1.
Bone Joint Res ; 9(6): 314-321, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32637075

RESUMEN

AIMS: Evaluate if treating an unstable femoral neck fracture with a locking plate and spring-loaded telescoping screw system would improve construct stability compared to gold standard treatment methods. METHODS: A 31B2 Pauwels' type III osteotomy with additional posterior wedge was cut into 30 fresh-frozen femur cadavers implanted with either: three cannulated screws in an inverted triangle configuration (CS), a sliding hip screw and anti-rotation screw (SHS), or a locking plate system with spring-loaded telescoping screws (LP). Dynamic cyclic compressive testing representative of walking with increasing weight-bearing was applied until failure was observed. Loss of fracture reduction was recorded using a high-resolution optical motion tracking system. RESULTS: LP constructs demonstrated the highest mean values for initial stiffness and failure load. LP and SHS constructs survived on mean over 50% more cycles and to loads 450 N higher than CS. During the early stages of cyclic loading, mean varus collapse of the femoral head was 0.5° (SD 0.8°) for LP, 0.7° (SD 0.7°) for SHS, and 1.9° (SD 2.3°) for CS (p = 0.071). At 30,000 cycles (1,050 N) mean femoral neck shortening was 1.8 mm (SD 1.9) for LP, 2.0 mm (SD 0.9) for SHS, and 3.2 mm (SD 2.5) for CS (p = 0.262). Mean leg shortening at construct failure was 4.9 mm (SD 2.7) for LP, 8.9 mm (SD 3.2) for SHS, and 7.0 mm (SD 4.3) for CS (p = 0.046). CONCLUSION: Use of the LP system provided similar (hip screw) or better (cannulated screws) biomechanical performance as the current gold standard methods suggesting that the LP system could be a promising alternative for the treatment of unstable fractures of the femoral neck.Cite this article: Bone Joint Res 2020;9(6):314-321.

2.
Arch Orthop Trauma Surg ; 140(12): 1955, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32462458

RESUMEN

The original version of this article unfortunately contained a mistake.

3.
Arch Orthop Trauma Surg ; 140(12): 1947-1954, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32270279

RESUMEN

INTRODUCTION: Aim of this study was to biomechanically compare two different acetabular cup fixation constructs in terms of fracture fixation for displaced acetabular fractures involving the anterior column with hemitransverse fracture under partial and full weight-bearing conditions. METHODS: Two different reinforcement rings designed as cages for primary THA were biomechanically tested in terms of managing a complex acetabular fracture. Single-leg stance cyclic loading was performed to assess fracture gap movement and fragment rotation. Twelve hemi pelvis Sawbones were divided into two groups: primary THA with acetabulum roof reinforcement plate (ARRP) (n = 6) and primary THA with Burch-Schneider reinforcement cage (BSRC) (n = 6). RESULTS: During loading under partial weight-bearing (250 N) fracture gap movement tended to be larger in the BSRC group as compared to the ARRP group. Under full weight-bearing conditions, the ARRP showed 60% significantly less motion (p = 0.035) of the os ilium to os ischii gap compared to BSRC. Fracture gap movements between the os ilium and spina iliaca fragments were significantly reduced by 76% (p = 0.048) for ARRP in contrast to BSRC. The ARRP group also demonstrated significantly less movement in the fracture gaps os ischii to quadrilateral plate (62% reduction, p = 0.009) and quadrilateral plate to spina iliaca (87% reduction, p < 0.001). Significantly less rotational movement of the quadrilateral plate to the os ilium was exhibited by the ARRP group (p = 0.015). CONCLUSIONS: The presented acetabulum roof-reinforcement plate (ARRP) provides stable conditions at the acetabular component with adequate stabilization of a displaced acetabular fracture.


Asunto(s)
Acetábulo , Artroplastia de Reemplazo de Cadera/instrumentación , Fenómenos Biomecánicos/fisiología , Placas Óseas/normas , Fracturas Óseas/cirugía , Fijadores Internos/normas , Ensayo de Materiales/métodos , Soporte de Peso/fisiología , Acetábulo/lesiones , Acetábulo/cirugía , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Investigación sobre la Eficacia Comparativa , Fractura-Luxación/cirugía , Humanos , Resultado del Tratamiento
4.
Unfallchirurg ; 121(10): 817-824, 2018 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-29464293

RESUMEN

INTRODUCTION: Kirschner wire osteosynthesis is considered to be the standard technique for surgical fixation of displaced supracondylar humeral and distal radial fractures in children. The Kirschner wires can be left exposed or buried under the skin. Advantages of the epicutaneous technique are, e. g. the efficiency (cost, effort) and the possibility for wire removal without the necessity of a second anesthesia. On the other hand, there is a concern about higher infection rates as well as traumatization of the children due to externally visible wires. METHODS: A web-based survey of members of the DGU, DGOU, DGOOC, and the pediatric traumatology section of the DGU (SKT) was performed to evaluate current treatment concepts in Germany. The pros and cons for each technique were recorded and the need for a clinical study was examined. In addition, a cost analysis was performed for both methods. The results from the literature are summarized and discussed. RESULTS: A total of 710 questionnaires were evaluated. The majority of the respondents were trauma surgeons working in a hospital (80%). The buried technique was superior in both fracture groups (supracondylar humeral fractures 73% and distal radius fractures 69%), whereas a relevant difference could be found depending on the profession. The main reason for the subcutaneous technique was anxiety or observed higher infections using the epicutaneous technique. CONCLUSION: In Germany, the majority of wires are buried under the skin due to a fear of higher infection rates. In addition, other influencing factors such as pain and traditional approaches play a significant role. With respect to the results in the literature as well as a possible improvement of efficiency and avoidance of a second anesthesia, a multicentric clinical study seems necessary in the future to compare both techniques.


Asunto(s)
Hilos Ortopédicos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas del Húmero/cirugía , Fracturas del Radio/cirugía , Niño , Remoción de Dispositivos , Alemania , Encuestas de Atención de la Salud , Humanos , Encuestas y Cuestionarios
5.
Unfallchirurg ; 121(3): 239-255, 2018 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-29464295

RESUMEN

Key factors for successful osteosynthetic fracture stabilization are anatomical fracture reduction, restoration of axis and torsion alignment as well as tissue-preserving operative techniques. In long bone fractures, the use of intramedullary long bridging nailing offers ideal conditions for bone healing, as axial and rotational stability is provided by canal-filling nails and locking screws. In addition, the tissue in the fracture region is protected as the intramedullary nail insertion is distant from the fracture. The indication spectrum for modern intramedullary locked nailing includes diaphyseal fractures of long bones, metaphyseal fractures and reconstructions, as well as treatment of nonunion, osteotomy and arthrodesis of the lower extremities. Continuous improvements in nail design and instrumentation as well as the introduction of anatomical reconstruction nails will optimize the spectrum and effectiveness of intramedullary osteosynthesis even further.


Asunto(s)
Fijación Intramedular de Fracturas/métodos , Fijación Intramedular de Fracturas/normas , Fracturas Óseas/cirugía , Curación de Fractura , Fracturas Óseas/complicaciones , Humanos
6.
Unfallchirurg ; 119(6): 517-26, 2016 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-27240851

RESUMEN

The so-called transitional fractures describe articular fractures in adolescents with partial closure of the epiphyseal growth plate. This shows a specific stereotype fracture pattern, which can be differentiated into biplane, triplane I and triplane II fractures depending on the involvement of the metaphysis and the number of fragments. The diagnostics and therapy can differ from fractures where the epiphyseal growth plate is still open. The main focus for surgical treatment is the reconstruction of the articular surface whereas relevant growth disturbances no longer need to be feared when the epiphysis has already begun to close.


Asunto(s)
Placa de Crecimiento/cirugía , Fracturas Intraarticulares/cirugía , Osteotomía/métodos , Procedimientos de Cirugía Plástica/métodos , Fracturas de Salter-Harris/cirugía , Medicina Basada en la Evidencia , Humanos , Fracturas Intraarticulares/diagnóstico , Osteotomía/instrumentación , Procedimientos de Cirugía Plástica/instrumentación , Fracturas de Salter-Harris/diagnóstico , Resultado del Tratamiento
7.
Z Orthop Unfall ; 153(3): 289-95, 2015 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-25959570

RESUMEN

BACKGROUND: The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. PATIENTS/MATERIAL AND METHODS: In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. RESULTS: In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed anterior-posterior screw fixation (1.03 ± 0.08 mm; p < 0.05). Assessment of the treatment outcome using the AFSS demonstrated a significantly higher score of 97.4 ± 6.4 in the group with a posterolateral approach compared to a score of 74.4 ± 12.1 (p < 0.05) in the group with an anterior-posterior screw fixation. CONCLUSION: In comparison to the anterior-posterior screw fixation, open reduction and fixation of the dislocated, posterolateral key fragment of the distal tibia using a posterolateral approach resulted in a more accurate fracture reduction and significantly better functional outcome 12 months after surgery. In addition, no increased rate of postoperative complications, or extended hospital stay was observed but there was less severe post-traumatic joint arthritis. The results of this study suggest that in complex ankle factures the open fixation of the dislocated posterolateral fragment is recommended as an alternative surgical procedure and may be beneficial for both clinical and radiological long-term outcomes.


Asunto(s)
Fracturas de Tobillo/cirugía , Articulación del Tobillo/cirugía , Fijación Interna de Fracturas/instrumentación , Fracturas Mal Unidas/cirugía , Luxaciones Articulares/cirugía , Tibia/cirugía , Fracturas de Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Tornillos Óseos , Femenino , Fijación Interna de Fracturas/métodos , Fracturas Mal Unidas/diagnóstico por imagen , Humanos , Luxaciones Articulares/diagnóstico por imagen , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Traumatismo Múltiple/diagnóstico por imagen , Traumatismo Múltiple/cirugía , Radiografía , Resultado del Tratamiento
8.
Unfallchirurg ; 118(4): 295-301, 2015 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-25676822

RESUMEN

BACKGROUND: Intramedullary nailing is the gold standard for the treatment of femoral shaft fractures; however, rotational malalignment remains a common complication. The patient can be positioned on the fracture table in a supine position or alternatively in the lateral decubitus position without any traction. OBJECTIVE: The aim of this article is to describe an effective method to control intraoperative torsion of the femur. METHOD: The surgical technique described in this article is the standard procedure for femoral shaft fractures and subtrochanteric fractures in this level 1 trauma center. The patient is positioned in a lateral position on a radiolucent table with free draping of the injured leg. Using the C-arm, reduction can be performed with this technique with precise placing of the nails and torsion can be exactly adjusted and controlled with the aid of the femoral neck axis, the distal locking holes and both parallel femoral condyles. RESULTS: The described technique represents an effective method for the intraoperative control of femoral torsion. With an acceptable and most probably clinically irrelevant bias, this technique is able to avoid significant rotational malalignment. It does not prolong the operative procedure and does not require additional navigation settings. It has also been shown to be helpful in the treatment of subtrochanteric fractures. CONCLUSION: The surgical technique of anterograde intramedullary nailing using the lateral decubitus position without any traction device and free draping of the injured leg represents a safe and reliable treatment concept and offers logistical advantages compared to the supine position of the patient on a fracture table. Together with other described methods of intraoperative torsional control of femoral fractures, the radiological technique described in this study is an easily applicable and safe method, which needs to be confirmed in clinical studies.


Asunto(s)
Clavos Ortopédicos , Tornillos Óseos , Fracturas del Fémur/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fijación Intramedular de Fracturas/métodos , Posicionamiento del Paciente/métodos , Placas Óseas , Fracturas del Fémur/diagnóstico , Humanos , Resultado del Tratamiento
9.
Unfallchirurg ; 118(8): 686-92, 2015 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-24402670

RESUMEN

BACKGROUND: For the treatment of proximal humeral fractures two major therapeutic principles can be employed: intramedullary nailing (PHN) or locking plate osteosynthesis. The aim of this study was to evaluate and compare clinical and radiological long-term outcome of proximal humeral fracture stabilization using PHN or angular stable plating. MATERIALS AND METHODS: In a retrospective study between March 2009 and March 2010, we analyzed 72 out of 118 patients with unified proximal humeral fracture who had been treated at least 3 years previously using PHN (44 patients) or angular stable plating (28 patients) in a level 1 trauma center. Functional and radiological outcomes were assessed at least 3 years after trauma using the Constant and Murley score and SF-36 score. RESULTS: According to the Neer classification, there were 31 3-part fractures (PHN: 23; plate: 8) and 41 4-part fractures (PHN: 21; plate: 20), respectively. No clinical symptoms after 3 years were observed in 42 patients, whereas in 30 patients clinical symptoms were evaluated related to pain and/or loss of function. Functional outcome using the Constant and Murley score demonstrated a total score of 73 points (ipsilateral side) vs. 88 points (contralateral side) in all evaluated patients, on average. CONCLUSION: Both PHN and angular stable plating are adequate treatment options for proximal humeral fractures. Both systems require precise preoperative planning and advanced surgical experience. No significant differences in long-term clinical and radiological outcome between implants regarding fracture classification, age of patient, and choice of implant were found.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fijación Intramedular de Fracturas/instrumentación , Fracturas del Hombro/diagnóstico , Fracturas del Hombro/cirugía , Dolor de Hombro/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/métodos , Curación de Fractura , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Fracturas del Hombro/complicaciones , Dolor de Hombro/diagnóstico , Dolor de Hombro/etiología , Resultado del Tratamiento
10.
Unfallchirurg ; 118(1): 35-41, 2015 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-24718730

RESUMEN

BACKGROUND: Displaced fractures of the acetabulum involving the quadrilateral plate continue to be a surgical challenge. In this study, we describe our operation technique of auxiliary acetabular cerclage-wiring combined with plate osteosynthesis and present our results as well as short-term outcome. PATIENTS AND METHODS: All patients aged 18 years and older treated with auxiliary cerclage-wiring between 2007 and 2012 were included in this study. Fractures were classified according to Letournel. Cerclage wiring was used when reposition and retention of the fracture was insufficient with plates and screws alone. Short-term outcome was evaluated by the German Short Musculoskeletal Functional Assessment (SMFA-D) questionnaire. RESULTS: Data from 23 patients were collected. The follow-up period was 7 months (range 2-23 months). Of the 23 patients, 22 showed excellent fracture reduction and retention. One patient had to undergo revision surgery due to loss of reposition. Patients showed good functional outcome. CONCLUSION: Auxiliary acetabular cerclage-wiring is a safe and effective method for fracture reduction and retention especially in displaced acetabular fractures involving the quadrilateral plate.


Asunto(s)
Acetábulo/lesiones , Acetábulo/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Fracturas Mal Unidas/cirugía , Acetábulo/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Placas Óseas , Tornillos Óseos , Hilos Ortopédicos , Terapia Combinada/instrumentación , Terapia Combinada/métodos , Femenino , Fracturas Óseas/diagnóstico por imagen , Fracturas Mal Unidas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento
11.
Z Orthop Unfall ; 150(3): 296-301, 2012 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-22328201

RESUMEN

In Germany 427,500 persons per year are injured in traffic accidents. So we analysed in a retrospective study the post-traumatic quality of life of patients suffering from a severe trauma (ISS ≥ 50). Highlights of interest were: (i) pattern of injury, (ii) injured part of the body, (iii) days in ICU, (iv) outcome, (v) actual state of health, (vi) mental health. Between 1/2000 and 12/2005, 1,435 patients with multiple trauma were hospitalised in the Trauma Center Murnau. 88 suffered from a severe trauma with ISS ≥ 50. 23 % of these patients had a good outcome and 36 % died. Actually, more than half of the patients were physically handicapped or suffered from pain. 41 % showed characteristics typical for a post-traumatic stress disorder. In conclusion the patients with severe trauma had a good survival rate, but they showed a poor post-traumatic quality of life. Thus, in the time after trauma it is important to treat the "whole patient" and not only the physical lesions.


Asunto(s)
Traumatismo Múltiple/mortalidad , Traumatismo Múltiple/terapia , Dolor/epidemiología , Calidad de Vida , Trastornos por Estrés Postraumático/epidemiología , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Análisis de Supervivencia , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA