Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Gastrointest Endosc ; 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38604297

RESUMEN

BACKGROUND AND AIMS: This pilot study evaluated the performance of a recently developed computer-aided detection (CADe) system for Barrett's neoplasia during live endoscopic procedures. METHODS: Fifteen patients with a visible lesion and 15 without were included in this study. A CAD-assisted workflow was used that included a slow pullback video recording of the entire Barrett's segment with live CADe assistance, followed by CADe-assisted level-based video recordings every 2 cm of the Barrett's segment. Outcomes were per-patient and per-level diagnostic accuracy of the CAD-assisted workflow, in which the primary outcome was per-patient in vivo CADe sensitivity. RESULTS: In the per-patient analyses, the CADe system detected all visible lesions (sensitivity 100%). Per-patient CADe specificity was 53%. Per-level sensitivity and specificity of the CADe assisted workflow were 100% and 73%, respectively. CONCLUSIONS: In this pilot study, detection by the CADe system of all potentially neoplastic lesions in Barrett's esophagus was comparable to that of an expert endoscopist. Continued refinement of the system may improve specificity. External validation in larger multicenter studies is planned. (Clinical trial registration number: NCT05628441.).

2.
Gastrointest Endosc ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38636819

RESUMEN

BACKGROUND & AIMS: Characterization of visible abnormalities in Barrett esophagus (BE) patients can be challenging, especially for unexperienced endoscopists. This results in suboptimal diagnostic accuracy and poor inter-observer agreement. Computer-aided diagnosis (CADx) systems may assist endoscopists. We aimed to develop, validate and benchmark a CADx system for BE neoplasia. METHODS: The CADx system received pretraining with ImageNet with consecutive domain-specific pretraining with GastroNet which includes 5 million endoscopic images. It was subsequently trained and internally validated using 1,758 narrow-band imaging (NBI) images of early BE neoplasia (352 patients) and 1,838 NBI images of non-dysplastic BE (173 patients) from 8 international centers. CADx was tested prospectively on corresponding image and video test sets with 30 cases (20 patients) of BE neoplasia and 60 cases (31 patients) of non-dysplastic BE. The test set was benchmarked by 44 general endoscopists in two phases (phase 1: no CADx assistance; phase 2: with CADx assistance). Ten international BE experts provided additional benchmark performance. RESULTS: Stand-alone sensitivity and specificity of the CADx system were 100% and 98% for images and 93% and 96% for videos, respectively. CADx outperformed general endoscopists without CADx assistance in terms of sensitivity (p=0.04). Sensitivity and specificity of general endoscopist increased from 84% to 96% and 90 to 98% with CAD assistance (p<0.001), respectively. CADx assistance increased endoscopists' confidence in characterization (p<0.001). CADx performance was similar to Barrett experts. CONCLUSION: CADx assistance significantly increased characterization performance of BE neoplasia by general endoscopists to the level of expert endoscopists. The use of this CADx system may thereby improve daily Barrett surveillance.

3.
Cancers (Basel) ; 15(7)2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-37046611

RESUMEN

Optical biopsy in Barrett's oesophagus (BE) using endocytoscopy (EC) could optimize endoscopic screening. However, the identification of dysplasia is challenging due to the complex interpretation of the highly detailed images. Therefore, we assessed whether using artificial intelligence (AI) as second assessor could help gastroenterologists in interpreting endocytoscopic BE images. First, we prospectively videotaped 52 BE patients with EC. Then we trained and tested the AI pm distinct datasets drawn from 83,277 frames, developed an endocytoscopic BE classification system, and designed online training and testing modules. We invited two successive cohorts for these online modules: 10 endoscopists to validate the classification system and 12 gastroenterologists to evaluate AI as second assessor by providing six of them with the option to request AI assistance. Training the endoscopists in the classification system established an improved sensitivity of 90.0% (+32.67%, p < 0.001) and an accuracy of 77.67% (+13.0%, p = 0.020) compared with the baseline. However, these values deteriorated at follow-up (-16.67%, p < 0.001 and -8.0%, p = 0.009). Contrastingly, AI-assisted gastroenterologists maintained high sensitivity and accuracy at follow-up, subsequently outperforming the unassisted gastroenterologists (+20.0%, p = 0.025 and +12.22%, p = 0.05). Thus, best diagnostic scores for the identification of dysplasia emerged through human-machine collaboration between trained gastroenterologists with AI as the second assessor. Therefore, AI could support clinical implementation of optical biopsies through EC.

4.
United European Gastroenterol J ; 11(4): 324-336, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37095718

RESUMEN

INTRODUCTION: Endoscopic detection of early neoplasia in Barrett's esophagus is difficult. Computer Aided Detection (CADe) systems may assist in neoplasia detection. The aim of this study was to report the first steps in the development of a CADe system for Barrett's neoplasia and to evaluate its performance when compared with endoscopists. METHODS: This CADe system was developed by a consortium, consisting of the Amsterdam University Medical Center, Eindhoven University of Technology, and 15 international hospitals. After pretraining, the system was trained and validated using 1.713 neoplastic (564 patients) and 2.707 non-dysplastic Barrett's esophagus (NDBE; 665 patients) images. Neoplastic lesions were delineated by 14 experts. The performance of the CADe system was tested on three independent test sets. Test set 1 (50 neoplastic and 150 NDBE images) contained subtle neoplastic lesions representing challenging cases and was benchmarked by 52 general endoscopists. Test set 2 (50 neoplastic and 50 NDBE images) contained a heterogeneous case-mix of neoplastic lesions, representing distribution in clinical practice. Test set 3 (50 neoplastic and 150 NDBE images) contained prospectively collected imagery. The main outcome was correct classification of the images in terms of sensitivity. RESULTS: The sensitivity of the CADe system on test set 1 was 84%. For general endoscopists, sensitivity was 63%, corresponding to a neoplasia miss-rate of one-third of neoplastic lesions and a potential relative increase in neoplasia detection of 33% for CADe-assisted detection. The sensitivity of the CADe system on test sets 2 and 3 was 100% and 88%, respectively. The specificity of the CADe system varied for the three test sets between 64% and 66%. CONCLUSION: This study describes the first steps towards the establishment of an unprecedented data infrastructure for using machine learning to improve the endoscopic detection of Barrett's neoplasia. The CADe system detected neoplasia reliably and outperformed a large group of endoscopists in terms of sensitivity.


Asunto(s)
Esófago de Barrett , Aprendizaje Profundo , Neoplasias Esofágicas , Humanos , Esófago de Barrett/diagnóstico , Esófago de Barrett/patología , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/patología , Esofagoscopía/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...