Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
EuroIntervention ; 15(12): e1090-e1098, 2019 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-30888959

RESUMEN

AIMS: The aim of this study was to evaluate the impact of 23-month ticagrelor monotherapy following one-month dual antiplatelet therapy (DAPT) after percutaneous coronary intervention (PCI) on the rates of patient-oriented composite endpoints (POCE) and net adverse clinical events (NACE). METHODS AND RESULTS: The rates of site-reported Academic Research Consortium (ARC)-2 defined POCE (all-cause death, any stroke, any myocardial infarction or any revascularisation) and NACE (POCE or bleeding type 3 or 5 according to the Bleeding ARC [BARC]) were reported up to two years by intention-to-treat principle in the randomised, multicentre, open-label GLOBAL LEADERS study comparing two antiplatelet strategies in 15,991 patients undergoing PCI. The experimental strategy consisted of aspirin with ticagrelor for one month followed by ticagrelor monotherapy for 23 months, whereas the reference treatment consisted of 12-month DAPT followed by 12-month aspirin monotherapy. At two years, POCE occurred in 1,050 (13.2%) patients in the experimental group and in 1,131 (14.2%) in the reference group (HR 0.93, 95% CI: 0.85-1.01, p=0.085). NACE occurred in 1,145 (14.4%) patients in the experimental group and in 1,237 (15.5%) patients in the reference group (HR 0.92, 95% CI: 0.85-1.00, p=0.057). In pre-specified subgroup analyses, no significant treatment-by-subgroup interactions were found for either POCE or NACE at two years. CONCLUSIONS: The experimental treatment strategy of one-month DAPT followed by 23 months of ticagrelor alone did not result in a significant reduction in the rates of site-reported POCE or NACE, when compared to the reference treatment. ClinicalTrials.gov Identifier: NCT01813435.


Asunto(s)
Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/uso terapéutico , Ticagrelor/uso terapéutico , Clopidogrel , Quimioterapia Combinada , Humanos , Resultado del Tratamiento
2.
EuroIntervention ; 13(17): 2026-2035, 2018 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-28923787

RESUMEN

AIMS: A second iteration of a sirolimus-eluting stent (SES) that has a biodegradable PLGA polymer coating with an electrografting base layer on a thin-strut (80 µm) cobalt-chromium platform (BuMA Supreme; SINOMED, Tianjin, China) has been developed. This first-in-man trial aimed to assess the efficacy and safety of the novel device. METHODS AND RESULTS: This randomised, multicentre, single-blinded, non-inferiority trial compared the BuMA Supreme SES versus a contemporary durable polymer zotarolimus-eluting stent (ZES) in terms of angiographic in-stent late lumen loss (LLL) at nine-month follow-up as the primary endpoint. A total of 170 patients were randomly allocated to treatment with either SES (n=83) or ZES (n=87). At nine-month angiographic follow-up, in-stent LLL was 0.29±0.33 mm in the SES group and 0.14±0.37 mm in the ZES group (pnon-inferiority=0.45). The in-stent percent diameter stenosis and the binary restenosis rate of the two treatment arms were similar (19.2±12.0% vs. 16.1±12.6%, p=0.09, and 3.3% vs. 4.4%, p=1.00, respectively). At 12-month clinical follow-up, there was no difference between treatment arms with regard to the device-oriented composite clinical endpoint (4.9% vs. 5.7%; p=0.72). CONCLUSIONS: The PIONEER trial did not meet its primary endpoint in terms of in-stent LLL at nine-month follow-up. However, this result did not translate into any increase in restenosis rate or impairment in 12-month clinical outcomes.


Asunto(s)
Implantes Absorbibles/efectos adversos , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Sirolimus/farmacología , Anciano , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis
3.
EuroIntervention ; 14(5): e570-e579, 2018 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-28994655

RESUMEN

AIMS: Quantitative flow ratio (QFR) based on three-dimensional quantitative coronary angiography (3D-QCA) is a novel method to assess physiological functionality after treatment with stents. The current study aimed to evaluate the difference in physiological functionality nine months after implantation of a bioresorbable polymer-based sirolimus-eluting stent with an electrografting base layer (BuMA Supreme: B-SES) versus a durable polymer-based zotarolimus-eluting stent (Resolute: R-ZES). METHODS AND RESULTS: The current post hoc analysis was performed in the PIONEER randomised trial (1:1 randomisation to B-SES [83 patients/95 lesions] and R-ZES [87 patients/101 lesions]). QFR was measured in stented vessels in both arms at preprocedural, post-procedural and nine-month angiography without pharmacologically induced hyperaemia (contrast QFR). At nine months, both the values of QFR distal to the stent (B-SES: 0.89±0.10 vs. R-ZES: 0.89±0.11, p=0.97) and the number of vessels with QFR ≤0.8 were not significantly different between the two groups (11.0% vs. 12.8%, p=0.72), while the in-stent binary restenosis rate was also comparable (3.7% vs. 3.5%, p=1.00). QFR gradient across the device (∆QFR) at nine months was also similar between the groups (B-SES: 0.03±0.04 vs. R-ZES: 0.03±0.07, p=0.95). CONCLUSIONS: Quantitative flow assessment nine months after stenting did not differ between B-SES and R-ZES, despite a significant difference in in-stent late lumen loss.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Humanos , Polímeros , Diseño de Prótesis , Sirolimus/análogos & derivados , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...