Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur J Radiol ; 177: 111579, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38897053

RESUMEN

PURPOSE: Quantitative MRI techniques such as T2 mapping are useful in comprehensive evaluation of various pathologies of the knee joint yet require separate scans to conventional morphological measurements and long acquisition times. The recently introduced 3D MIXTURE (Multi-Interleaved X-prepared Turbo-Spin Echo with Intuitive Relaxometry) technique can obtain simultaneous morphologic and quantitative information of the knee joint. To compare MIXTURE with conventional methods and to identify differences in morphological and quantitative information. METHODS: Phantom studies were conducted, and in vivo human scans were performed (20 patients) presented with knee arthralgia. MIXTURE is based on 3D TSE without and with T2 preparation modules in an interleaved manner for both morphology with PDW and fat suppressed T2W imaging as well as quantitative T2 mapping within one single scan. Image quality and lesion depiction were visually assessed and compared between MIXTURE and conventional 2D TSE by two experienced radiologists. Contrast-to-noise ratio was used to assess the adjacent tissue contrast in a quantitative way for both obtained PDW and fat suppressed T2W images. Quantitative T2 values were measured in phantom and from in vivo knee cartilage. RESULTS: The overall diagnostic confidence and contrast-to-noise ratio were deemed comparable between MIXTURE and 2D TSE. While the chosen T2 preparation modules for MIXTURE rendered consistent T2 values comparing to the current standard, measured cartilage T2 values ranged from 26.1 to 50.7 ms, with significant difference between the lesion and normal areas (p < 0.05). CONCLUSIONS: MIXTURE can help to provide high-resolution information for both anatomical and pathological assessment.


Asunto(s)
Imagenología Tridimensional , Articulación de la Rodilla , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/patología , Adulto , Anciano , Interpretación de Imagen Asistida por Computador/métodos , Artralgia/diagnóstico por imagen , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados
2.
Diagnostics (Basel) ; 12(4)2022 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-35454062

RESUMEN

Unstable carotid plaques are visualized as high-signal plaques (HSPs) on 3D turbo spin-echo T1-weighted black-blood vessel wall imaging (3D TSE T1-BB VWI). The purpose of this study was to compare manual segmentation and semiautomated segmentation for the quantification of carotid HSPs using 3D TSE T1-BB VWI. Twenty cervical carotid plaque lesions in 19 patients with a plaque contrast ratio of > 1.3 compared to adjacent muscle were studied. Using the mean voxel value for the adjacent muscle multiplied by 1.3 as a threshold value, the semiautomated software exclusively segmented and measured the HSP volume. Manual and semiautomated HSP volumes were well correlated (r = 0.965). Regarding reproducibility, the inter-rater ICC was 0.959 (bias: 24.63, 95% limit of agreement: −96.07, 146.35) for the manual method and 0.998 (bias: 15.2, 95% limit of agreement: −17.83, 48.23) for the semiautomated method, indicating improved reproducibility by the semiautomated method compared to the manual method. The time required for semiautomated segmentation was significantly shorter than that of manual segmentation times (81.7 ± 7.8 s versus 189.5 ± 49.6 s; p < 0.01). The results obtained in this study demonstrate that the semiautomated segmentation method allows for reliable assessment of the HSP volume in patients with carotid plaque lesions, with reduced time and effort for the analysis.

3.
Curr Med Imaging ; 17(12): 1432-1438, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34365953

RESUMEN

OBJECTIVES: This study aimed to investigate the accuracy of conventional Sagittal Turbo spin Echo T2-weighted (Sag TSE-T2W), variable flip angle 3D TSE (VFA-3D-TSE) and high-resolution 3D heavily T2W (HR-3D-HT2W) sequences in the diagnosis of primary aqueductal stenosis (PAS) and Superior Medullary Velum Stenosis (SMV-S), and the effect of stenosis localization on diagnosis. METHODS: Seventy-seven patients were included in the study. The diagnosis accuracy of the HR-3D-HT2W, Sag TSE-T2W and VFA-3D-TSE sequences, was classified into three grades by two experienced neuroradiologists: grade 0 (the sequence has no diagnostic ability), grade 1 (the sequence diagnoses stenosis but does not show focal stenosis itself or membrane formation), and grade 2 (the sequence makes a definitive diagnosis of stenosis and shows focal stenosis itself or membrane formation). Stenosis localizations were divided into three as Cerebral Aquaduct (CA), Superior Medullary Velum (SMV) and SMV+CA. In the statistical analysis, the grades of the sequences were compared without making a differentiation based on localization. Then, the effect of localization on diagnosis was determined by comparing the grades for individual localizations. RESULTS: In the sequence comparison, grade 0 was not detected in the VFA-3D-TSE and HR-3DHT2W sequences, and these sequences diagnosed all cases. On the other hand, 25.4% of grade 0 was detected with the Sag TSE-T2W sequence (P<0.05). Grade 1 was detected by VFA-3D-TSE in 23% of the cases, while grade 1 (12.5%) was detected by HRH-3D-T2W in only one case, and the difference was statistically significant (P<0.05). When the sequences were examined according to localizations, the rate of grade 0 in the Sag TSE-T2W sequence was statistically significantly higher for the SMV localization (33.3%) compared to CA (66.7%) and SMV+CA (0%) (P<0.05). Localization had no effect on diagnosis using the other sequences. CONCLUSION: In our study, we found that the VFA-3D-TSE and HR-3D-HT2W sequences were successful in the diagnosis of PAS and SMV-S contrary to the Sag TSE-T2W sequence and especially SMV localization decreases the diagnostic accuracy of Sag TSE-T2W sequence.


Asunto(s)
Enfermedades Genéticas Ligadas al Cromosoma X , Hidrocefalia , Acueducto del Mesencéfalo , Constricción Patológica , Humanos , Imagen por Resonancia Magnética
4.
J Neuroradiol ; 47(5): 358-368, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32017974

RESUMEN

Post-contrast three-dimensional T1-weighted imaging of the brain is widely used for a broad range of vascular, inflammatory or tumoral diseases. The variable flip angle 3D TSE sequence is now available from several manufacturers (CUBE, General Electric; SPACE, Siemens; VISTA/BRAINVIEW, Philips; isoFSE, Itachi; 3D MVOX, Canon). Compared to gradient-echo (GRE) techniques, 3D TSE offers the advantages of useful image contrasts and reduction of artifacts from static field inhomogeneity. However, the respective role of 3D TSE and GRE MR sequences remains to be elucidated, particularly in the setting of post-contrast imaging. The purpose of this review was (1) to describe the technical aspects of 3D TSE sequences, (2) to illustrate the main clinical applications of the post-contrast 3D T1-w TSE sequence through clinical cases, (3) to discuss the respective role of post-contrast 3D TSE and GRE imaging in the field of neuroimaging.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Medios de Contraste , Humanos , Aumento de la Imagen/métodos
5.
Artículo en Japonés | MEDLINE | ID: mdl-31956185

RESUMEN

PURPOSE: In triggered acquisition noncontrast enhancement magnetic resonance angiography using ECG-gated with short-term inversion recovery (STIR-TRANCE), signal intensity and contrast fluctuate according to the value of refocus flip angle (RFA). We believe that we can visualize the pulmonary vascular excellently by optimized RFA which improves the signal intensity of pulmonary vascular and the contrast between pulmonary vascular and lung parenchyma. The purpose of this study is to optimize RFA in pulmonary vascular magnetic resonance angiography (MRA) imaging using STIR-TRANCE. METHOD: Pulmonary vascular MRA was performed in five normal volunteers. The department's ethics committee approved the study, and informed consent was obtained from all subjects. Before the STIR-TRANCE study, an ECG-gated single shot TSE (SS TSE) scan was performed to determine the timing of diastole. Later, the diastolic STIR-TRANCE imaging using both ECG and respiratory gating was performed with three different RFA (140 degree, 160 degree, and 180 degree). For physical evaluation, we used the signal to noise ratio (SNR) and contrast and for visual evaluation, so we used the Scheffe's method. RESULTS: SNR increases with increasing RFA. The contrast of 160 degree was significantly higher than the contrast of 180 degree. There was no significant difference in visual evaluation. CONCLUSION: From the perspective of specific absorption rate (SAR) reduction, we concluded that the optimal RFA for pulmonary vascular MRA in this study was 160 degree.


Asunto(s)
Electrocardiografía , Imagenología Tridimensional , Pulmón , Angiografía por Resonancia Magnética , Diástole , Humanos , Pulmón/irrigación sanguínea , Pulmón/diagnóstico por imagen , Relación Señal-Ruido
6.
J Magn Reson Imaging ; 51(6): 1727-1736, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31875343

RESUMEN

BACKGROUND: Muscle water T2 (T2w ) has been proposed as a biomarker to monitor disease activity and therapy effectiveness in patients with neuromuscular diseases (NMD). Multi-echo spin-echo (MESE) is known to be affected by fatty infiltration. A T2 -prepared 3D turbo spin echo (TSE) is an alternative method for T2 mapping, but has been only applied in healthy muscles. PURPOSE: To examine the performance of T2 -prepared 3D TSE in combination with spectral adiabatic inversion recovery (SPAIR) in measuring T2w in fatty infiltrated muscles based on simulations and in vivo measurements in thigh muscles of patients with NMD. STUDY TYPE: Prospective. SUBJECTS: One healthy volunteer, 34 NMD patients. FIELD STRENGTH/SEQUENCE: T2 -prepared stimulated echo acquisition mode (STEAM) magnetic resonance spectroscopy (MRS), SPAIR STEAM MRS, and SPAIR T2 -prepared STEAM MRS were performed in the subcutaneous fat of a healthy volunteer's thigh. T2 mapping based on SPAIR 2D MESE and SPAIR T2 -prepared 3D TSE was performed in the NMD patients' thigh region. Multi-TE STEAM MRS was performed for measuring a reference T2w at different thigh locations. ASSESSMENT: The behavior of the fat spectrum in the SPAIR T2 -prepared 3D TSE was simulated using Bloch simulations. The in vivo T2 results of the imaging methods were compared to the in vivo T2w MRS results. STATISTICAL TESTS: Pearson correlation coefficient with slope and intercept, relative error. RESULTS: The simulated T2 for the SPAIR T2 -prepared 3D TSE sequence remained constant within a relative error of not more than 4% up to a fat fraction of 80%. In vivo T2 values of SPAIR T2 -prepared 3D TSE were in good agreement with the T2w values of STEAM MRS (R = 0.86; slope = 1.12; intercept = -1.41 ms). In vivo T2 values of SPAIR 2D MESE showed large deviations from the T2w values of STEAM MRS (R = 0.14; slope = 0.32; intercept = 38.83 ms). DATA CONCLUSION: The proposed SPAIR T2 -prepared 3D TSE shows reduced sensitivity to fatty infiltration for T2w mapping in the thigh muscles of NMD patients. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1727-1736.


Asunto(s)
Enfermedades Neuromusculares , Muslo , Humanos , Imagen por Resonancia Magnética , Enfermedades Neuromusculares/diagnóstico por imagen , Estudios Prospectivos , Muslo/diagnóstico por imagen , Agua
7.
NMR Biomed ; 30(11)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28777496

RESUMEN

The purpose of this work was to investigate the performance of the modified BIR-4 T2 preparation for T2 mapping and propose a method to remove T2 quantification errors in the presence of large B1 and B0 offsets. The theoretical investigation of the magnetization evolution during the T2 preparation in the presence of B1 and B0 offsets showed deviations from a mono-exponential T2 decay (two parameter fit). A three parameter fit was used to improve T2 accuracy. Furthermore, a two parameter fit with an additional saturation preparation scan was proposed to improve T2 accuracy and precision. These three fitting methods were compared based on simulations, phantom measurements and an in vivo healthy volunteer study of the neck musculature using a 3D TSE readout. The results based upon the pure two parameter fit overestimated T2 in regions with high B0 offsets (up to 40% in phantoms). The three parameter fit T2 values were robust to B0 offsets but with higher standard deviation (up to 40% in simulations). The two parameter fit with the saturation preparation yielded high robustness towards B0 offsets with a noise performance comparable to that of the two parameter fit. In the volunteer study the T2 values obtained by the pure two parameter fit showed a dependence on the field inhomogeneities, whereas the T2 values from the proposed fitting approach were shown to be insensitive to B0 offsets. The proposed method enabled accurate and precise T2 mapping in the presence of large B1 and B0 offsets.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Adulto , Humanos , Fantasmas de Imagen
8.
J Magn Reson Imaging ; 46(3): 751-757, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28106936

RESUMEN

PURPOSE: To propose and evaluate a parameter tune-up solution to expedite a three-dimensional (3D) variable-flip-angle turbo spin-echo (TSE) sequence for whole-brain intracranial vessel wall (IVW) imaging. MATERIALS AND METHODS: Elliptical k-space sampling and prolonged echo train length (ETL), were used to expedite a 3D variable-flip-angle TSE-based sequence. To compensate for the potential loss in vessel wall signal, optimal combination of prescribed T2 and ETL was experimentally investigated on 22 healthy volunteers at 3 Tesla. The optimized protocol (7-8 min) was then compared with a previous protocol (reference protocol, 11-12 min) in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and wall delineation quality on a 4-point scale (0:poor; 3:excellent) in 10 healthy volunteers. A pilot study of five patients was performed and lesion delineation score was used to demonstrate the diagnostic quality. RESULTS: A protocol with ETL = 52 and prescribed T2 = 170 ms was deemed an optimized one, which, compared with the reference protocol, provided significantly improved wall SNR (12.0 ± 1.3 versus 10.0 ± 1.1; P = 0.002), wall-lumen CNR (9.7 ± 1.2 versus 8.0 ± 0.9; P = 0.002), wall-CSF CNR (2.8 ± 1.0 versus 1.7 ± 1.0; P = 0.026), similar vessel wall sharpness at both inner (1.59 ± 0.18 versus 1.58 ± 0.14, P = 0.87) and outer (1.71 ± 0.25 versus 1.83 ± 0.30; P = 0.18) boundaries, and comparable vessel wall delineation score for individual segments (1.95-3; P > 0.06). In all patients, atherosclerotic plaques (10) or wall dissection (5) were identified with a delineation score of 3 or 2. CONCLUSION: A parameter tune-up solution can accelerate 3D variable-flip-angle TSE acquisitions, particularly allowed for expedited whole-brain IVW imaging with preserved wall delineation quality. LEVEL OF EVIDENCE: 2. Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:751-757.


Asunto(s)
Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Relación Señal-Ruido
9.
Magn Reson Med ; 75(2): 729-38, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25753219

RESUMEN

PURPOSE: T2 -weighted imaging is of great diagnostic value in neuroimaging. Three-dimensional (3D) Cartesian turbo spin echo (TSE) scans provide high signal-to-noise ratio (SNR) and contiguous slice coverage. The purpose of this preliminary work is to implement a novel 3D spiral TSE technique with image quality comparable to 2D/3D Cartesian TSE. METHODS: The proposed technique uses multislab 3D TSE imaging. To mitigate the slice boundary artifacts, a sliding-slab method is extended to spiral imaging. A spiral-in/out readout is adopted to minimize the artifacts that may be present with the conventional spiral-out readout. Phase errors induced by B0 eddy currents are measured and compensated to allow for the combination of the spiral-in and spiral-out images. A nonuniform slice encoding scheme is used to reduce the truncation artifacts while preserving the SNR performance. RESULTS: Preliminary results show that each of the individual measures contributes to the overall performance, and the image quality of the results obtained with the proposed technique is, in general, comparable to that of 2D or 3D Cartesian TSE. CONCLUSION: 3D sliding-slab TSE with a spiral-in/out readout provides good-quality T2 -weighted images, and, therefore, may become a promising alternative to Cartesian TSE.


Asunto(s)
Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Artefactos , Voluntarios Sanos , Humanos , Relación Señal-Ruido
10.
Magn Reson Med ; 75(1): 266-73, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25754947

RESUMEN

PURPOSE: The three-dimensional (3D) spiral turbo spin echo (TSE) sequence is one of the preferred readout methods for arterial spin labeled (ASL) perfusion imaging. Conventional spiral TSE collects the data using a spiral-out readout on a stack of spirals trajectory. However, it may result in suboptimal image quality and is not flexible in protocol design. The goal of this study is to provide a more robust readout technique without such limitation. METHODS: The proposed technique incorporates a spiral-in/out readout into 3D TSE, and collects the data on a distributed spirals trajectory. The data set is split into the spiral-in and -out subsets that are reconstructed separately and combined after image deblurring. RESULTS: The volunteer results acquired with the proposed technique show no geometric distortion or signal pileup, as is present with GRASE, and no signal loss, as is seen with conventional spiral TSE. Examples also demonstrate the flexibility in changing the imaging parameters to satisfy various criteria. CONCLUSION: The 3D TSE with a distributed spiral-in/out trajectory provides a robust readout technique and allows for easy protocol design, thus is a promising alternative to GRASE or conventional spiral TSE for ASL perfusion imaging.


Asunto(s)
Algoritmos , Arterias Cerebrales/fisiología , Circulación Cerebrovascular , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Arterias Cerebrales/anatomía & histología , Humanos , Aumento de la Imagen/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
11.
J Magn Reson Imaging ; 39(4): 745-67, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24399498

RESUMEN

Spin-echo-based acquisitions are the workhorse of clinical MRI because they provide a variety of useful image contrasts and are resistant to image artifacts from radio-frequency or static field inhomogeneity. Three-dimensional (3D) acquisitions provide datasets that can be retrospectively reformatted for viewing in freely selectable orientations, and are thus advantageous for evaluating the complex anatomy associated with many clinical applications of MRI. Historically, however, 3D spin-echo-based acquisitions have not played a significant role in clinical MRI due to unacceptably long acquisition times or image artifacts associated with details of the acquisition method. Recently, optimized forms of 3D fast/turbo spin-echo imaging have become available from several MR-equipment manufacturers (for example, CUBE [GE], SPACE [Siemens], and VISTA [Philips]). Through specific design strategies and optimization, including short non-spatially selective radio-frequency pulses to significantly shorten the echo spacing and variable flip angles for the refocusing radio-frequency pulses to suppress blurring or considerably lengthen the useable duration of the spin-echo train, these techniques permit single-slab 3D imaging of sizeable volumes in clinically acceptable acquisition times. These optimized fast/turbo spin-echo pulse sequences provide a robust and flexible approach for 3D spin-echo-based imaging with a broad range of clinical applications.


Asunto(s)
Algoritmos , Artefactos , Imagen Eco-Planar/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Marcadores de Spin
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA