Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Clin Transl Radiat Oncol ; 43: 100676, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37753461

RESUMEN

Purpose: To report on the late toxicity and local control (LC) of head and neck cancer patients treated with adaptive FDG-PET/CT response-guided radiotherapy (ADMIRE) with dose escalation (NCT03376386). Materials and methods: Between December 2017 and April 2019, 20 patients with stage II-IV squamous cell carcinoma of the larynx, hypopharynx or oropharynx were treated within the ADMIRE study where FDG-PET/CT response-guided (Week 2&4) dose escalation was applied (total dose 70-78 Gy). Cisplatin or cetuximab was added to radiotherapy in case of T3-4 and/or N2c disease. To compare the LC and late toxicity of the study population, we used an external control group (n = 67) consisting of all eligible patients for the study (but not participated). These patients were treated in our institution during the same period with the current standard of 70 Gy radiotherapy. To reduce the effect of confounding, logistic regression analyses was done using stabilized inverse probability of treatment weighting (SIPTW). Results: After median follow-up of 40 and 43 months for the ADMIRE and control groups, the 3-year LC-rates were 74% and 78%, respectively (adjusted HR after SIPTW 0.80, 95 %CI 0.25-2.52, p = 0.70). The incidences of any late G3 toxicity were 35% and 18%, respectively. The adjusted OR for any late G3 toxicity was 5.09 (95 %CI 1.64-15.8, p = 0.005), for any late G ≥ 2 toxicity was 3.67 (95 %CI 1.2-11.7, p = 0.02), for persistent laryngeal edema was 10.95 (95% CI 2.71-44.29, p = 0.001), for persistent mucosal ulcers was 4.67 (95% CI 1.23-17.7, p = 0.023), and for late G3 radionecrosis was 15.69 (95 %CI 2.43-101.39, p = 0.004). Conclusion: Given the comparable LC rates with increased late toxicity in the ADMIRE group, selection criteria for future adaptive dose escalation trials (preferably randomized) need to be refined to include only patients at higher risk of local failure and/or lower risk of severe late toxicity.

2.
Cancers (Basel) ; 15(12)2023 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-37370839

RESUMEN

INTRODUCTION: Some aspects of the treatment protocol for breast cancer during pregnancy (PrBC) have not been thoroughly studied. This study provides clarity regarding the safety of the use of 125I-seeds as a localization technique for breast-conserving surgery in patients with PrBC. METHODS: To calculate the exposure to the fetus of one 125I-seed implanted in a breast tumor, we developed a model accounting for the decaying 125I-source, time to surgery, and the declining distance between the 125I-seed and the fetus. The primary outcome was the maximum cumulative fetal dose of radiation at consecutive gestational ages (GA). RESULTS: The cumulative fetal dose remains below 1 mSv if a single 125I-seed is implanted at a GA of 26 weeks. After a GA of 26 weeks, the fetal dose can be at a maximum of 11.6 mSv. If surgery takes place within two weeks of implantation from a GA of 26 weeks, and one week above a GA of 32 weeks, the dose remains below 1 mSv. CONCLUSION: The use of 125I-seeds is safe in PrBC. The maximum fetal exposure remains well below the threshold of 100 mSv, and therefore, does not lead to an increased risk of fetal tissue damage. Still, we propose keeping the fetal dose as low as possible, preferably below 1 mSv.

4.
Radiother Oncol ; 177: 164-171, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36368471

RESUMEN

BACKGROUND AND PURPOSE: Xerostomia remains a common side effect of radiotherapy (RT) for patients with head and neck (H&N) cancer despite advancements in treatment planning and delivery. Secretory salivary gland cells express the prostate-specific membrane antigen (PSMA), and show significant uptake on PET scans using 68Ga/18F-PSMA-ligands. We aimed to objectively quantify the dose-response of salivary glands to RT using PSMA PET. METHODS AND MATERIALS: 28H&N cancer patients received RT with 70 Gy in 35 fractions over 7 weeks. PSMA PET/CT was acquired at baseline (BL), during treatment (DT) and at 1-&6-months post-treatment (PT1M/PT6M). Dose, BL- PT1M- and PT6M-SUV were extracted for every voxel inside each parotid (PG) and submandibular (SMG) gland. The PT1M/6M data was analysed using a generalised linear mixed effects model.Patient-reported xerostomia and DT-PSMA loss was also analysed. RESULTS: Dose had a relative effect on BL SUV. For a population average gland (BL-SUV of 10), every 1 Gy increment, decreased the PT1M/PT6M-SUV by 1.6 %/1.6 % for PGs and by 0.9 %/1.8 % for SMGs. TD50 of the population curves was 26.5/31.3 Gy for PGs, and 22.9/27.8 Gy for SMGs at PT1M /PT6M. PSMA loss correlated well with patient-reported xerostomia at DT/PT1M (Spearman's ρ = -0.64, -0.50). CONCLUSION: A strong relationship was demonstrated between radiation dose and loss of secretory cells in salivary glands derived using PSMA PET/CT. The population curve could potentially be used as a dose planning objective, by maximising the predicted post-treatment SUV. BL scans could be used to further tailor this to individual patients.


Asunto(s)
Neoplasias de Cabeza y Cuello , Xerostomía , Masculino , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Glándulas Salivales/diagnóstico por imagen , Xerostomía/diagnóstico por imagen , Xerostomía/etiología , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias de Cabeza y Cuello/metabolismo , Tomografía de Emisión de Positrones
5.
Int J Part Ther ; 8(1): 354-365, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34285961

RESUMEN

In the Netherlands, the model-based approach is used to identify patients with head and neck cancer who may benefit most from proton therapy in terms of prevention of late radiation-induced side effects in comparison with photon therapy. To this purpose, a National Indication Protocol Proton therapy for Head and Neck Cancer patients (NIPP-HNC) was developed, which has been approved by the health care authorities. When patients qualify according to the guidelines of the NIPP-HNC, proton therapy is fully reimbursed. This article describes the procedures that were followed to develop this NIPP-HNC and provides all necessary information to introduce model-based selection for patients with head and neck cancer into routine clinical practice.

6.
Radiother Oncol ; 160: 107-114, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33872642

RESUMEN

PURPOSE: To test if the relative change in FDG-PET SUVmax over the course of treatment was associated with disease progression and overall survival. Additionally, the prognostic values of other first-order PET-metric changes were investigated. METHODS: The study included 38 patients with stage II-III NSCLC, who underwent concurrent chemoradiotherapy. Patients received two pre-treatment FDG-PET scans and four during-treatment scans at weekly intervals. SUVmax was normalized to the start of treatment and analyzed using linear regression. Linear regression coefficients of other first order PET-metrics were grouped according to dissimilarity. Associations to patient outcome were analyzed using Cox hazard ratio. RESULTS: Twenty-eight patients satisfied the criteria for analysis. All PET-metrics demonstrated a strong linear correlation with time during treatment [median R-range: -0.87: -0.97]. No strong associations (p > 0.10) were found for the relative slope of SUVmax to patient outcomes. Other first-order metrics did correlate with outcome but the single imaging time-point maximizing the association of PET response with outcome varied per PET metric and outcome parameter. CONCLUSION: All investigated FDG PET metrics linearly decreased during treatment. Relative change in SUVmax was not associated to patient outcome while several other first order PET-metrics were related to patient outcome. A single optimal imaging time-point could not be identified.


Asunto(s)
Fluorodesoxiglucosa F18 , Neoplasias Pulmonares , Benchmarking , Quimioradioterapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Pronóstico , Radiofármacos , Estudios Retrospectivos
7.
Strahlenther Onkol ; 197(9): 791-801, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33825916

RESUMEN

PURPOSE: Respiratory-induced motion of oesophageal tumours and lymph nodes can influence positron-emission tomography/computed tomography (PET/CT). The aim was to compare standard three-dimensional (3D) and motion-compensated PET/CT regarding standardized uptake value (SUV), metabolic tumour volume (MTV) and detection of lymph node metastases. METHODS: This prospective observational study (NCT02424864) included 37 newly diagnosed oesophageal cancer patients. Diagnostic PET/CT was reconstructed in 3D and motion-compensated PET/CT. MTVs of the primary tumour were calculated using an automated region-growing algorithm with SUV thresholds of 2.5 (MTV2.5) and ≥ 50% of SUVmax (MTV50%). Blinded for reconstruction method, a nuclear medicine physician assessed all lymph nodes showing 18F­fluorodeoxyglucose uptake for their degree of suspicion. RESULTS: The mean (95% CI) SUVmax of the primary tumour was 13.1 (10.6-15.5) versus 13.0 (10.4-15.6) for 3D and motion-compensated PET/CT, respectively. MTVs were also similar between the two techniques. Bland-Altman analysis showed mean differences between both measurements (95% limits of agreement) of 0.08 (-3.60-3.75), -0.26 (-2.34-1.82), 4.66 (-29.61-38.92) cm3 and -0.95 (-19.9-18.0) cm3 for tumour SUVmax, lymph node SUVmax, MTV2.5 and MTV50%, respectively. Lymph nodes were classified as highly suspicious (30/34 nodes), suspicious (20/22) and dubious (66/59) for metastases on 3D/motion-compensated PET/CT. No additional lymph node metastases were found on motion-compensated PET/CT. SUVmax of the most intense lymph nodes was similar for both scans: mean (95% CI) 6.6 (4.3-8.8) and 6.8 (4.5-9.1) for 3D and motion-compensated, respectively. CONCLUSION: SUVmax of the primary oesophageal tumour and lymph nodes was comparable on 3D and motion-compensated PET/CT. The use of motion-compensated PET/CT did not improve lymph node detection.


Asunto(s)
Neoplasias Esofágicas , Fluorodesoxiglucosa F18 , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/patología , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática/diagnóstico por imagen , Metástasis Linfática/patología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos
8.
PLoS One ; 16(2): e0247428, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33606831

RESUMEN

BACKGROUND: Every week, radiotherapy centers face the complex task of scheduling hundreds of treatment sessions amongst the available linear accelerators. With the increase in cancer patient numbers, manually creating a feasible and efficient schedule has shown to be a difficult, time-consuming task. Although operations research models have been increasingly reported upon to optimize patient care logistics, there is almost no scientific evidence of implementation in practice. METHODS: A mathematical operations research model was adapted to generate radiotherapy treatment schedules in two Dutch centers. The model was iteratively adjusted to fulfill the technical and medical constraints of each center until a valid model was attained. Patient data was collected for the planning horizon of one week, and the feasibility of the obtained schedules was verified by the staff of each center. The resulting optimized solutions are compared with the ones manually developed in practice. RESULTS: The weekly schedule was improved in both centers by decreasing the average standard deviation between sessions' starting times from 103.0 to 50.4 minutes (51%) in one center, and the number of gaps in the schedule from 18 to 5 (72%) in the other. The number of patients requiring linac switching between sessions has also decreased from 71 to 0 patients in one center, and from 43 to 2 in the other. The automated process required 5 minutes and 1.5 hours of computation time to find an optimal weekly patient schedule, respectively, as opposed to approximately 1.5 days when performed manually for both centers. CONCLUSIONS: The practical application of a theoretical operations research model for radiotherapy treatment scheduling has provided radiotherapy planners a feasible, high-quality schedule in an automated way. Iterative model adaptations performed in small steps, early engagement of stakeholders, and constant communication proved to facilitate the implementation of operations research models into clinical practice.


Asunto(s)
Neoplasias/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios de Factibilidad , Humanos , Modelos Teóricos , Países Bajos , Investigación Operativa , Admisión y Programación de Personal
9.
Health Care Manag Sci ; 23(4): 520-534, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32594285

RESUMEN

External-beam radiotherapy treatments are delivered by a linear accelerator (linac) in a series of high-energy radiation sessions over multiple days. With the increase in the incidence of cancer and the use of radiotherapy (RT), the problem of automatically scheduling RT sessions while satisfying patient preferences regarding the time of their appointments becomes increasingly relevant. While most literature focuses on timeliness of treatments, several Dutch RT centers have expressed their need to include patient preferences when scheduling appointments for irradiation sessions. In this study, we propose a mixed-integer linear programming (MILP) model that solves the problem of scheduling and sequencing RT sessions considering time window preferences given by patients. The MILP model alone is able to solve the problem to optimality, scheduling all sessions within the desired window, in reasonable time for small size instances up to 66 patients and 2 linacs per week. For larger centers, we propose a heuristic method that pre-assigns patients to linacs to decompose the problem in subproblems (clusters of linacs) before using the MILP model to solve the subproblems to optimality in a sequential manner. We test our methodology using real-world data from a large Dutch RT center (8 linacs). Results show that, combining the heuristic with the MILP model, the problem can be solved in reasonable computation time with as few as 2.8% of the sessions being scheduled outside the desired time window.


Asunto(s)
Citas y Horarios , Prioridad del Paciente , Radioterapia , Humanos , Países Bajos , Servicio de Medicina Nuclear en Hospital/organización & administración , Aceleradores de Partículas , Programación Lineal , Factores de Tiempo
10.
Int J Radiat Oncol Biol Phys ; 108(4): 960-968, 2020 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-32361007

RESUMEN

PURPOSE: We investigated in a single-center prospective trial (NCT03376386) the use of serial fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET)/computed tomography (CT) to determine the boost dose and to guide boost segmentation in head and neck cancer. METHODS AND MATERIALS: Patients were eligible when treated with curative radiation therapy with or without systemic treatment for T2-4 squamous cell carcinoma of the hypopharynx, larynx, or oropharynx (20 patients in total). FDG-PET/CT scans were made at baseline and for redelineation and replanning at the end of weeks 2 and 4 of radiation therapy. The metabolically active part of the primary tumor received a 4 Gy boost on top of the 70 Gy baseline dose per partial metabolic response. The study would be considered feasible when ≥80% of adaptations were successful and no Common Terminology Criteria for Adverse Events grade ≥4 acute toxicity occurred. RESULTS: One patient received 70 Gy after complete metabolic response in week 2, and 12 patients received 78 Gy because of partial metabolic response at weeks 2 and 4. Seven patients received 74 Gy, either because of complete metabolic response at week 4 (n = 3) or a missed FDG-PET/CT (n = 4). The patients missed their FDG-PET/CT scans because they did not fast (n = 2) or at patients' request (n = 2). In addition to the 4 missed FDG-PET/CT scans, 2 adaptive plans could not be finished successfully owing to logistical problems. In total, 85% of adaptations were completed correctly. No patient experienced grade ≥4 toxicity, and 40% had grade 3 dysphagia (tube feeding) during treatment. This decreased at 12 weeks posttreatment to 20%. CONCLUSIONS: This prospective trial demonstrates the feasibility of serial FDG-PET/CT scans for dose escalation and patient selection.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radioterapia Guiada por Imagen/métodos , Radioterapia de Intensidad Modulada/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Anciano , Estudios de Factibilidad , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Humanos , Neoplasias Hipofaríngeas/diagnóstico por imagen , Neoplasias Hipofaríngeas/tratamiento farmacológico , Neoplasias Hipofaríngeas/radioterapia , Neoplasias Laríngeas/diagnóstico por imagen , Neoplasias Laríngeas/tratamiento farmacológico , Neoplasias Laríngeas/radioterapia , Persona de Mediana Edad , Neoplasias Orofaríngeas/diagnóstico por imagen , Neoplasias Orofaríngeas/tratamiento farmacológico , Neoplasias Orofaríngeas/radioterapia , Estudios Prospectivos , Radiofármacos , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/efectos adversos , Radioterapia de Intensidad Modulada/efectos adversos , Carcinoma de Células Escamosas de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas de Cabeza y Cuello/tratamiento farmacológico
11.
PLoS One ; 15(2): e0228793, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32097418

RESUMEN

In locally advanced lung cancer, established baseline clinical variables show limited prognostic accuracy and 18F-fluorodeoxyglucose positron emission tomography (FDG PET) radiomics features may increase accuracy for optimal treatment selection. Their robustness and added value relative to current clinical factors are unknown. Hence, we identify robust and independent PET radiomics features that may have complementary value in predicting survival endpoints. A 4D PET dataset (n = 70) was used for assessing the repeatability (Bland-Altman analysis) and independence of PET radiomics features (Spearman rank: |ρ|<0.5). Two 3D PET datasets combined (n = 252) were used for training and validation of an elastic net regularized generalized logistic regression model (GLM) based on a selection of clinical and robust independent PET radiomics features (GLMall). The fitted model performance was externally validated (n = 40). The performance of GLMall (measured with area under the receiver operating characteristic curve, AUC) was highest in predicting 2-year overall survival (0.66±0.07). No significant improvement was observed for GLMall compared to a model containing only PET radiomics features or only clinical variables for any clinical endpoint. External validation of GLMall led to AUC values no higher than 0.55 for any clinical endpoint. In this study, robust independent FDG PET radiomics features did not have complementary value in predicting survival endpoints in lung cancer patients. Improving risk stratification and clinical decision making based on clinical variables and PET radiomics features has still been proven difficult in locally advanced lung cancer patients.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Procesamiento de Imagen Asistido por Computador , Neoplasias Pulmonares/diagnóstico por imagen , Tomografía de Emisión de Positrones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
12.
Int J Radiat Oncol Biol Phys ; 105(3): 514-524, 2019 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-31306734

RESUMEN

PURPOSE: To benchmark and improve, through means of a targeted intervention, the quality of intensity modulated radiation therapy treatment planning for locally advanced head and neck cancer (HNC) in the Netherlands. The short and long-term impact of this intervention was assessed. METHODS AND MATERIALS: A delineated computed tomography-scan of an oropharynx HNC case was sent to all 15 Dutch radiation therapy centers treating HNC. Aims for planning target volume and organ-at-risk (OAR) dosimetry were established by consensus. Each center generated a treatment plan. In a targeted intervention, OAR sparing of all plans was discussed, and centers with the best OAR sparing shared their planning strategies. Impact of the intervention was assessed by (1) short-term (half a year after intervention) replanning of the original case and (2) long-term (1 and 3 years after intervention) planning of new cases. RESULTS: Benchmarking revealed substantial difference in OAR doses. Initial mean doses were 22 Gy (range, 15-31 Gy), 35 Gy (18-49 Gy), and 37 Gy (20-46 Gy) for the contralateral parotid gland, contralateral submandibular gland, and combined swallowing structures, respectively. Replanning after targeted intervention significantly reduced mean doses and variation, but clinically relevant differences still remained: 18 Gy (14-22 Gy), 28 Gy (17-45 Gy), and 29 Gy (18-39 Gy), respectively. One and 3 years later the variation remained stable. CONCLUSIONS: Despite many years of HNC intensity modulated radiation therapy experience, initial treatment plans showed surprisingly large variations. The simple targeted intervention used in this analysis improved OAR sparing, and its impact was durable; however, fairly large dose differences still continue to exist. Additional work is needed to understand these variations and to minimize them. A national radiation oncology platform can be instrumental for developing and maintaining high-quality planning protocols.


Asunto(s)
Benchmarking/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Tratamientos Conservadores del Órgano/métodos , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/normas , Benchmarking/normas , Encuestas de Atención de la Salud , Humanos , Países Bajos , Tratamientos Conservadores del Órgano/normas , Órganos en Riesgo/diagnóstico por imagen , Glándula Parótida/diagnóstico por imagen , Glándula Parótida/efectos de la radiación , Músculos Faríngeos/diagnóstico por imagen , Músculos Faríngeos/efectos de la radiación , Mejoramiento de la Calidad , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Glándula Submandibular/diagnóstico por imagen , Glándula Submandibular/efectos de la radiación , Factores de Tiempo , Lengua/diagnóstico por imagen , Lengua/efectos de la radiación , Neoplasias Tonsilares/diagnóstico por imagen , Neoplasias Tonsilares/radioterapia
13.
Clin Nucl Med ; 44(5): e323-e328, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30889002

RESUMEN

PURPOSE: Oropharynx cancer (OPC) is heterogeneous; human papillomavirus (HPV)-positive and HPV tumors represent 2 disease entities with a different prognosis. Earlier studies investigating the prognostic value of pretreatment F-FDG PET in OPC are small or included patients with unknown HPV status. This study assessed the prognostic value of PET variables, in a large cohort with balanced HPV status. METHODS: Retrospectively, primary tumor SUVmax, SUVpeak, metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were extracted from baseline FDG PET/CT of patients with OPC treated with (chemo)radiation. The Pearson correlation between the PET variables was calculated. With linear regression, the correlation between the PET variables and HPV status, age, smoking status, T stage, N stage, and American Joint Committee on Cancer stage was calculated. Univariable and multivariable Cox models analyzed local control, overall survival, and disease-free survival (DFS). RESULTS: Of 201 patients, 109 were HPV. Metabolic tumor volume and TLG correlated (r = 0.96), as did SUVpeak and SUVmax (r = 0.97). The PET variables correlated strongest with HPV status and T stage. These two accounted for 40% of the variance of MTV and 33% of TLG. Human papillomavirus-negative tumors had a significantly higher SUVmax, SUVpeak, MTV, and TLG. In univariable analysis, all PET variables were significantly associated with local control, overall survival, and DFS. In multivariable analysis, TLG was significantly associated to DFS in patients with HPV OPC (hazard ratio, 1.005; 95% confidence interval, 1.001-1.010; P = 0.03). However, we did not observe this in HPV patients. CONCLUSIONS: Increased baseline TLG is associated with worse DFS in HPV OPC and might be used as biomarker for risk stratification in these patients. Interestingly, we could not identify this association in HPV patients.


Asunto(s)
Neoplasias Orofaríngeas/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Orofaríngeas/patología , Neoplasias Orofaríngeas/virología , Infecciones por Papillomavirus/epidemiología , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Valor Predictivo de las Pruebas , Radiofármacos
14.
Phys Imaging Radiat Oncol ; 9: 65-68, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33458427

RESUMEN

Evaluation of salivary gland damage after head and neck radiotherapy (RT) is difficult with current tools, such as subjective patient-reported outcome measures. We demonstrate the use of prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT) as an objective non-invasive tool to visualize damage to salivary glands resulting from RT. In three clinical cases, the PSMA-ligand distribution correlates to the RT dose distribution including intra-gland dose gradients and matches patient-reported toxicity, suggesting a dose-response relation. These findings support further exploration of PSMA PET/CT to guide and evaluate RT, with the ultimate aim to reduce salivary gland toxicity.

15.
Artículo en Inglés | MEDLINE | ID: mdl-32095553

RESUMEN

INTRODUCTION: During a course of radiotherapy for head-and-neck-cancer (HNC), non-rigid anatomical changes can be observed on daily Cone Beam CT (CBCT). To objectify responses to these changes, we use a decision support system (traffic light protocol). Action levels orange and red may lead to re-planning. The purpose of this study was to evaluate how often re-planning was done for non-rigid anatomical changes, which anatomical changes led to re-planning and in which subgroups of patients treatment adaptation was deemed necessary. MATERIALS AND METHODS: A consecutive series of 388 HNC patients were retrospectively selected using the digital log of CBCT scans. The logs were analyzed for the number of new plans on an original planning CT scan (O-pCT) or a new pCT scan (N-pCT). Reasons for re-planning were categorized into: target volume increase/decrease, body contour decrease/increase and local shift of target volume. Subgroup analysis was performed to investigate relative differences of re-planning between treatment modalities. RESULTS: For 33 patients the treatment plan was adapted due to anatomical changes, resulting in 37 new plans in total. Re-planning on a N-pCT with complete re-delineation was done 22 times. In fifteen cases a new plan was created after adjustment of contours on the O-pCT. Main reasons for re-planning were target volume increase, body contour decrease and local shifts of target volume. Most re-planning (23%) was seen in patients treated with chemoradiotherapy. CONCLUSION: Visual detection of anatomical changes on CBCT during treatment of HNC, results in re-planning in 1 out of 10 patients.

16.
J Thorac Dis ; 10(Suppl 21): S2508-S2521, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30206495

RESUMEN

Advancements in functional imaging technology have allowed new possibilities in contouring of target volumes, monitoring therapy, and predicting treatment outcome in non-small cell lung cancer (NSCLC). Consequently, the role of 18F-fluorodeoxyglucose positron emission tomography (FDG PET) has expanded in the last decades from a stand-alone diagnostic tool to a versatile instrument integrated with computed tomography (CT), with a prominent role in lung cancer radiotherapy. This review outlines the most recent literature on developments in FDG PET imaging for prognostication and radiotherapy target volume delineation (TVD) in NSCLC. We also describe the challenges facing the clinical implementation of these developments and present new ideas for future research.

17.
Phys Imaging Radiat Oncol ; 5: 19-25, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33458364

RESUMEN

BACKGROUND AND PURPOSE: Local implementation of plan-specific quality assurance (QA) methods for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans may vary because of dissimilarities in procedures, equipment and software. The purpose of this work is detecting possible differences between local QA findings and those of an audit, using the same set of treatment plans. METHODS: A pre-defined set of clinical plans was devised and imported in the participating institute's treatment planning system for dose computation. The dose distribution was measured using an ionisation chamber, radiochromic film and an ionisation chamber array. The centres performed their own QA, which was compared to the audit findings. The agreement/disagreement between the audit and the institute QA results were assessed along with the differences between the dose distributions measured by the audit team and computed by the institute. RESULTS: For the majority of the cases the results of the audit were in agreement with the institute QA findings: ionisation chamber: 92%, array: 88%, film: 76% of the total measurements. In only a few of these cases the evaluated measurements failed for both: ionisation chamber: 2%, array: 4%, film: 0% of the total measurements. CONCLUSION: Using predefined treatment plans, we found that in approximately 80% of the evaluated measurements the results of local QA of IMRT and VMAT plans were in line with the findings of the audit. However, the percentage of agreement/disagreement depended on the characteristics of the measurement equipment used and on the analysis metric.

18.
J Appl Clin Med Phys ; 18(3): 5-8, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28504412

Asunto(s)
Física
19.
Phys Med Biol ; 61(19): 7221-7235, 2016 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-27649474

RESUMEN

In 2010, the NCS (Netherlands Commission on Radiation Dosimetry) installed a subcommittee to develop guidelines for quality assurance and control for volumetric modulated arc therapy (VMAT) treatments. The report (published in 2015) has been written by Dutch medical physicists and has therefore, inevitably, a Dutch focus. This paper is a condensed version of these guidelines, the full report in English is freely available from the NCS website www.radiationdosimetry.org. After describing the transition from IMRT to VMAT, the paper addresses machine quality assurance (QA) and treatment planning system (TPS) commissioning for VMAT. The final section discusses patient specific QA issues such as the use of class solutions, measurement devices and dose evaluation methods.


Asunto(s)
Algoritmos , Guías de Práctica Clínica como Asunto/normas , Garantía de la Calidad de Atención de Salud/normas , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/normas , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
20.
EJNMMI Phys ; 2(1): 4, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26501806

RESUMEN

BACKGROUND: In contemporary positron emission tomography (PET)/computed tomography (CT) scanners, PET attenuation correction is performed by means of a CT-based attenuation map. Respiratory motion can however induce offsets between the PET and CT data. Studies have demonstrated that these offsets can cause errors in quantitative PET measures. The purpose of this study is to quantify the effects of respiration-induced CT differences on the attenuation correction of pulmonary 18-fluordeoxyglucose (FDG) 3D PET/CT in a patient population and to investigate contributing factors. METHODS: For 32 lung cancer patients, 3D-CT, 4D-PET and 4D-CT data were acquired. The 4D FDG PET data were attenuation corrected (AC) using a free-breathing 3D-CT (3D-AC), the end-inspiration CT (EI-AC), the end-expiration CT (EE-AC) or phase-by-phase (P-AC). After reconstruction and AC, the 4D-PET data were averaged. In the 4Davg data, we measured maximum tumour standardised uptake value (SUV)max in the tumour, SUVmean in a lung volume of interest (VOI) and average SUV (SUVmean) in a muscle VOI. On the 4D-CT, we measured the lung volume differences and CT number changes between inhale and exhale in the lung VOI. RESULTS: Compared to P-AC, we found -2.3% (range -9.7% to 1.2%) lower tumour SUVmax in EI-AC and 2.0% (range -0.9% to 9.5%) higher SUVmax in EE-AC. No differences in the muscle SUV were found. The use of 3D-AC led to respiration-induced SUVmax differences up to 20% compared to the use of P-AC. SUVmean differences in the lung VOI between EI-AC and EE-AC correlated to average CT differences in this region (ρ = 0.83). SUVmax differences in the tumour correlated to the volume changes of the lungs (ρ = -0.55) and the motion amplitude of the tumour (ρ = 0.53), both as measured on the 4D-CT. CONCLUSIONS: Respiration-induced CT variations in clinical data can in extreme cases lead to SUV effects larger than 10% on PET attenuation correction. These differences were case specific and correlated to differences in CT number in the lungs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...