Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Imaging ; 10(2)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38392085

RESUMEN

The validation of newly developed optical tissue-sensing techniques for tumor detection during cancer surgery requires an accurate correlation with the histological results. Additionally, such an accurate correlation facilitates precise data labeling for developing high-performance machine learning tissue-classification models. In this paper, a newly developed Point Projection Mapping system will be introduced, which allows non-destructive tracking of the measurement locations on tissue specimens. Additionally, a framework for accurate registration, validation, and labeling with the histopathology results is proposed and validated on a case study. The proposed framework provides a more-robust and accurate method for the tracking and validation of optical tissue-sensing techniques, which saves time and resources compared to the available conventional techniques.

2.
Front Oncol ; 13: 1209732, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37736547

RESUMEN

With the shift towards organ preserving treatment strategies in rectal cancer it has become increasingly important to accurately discriminate between a complete and good clinical response after neoadjuvant chemoradiotherapy (CRT). Standard of care imaging techniques such as CT and MRI are well equipped for initial staging of rectal tumors, but discrimination between a good clinical and complete response remains difficult due to their limited ability to detect small residual vital tumor fragments. To identify new promising imaging techniques that could fill this gap, it is crucial to know the size and invasion depth of residual vital tumor tissue since this determines the requirements with regard to the resolution and imaging depth of potential new optical imaging techniques. We analyzed 198 pathology slides from 30 rectal cancer patients with a Mandard tumor regression grade 2 or 3 after CRT that underwent surgery. For each patient we determined response pattern, size of the largest vital tumor fragment or bulk and the shortest distance from the vital tumor to the luminal surface. The response pattern was shrinkage in 14 patients and fragmentation in 16 patients. For both groups combined, the largest vital tumor fragment per patient was smaller than 1mm for 38% of patients, below 0.2mm for 12% of patients and for one patient as small as 0.06mm. For 29% of patients the vital tumor remnant was present within the first 0.01mm from the luminal surface and for 87% within 0.5mm. Our results explain why it is difficult to differentiate between a good clinical and complete response in rectal cancer patients using endoscopy and MRI, since in many patients submillimeter tumor fragments remain below the luminal surface. To detect residual vital tumor tissue in all patients included in this study a technique with a spatial resolution of 0.06mm and an imaging depth of 8.9mm would have been required. Optical imaging techniques offer the possibility of detecting majority of these cases due to the potential of both high-resolution imaging and enhanced contrast between tissue types. These techniques could thus serve as a complimentary tool to conventional methods for rectal cancer response assessment.

3.
Micromachines (Basel) ; 14(5)2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37241685

RESUMEN

In vivo tissue imaging is an essential tool for medical diagnosis, surgical guidance, and treatment. However, specular reflections caused by glossy tissue surfaces can significantly degrade image quality and hinder the accuracy of imaging systems. In this work, we further the miniaturisation of specular reflection reduction techniques using micro cameras, which have the potential to act as intra-operative supportive tools for clinicians. In order to remove these specular reflections, two small form factor camera probes, handheld at 10 mm footprint and miniaturisable to 2.3 mm, are developed using different modalities, with line-of-sight to further miniaturisation. (1) The sample is illuminated via multi-flash technique from four different positions, causing a shift in reflections which are then filtered out in a post-processing image reconstruction step. (2) The cross-polarisation technique integrates orthogonal polarisers onto the tip of the illumination fibres and camera, respectively, to filter out the polarisation maintaining reflections. These form part of a portable imaging system that is capable of rapid image acquisition using different illumination wavelengths, and employs techniques that lend themselves well to further footprint reduction. We demonstrate the efficacy of the proposed system with validating experiments on tissue-mimicking phantoms with high surface reflection, as well as on excised human breast tissue. We show that both methods can provide clear and detailed images of tissue structures along with the effective removal of distortion or artefacts caused by specular reflections. Our results suggest that the proposed system can improve the image quality of miniature in vivo tissue imaging systems and reveal underlying feature information at depth, for both human and machine observers, leading to better diagnosis and treatment outcomes.

4.
J Surg Res ; 283: 705-712, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36462380

RESUMEN

INTRODUCTION: Anastomotic leakage after gastrointestinal surgery has a high impact on patient's quality of life and its origin is associated with inadequate perfusion. Imaging photoplethysmography (iPPG) is a noninvasive imaging technique that measures blood-volume changes in the microvascular tissue bed and detects changes in tissue perfusion. MATERIALS AND METHODS: Intraoperative iPPG imaging was performed in 29 patients undergoing an open segment resection of the small intestine or colon. During each surgery, imaging was performed on fully perfused (true positives) and ischemic intestines (true negatives) and the anastomosis (unknowns). Imaging consisted of a 30-s video from which perfusion maps were extracted, providing detailed information about blood flow within the intestine microvasculature. To detect the predictive capabilities of iPPG, true positive and true negative perfusion conditions were used to develop two different perfusion classification methods. RESULTS: iPPG-derived perfusion parameters were highly correlated with perfusion-perfused or ischemic-in intestinal tissues. A perfusion confidence map distinguished perfused and ischemic intestinal tissues with 96% sensitivity and 86% specificity. Anastomosis images were scored as adequately perfused in 86% of cases and 14% inconclusive. The cubic-Support Vector Machine achieved 90.9% accuracy and an area under the curve of 96%. No anastomosis-related postoperative complications were encountered in this study. CONCLUSIONS: This study shows that noninvasive intraoperative iPPG is suitable for the objective assessment of small intestine and colon anastomotic perfusion. In addition, two perfusion classification methods were developed, providing the first step in an intestinal perfusion prediction model.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Fotopletismografía , Humanos , Fotopletismografía/efectos adversos , Calidad de Vida , Anastomosis Quirúrgica/efectos adversos , Procedimientos Quirúrgicos del Sistema Digestivo/efectos adversos , Fuga Anastomótica/etiología , Perfusión/efectos adversos , Verde de Indocianina
5.
J Imaging ; 8(4)2022 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-35448221

RESUMEN

Surgical excision is the golden standard for treatment of intestinal tumors. In this surgical procedure, inadequate perfusion of the anastomosis can lead to postoperative complications, such as anastomotic leakages. Imaging photoplethysmography (iPPG) can potentially provide objective and real-time feedback of the perfusion status of tissues. This feasibility study aims to evaluate an iPPG acquisition system during intestinal surgeries to detect the perfusion levels of the microvasculature tissue bed in different perfusion conditions. This feasibility study assesses three patients that underwent resection of a portion of the small intestine. Data was acquired from fully perfused, non-perfused and anastomosis parts of the intestine during different phases of the surgical procedure. Strategies for limiting motion and noise during acquisition were implemented. iPPG perfusion maps were successfully extracted from the intestine microvasculature, demonstrating that iPPG can be successfully used for detecting perturbations and perfusion changes in intestinal tissues during surgery. This study provides proof of concept for iPPG to detect changes in organ perfusion levels.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...