1.
J Biophotonics ; 13(6): e201960105, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32049426

RESUMEN

The increase histopathological evaluation of prostatectomy specimens rises the workload on pathologists. Automated histopathology systems, preferably directly on unstained specimens, would accelerate the pathology workflow. In this study, we investigate the potential of quantitative analysis of optical coherence tomography (OCT) to separate benign from malignant prostate tissue automatically. Twenty fixated prostates were cut, from which 54 slices were scanned by OCT. Quantitative OCT metrics (attenuation coefficient, residue, goodness-of-fit) were compared for different tissue types, annotated on the histology slides. To avoid misclassification, the poor-quality slides, and edges of annotations were excluded. Accurate registration of OCT data with histology was achieved in 31 slices. After removing outliers, 56% of the OCT data was compared with histopathology. The quantitative data could not separate malignant from benign tissue. Logistic regression resulted in malignant detection with a sensitivity of 0.80 and a specificity of 0.34. Quantitative OCT analysis should be improved before clinical use.


Asunto(s)
Neoplasias de la Próstata , Tomografía de Coherencia Óptica , Cara , Humanos , Masculino , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía
2.
Acta Oncol ; 58(6): 943-950, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30905243

RESUMEN

Objective: Delineation variation of esophageal tumors remains a large source of geometric uncertainty. In the present study, we investigated the inter- and intra-observer variation in esophageal gross tumor volume (GTV) delineation and the impact of endoscopically implanted fiducial markers on these variations. Material/Methods: Ten esophageal cancer patients with at least two markers endoscopically implanted at the cranial and caudal tumor borders and visible on the planning computed tomography (pCT) were included in this study. Five dedicated gastrointestinal radiation oncologists independently delineated GTVs on the pCT without markers and with markers. The GTV was first delineated on pCTs where markers were digitally removed and next on the original pCT with markers. Both delineation series were executed twice to determine intra-observer variation. For both the inter- and intra-observer analyses, the generalized conformity index (CIgen), and the standard deviation (SD) of the distances between delineated surfaces (i.e., overall, longitudinal, and radial SDs) were calculated. Linear mixed-effect models were used to compare the without and with markers series (α = 0.05). Results: Both the inter- and intra-observer CIgen were significantly larger in the series with markers than in the series without markers (p < .001). For the series without markers vs. with markers, the inter-observer overall SD, longitudinal SD, and radial SD was 0.63 cm vs. 0.22 cm, 1.44 cm vs. 0.42 cm, and 0.26 cm vs. 0.18 cm, respectively (p < .05); moreover, the intra-observer overall SD, longitudinal SD, and radial SD was 0.45 cm vs. 0.26 cm, 1.10 cm vs. 0.41 cm, and 0.22 cm vs. 0.15 cm, respectively (p < .05). Conclusion: The presence of markers at the cranial and caudal tumor borders significantly reduced both inter- and intra-observer GTV delineation variation, especially in the longitudinal direction. Our results endorse the use of markers in GTV delineation for esophageal cancer patients.


Asunto(s)
Adenocarcinoma/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Esofágicas/radioterapia , Marcadores Fiduciales , Variaciones Dependientes del Observador , Radioterapia/normas , Adenocarcinoma/metabolismo , Adenocarcinoma/patología , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patología , Neoplasias Esofágicas/metabolismo , Neoplasias Esofágicas/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Pronóstico , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos
3.
J Biophotonics ; 12(4): e201800274, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30565879

RESUMEN

Optical coherence tomography (OCT), enables high-resolution 3D imaging of the morphology of light scattering tissues. From the OCT signal, parameters can be extracted and related to tissue structures. One of the quantitative parameters is the attenuation coefficient; the rate at which the intensity of detected light decays in depth. To couple the quantitative parameters with the histology one-to-one registration is needed. The primary aim of this study is to validate a registration method of quantitative OCT parameters to histological tissue outcome through one-to-one registration of OCT with histology. We matched OCT images of unstained fixated prostate tissue slices with corresponding histology slides, wherein different histologic types were demarcated. Attenuation coefficients were determined by a supervised automated exponential fit (corrected for point spread function and sensitivity roll-off related signal losses) over a depth of 0.32 mm starting from 0.10 mm below the automatically detected tissue edge. Finally, the attenuation coefficients corresponding to the different tissue types of the prostate were compared. From the attenuation coefficients, we produced the squared relative residue and goodness-of-fit metric R2 . This article explains the method to perform supervised automated quantitative analysis of OCT data, and the one-to-one registration of OCT extracted quantitative data with histopathological outcomes.


Asunto(s)
Próstata/diagnóstico por imagen , Próstata/patología , Prostatectomía , Tomografía de Coherencia Óptica , Anciano , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Próstata/cirugía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía
4.
J Med Imaging (Bellingham) ; 5(4): 045501, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30840735

RESUMEN

Multiobjective optimization approaches for deformable image registration (DIR) remove the need for manual adjustment of key parameters and provide a set of solutions that represent high-quality trade-offs between objectives of interest. Choosing a desired outcome a posteriori is potentially far more insightful as differences between solutions can be immediately visualized. The purpose of this work is to investigate whether such an approach allows clinical experts to intuitively select their preferred DIR outcome. To this end, we developed a simplex-based tool for solution navigation and asked 10 clinical experts to use it to choose their preferred DIR outcome from sets of trade-off solutions obtained for 10 breast magnetic resonance DIR cases of low (prone-prone DIR; n = 5 ) and high (prone-supine DIR; n = 5 ) difficulty, of patients and volunteers, respectively. The usability of the software is subsequently evaluated by the observers using the system usability scale. Further, the quality of the selected DIR outcomes is evaluated using the mean target registration error. Results show that the users are able to identify and select high-quality DIR outcomes, and attested to high learnability and usability of our software, supporting the validity of the presumed added value of taking a multiobjective perspective on DIR in clinical practice.

5.
Radiother Oncol ; 102(1): 14-21, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21903287

RESUMEN

PURPOSE: The aim of this study was to measure and improve the quality of target volume delineation by means of national consensus on target volume definition in early-stage rectal cancer. METHODS AND MATERIALS: The CTV's for eight patients were delineated by 11 radiation oncologists in 10 institutes according to local guidelines (phase 1). After observer variation analysis a workshop was organized to establish delineation guidelines and a digital atlas, with which the same observers re-delineated the dataset (phase 2). Variation in volume, most caudal and cranial slice and local surface distance variation were analyzed. RESULTS: The average delineated CTV volume decreased from 620 to 460 cc (p<0.001) in phase 2. Variation in the caudal CTV border was reduced significantly from 1.8 to 1.2 cm SD (p=0.01), while it remained 0.7 cm SD for the cranial border. The local surface distance variation (cm SD) reduced from 1.02 to 0.74 for anterior, 0.63 to 0.54 for lateral, 0.33 to 0.25 for posterior and 1.22 to 0.46 for the sphincter region, respectively. CONCLUSIONS: The large variation in target volume delineation could significantly be reduced by use of consensus guidelines and a digital delineation atlas. Despite the significant reduction there is still a need for further improvement.


Asunto(s)
Oncología por Radiación/normas , Neoplasias del Recto/radioterapia , Atlas como Asunto , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Países Bajos , Posicionamiento del Paciente , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
6.
Med Phys ; 33(10): 3874-900, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17089851

RESUMEN

This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.


Asunto(s)
Neoplasias/radioterapia , Oncología por Radiación/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Respiración , Guías como Asunto , Humanos , Movimiento (Física) , Neoplasias/patología , Control de Calidad , Radiometría , Dosificación Radioterapéutica , Radioterapia Asistida por Computador , Factores de Tiempo , Tomografía Computarizada por Rayos X/métodos