Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Intervalo de año de publicación
1.
J Ophthalmol ; 2019: 7018937, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31885892

RESUMEN

Prospective, randomized, comparative, and controlled study to estimate the association between angle κ distance and higher-order aberrations (HOAs) with postoperative visual acuity after presbyopia-correcting IOL implantation. Forty-three eyes from 43 patients were included and randomly assigned in two groups for either AT LISA tri 839MP or Acrysof IQ PanOptix IOL implantation. The OPD-Scan III analyzer was utilized to assess the angle κ distance and higher-order aberration (HOAs). Twenty-three eyes were in the Acrysof IQ PanOptix group and 20 patients in the AT LISA tri 839MP group. The uncorrected distance visual acuity (UDVA) for the PanOptix group was 0.092 ± 0.10, whereas for AT LISA tri was 0.050 ± 0.06 (P=0.229). The uncorrected intermediate visual acuity (UIVA) for the PanOptix group was 0.173 ± 0.18, whereas for AT LISA tri, it was 0.182 ± 0.11 (P=0.669). Uncorrected near visual acuity (UNVA) was 0.068 ± 0.04 and 0.085 ± 0.07, respectively (P=0.221). Also, correlation coefficient between HOAs and the Strehl ratio for each group were -0.768 (P < 0.0001) and -0.863 (P=0.0001). Patients implanted with both trifocal IOLs showed excellent postoperative visual performance at all distances at the six-month follow-up visit. No association was found between angle κ distance and postoperative visual acuity regardless of the angle κ magnitude or the two trifocal IOLs inner optical diameter. Also, internal aberrations demonstrated a significant inverse correlation with the Strehl ratio for both trifocal IOLs.

2.
J AAPOS ; 22(2): 148-149, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29331455

RESUMEN

Pediatric cataract surgery poses a significant challenge for the cataract surgeon, in part because an elastic anterior capsule can make capsulorhexis difficult. With the use of femtosecond laser-assisted cataract surgery (FLACS), however, the continuous curvilinear capsulorhexis can be made with predictable size, circular shape, centration, and accuracy. In addition, topical anesthesia can be used for the FLACS docking procedure in cooperative children above 6 years of age, using transparent adhesive polyurethane film segments.


Asunto(s)
Capsulorrexis , Extracción de Catarata/métodos , Terapia por Láser/métodos , Implantación de Lentes Intraoculares , Anestesia Local/métodos , Anestésicos Locales/administración & dosificación , Niño , Humanos , Masculino , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Tetracaína/administración & dosificación , Agudeza Visual/fisiología
3.
Int Ophthalmol ; 38(3): 951-957, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28444525

RESUMEN

PURPOSE: To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. METHODS: This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. RESULTS: The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. CONCLUSION: The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.


Asunto(s)
Afaquia Poscatarata/diagnóstico , Biometría/métodos , Extracción de Catarata , Córnea/patología , Topografía de la Córnea/métodos , Lentes Intraoculares , Adolescente , Adulto , Afaquia Poscatarata/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Reproducibilidad de los Resultados , Adulto Joven
4.
J Refract Surg ; 28(4): 302-4, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22335205

RESUMEN

PURPOSE: To examine the stability and efficacy of high-cylinder power AcrySof toric intraocular lenses (IOLs), models SN60T6, SN60T7, SN60T8, and SN60T9 (Alcon Laboratories Inc). METHODS: Eligible eyes had cataract and symmetric corneal astigmatism > 2.25 diopters (D). Outcomes included monocular uncorrected distance visual acuity (UDVA), manifest refraction, and assessment of IOL axis. RESULTS: Nineteen eyes from 14 patients had preoperative corneal astigmatism of 4.00 ± 1.10 D. Postoperatively, residual refractive cylinder was 0.55 ± 0.60 D at 3 months. Uncorrected distance visual acuity was 1.3 ± 0.5 logMAR preoperatively and improved to 0.11 ± 0.09 logMAR 3 months postoperatively (P<.0001). All IOLs were stable within 5°. CONCLUSIONS: The IOLs were stable and effective in correcting high amounts of preexisting astigmatism at the time of cataract surgery.


Asunto(s)
Resinas Acrílicas , Astigmatismo/complicaciones , Catarata/complicaciones , Implantación de Lentes Intraoculares , Lentes Intraoculares , Astigmatismo/fisiopatología , Humanos , Proyectos Piloto , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Agudeza Visual/fisiología
5.
Case Rep Ophthalmol Med ; 2011: 594051, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22606468

RESUMEN

We examined a 39-year-old female with severe headache and blurred vision. She was on topiramate, 50 mg once a day for one week because of migraine. Periorbital edema, chemosis, myopia, high intraocular pressures, and shallow anterior chambers were present at the initial examination. Iridocorneal angles were closed, ultrasound showed choroidal effusions. We stopped topiramate and started antiglaucoma treatment. After one week the intraocular pressure was 10 mm Hg in both eyes without treatment. A new ultrasound showed no choroidal effusions. Topiramate has been associated with acute secondary angle closure glaucoma as an idiosyncratic reaction to the drug. Physicians prescribing topiramate need to alert patients of this potential sight-threatening idiosyncratic reaction.

6.
Clin Ophthalmol ; 3: 219-26, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19668569

RESUMEN

OBJECTIVE: To evaluate the effectiveness of prophylactic administration of nepafenac 0.1% in maintaining mydriasis and in preventing postoperative macular edema following cataract surgery. METHODS: This was a prospective, randomized, single-masked comparative study in 60 patients undergoing phacoemulsification cataract surgery. Patients were randomized to either the nepafenac or the control group. Nepafenac was administered 3 times daily 1 day before surgery and continued for 6 weeks. The control group received tobramycin-dexamethasone treatment only. Trans-operative mydriasis was measured before surgery, after nuclear emulsification, following cortex aspiration, and at the conclusion of surgery. Macular optical coherence tomography determined central foveal thickness (FT) and total macular volume (TMV) before surgery and at 2 and 6 weeks after surgery. All patients received tobramycin-dexamethasone for 2 weeks after surgery. RESULTS: The difference in mean pupil size, at the end of surgery, between the control group (6.84 +/- 0.93 mm) and the nepafenac group (7.91 +/- 0.74 mm) was statistically significant (p < 0.001). There were no significant differences in FT values between the two groups at any time point; however, TMV at 2 and at 6 weeks was statistically significantly different (p < 0.001), with higher TMV in the control group. CONCLUSION: Prophylactic use of nepafenac was effective in reducing macular edema after cataract surgery and in maintaining trans-operative mydriasis.

7.
Clin Ophthalmol ; 2(3): 657-60, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19668770

RESUMEN

We reported a 75-year-old diabetic man, who developed opacification and neovascularization of the posterior capsule after extracapsular cataract extraction and posterior chamber intraocular lens implantation. The patient was treated with two injections of 2.5 mg of intravitreal bevacizumab. The treatment produced an important regression of the posterior capsular new vessels, allowing us to perform a successful Nd:YAG capsulotomy, clearing the visual axis and improving the visualization of the posterior pole. Even though, best corrected visual acuity was 20/200 due to diabetic macular edema.

8.
Rev. mex. oftalmol ; 75(6): 204-206, nov.-dic. 2001. ilus
Artículo en Español | LILACS | ID: lil-326920

RESUMEN

Los corticoesteroides son comúnmente utilizados en el tratamiento de enfermedades inflamatorias oculares, ya que su concentración a nivel del segmento posterior del ojo es adecuada y se evitan los efectos colaterales de la administración sistémica. Sin embargo la técnica no es inocua y pueden presentarse complicaciones, como perforación del globo ocular con la subsecuente administración del medicamento en la cavidad vítrea o espacio subretiniano. En este artículo, los autores presentan el caso de un paciente en que ocurrió accidentalmente perforación ocular, su diagnóstico, evolución y manejo.


Asunto(s)
Humanos , Adulto , Femenino , Corticoesteroides , Cuerpo Vítreo/lesiones , Ojo , Heridas Punzantes , Inyecciones
9.
Rev. mex. oftalmol ; 74(4): 184-8, jul.-ago. 2000. ilus, CD-ROM
Artículo en Español | LILACS | ID: lil-295013

RESUMEN

Existen varios tipos de lesiones quísticas de la órbita, las cuales presentan características ecográficas comunes como forma redonda u oval, superficie bien delimitada de bordes definidos, y ausencia de vascularidad interna. Dichas lesiones son habitualmente fáciles de diferenciar de los tumores sólidos.


Asunto(s)
Quiste Dermoide/diagnóstico , Hidrocistoma/diagnóstico , Mucocele/diagnóstico , Enfermedades Orbitales/diagnóstico , Teratoma/diagnóstico , Órbita/patología , Ultrasonografía
10.
Rev. mex. oftalmol ; 74(2): 73-5, mar.-abr. 2000. tab, CD-ROM
Artículo en Español | LILACS | ID: lil-295069

RESUMEN

Los implantes secundarios de lentes intraoculares son importantes para pacientes en los que al realizar cirugía de catarata no se colocó un lente intraocular de primera intención, con la subsecuente dificultad para adaptarse a un lente de contacto y más aún cuando el ojo contralateral es fáquico o pseudofaco. Nosotros revisamos retrospectivamente expedientes del Hospital "Dr. Luis Sánchez Bulnes" de la Asociación Para Evitar la Ceguera, de pacientes que fueron sometidos a cirugía de implante secundario de lentes intraoculares de cámara anterior o posterior en un periodo entre 1989 y 1996, para valorar su capacidad visual final y conocer las posibles complicaciones que existen en estos pacientes. Se describe el tipo de cirugía inicial, el estado en que se encontraba el ojo en el momento del implante secundario, el número de pacientes que estaban rehabilitados visualmente y algunas otras variables clínico-epidemiológicas.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Catarata/terapia , Implantación de Lentes Intraoculares/métodos , Procedimientos Quirúrgicos Oftalmológicos/métodos
11.
Rev. mex. oftalmol ; 72(1): 22-5, ene.-feb. 1998. ilus
Artículo en Español | LILACS | ID: lil-252166

RESUMEN

La amiloidosis representa un espectro de alteraciones que afecta a órganos y sistemas; la fisiopatología involucra una vía metabólica común que resulta en un depósito de proteínas en los tejidos o en múltiple órganos y sistemas. Se presenta el caso de un paciente femenino con una masa blanda en reborde orbitario superior izquierdo, bien delimitada, móvil, con diagnóstico clínico de dacrioadenitis. Se inició tratamiento con prednisolona y sulfas en gotas y ungüento, además de antibiótico por vía oral, sin mostrar cambios en la evolución clínica. Se realizó estudio de ultrasonido ocular y orbitario AO con un equipo Biovisión B-scan-S, observando la presencia de una masa sólida, bien definida, localizada a la glándula lagrimal y con extensión a la porción superior de órbita izquierda. El modo A estandarizado reveló una estructura interna regular y alta reflectividad. El estudio histopatológico reportó una tinción positiva al Rojo Congo y birrefringencia a la luz polarizada con diagnóstico de amiloidosis de la glándula lagrimal. Aunque la amiloidosis de la glándula lagrimal es rara, el estudio de ultrasonido es un método útil en el diagnóstico, aun sin signos clínicos de amiloidosis


Asunto(s)
Humanos , Femenino , Adulto , Amiloidosis , Amiloidosis/patología , Biopsia , Aparato Lagrimal/patología
12.
Rev. mex. oftalmol ; 71(2): 64-6, mar.-abr. 1997. ilus
Artículo en Español | LILACS | ID: lil-227458

RESUMEN

En la actualidad una de las cirugías más populares para miopía alta es el procedimiento de Lasik, en la cual, la capa de Bowman es preservada. Nosotros estudiamos 9 ojos de 8 pacientes con ultrasonido biomicroscópico a quienes se les realizó la técnica de Lasik. Todos los pacientes fueron mayores de 20 años de edad, con un equivalente esférico promedio de -9.69 dioptrías. A la exploración con ultrasonido biomicroscópico las características de la córnea fueron similares tanto en el examen pre y postoperatorio, el grosor corneal promedio preoperatorio fue de 562 micras y en el post operatorio de 470 micras, la profundidad de la cámara anterior no presentó cambios significativos. La profundiad de la ablación promedio calculada en el preoperatorio fue de 90 micras y en post operatorio fue de 74 micras


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Cámara Anterior , Terapia por Láser , Epitelio Posterior , Miopía , Miopía/cirugía , Ultrasonografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...