Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Data ; 11(1): 483, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38729970

RESUMEN

The Sparsely Annotated Region and Organ Segmentation (SAROS) dataset was created using data from The Cancer Imaging Archive (TCIA) to provide a large open-access CT dataset with high-quality annotations of body landmarks. In-house segmentation models were employed to generate annotation proposals on randomly selected cases from TCIA. The dataset includes 13 semantic body region labels (abdominal/thoracic cavity, bones, brain, breast implant, mediastinum, muscle, parotid/submandibular/thyroid glands, pericardium, spinal cord, subcutaneous tissue) and six body part labels (left/right arm/leg, head, torso). Case selection was based on the DICOM series description, gender, and imaging protocol, resulting in 882 patients (438 female) for a total of 900 CTs. Manual review and correction of proposals were conducted in a continuous quality control cycle. Only every fifth axial slice was annotated, yielding 20150 annotated slices from 28 data collections. For the reproducibility on downstream tasks, five cross-validation folds and a test set were pre-defined. The SAROS dataset serves as an open-access resource for training and evaluating novel segmentation models, covering various scanner vendors and diseases.


Asunto(s)
Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero , Femenino , Humanos , Masculino , Procesamiento de Imagen Asistido por Computador
2.
Clin Neuroradiol ; 2024 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-38456912

RESUMEN

PURPOSE: Solitary fibrous tumor (SFT) of the orbit is a rare tumor that was first described in 1994. We aimed to investigate its imaging characteristics that may facilitate the differential diagnosis between SFT and other types of orbital tumors. MATERIAL AND METHODS: Magnetic resonance imaging (MRI) data of patients with immunohistochemically confirmed orbital SFT from 2002 to 2022 at a tertiary care center were retrospectively analyzed. Tumor location, size, morphological characteristics, and contrast enhancement features were evaluated. RESULTS: Of the 18 eligible patients 10 were female (56%) with a mean age of 52 years. Most of the SFTs were oval-shaped (67%) with a sharp margin (83%). The most frequent locations were the laterocranial quadrant (44%), the extraconal space (67%) and the dorsal half of the orbit (67%). A flow void phenomenon was observed in nearly all cases (94%). On the T1-weighted imaging, tumor signal intensity (SI) was significantly lower than that of the retrobulbar fat and appeared predominantly equivalent (82%) to the temporomesial brain cortex, while on T2-weighted imaging its SI remained equivalent (50%) or slightly hyperintense to that of brain cortex. More than half of the lesions showed a homogeneous contrast enhancement pattern with a median SI increase of 2.2-fold compared to baseline precontrast imaging. CONCLUSION: The SFT represents a rare orbital tumor with several characteristic imaging features. It was mostly oval-shaped with a sharp margin and frequently localized in the extraconal space and dorsal half of the orbit. Flow voids indicating hypervascularization were the most common findings.

3.
Invest Radiol ; 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37994150

RESUMEN

PURPOSE: The study aimed to develop the open-source body and organ analysis (BOA), a comprehensive computed tomography (CT) image segmentation algorithm with a focus on workflow integration. METHODS: The BOA combines 2 segmentation algorithms: body composition analysis (BCA) and TotalSegmentator. The BCA was trained with the nnU-Net framework using a dataset including 300 CT examinations. The CTs were manually annotated with 11 semantic body regions: subcutaneous tissue, muscle, bone, abdominal cavity, thoracic cavity, glands, mediastinum, pericardium, breast implant, brain, and spinal cord. The models were trained using 5-fold cross-validation, and at inference time, an ensemble was used. Afterward, the segmentation efficiency was evaluated on a separate test set comprising 60 CT scans. In a postprocessing step, a tissue segmentation (muscle, subcutaneous adipose tissue, visceral adipose tissue, intermuscular adipose tissue, epicardial adipose tissue, and paracardial adipose tissue) is created by subclassifying the body regions. The BOA combines this algorithm and the open-source segmentation software TotalSegmentator to have an all-in-one comprehensive selection of segmentations. In addition, it integrates into clinical workflows as a DICOM node-triggered service using the open-source Orthanc research PACS (Picture Archiving and Communication System) server to make the automated segmentation algorithms available to clinicians. The BCA model's performance was evaluated using the Sørensen-Dice score. Finally, the segmentations from the 3 different tools (BCA, TotalSegmentator, and BOA) were compared by assessing the overall percentage of the segmented human body on a separate cohort of 150 whole-body CT scans. RESULTS: The results showed that the BCA outperformed the previous publication, achieving a higher Sørensen-Dice score for the previously existing classes, including subcutaneous tissue (0.971 vs 0.962), muscle (0.959 vs 0.933), abdominal cavity (0.983 vs 0.973), thoracic cavity (0.982 vs 0.965), bone (0.961 vs 0.942), and an overall good segmentation efficiency for newly introduced classes: brain (0.985), breast implant (0.943), glands (0.766), mediastinum (0.880), pericardium (0.964), and spinal cord (0.896). All in all, it achieved a 0.935 average Sørensen-Dice score, which is comparable to the one of the TotalSegmentator (0.94). The TotalSegmentator had a mean voxel body coverage of 31% ± 6%, whereas BCA had a coverage of 75% ± 6% and BOA achieved 93% ± 2%. CONCLUSIONS: The open-source BOA merges different segmentation algorithms with a focus on workflow integration through DICOM node integration, offering a comprehensive body segmentation in CT images with a high coverage of the body volume.

4.
J Clin Med ; 11(24)2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36556049

RESUMEN

PURPOSE: We aimed to evaluate predictors of symptomatic intracranial hemorrhage (sICH) in acute ischemic stroke (AIS) patients following thrombectomy due to anterior large vessel occlusion (LVO). METHODS: Data on stroke patients from January 2018 to December 2020 in a tertiary care centre were retrospectively analysed. sICH was defined as intracranial hemorrhage associated with a deterioration of at least four points in the National Institutes of Health Stroke Scale (NIHSS) score or hemorrhage leading to death. A smoothed ridge regression model was run to analyse the impact of 15 variables on their association with sICH. RESULTS: Of the 174 patients (median age 77, 41.4% male), sICH was present in 18 patients. Short procedure time from groin puncture to reperfusion (per 10 min OR 1.24; 95% CI 1.071-1.435; p = 0.004) and complete reperfusion (TICI 3) (OR 0.035; 95% CI 0.003-0.378; p = 0.005) were significantly associated with a lower risk of sICH. On the contrary, successful reperfusion (TICI 3 and TICI 2b) was not associated with a lower risk of sICH (OR 0.508; 95% CI 0.131-1.975, p = 0.325). Neither the total time from symptom onset to reperfusion nor the intravenous thrombolysis was a predictor of sICH (per 10 min OR 1.0; 95% CI 0.998-1.001, p = 0.745) (OR 1.305; 95% CI 0.338-5.041, p = 0.697). CONCLUSION: Our findings addressed the paramount importance of short procedure time and complete reperfusion to minimize sICH risk. The total ischemic time from onset to reperfusion was not a predictor of sICH.

5.
Clin Neuroradiol ; 32(3): 839-847, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35244728

RESUMEN

PURPOSE: We aimed to investigate treatment effect of endovascular thrombectomy (EVT) on the change of National Institutes of Health Stroke Scale (NIHSS) scores in acute ischemic stroke (AIS) patients with anterior large vessel occlusion (LVO). Predictors of early neurological improvement (ENI) were assessed in those with successful reperfusion. METHODS: Data on stroke patients from January 2018 to December 2020 were retrospectively analyzed. Anterior LVO was defined as occlusion of internal carotid artery and/or M1/M2 branch of middle cerebral artery. A reduction of at least 8 NIHSS points at 24 h after EVT or NIHSS score ≤ 1 at discharge was defined as ENI. In patients with successful reperfusion (TICI score of 2b/3) and available CT perfusion (CTP) imaging, 20 variables were tested in a smoothed ridge regression for their association with ENI. RESULTS: One hundred seventy two out of 211 patients had successful perfusion with 54 patients achieving ENI. Impact of successful EVT on reducing NIHSS score grew continuously on a daily basis up to the date of discharge. 105 out of 172 patients were included in final regression model. Short time from onset to admission and from groin-puncture to reperfusion, young age, low prestroke disability, high baseline CTP ASPECTS and high follow-up non-contrast CT (NCCT) ASPECTS were significantly associated with ENI. Neither baseline NCCT ASPECTS nor the volume of penumbra or ischemic core measured on CTP were associated with ENI. CONCLUSION: CTP ASPECTS might better predict ENI than non-contrast CT at baseline in patients with successful reperfusion following EVT.


Asunto(s)
Isquemia Encefálica , Procedimientos Endovasculares , Accidente Cerebrovascular Isquémico , Trombectomía , Humanos , Imagen de Perfusión , Reperfusión , Estudios Retrospectivos , Accidente Cerebrovascular , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...