Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 144
Filtrar
1.
Eur J Heart Fail ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726573

RESUMEN

AIM: This analysis aimed to compare the clinical outcomes associated with heart failure (HF) readmissions and to identify associations with HF hospitalizations (HFH) in patients treated with the MitraClip™ NTR/XTR System in the EXPAND study. METHODS AND RESULTS: The global, real-world EXPAND study enrolled 1041 patients with primary or secondary mitral regurgitation (MR) treated with the MitraClip NTR/XTR System. Echocardiograms were analysed by an independent echocardiographic core laboratory. The study population was stratified into HFH and No-HFH groups based on the occurrence of HFH 1 year post-index procedure. Clinical outcomes including MR severity, New York Heart Association (NYHA) functional class, Kansas City Cardiomyopathy Questionnaire (KCCQ) score, and all-cause mortality were compared (HFH: n = 181; No-HFH: n = 860). Both groups achieved consistent 1-year MR reduction to ≤1+ (HFH vs. No-HFH: 87.3% vs. 89.5%, p = 0.6) and significant 1-year improvement in KCCQ scores (+16.5 vs. +22.3, p = 0.09) and NYHA functional class. However, more patients in the No-HFH group had 1-year NYHA class ≤II (HFH vs. No-HFH: 67.9% vs. 81.9%, p < 0.01). All-cause mortality at 1 year was 36.8% in the HFH group versus 10.4% in the No-HFH group (p < 0.001). The HFH rate decreased by 63% at 1 year post-M-TEER versus 1 year pre-treatment (relative risk 0.4, p < 0.001). Independent HFH associations were MR ≥2+ at discharge, HFH 1 year prior to treatment, baseline NYHA class ≥III, baseline tricuspid regurgitation ≥2+, and baseline left ventricular ejection fraction ≤40%. CONCLUSIONS: This study reports the impact of HFH on clinical outcomes post-treatment in the EXPAND study. Results demonstrate that the occurrence of HFH was associated with worse 1-year survival, and treatment with the MitraClip system substantially reduced HFH and improved patient symptoms and quality of life.

2.
Herz ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38743296

RESUMEN

BACKGROUND: Percutaneous valve therapies (PVT) are performed on a large number of patients. With increasing procedural volume, the need for follow-up has also increased. Follow-up in the heart valve clinic is endorsed by recent guidelines but utilization is unknown, making resource allocation in the clinic difficult. Central follow-up in valve centers may not be feasible for all patients in the future. METHODS: In our center, follow-up for PVT patients is scheduled at 1 month and 12 months after the index procedure. Patients are reminded of their appointment by invitation letters or phone calls. We analyzed 150 consecutive patients who underwent transcutaneous aortic valve implantation (TAVI) and MitraClip implantation (n = 300) at our center. RESULTS: At 1 month, 72.7% of patients attended their follow-up, while at 12 months the rate dropped to 58%. Patients who underwent TAVI were older than the MitraClip patients (82.7 vs. 76.1 years) but had lower mean logEuroSCORE (22.6% vs. 25.9%). There was no significant difference in 1­year mortality between TAVI and MitraClip patients (20% vs. 17.3%). By contrast, the rate of missed follow-up visits was higher for TAVI compared to MitraClip patients (52% vs. 33.3%; p = 0.002). Female patients less frequently attended follow-up (p = 0.005), whereas age, EuroSCORE, NYHA class, ejection fraction, and health status (EQ-5DVAS) were not predictors of attendance in multivariable analysis. Although the result of the EQ-5D assessment was not associated with mortality or attendance, completing the questionnaire was associated with overall survival (p < 0.001). CONCLUSION: In our heart valve clinic, we observed a high percentage of missed follow-up appointments (42% at 12 months) despite a structured follow-up plan. Factors significantly associated with non-attendance in multivariable analysis were female gender and having a TAVI rather than MitraClip. Future follow-up concepts should take such findings into account, and decentralized approaches need to be explored.

3.
Eur J Heart Fail ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654139

RESUMEN

AIMS: The safety and effectiveness of the MitraClip device to treat functional mitral regurgitation (FMR) has been tested in previous clinical trials yielding somewhat heterogeneous results in heart failure (HF) patients. Over time, the MitraClip device system has been modified and clinical practice evolved to consider also less severely diseased HF patients with FMR for this therapeutic option. The RESHAPE-HF2 trial aims to assess the safety and effectiveness of the MitraClip device system on top of medical therapy considered optimal in the treatment of clinically significant FMR in symptomatic patients with chronic HF. METHODS: The RESHAPE-HF2 is an investigator-initiated, prospective, randomized, parallel-controlled, multicentre trial designed to evaluate the use of the MitraClip device (used in the most up-to-date version as available at sites) plus optimal standard of care therapy (device group) compared to optimal standard of care therapy alone (control group). Eligible subjects have signs and symptoms of HF (New York Heart Association [NYHA] class II-IV despite optimal therapy), and have moderate-to-severe or severe FMR, as confirmed by a central echocardiography core laboratory; have an ejection fraction between ≥20% and ≤50% (initially 15-35% for NYHA class II patients, and 15-45% for NYHA class III/IV patients); have been adequately treated per applicable standards, and have received appropriate revascularization and cardiac resynchronization therapy, if eligible; had a HF hospitalization or elevated natriuretic peptides (B-type natriuretic peptide [BNP] ≥300 pg/ml or N-terminal proBNP ≥1000 pg/ml) in the last 90 days; and in whom isolated mitral valve surgery is not a recommended treatment option. The trial has three primary endpoints, which are these: (i) the composite rate of total (first and recurrent) HF hospitalizations and cardiovascular death during 24 months of follow-up, (ii) the rate of total (i.e. first and recurrent) HF hospitalizations within 24 months, and (iii) the change from baseline to 12 months in the Kansas City Cardiomyopathy Questionnaire overall score. The three primary endpoints will be analysed using the Hochberg procedure to control the familywise type I error rate across the three hypotheses. CONCLUSIONS: The RESHAPE-HF2 trial will provide sound evidence on the MitraClip device and its effects in HF patients with FMR. The recruitment was recently completed with 506 randomized patients.

4.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
5.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599692

RESUMEN

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
6.
ESC Heart Fail ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38602287

RESUMEN

AIMS: This study aims to assess the applicability of the mitral regurgitation (MR) proportionality concept in patients with atrial functional mitral regurgitation (aFMR) treated with transcatheter edge-to-edge repair (M-TEER). We hypothesized that patients with disproportionate MR (higher MR relative to left ventricular size) would exhibit different outcomes compared to those with proportionate MR, despite undergoing M-TEER. METHODS AND RESULTS: We retrospectively analysed 98 patients with aFMR from the EuroSMR registry who underwent M-TEER between 2008 and 2019. Patients met criteria for aFMR (normal indexed left ventricular end-diastolic volume [LVEDV], preserved left ventricular ejection fraction [LVEF] ≥ 50% without regional wall motion abnormalities, and structurally normal mitral valves). We excluded patients with missing effective regurgitant orifice area (EROA) or LVEDV data. The primary endpoint was 2-year mortality, with an EROA/LVEDV ratio employed to differentiate disproportionate from proportionate MR. Procedural success and baseline characteristics were analysed, and multivariate Cox proportional hazards models were used to identify mortality predictors. The mean patient age was 79 ± 7.3 years, with 68.8% female, and 79% had a history of atrial fibrillation. The mean EROA was 0.27 ± 0.14 cm2, and LVEDV was 95.6 ± 33.7 mL. Disproportionate MR was identified with an EROA/LVEDV ratio >0.339 cm2/100 mL. While procedural success was similar in both groups, disproportionate MR was associated with a numerically higher estimate of systolic pulmonary artery pressures (sPAP) and rates of NYHA ≥III and TR ≥ 3+. Disproportionate MR had a significant association with increased 2-year mortality (P < 0.001). The EROA/LVEDV ratio and tricuspid annular plane systolic excursion (TAPSE) were independent predictors of 2-year mortality (EROA/LVEDV: HR: 1.35, P = 0.010; TAPSE: HR: 0.85, P = 0.020). CONCLUSIONS: This analysis introduces the MR proportionality concept in aFMR patients and its potential prognostic value. Paradoxically, disproportionate MR in aFMR was linked to a 1.35-fold increase in 2-year mortality post-M-TEER, emphasizing the importance of accurate preprocedural FMR characterization. Our findings in patients with disproportionate MR indicate that a high degree of aFMR with high regurgitant volumes may lead to aggravated symptoms, which is a known contributor to increased mortality following M-TEER. These results underline the need for further research into the pathophysiology of aFMR to inform potential preventative and therapeutic strategies, ensuring optimal patient outcomes.

7.
Eur Heart J ; 45(11): 895-911, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38441886

RESUMEN

Atrial secondary tricuspid regurgitation (A-STR) is a distinct phenotype of secondary tricuspid regurgitation with predominant dilation of the right atrium and normal right and left ventricular function. Atrial secondary tricuspid regurgitation occurs most commonly in elderly women with atrial fibrillation and in heart failure with preserved ejection fraction in sinus rhythm. In A-STR, the main mechanism of leaflet malcoaptation is related to the presence of a significant dilation of the tricuspid annulus secondary to right atrial enlargement. In addition, there is an insufficient adaptive growth of tricuspid valve leaflets that become unable to cover the enlarged annular area. As opposed to the ventricular phenotype, in A-STR, the tricuspid valve leaflet tethering is typically trivial. The A-STR phenotype accounts for 10%-15% of clinically relevant tricuspid regurgitation and has better outcomes compared with the more prevalent ventricular phenotype. Recent data suggest that patients with A-STR may benefit from more aggressive rhythm control and timely valve interventions. However, little is mentioned in current guidelines on how to identify, evaluate, and manage these patients due to the lack of consistent evidence and variable definitions of this entity in recent investigations. This interdisciplinary expert opinion document focusing on A-STR is intended to help physicians understand this complex and rapidly evolving topic by reviewing its distinct pathophysiology, diagnosis, and multi-modality imaging characteristics. It first defines A-STR by proposing specific quantitative criteria for defining the atrial phenotype and for discriminating it from the ventricular phenotype, in order to facilitate standardization and consistency in research.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/complicaciones , Atrios Cardíacos/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia
8.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38437953

RESUMEN

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Ecocardiografía/métodos
9.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38458388

RESUMEN

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Estudios Retrospectivos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Anciano de 80 o más Años , Sistema de Registros , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Medios de Contraste/administración & dosificación , Estudios de Seguimiento
10.
Front Cardiovasc Med ; 11: 1223588, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38468721

RESUMEN

Background: There are different types of transcatheter mitral valve repair (TMVr) currently in clinical use, including leaflet approximation, annular cinching, and restoration of the chordal apparatus of the mitral valve (MV). While the concomitant combination (COMBO) therapy of mitral transcatheter edge-to-edge repair (M-TEER) with another TMVr concept has been proven feasible, potentially offering patient-tailored treatment for severe mitral regurgitation (MR), a comparison with M-TEER alone has not been made. Aims: To evaluate the procedural and clinical outcome of COMBO therapies compared with M-TEER alone. Methods: We included consecutive patients undergoing COMBO and M-TEER between March 2015 and April 2018 at our Heart Valve Center, while excluding patients presenting a case of redo or with previous MV surgery. Procedural outcomes and all-cause mortality were compared between COMBO therapy vs. M-TEER alone. Results: A total of 357 patients (mean age 78.9 ± 7.0 years, 53.2% male, M-TEER n = 322, COMBO n = 35; COMBO: MitraClip and the Carillon mitral contour system n = 26, MitraClip and Cardioband n = 5, and MitraClip and NeoChord n = 4) were analyzed. Patients with COMBO therapy had larger left chamber sizes, a lower left ventricular systolic ejection fraction (LVEF; COMBO: 37.4 ± 13.8%, M-TEER: 47.9 ± 14.3%, p < 0.001), and a more severe MR grade (p < 0.001). There were no significant differences in the prevalence of residual MR ≧2+. However, the need for re-intervention, always employing M-TEER, was more common in the COMBO group. During a mean 3.6-year long-term follow-up, there was no significant difference of all-cause mortality between both groups (Log rank p = 0.921). Conclusions: COMBO therapy may still be a beneficial therapy option for patients with severe MR who already have a more dilated left ventricle (LV), a more severe MR, and a more pronounced LV systolic dysfunction. The higher need for re-intervention in the COMBO group may signal more complex anatomies and possibly underlines the necessity of treating significant MR earlier. Future research is required to establish the COMBO approach as a toolbox-like treatment option, thus offering a patient-tailored approach depending on the individual anatomy and pathology.

11.
Eur Heart J ; 45(13): 1104-1115, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38366821

RESUMEN

Research performed in Europe has driven cardiovascular device innovation. This includes, but is not limited to, percutaneous coronary intervention, cardiac imaging, transcatheter heart valve implantation, and device therapy of cardiac arrhythmias and heart failure. An important part of future medical progress involves the evolution of medical technology and the ongoing development of artificial intelligence and machine learning. There is a need to foster an environment conducive to medical technology development and validation so that Europe can continue to play a major role in device innovation while providing high standards of safety. This paper summarizes viewpoints on the topic of device innovation in cardiovascular medicine at the European Society of Cardiology Cardiovascular Round Table, a strategic forum for high-level dialogue to discuss issues related to the future of cardiovascular health in Europe. Devices are developed and improved through an iterative process throughout their lifecycle. Early feasibility studies demonstrate proof of concept and help to optimize the design of a device. If successful, this should ideally be followed by randomized clinical trials comparing novel devices vs. accepted standards of care when available and the collection of post-market real-world evidence through registries. Unfortunately, standardized procedures for feasibility studies across various device categories have not yet been implemented in Europe. Cardiovascular imaging can be used to diagnose and characterize patients for interventions to improve procedural results and to monitor devices long term after implantation. Randomized clinical trials often use cardiac imaging-based inclusion criteria, while less frequently trials randomize patients to compare the diagnostic or prognostic value of different modalities. Applications using machine learning are increasingly important, but specific regulatory standards and pathways remain in development in both Europe and the USA. Standards are also needed for smart devices and digital technologies that support device-driven biomonitoring. Changes in device regulation introduced by the European Union aim to improve clinical evidence, transparency, and safety, but they may impact the speed of innovation, access, and availability. Device development programmes including dialogue on unmet needs and advice on study designs must be driven by a community of physicians, trialists, patients, regulators, payers, and industry to ensure that patients have access to innovative care.


Asunto(s)
Cardiología , Procedimientos Quirúrgicos Torácicos , Humanos , Inteligencia Artificial , Diagnóstico por Imagen , Técnicas de Imagen Cardíaca
12.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros
13.
ESC Heart Fail ; 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38351672

RESUMEN

AIMS: Achieving optimized guideline-directed medical therapy (GDMT) is recommended prior to transcatheter mitral valve edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). We aimed to propose and validate an easy-to-use score for assessing the quality of GDMT in patients with heart failure with reduced ejection fraction (HFrEF) undergoing M-TEER. METHODS AND RESULTS: Among the 1641 EuroSMR patients enrolled in the EuroSMR Registry who underwent M-TEER, a total of 1072 patients [median age 74, interquartile range (IQR) 67-79 years, 29% female] had complete data on GDMT and a left ventricular ejection fraction ≤ 40% and were included in the current study. We proposed a GDMT score that considers the dosage levels of three medication classes (angiotensin-converting enzyme inhibitors/angiotensin receptor blockers/angiotensin receptor-neprilysin inhibitors, beta-blockers, and mineralocorticoid receptor antagonists), with a maximum score of 12 points indicating optimal GDMT. The primary outcome was all-cause mortality. The median GDMT score was 4 points (IQR 3-6). All three domains of the scoring system were associated with all-cause mortality (P < 0.05 for all). The overall GDMT score was associated with all-cause mortality (hazard ratio 0.90, 95% confidence interval 0.86-0.95 for each 1-point increase in the GDMT score). This association remained significant after adjusting for renal function and co-morbidities. CONCLUSIONS: This study demonstrates the utility of a simple GDMT scoring system for assessing the adequacy of GDMT in HFrEF patients with relevant SMR undergoing M-TEER. The GDMT score has potential applications in guiding the design of future clinical trials and aiding clinical decision-making processes.

14.
Eur J Heart Fail ; 26(2): 483-501, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38269474

RESUMEN

Implantable devices form an integral part of the management of patients with heart failure (HF) and provide adjunctive therapies in addition to cornerstone drug treatment. Although the number of these devices is growing, only few are supported by robust evidence. Current devices aim to improve haemodynamics, improve reverse remodelling, or provide electrical therapy. A number of these devices have guideline recommendations and some have been shown to improve outcomes such as cardiac resynchronization therapy, implantable cardioverter-defibrillators and long-term mechanical support. For others, more evidence is still needed before large-scale implementation can be strongly advised. Of note, devices and drugs can work synergistically in HF as improved disease control with devices can allow for further optimization of drug therapy. Therefore, some devices might already be considered early in the disease trajectory of HF patients, while others might only be reserved for advanced HF. As such, device therapy should be integrated into HF care programmes. Unfortunately, implementation of devices, including those with the greatest evidence, in clinical care pathways is still suboptimal. This clinical consensus document of the Heart Failure Association (HFA) and European Heart Rhythm Association (EHRA) of the European Society of Cardiology (ESC) describes the physiological rationale behind device-provided therapy and also device-guided management, offers an overview of current implantable device options recommended by the guidelines and proposes a new integrated model of device therapy as a part of HF care.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
15.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
16.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
17.
Echocardiography ; 41(1): e15700, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37788169

RESUMEN

Minimalist approaches have evolved for TAVR over the last years with impact on in-hospital stay and patient safety. As part of this concept, transradial secondary arterial access is capable of reducing vascular and bleeding complications. Yet, steering of the marker pigtail catheter in the descending aorta might by fluoroscopic imaging sometimes be challenging. In our manuscript, we present a very simple "piggyback" technique, simplifying management of transradial secondary access in transfemoral TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Arteria Femoral/diagnóstico por imagen , Factores de Riesgo , Válvula Aórtica/cirugía
18.
J Am Coll Cardiol ; 83(1): 1-13, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-37898329

RESUMEN

BACKGROUND: In the TRILUMINATE Pivotal (Trial to Evaluate Cardiovascular Outcomes in Patients Treated with the Tricuspid Valve Repair System Pivotal), tricuspid transcatheter edge-to-edge repair (T-TEER) reduced tricuspid regurgitation (TR) and improved health status compared with medical therapy alone with no benefit on heart failure hospitalizations or survival. OBJECTIVES: The purpose of this study was to better understand the health status benefits of T-TEER within the TRILUMINATE Pivotal trial. METHODS: TRILUMINATE randomized patients with severe TR to T-TEER (n = 175) or medical therapy (n = 175). Health status was assessed at baseline and at 1, 6, and 12 months with the Kansas City Cardiomyopathy Questionnaire (KCCQ) (range 0-100; higher = better), which was compared between treatment groups using mixed effects linear regression. Alive and well was defined as KCCQ overall summary score ≥60 and no decline from baseline of >10 points at 1 year. RESULTS: Compared with medical therapy, T-TEER significantly improved health status at 1 month (mean between-group difference in KCCQ overall summary score 9.4 points; 95% CI: 5.3-13.4 points), with a small additional improvement at 1 year (mean between-group difference 10.4 points; 95% CI: 6.3-14.6 points). T-TEER patients were more likely to be alive and well at 1 year (T-TEER vs medical therapy: 74.8% vs 45.9%; P < 0.001), with a number needed to treat of 3.5. Interaction analyses demonstrated that the benefit of T-TEER diminished as baseline KCCQ overall summary score increased (Pint < 0.001). Exploratory analyses suggested that much of the health status benefit of T-TEER could be explained by TR reduction and that improvement in health status after T-TEER was strongly correlated with reduced 1-year mortality and heart failure hospitalization. CONCLUSIONS: T-TEER with the TriClip system resulted in substantial and sustained health status improvement in patients with severe TR compared with medical therapy alone.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estado de Salud , Válvula Tricúspide/cirugía , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/etiología , Cateterismo Cardíaco/métodos
19.
Eur J Heart Fail ; 26(1): 18-33, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38131233

RESUMEN

Right-sided heart failure and tricuspid regurgitation are common and strongly associated with poor quality of life and an increased risk of heart failure hospitalizations and death. While medical therapy for right-sided heart failure is limited, treatment options for tricuspid regurgitation include surgery and, based on recent developments, several transcatheter interventions. However, the patients who might benefit from tricuspid valve interventions are yet unknown, as is the ideal time for these treatments given the paucity of clinical evidence. In this context, it is crucial to elucidate aetiology and pathophysiological mechanisms leading to right-sided heart failure and tricuspid regurgitation in order to recognize when tricuspid regurgitation is a mere bystander and when it can cause or contribute to heart failure progression. Notably, early identification of right heart failure and tricuspid regurgitation may be crucial and optimal management requires knowledge about the different mechanisms and causes, clinical course and presentation, as well as possible treatment options. The aim of this clinical consensus statement is to summarize current knowledge about epidemiology, pathophysiology and treatment of tricuspid regurgitation in right-sided heart failure providing practical suggestions for patient identification and management.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/terapia , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Calidad de Vida , Válvula Tricúspide/cirugía , Resultado del Tratamiento
20.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38084735

RESUMEN

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...