment variables, and pretreatment measures were used in multivariable analysis to predict each dysphagia measure at 1 year. Clinical baseline models were found using backward stepwise selection. Improvement in model discrimination after adding the mean dose to the identified region was quantified using the Akaike information criterion. We also compared the prediction performance of the identified region with a well-established association: mean doses to the pharyngeal constrictor muscles. RESULTS: IBDM revealed highly significant associations between dose to distinct regions and the 3 outcomes. These regions overlapped around the inferior section of the brain stem. All clinical models were significantly improved by including mean dose to the overlap region (P ≤ .006). Including pharyngeal dosimetry significantly improved WST (P = .04) but not PSS-HN or MDADI (P ≥ .06). CONCLUSIONS: In this hypothesis-generating study, we found that mean dose to the inferior section of the brain stem is strongly associated with dysphagia 1 year posttreatment. The identified region includes the swallowing centers in the medulla oblongata, providing a possible mechanistic explanation. Further work including validation in an independent cohort is required.


Asunto(s)
Trastornos de Deglución , Neoplasias de Cabeza y Cuello , Neoplasias Orofaríngeas , Humanos , Trastornos de Deglución/etiología , Calidad de Vida , Neoplasias Orofaríngeas/diagnóstico por imagen , Neoplasias Orofaríngeas/radioterapia , Deglución/fisiología , Tronco Encefálico/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia
10.
Radiother Oncol ; 186: 109764, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37385375

RESUMEN

BACKGROUND AND PURPOSE: Low muscle mass is an imaging biomarker of patient frailty that has been associated with increased toxicity and decreased survival in a number of cancers. Patients with unresectable oesophageal cancer receive chemoradiotherapy as standard of care. Muscle mass is not yet an established prognostic marker in this population. Muscle mass is usually assessed by segmenting skeletal muscle at the L3 vertebral level. But radiotherapy planning scans for oesophageal cancers do not always image this level, which has limited previous studies of body composition. Skeletal muscle is known to regulate immune function, but the association of muscle mass with lymphopenia in cancer patients has not been shown. MATERIALS AND METHODS: We retrospectively analyse 135 oesophageal cancer patients who received chemoradiotherapy and investigate the prognostic value of skeletal muscle area assessed at T12. We also examine the association between muscle mass and radiation-induced lymphopenia. RESULTS: We find that low muscle mass is associated with poorer overall survival (hazard ratio [95% confidence interval]: 0.72 [0.53-0.97]). However, this effect interacts with body mass index (BMI) such that the prognostic value of low muscle mass is removed by high BMI. In our study, patients with low muscle mass were more prone to radiation-induced lymphopenia (75% vs. 50% in patients with high muscle mass). A significant decrease in circulating lymphocytes was associated with poorer overall survival (hazard ratio [95% confidence interval]: 0.68 [0.47-0.99]). CONCLUSION: Our study shows that assessing muscle mass at T12 is feasible and provides prognostic information. Low muscle mass at T12 is associated with poorer overall survival and increased risk of radiation-induced lymphopenia. Muscle mass provides additional information over performance status and BMI. Low BMI patients are most affected by low muscle mass, highlighting the importance of close nutritional support in this population.


Asunto(s)
Neoplasias Esofágicas , Linfopenia , Sarcopenia , Humanos , Pronóstico , Sarcopenia/etiología , Sarcopenia/patología , Estudios Retrospectivos , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/patología , Neoplasias Esofágicas/terapia , Quimioradioterapia/efectos adversos , Linfopenia/etiología , Linfopenia/patología
11.
12.
Phys Med ; 109: 102579, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37068428

RESUMEN

PURPOSE: In addition to patient set-up uncertainties, anatomical deformations, e.g., weight loss, lead to time-dependent differences between the planned and delivered dose in a radiotherapy course that currently cannot easily be predicted. The aim of this study was to create time-varying prediction models to describe both the average and residual anatomical deformations. METHODS: Weekly population-based principal component analysis models were generated from on-treatment cone-beam CT scans (CBCTs) of 30 head and neck cancer patients, with additional data of 35 patients used as a validation cohort. We simulated treatment courses accounting for a) anatomical deformations, b) set-up uncertainties and c) a combination of both. The dosimetric effects of the simulated deformations were compared to a direct dose accumulation based on deformable registration of the CBCT data. RESULTS: Set-up uncertainties were seen to have a larger effect on the organ at risk (OAR) doses than anatomical deformations for all OARs except the larynx and the primary CTV. Distributions from simulation results were in good agreement with those of the accumulated dose. CONCLUSIONS: We present a novel method of modelling time-varying organ deformations in head and neck cancer. The effect on the OAR doses from these deformations are smaller than the effect of set-up uncertainties for most OARs. These models can, for instance, be used to predict which patients could benefit from adaptive radiotherapy, prior to commencing treatment.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Dosificación Radioterapéutica , Tomografía Computarizada de Haz Cónico/métodos
13.
Radiother Oncol ; 183: 109592, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36870608

RESUMEN

BACKGROUND AND PURPOSE: Tumour hypoxia is prognostic in head and neck cancer (HNC), associated with poor loco-regional control, poor survival and treatment resistance. The advent of hybrid MRI - radiotherapy linear accelerator or 'MR Linac' systems - could permit imaging for treatment adaptation based on hypoxic status. We sought to develop oxygen-enhanced MRI (OE-MRI) in HNC and translate the technique onto an MR Linac system. MATERIALS AND METHODS: MRI sequences were developed in phantoms and 15 healthy participants. Next, 14 HNC patients (with 21 primary or local nodal tumours) were evaluated. Baseline tissue longitudinal relaxation time (T1) was measured alongside the change in 1/T1 (termed ΔR1) between air and oxygen gas breathing phases. We compared results from 1.5 T diagnostic MR and MR Linac systems. RESULTS: Baseline T1 had excellent repeatability in phantoms, healthy participants and patients on both systems. Cohort nasal concha oxygen-induced ΔR1 significantly increased (p < 0.0001) in healthy participants demonstrating OE-MRI feasibility. ΔR1 repeatability coefficients (RC) were 0.023-0.040 s-1 across both MR systems. The tumour ΔR1 RC was 0.013 s-1 and the within-subject coefficient of variation (wCV) was 25% on the diagnostic MR. Tumour ΔR1 RC was 0.020 s-1 and wCV was 33% on the MR Linac. ΔR1 magnitude and time-course trends were similar on both systems. CONCLUSION: We demonstrate first-in-human translation of volumetric, dynamic OE-MRI onto an MR Linac system, yielding repeatable hypoxia biomarkers. Data were equivalent on the diagnostic MR and MR Linac systems. OE-MRI has potential to guide future clinical trials of biology guided adaptive radiotherapy.


Asunto(s)
Neoplasias de Cabeza y Cuello , Oxígeno , Humanos , Imagen por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Hipoxia , Pronóstico , Aceleradores de Partículas
14.
Phys Med Biol ; 68(8)2023 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-36893469

RESUMEN

Objective.Automatic segmentation of organs-at-risk in radiotherapy planning computed tomography (CT) scans using convolutional neural networks (CNNs) is an active research area. Very large datasets are usually required to train such CNN models. In radiotherapy, large, high-quality datasets are scarce and combining data from several sources can reduce the consistency of training segmentations. It is therefore important to understand the impact of training data quality on the performance of auto-segmentation models for radiotherapy.Approach.In this study, we took an existing 3D CNN architecture for head and neck CT auto-segmentation and compare the performance of models trained with a small, well-curated dataset (n= 34) and then a far larger dataset (n= 185) containing less consistent training segmentations. We performed 5-fold cross-validations in each dataset and tested segmentation performance using the 95th percentile Hausdorff distance and mean distance-to-agreement metrics. Finally, we validated the generalisability of our models with an external cohort of patient data (n= 12) with five expert annotators.Main results.The models trained with a large dataset were greatly outperformed by models (of identical architecture) trained with a smaller, but higher consistency set of training samples. Our models trained with a small dataset produce segmentations of similar accuracy as expert human observers and generalised well to new data, performing within inter-observer variation.Significance.We empirically demonstrate the importance of highly consistent training samples when training a 3D auto-segmentation model for use in radiotherapy. Crucially, it is the consistency of the training segmentations which had a greater impact on model performance rather than the size of the dataset used.


Asunto(s)
Cabeza , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Cuello , Redes Neurales de la Computación , Tomografía Computarizada por Rayos X
15.
J Thorac Oncol ; 18(5): 599-607, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36738929

RESUMEN

INTRODUCTION: The RTOG 0617 trial presented a worse survival for patients with lung cancer treated in the high-dose (74 Gy) arm. In multivariable models, radiation level and whole-heart volumetric dose parameters were associated with survival. In this work, we consider heart subregions to explain the observed survival difference between radiation levels. METHODS: Voxel-based analysis identified anatomical regions where the dose was associated with survival. Bootstrapping clinical and dosimetric variables into an elastic net model selected variables associated with survival. Multivariable Cox regression survival models assessed the significance of dose to the heart subregion, compared with whole heart v5 and v30. Finally, the trial outcome was assessed after propensity score matching of patients on lung dose, heart subregion dose, and tumor volume. RESULTS: A total of 458 patients were eligible for voxel-based analysis. A region of significance (p < 0.001) was identified in the base of the heart. Bootstrapping selected mean lung dose, radiation level, log tumor volume, and heart region dose. The multivariable Cox model exhibited dose to the heart region (p = 0.02), and tumor volume (p = 0.03) were significantly associated with survival, and radiation level was not significant (p = 0.07). The models exhibited that whole heart v5 and v30 were not associated with survival, with radiation level being significant (p < 0.05). In the matched cohort, no significant survival difference was seen between radiation levels. CONCLUSIONS: Dose to the base of the heart is associated with overall survival, partly removing the radiation level effect, and explaining that worse survival in the high-dose arm is owing, in part, to the heart subregion dose. By defining a heart avoidance region, future dose escalation trials may be feasible.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Traumatismos por Radiación , Humanos , Neoplasias Pulmonares/patología , Carcinoma de Pulmón de Células no Pequeñas/patología , Pulmón/patología , Radiometría , Dosificación Radioterapéutica
16.
Adv Radiat Oncol ; 8(3): 101149, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36691449

RESUMEN

Purpose: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. Methods and Materials: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. Results: The average GTV was significantly larger on T1gd (0.57cm3) compared with T2 (0.51cm3, P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. Conclusions: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.

17.
Int J Radiat Oncol Biol Phys ; 115(2): 453-463, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35985456

RESUMEN

PURPOSE: Radiation cardiotoxicity (RC) is a clinically significant adverse effect of treatment for patients with thoracic malignancies. Clinical studies in lung cancer have indicated that heart substructures are not uniformly radiosensitive, and that dose to the heart base drives RC. In this study, we aimed to characterize late changes in gene expression using spatial transcriptomics in a mouse model of base regional radiosensitivity. METHODS AND MATERIALS: An aged female C57BL/6 mouse was irradiated with 16 Gy delivered to the cranial third of the heart using a 6 × 9 mm parallel opposed beam geometry on a small animal radiation research platform, and a second mouse was sham-irradiated. After echocardiography, whole hearts were collected at 30 weeks for spatial transcriptomic analysis to map gene expression changes occurring in different regions of the partially irradiated heart. Cardiac regions were manually annotated on the capture slides and the gene expression profiles compared across different regions. RESULTS: Ejection fraction was reduced at 30 weeks after a 16 Gy irradiation to the heart base, compared with the sham-irradiated controls. There were markedly more significant gene expression changes within the irradiated regions compared with nonirradiated regions. Variation was observed in the transcriptomic effects of radiation on different cardiac base structures (eg, between the right atrium [n = 86 dysregulated genes], left atrium [n = 96 dysregulated genes], and the vasculature [n = 129 dysregulated genes]). Disrupted biological processes spanned extracellular matrix as well as circulatory, neuronal, and contractility activities. CONCLUSIONS: This is the first study to report spatially resolved gene expression changes in irradiated tissues. Examination of the regional radiation response in the heart can help to further our understanding of the cardiac base's radiosensitivity and support the development of actionable targets for pharmacologic intervention and biologically relevant dose constraints.


Asunto(s)
Pulmón , Transcriptoma , Animales , Femenino , Ratones , Relación Dosis-Respuesta en la Radiación , Corazón , Pulmón/efectos de la radiación , Ratones Endogámicos C57BL
18.
J Thorac Oncol ; 18(1): 57-66, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36130693

RESUMEN

INTRODUCTION: Heart dose has emerged as an independent predictor of overall survival in patients with NSCLC treated with radiotherapy. Several studies have identified the base of the heart as a region of enhanced dose sensitivity and a potential target for cardiac sparing. We present a dosimetric analysis of overall survival in the multicenter, randomized PET-Plan trial (NCT00697333) and for the first time include left ventricular ejection fraction (EF) at baseline as a metric of cardiac function. METHODS: A total of 205 patients with inoperable stage II or III NSCLC treated with 60 to 72 Gy in 2 Gy fractions were included in this study. A voxel-wise image-based data mining methodology was used to identify anatomical regions where higher dose was significantly associated with worse overall survival. Univariable and multivariable Cox proportional hazards models tested the association of survival with dose to the identified region, established prognostic factors, and baseline cardiac function. RESULTS: A total of 172 patients remained after processing and censoring for follow-up. At 2-years posttreatment, a highly significant region was identified within the base of the heart (p < 0.005), centered on the origin of the left coronary artery and the region of the atrioventricular node. In multivariable analysis, the number of positron emission tomography-positive nodes (p = 0.02, hazard ratio = 1.13, 95% confidence interval: 1.02-1.25) and mean dose to the cardiac subregion (p = 0.02, hazard ratio = 1.11 Gy-1, 95% confidence interval: 1.02-1.21) were significantly associated with overall survival. There was a significant interaction between EF and region dose (p = 0.04) for survival, with contrast plots revealing a larger effect of region dose on survival in patients with lower EF values. CONCLUSIONS: This work validates previous image-based data mining studies by revealing a strong association between dose to the base of the heart and overall survival. For the first time, an interaction between baseline cardiac health and heart base dose was identified, potentially suggesting preexisting cardiac dysfunction exacerbates the impact of heart dose on survival.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Volumen Sistólico , Tomografía Computarizada por Rayos X , Función Ventricular Izquierda , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Tomografía de Emisión de Positrones
19.
J Appl Clin Med Phys ; 23(11): e13810, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36316761

RESUMEN

PURPOSE: To quantify the clinical practice of respiratory motion management in radiation oncology. METHODS: A respiratory motion management survey was designed and conducted based on clinician survey guidelines. The survey was administered to American Association of Physicists in Medicine (AAPM) members on 17 August 2020 and closed on 13 September 2020. RESULTS: A total of 527 respondents completed the entire survey and 651 respondents completed part of the survey, with the partially completed surveys included in the analysis. Overall, 84% of survey respondents used deep inspiration breath hold for left-sided breast cancer. Overall, 83% of respondents perceived respiratory motion management for thoracic and abdominal cancer radiotherapy patients to be either very important or required. Overall, 95% of respondents used respiratory motion management for thoracic and abdominal sites, with 36% of respondents using respiratory motion management for at least 90% of thoracic and abdominal patients. The majority (60%) of respondents used the internal target volume method to treat thoracic and abdominal cancer patients, with 25% using breath hold or abdominal compression and 13% using gating or tracking. CONCLUSIONS: A respiratory motion management survey has been completed by AAPM members. Respiratory motion management is generally considered very important or required and is widely used for breast, thoracic, and abdominal cancer treatments.


Asunto(s)
Oncología por Radiación , Humanos , Estados Unidos , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X/métodos , Contencion de la Respiración , Movimiento (Física) , Planificación de la Radioterapia Asistida por Computador/métodos , Encuestas y Cuestionarios
20.
Endocr Connect ; 11(12)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36269600

RESUMEN

Brain tumours make up nearly one-third of paediatric malignancies. Over time, advancements in oncological treatments like radiotherapy have helped reduce normal-tissue toxicity when treating cancers in the brain. However, clinicians are still facing a trade-off between treatment efficacy and potential side effects. The aim of this review is to address the late effects of cranial irradiation on the neuroendocrine system and to identify factors that make patients more vulnerable to radiation-induced endocrine sequelae. Radiation damage to the hypothalamic-pituitary axis, which orchestrates hormone release, can lead to endocrinopathy; up to 48.8% of children who have undergone cranial irradiation develop a hormone deficiency. This may lead to further health complications that can appear up to decades after the last treatment, lowering the patients' quality of life and increasing long-term costs as lifelong hormone replacement therapy may be required. Growth hormone deficiency is the most common sequelae, followed by either thyroid or gonadotropic hormone deficiency. Adrenocorticotropic hormone deficiency tends to be the least common. Identified factors that increase the risk of late endocrine deficiency include total radiation dose, age at treatment, and time since last treatment. However, as there are various other factors that may potentiate the damage, a universal solution proven to be most effective in sparing the endocrine tissues is yet to be identified. Until then, accounting for the identified risk factors during treatment planning may in some cases help reduce the development of endocrine sequelae in childhood cancer survivors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...