Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Appl Radiat Isot ; 170: 109633, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33588201

RESUMEN

At the National Metrology Institute of South Africa (NMISA) absolute activity measurements of γ-emitting radionuclides are maintained for longevity on a secondary standard ionization chamber. Because the ionization chamber has lower gas pressure than that normally produced by the manufacturer, this paper focuses attention on explaining a normalization scheme devised to allow NMISA to make use of the manufacturer's supplied radionuclide calibration factors when necessary. The applicability of the procedure is justified through analysis of some results from a comprehensive simulation of the chamber undertaken in an independent study. Comparisons of the derived normalized calibration factors against those obtained through measurement at NMISA are made for a variety of radionuclides.

2.
Appl Radiat Isot ; 160: 109070, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32351212

RESUMEN

The absolute activity of 18F was determined using 4πß-γ liquid scintillation coincidence counting using beta-efficiency extrapolation. An ionization chamber factor was determined for use during a SIRTI comparison, for which results are presented. A non-extrapolation method based on a detection efficiency analysis was also employed using an adaptation of the double-phototube coincidence efficiency for a threshold above the second monopeak. Results and uncertainty budgets for the two methods are presented and discussed.

3.
Phys Lett B ; 761: 281-286, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-28057978

RESUMEN

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

4.
Appl Radiat Isot ; 109: 276-280, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26631452

RESUMEN

This paper reports on absolute activity measurements of iron-59 made at the National Metrology Institute of South Africa (NMISA) via 4π(LS)ß-γ coincidence counting. The exercise formed part of an Asia Pacific Metrology Program (APMP) regional key comparison. Source data were analysed by the extrapolation technique for a number of gamma-ray window settings. In addition, a feasibility study was undertaken on a second technique; a non-extrapolation method based on a detection efficiency analysis. The reported activity concentration of the (59)Fe solution was determined with a relative uncertainty of 0.28% (k=1), the uncertainty being due mainly to the rate vs. efficiency fitting process. The result from the non-extrapolation method was lower than that given by extrapolation by 0.33%, within two standard deviations. Possible reasons for the small discrepancy are discussed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...