Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
EClinicalMedicine ; 72: 102641, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38840669

RESUMEN

Workplace violence (WPV) against healthcare workers (HCW) is a globally growing problem in healthcare systems. Despite decades of research and interventions violent incidents are rising in their severity and frequency. A structured review of PubMed and Scopus databases and supplementary internet searches, resulted in a synthesis of evidence covering multiple countries and healthcare worker populations. High rates of WPV are increasingly common due to unmet patient expectations, poor communication, long wait times and organizational factors such as resourcing and infrastructure. We highlight links between WPV and poor worker health outcomes, staff turnover, reduced patient safety and medical errors. Few prevention and mitigation activities have shown sustained effects, highlighting the challenges in understanding and addressing the complex interplay of factors that drive violence against HCWs. The rapidly rising incidence of WPV requires special consideration and action from multiple stakeholders including patients and visitors, healthcare providers, law enforcement, media and policy makers.

2.
Anesthesiology ; 140(3): 610-627, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38349760

RESUMEN

How general anesthetics work remains a topic of ongoing study. A parallel field of research has sought to identify methods to reverse general anesthesia. Reversal agents could shorten patients' recovery time and potentially reduce the risk of postoperative complications. An incomplete understanding of the mechanisms of general anesthesia has hampered the pursuit for reversal agents. Nevertheless, the search for reversal agents has furthered understanding of the mechanisms underlying general anesthesia. The study of potential reversal agents has highlighted the importance of rigorous criteria to assess recovery from general anesthesia in animal models, and has helped identify key arousal systems (e.g., cholinergic, dopaminergic, and orexinergic systems) relevant to emergence from general anesthesia. Furthermore, the effects of reversal agents have been found to be inconsistent across different general anesthetics, revealing differences in mechanisms among these drugs. The presynapse and glia probably also contribute to general anesthesia recovery alongside postsynaptic receptors. The next stage in the search for reversal agents will have to consider alternate mechanisms encompassing the tripartite synapse.


Asunto(s)
Anestésicos Generales , Animales , Humanos , Anestesia General/efectos adversos , Cafeína , Nivel de Alerta , Dopamina
3.
Anesth Analg ; 138(2): 337-349, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38215712

RESUMEN

Correct placement of supraglottic airway devices (SGDs) is crucial for patient safety and of prime concern of anesthesiologists who want to provide effective and efficient airway management to their patients undergoing surgery or procedures requiring anesthesia care. In the majority of cases, blind insertion of SGDs results in less-than-optimal anatomical and functional positioning of the airway devices. Malpositioning can cause clinical malfunction and result in interference with gas exchange, loss-of-airway, gastric inflation, and aspiration of gastric contents. A close match is needed between the shape and profile of SGDs and the laryngeal inlet. An adequate first seal (with the respiratory tract) and a good fit at the second seal of the distal cuff and the gastrointestinal tract are most desirable. Vision-guided insertion techniques are ideal and should be the way forward. This article recommends the use of third-generation vision-incorporated-video SGDs, which allow for direct visualization of the insertion process, corrective maneuvers, and, when necessary, insertion of a nasogastric tube (NGT) and/or endotracheal tube (ETT) intubation. A videoscope embedded within the SGD allows a visual check of the glottis opening and position of the epiglottis. This design affords the benefit of confirming and/or correcting a SGD's position in the midline and rotation in the sagittal plane. The first clinically available video laryngeal mask airways (VLMAs) and multiple prototypes are being tested and used in anesthesia. Existing VLMAs are still not perfect, and further improvements are recommended. Additional modifications in multicamera technology, to obtain a panoramic view of the SGD sitting correctly in the hypopharynx and to prove that correct sizes have been used, are in the process of production. Ultimately, any device inserted orally-SGD, ETT, NGT, temperature probe, transesophageal scope, neural integrity monitor (NIM) tubes-could benefit from correct vision-guided positioning. VLMAs also allow for automatic recording, which can be documented in clinical records of patients, and could be valuable during teaching and research, with potential value in case of legal defence (with an airway incident). If difficulties occur with the airway, documentation in the patient's file may help future anesthesiologists to better understand the real-time problems. Both manufacturers and designers of SGDs may learn from optimally positioned SGDs to improve the design of these airway devices.


Asunto(s)
Anestesia , Máscaras Laríngeas , Laringe , Humanos , Intubación Intratraqueal/métodos , Manejo de la Vía Aérea/métodos , Anestesia/métodos
5.
Saudi J Anaesth ; 17(4): 566-574, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37779574

RESUMEN

Demand for anesthesia and analgesia for the frail elderly is continuously increasing as the likelihood of encountering very elderly, very vulnerable, and very compromised patients has, ever so subtly, increased over the last three decades. The anesthesiologist has, increasingly, been obliged to offer professional services to frail patients. Fortunately, there has been a dramatic improvement in medications, methods of drug delivery, critical monitoring, and anesthesia techniques. Specific methodologies peculiar to the frail are now taught and practiced across all anesthesia subspecialties. However, administering anesthesia for the frail elderly is vastly different to giving an anesthetic to the older patient. Frail patients are increasingly cared for in specialized units-geriatric intensive therapy units, post-acute care services, palliative, hospices, and supportive care and aged care facilities. Several medications (e.g., morphine-sparing analgesics) more suited to the frail have become universally available in most centers worldwide so that best-practice, evidence-based anesthesia combinations of drugs and techniques are now increasingly employed. Every anesthetic and pain management techniques in the frail elderly patient are going to be discussed in this review.

6.
J Anesth ; 37(6): 971-975, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37814088

RESUMEN

Transcutaneous carbon dioxide measurement (TcCO2) offers the ability to continuously and non-invasively monitor carbon dioxide (CO2) tensions when end-tidal monitoring is not possible. The accuracy of TcCO2 has not been established in anesthetized apneic patients with obesity. In this secondary publication, we present a methods comparison analysis of TcCO2 with the gold standard arterial PCO2, in adult patients with body mass index (BMI) > 35kg/m2 who were randomized to receive high flow or low flow nasal oxygenation during post-induction apnea. Agreement between PaCO2 and TcCO2 at baseline, the start of apnea and the end of apnea were assessed using a non-parametric difference plot. Forty-two participants had a median (IQR) BMI of 52 (40-58.5) kg/m2. The mean (SD) PaCO2 was 33.9 (4.0) mmHg at baseline and 51.4 (7.5) mmHg at the end of apnea. The bias was the greatest at the end of apnea median (95% CI, 95% limits of agreement) 1.90 mmHg (-2.64 to 6.44, -7.10 to 22.90). Findings did not suggest significant systematic differences between the PaCO2 and TcCO2 measures. For a short period of apnea, TcCO2 showed inadequate agreement with PaCO2 in patients with BMI > 35 kg/m2. These techniques require comparison in a larger population, with more frequent sampling and over a longer timeframe, before TcCO2 can be confidently recommended in this setting.


Asunto(s)
Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono , Adulto , Humanos , Índice de Masa Corporal , Monitoreo de Gas Sanguíneo Transcutáneo/métodos , Apnea , Obesidad/complicaciones
8.
Intern Med J ; 53(10): 1806-1812, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36300865

RESUMEN

BACKGROUND: Globalisation has increased human movements around the world, spurring greater connectiveness and opportunities to collaborate. In an increasingly connected world, quality assurance among professionals is paramount, particularly in medical research where PhD (Doctor of Philosophy) degree holders are expected to be at the peak of their field and play advanced-level research, education and leadership roles. While some regional efforts have been made to ensure comparability in the standards of advanced degree training, no previous study has compared these standards for a PhD in medicine across the globe. AIMS: To explore the structural diversity of medical PhD degrees and identify which aspects benefit from greater harmonisation. METHODS: In 2021, the 10 best-ranked universities from each of the top five Western countries, and the top Asian country, were identified based on Quacquarelli Symonds World University Ranking. Data were collected for each university based on individual website information regarding the level of degree required to gain entry into a PhD programme in medicine and requirements for completion of coursework, journal publication and oral defence. RESULTS: Significant variations exist in the requirements for medical PhDs across the world in terms of prerequisite degree and inclusion of coursework. Oral defence is near universal, but a mandatory requirement for publication is largely absent. CONCLUSIONS: Harmonisation of medical PhD degrees through international standards should be considered to encourage quality improvement and benchmarking between institutions, as well as to facilitate greater ease of movement within the medical research community, improving international collaboration and individual career opportunities accordingly.


Asunto(s)
Investigación Biomédica , Medicina , Humanos , Curriculum
9.
Expert Rev Med Devices ; 19(11): 847-858, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36308748

RESUMEN

INTRODUCTION: Video laryngeal masks have become alternatives to classical supraglottic airway devices in recent years. This review provides information on the background of these new medical devices, the most popular and widely used video laryngeal masks, their advantages, disadvantages and their main applications in airway management. AREAS COVERED: In this review, the physical differences between video laryngeal masks and second-generation laryngeal mask airways, and their properties in specific clinical settings are discussed. EXPERT COMMENTARY: To limit airway-related morbidity, an optimal position of supraglottic airway devices must be the primary goal. Extensive research has shown that blindly inserted laryngeal mask can be malpositioned in 50% to 80% of the cases. Therefore, blind insertion should be the exception rather than the rule unlike current practice. Video laryngeal mask airways have clear advantages in routine use and in difficult airway management since they allow a vision-guided technique. Henceforth, the properties perceived in clinical practice must be endorsed with quality clinical evidence.


Asunto(s)
Máscaras Laríngeas , Humanos , Intubación Intratraqueal , Manejo de la Vía Aérea , Proyectos de Investigación
10.
Antimicrob Agents Chemother ; 66(7): e0041922, 2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35762797

RESUMEN

Guidelines for surgical prophylactic dosing of cefazolin in bariatric surgery vary in terms of recommended dose. This study aimed to describe the plasma and interstitial fluid (ISF) cefazolin pharmacokinetics in patients undergoing bariatric surgery and to determine an optimum dosing regimen. Abdominal subcutaneous ISF concentrations (measured using microdialysis) and plasma samples were collected at regular time points after administration of cefazolin 2 g intravenously. Total and unbound cefazolin concentrations were assayed and then modeled using Pmetrics. Monte Carlo dosing simulations (n = 5,000) were used to define cefazolin dosing regimens able to achieve a fractional target attainment (FTA) of >95% in the ISF suitable for the MIC for Staphylococcus aureus in isolates of ≤2 mg · L-1 and for a surgical duration of 4 h. Fourteen patients were included, with a mean (standard deviation [SD]) bodyweight of 148 (35) kg and body mass index (BMI) of 48 kg · m-2. Cefazolin protein binding ranged from 14 to 36% with variable penetration into ISF of 58% ± 56%. Cefazolin was best described as a four-compartment model including nonlinear protein binding. The mean central volume of distribution in the final model was 18.2 (SD 3.31) L, and the mean clearance was 32.4 (SD 20.2) L · h-1. A standard 2-g dose achieved an FTA of >95% for all patients with BMIs ranging from 36 to 69 kg · m-2. A 2-g prophylactic cefazolin dose achieves appropriate unbound plasma and ISF concentrations in obese and morbidly obese bariatric surgery patients.


Asunto(s)
Cirugía Bariátrica , Obesidad Mórbida , Antibacterianos , Cefazolina , Líquido Extracelular/metabolismo , Humanos , Obesidad Mórbida/metabolismo , Obesidad Mórbida/cirugía
11.
Anesth Analg ; 135(2): 427-434, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35580256

RESUMEN

Many procedures in science and medicine involve the use of a syringe, and its invention is a key milestone in general and regional anesthesia history. The end of the 19th century brought major changes in syringe production. An industry that initially manually crafted syringes to individual physicians' instructions saw the introduction of a large variety of syringes, sometimes with odd and unique modifications. For many of these unique syringes, there was no proven evidence that these modifications were effective or safe to use. This article provides examples of "odd" syringe designs for use in medicine, general anesthesia, and regional anesthesia. Some designs proved functional and have stood the test of time; others quickly disappeared and ended up in dusty collections.


Asunto(s)
Anestesia , Médicos , Humanos , Jeringas
13.
J Clin Monit Comput ; 36(4): 921-928, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34919170

RESUMEN

Numerous studies have shown that blindly inserted supraglottic airway devices (SADs) are sub-optimally placed in 50 to 80% of all cases. Placement under direct vision has been recommended. We describe the very first two new SADs of the third generation that incorporate a videoscope with flexible tip. Both devices are made up of two interlocking components-the SAD and a videoscope. The 3rd generation, direct vision SADs allow vision-guided insertion, corrective manoeuvres, if needed, and correct placement in the hypopharynx and possess additional features which permit insertion of a gastric tube and endotracheal intubation should the need arise. This article describes the two new devices' physical characteristics, features, rationale for use, advantages and limitations in comparison to existing devices. Each of the two new devices-the Video Laryngeal Mask (VLMTM, UE Medical®) and the SafeLM® Video Laryngeal Mask System (SafeLMTM VLMS, Magill Medical Technology®) consist of two parts: (a) a disposable 2nd generation SAD with a silicone cuff and an anatomically curved tube; and (b) a reusable patient-isolated videoscope and monitoring screen, with the flexible scope located into a specially-designed, blind-end channel terminating in the bowl of the SAD, preventing the videoscope from contacting patient body fluids in the SAD bowl. Third generation placement-under-direct-vision supraglottic airway devices possess several theoretical safety and ease of use advantages which now need to be validated in clinical use.


Asunto(s)
Máscaras Laríngeas , Humanos , Intubación Intratraqueal
14.
Anesth Prog ; 68(2): 107-113, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-34185866

RESUMEN

Nasotracheal intubation remains an underused but invaluable technique for securely managing the airway during oral and maxillofacial surgery. In this article, we present a modified clinical technique that allows for the potential introduction into clinical practice of 2 new airway devices: a nasal laryngeal mask airway and an interchangeable oral/nasal endotracheal tube. We hypothesize that with the use of proper techniques, these devices can add new and safer alternatives for securing an airway by the nasal route. The advantage of this novel technique is that the airway is secured by the oral route prior to performing a modified retrograde nasal intubation, eliminating the danger of profuse epistaxis precipitating a "cannot intubate, cannot ventilate" scenario. In addition, the design and materials used in the components of the devices may minimize trauma. The authors aim to inform clinicians about the indications, physical characteristics, and insertion/removal techniques related to these new devices.


Asunto(s)
Intubación Intratraqueal , Máscaras Laríngeas , Epistaxis/etiología , Epistaxis/prevención & control , Humanos , Intubación Intratraqueal/efectos adversos , Nariz
15.
J Clin Monit Comput ; 35(2): 217-224, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-32537697

RESUMEN

Although 1st and 2nd generation supraglottic airway devices (SADs) have many desirable features, they are nevertheless inserted in a similar 'blind' way as their 1st generation predecessors. Clinicians mostly still rely entirely on subjective indirect assessments to estimate correct placement which supposedly ensures a tight seal. Malpositioning and potential airway compromise occurs in more than half of placements. Vision-guided insertion can improve placement. In this article we propose the development of a 3rd generation supraglottic airway device, equipped with cameras and fiberoptic illumination, to visualise insertion of the device, enable immediate manoeuvres to optimise SAD position, verify whether correct 1st and 2nd seals are achieved and check whether size selected is appropriate. We do not provide technical details of such a '3rd generation' device, but rather present a theoretical analysis of its desirable properties, which are essential to overcome the remaining limitations of current 1st and 2nd generation devices. We also recommend that this further milestone improvement, i.e. ability to place the SAD accurately under direct vision, be eligible for the moniker '3rd generation'. Blind insertion of SADs should become the exception and we anticipate, as in other domains such as central venous cannulation and nerve block insertions, vision-guided placement becoming the gold standard.


Asunto(s)
Manejo de la Vía Aérea/instrumentación , Diseño de Equipo , Glotis , Intubación Intratraqueal/instrumentación , Máscaras Laríngeas , Manejo de la Vía Aérea/tendencias , Tecnología de Fibra Óptica , Humanos , Intubación Intratraqueal/tendencias , Visión Ocular
18.
J Clin Monit Comput ; 34(2): 285-294, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30953222

RESUMEN

The laryngeal mask airways supreme (LMA-Supreme™) and protector (LMA-Protector™) are generally placed blindly, often resulting in a less than optimal position and vision-guided placement has been recommended. This prospective, randomized controlled study compared the efficacy of airway seal by measuring the oropharyngeal leak pressure in 100 surgical patients who underwent a variety of non-thoracic surgery under general anaesthesia, suitable with a supraglottic airway device. Patients were allocated to either the LMA-Supreme (n = 50) or LMA-Protector (n = 50) group. All insertions were performed under vision of a videolaryngoscope using an 'insert-detect-correct-as-you-go' technique with standardized corrective measures. Our primary endpoint, mean oropharyngeal leak pressure, was significantly higher in the LMA-Protector (31.7 ± 2.9 cm H2O) compared to the LMA-Supreme (27.7 ± 3.5 cm H2O) group (mean difference 4.0 cm H2O, 95% confidence interval (CI) 2.7-5.3 cm H2O, p < 0.001) after achieving a near-optimal fibreoptic position in the LMA-Protector (94%) and LMA-Supreme (96%) groups. No statistically significant differences were shown for secondary outcomes of alignment, number of insertion attempts and malpositions, and final anatomical position as scored by fibreoptic evaluation. Corrective manoeuvres were required in virtually all patients to obtain a correct anatomically positioned LMA. Position outcomes of the two devices were similar except for the proportion of procedures with folds in the proximal cuff (90% LMA-Supreme vs. 2% LMA-Protector, p < 0.001), the need for intracuff pressure adjustments (80% LMA-Supreme vs. 48% LMA-Protector, p = 0.001) and size correction (18% LMA-Supreme vs. 4% LMA-Protector, p = 0.025). In conclusion, a higher oropharyngeal leak pressure can be achieved with LMA-Protector compared to LMA-Supreme with optimal anatomical position when insertion is vision-guided.


Asunto(s)
Manejo de la Vía Aérea/instrumentación , Máscaras Laríngeas , Adulto , Anestesia General , Diseño de Equipo , Femenino , Tecnología de Fibra Óptica , Humanos , Laringoscopios , Masculino , Persona de Mediana Edad , Presión , Estudios Prospectivos
19.
Waste Manag Res ; 37(1): 3-19, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30132405

RESUMEN

Healthcare waste is a rampant issue in Australian hospitals. The operating room (OR) contributes disproportionately to total hospital waste. There has been considerable research in the literature concentrating on strategies to improve OR and hospital waste accumulation, in an attempt to provide guidance and direction on how to reduce the healthcare ecological footprint. We reviewed the literature for leading greening initiatives currently utilised in the OR in Australia and internationally. This narrative literature review focuses on the trend of OR greening initiatives over the last 25 years, comparing different innovative approaches, the successes and setbacks, and the financial implications of initiatives. A variety of measures that hospital management, surgeons, anaesthetists, nurses and other healthcare personnel can take to reduce the ecological footprint of their healthcare facility are outlined. Greening initiatives include reducing, recycling, reusing, rethinking and researching, as well as novel technology and smarter architectural design. We also evaluated the barriers to improving waste management, which include lack of leadership, misconceptions among staff, and an overall resistance to change. In conclusion, in a world where greenhouse gas emissions cause unprecedented climate change and landfill space is finite, it is incumbent upon hospitals to help reduce the environmental impact of their facility. Reducing pollution and greenhouse gas emissions would moderate the incidence of human disease, save money for the healthcare system and society as a whole, and contribute to a safer and healthier world we all would like to live in.


Asunto(s)
Eliminación de Residuos , Administración de Residuos , Australia , Efecto Invernadero , Humanos , Quirófanos , Reciclaje , Instalaciones de Eliminación de Residuos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...