Biomed Phys Eng Express ; 10(5)2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39102840

RESUMEN

Background:Dispersion presents both a challenge and a diagnostic opportunity in shear wave elastography (SWE).Shear Wave Rheometry(SWR) is an inversion technique for processing SWE data acquired using an acoustic radiation force impulse (ARFI) excitation. The main advantage of SWR is that it can characterize the shear properties of homogeneous soft media over a wide frequency range. Assumptions associated with SWR include tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation).Objective:Evaluate the validity of the SWR assumptions in ex vivo bovine liver.Approach:SWR was used to measure the shear properties of bovine liver tissue as function of frequency over a large frequency range. Assumptions associated with SWR (tissue homogeneity, tissue isotropy, and axisymmetry of the ARFI excitation) were evaluated through measurements performed at multiple locations and probe orientations. Measurements focused on quantities that would reveal violations of the assumptions.Main results:Measurements of shear properties were obtained over the 25-250 Hz range, and showed a 4-fold increase in shear storage modulus (from 1 to 4 kPa) and over a 10-fold increase in the loss modulus (from 0.2 to 3 kPa) over that decade-wide frequency range. Measurements under different conditions were highly repeatable, and model error was low in all cases.Significance and Conclusion:SWR depends on modeling the ARFI-induced shear wave as a full vector viscoelastic shear wave resulting from an axisymmetric source; it is agnostic to any specific rheological model. Despite this generality, the model makes three main simplifying assumptions. These results show that the modeling assumptions used in SWR are valid in bovine liver over a wide frequency band.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hígado , Reología , Animales , Bovinos , Hígado/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Reología/métodos , Resistencia al Corte , Módulo de Elasticidad
2.
Clin Ter ; 175(3): 137-145, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38767070

RESUMEN

Background: Various non-invasive methods have been studied for assessing the fibrosis stage in patients with chronic hepatitis B. However, the performance of APGA, Fibrosis index in diagnosing liver fibrosis remains unclear globally and specifically in Vietnam. Methods: An analytical cross-sectional study was performed among 242 patients treated at Thong Nhat Hospital. Results: Both the APGA index and Fibrosis index showed good accuracy in diagnosing significant fibrosis (≥ F2), advanced liver fibro-sis (≥ F3), and cirrhosis (F4) with an area under the curve (AUROC) greater than 0.7. AUROC value of APGA index, Fibrosis index for diagnosing signifcant fibrosis (≥ F2) were 0.828, 0.767 respectively. AUROC value of APGA index, Fibrosis index for diagnosing advanced liver fibrosis (≥ F3) were 0.784, 0.755 respectively. AUROC value of APGA index, Fibrosis index for diagnosing cirrhosis (F4) were 0.736, 0.782 respectively. APGA index and the Fibrosis index were significantly positively correlated with the fibrosis stage (p < 0.001), with the APGA index showing the strongest correlation (r = 0.51, p < 0.001). Conclusions: The APGA values of 6.23, 7.88, and 8.99 can serve as cutoff points for the diagnosis of significant fibrosis (≥F2), advanced fibrosis (≥F3), and cirrhosis (F4) when combined with ARFI data.


Asunto(s)
Hepatitis B Crónica , Cirrosis Hepática , Humanos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/patología , Estudios Transversales , Hepatitis B Crónica/complicaciones , Hepatitis B Crónica/patología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Vietnam
3.
Abdom Radiol (NY) ; 49(9): 3088-3095, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38652124

RESUMEN

PURPOSE: Liver stiffness measurement (LSM) by transient elastography has been shown to underperform in high-risk varices (HRVs) prediction in obese non-alcoholic fatty liver disease (NAFLD) compensated cirrhosis (CC). LSM by magnetic resonance elastography (MRE) and acoustic force radiation impulse (ARFI) has been shown to be useful in prediction of oesophageal varices (EVs), but has limited evidence in obese NAFLD-CC. METHODS: Obese patients with NAFLD-CC who underwent MRE and ARFI for LSM and endoscopy for screening of varices were enrolled. Performance of MRE and ARFI for predicting EVs or HRVs was evaluated using area under receiver operating characteristics (AUROC) curves and regression analyses were performed for predictor variables. RESULTS: One hundred eight patients [mean age 54.7 ± 9.6 years, median BMI, 28.5 (26.4-30.0) kg/m2. 72.2% diabetics, 45.4% hypertensive] were enrolled. Fifty-two (48.1%) had no varices, while 29 (26.8%) and 27 (25%) had low-risk varices (LRVs) and HRVs, respectively. MRE-LSM was higher in patients with LRVs (p = 0.01) or HRVs (p = 0.001) against those without varices. ARFI-LSM did not differ significantly between those without and with LRVs or HRVs (p > 0.05 for all). There was a low correlation between ARFI-LSM and MRE-LSM in the overall cohort (r = 0.19). Only platelet count (PC) [0.98 (0.97-0.99)] and MRE-LSM [1.8 (1.26-2.79)] were predictors of HRVs. At a cut-off of 4.75, MRE showed a sensitivity of 96.3%. Model combining MRE-LSM with PC had a diagnostic AUROC of 0.77 and 0.76 for EVs and HRVs. CONCLUSION: In obese NAFLD-CC, MRE-LSM is significantly higher in patients with varices. MRE combined with PC predicts EVs and HRVs with better accuracy than ARFI.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Várices Esofágicas y Gástricas , Cirrosis Hepática , Enfermedad del Hígado Graso no Alcohólico , Obesidad , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Persona de Mediana Edad , Masculino , Várices Esofágicas y Gástricas/diagnóstico por imagen , Várices Esofágicas y Gástricas/etiología , Femenino , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/complicaciones , Obesidad/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/complicaciones , Valor Predictivo de las Pruebas , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
4.
Diagnostics (Basel) ; 14(7)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38611598

RESUMEN

Acoustic radiation forced impulse (ARFI) is an integrated ultrasound method, measuring stiffness by point shear wave elastography. To evaluate the diagnostic performance of the ARFI of the liver and the spleen, combined with spleen dimension and platelet count, in predicting high-risk esophageal varices (HRVs) in cirrhotic patients, a prospective and cross-sectional study was conducted between February 2017 and February 2021. The following ratio scores were calculated based on ARFI measurements: ALSDP (ARFI Liver-Spleen Diameter-to-Platelet Ratio Score), ASSDP (ARFI Spleen-Spleen Diameter-to-Platelet Ratio Score), ASSAP (ARFI Spleen-Spleen Area-to-Platelet Ratio Score), and ALSAP (ARFI Liver-Spleen Area-to-Platelet Ratio Score). In 100 enrolled subjects, spleen ARFI, ASSDP, and ASSAP were significantly associated with HRVs in the prospective short- and long-term follow-ups and in the cross-sectional study (p < 0.05), while ALSDP and ALSAP were associated with HRVs only in the prospective long-term follow-up and cross-sectional study (p< 0.05). ASSAP was the best ARFI ratio score for HRVs at the long-term follow-up [value of area under curve (AUC) = 0.88], although all the ARFI ratio scores performed better than individual liver and spleen ARFI (AUC > 0.7). In our study, ARFI ratio scores can predict, in well-compensated cirrhotic patients, the risk of developing HVRs in short- and long-term periods.

5.
BMC Med Imaging ; 24(1): 90, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627672

RESUMEN

BACKGROUND: Wilson's disease (WD) often leads to liver fibrosis and cirrhosis, and early diagnosis of WD cirrhosis is essential. Currently, there are few non-invasive prediction models for WD cirrhosis. The purpose of this study is to non-invasively predict the occurrence risk of compensated WD cirrhosis based on ultrasound imaging features and clinical characteristics. METHODS: A retrospective analysis of the clinical characteristics and ultrasound examination data of 102 WD patients from November 2018 to November 2020 was conducted. According to the staging system for WD liver involvement, the patients were divided into a cirrhosis group (n = 43) and a non-cirrhosis group (n = 59). Multivariable logistic regression analysis was used to identify independent influencing factors for WD cirrhosis. A nomogram for predicting WD cirrhosis was constructed using R analysis software, and validation of the model's discrimination, calibration, and clinical applicability was completed. Due to the low incidence of WD and the small sample size, bootstrap internal sampling with 500 iterations was adopted for validation to prevent overfitting of the model. RESULTS: Acoustic Radiation Force Impulse (ARFI), portal vein diameter (PVD), and serum albumin (ALB) are independent factors affecting WD cirrhosis. A nomogram for WD cirrhosis was constructed based on these factors. The area under the ROC curve (AUC) of the model's predictive ability is 0.927 (95% CI: 0.88-0.978). As demonstrated by 500 Bootstrap internal sampling validations, the model has high discrimination and calibration. Clinical decision curve analysis shows that the model has high clinical practical value. ROC curve analysis of the model's rationality indicates that the model's AUC is greater than the AUC of using ALB, ARFI, and PVD alone. CONCLUSION: The nomogram model constructed based on ARFI, PVD, and ALB can serve as a non-invasive tool to effectively predict the risk of developing WD cirrhosis.


Asunto(s)
Degeneración Hepatolenticular , Humanos , Degeneración Hepatolenticular/diagnóstico por imagen , Degeneración Hepatolenticular/complicaciones , Nomogramas , Estudios Retrospectivos , Cirrosis Hepática/diagnóstico por imagen , Curva ROC
6.
Orphanet J Rare Dis ; 19(1): 6, 2024 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172891

RESUMEN

BACKGROUND: Extracorporeal shock wave therapy (ESWT) is reportedly effective for improving spasticity and motor function in children with cerebral palsy (CP). Because late-stage Rett syndrome has a similar presentation, this study aimed to investigate the effects of ESWT on these two diseases. MATERIAL AND METHODS: Patients diagnosed with spastic CP and Rett syndrome received 1500 impulses of ESWT at 4 Hz and 0.1 mJ/mm2, on their spastic legsonce weekly for a total of 12 weeks. Outcomes were assessed before and 4 and 12 weeks after ESWT. Clinical assessments included the Modified Ashworth Scale (MAS), passive range of motion (PROM), and Gross Motor Function Measure 88 (GMFM-88). Ultrasonographic assessments included muscle thickness, acoustic radiation force impulse (ARFI), and strain elastography. RESULTS: Fifteen patients with CP and six with Rett syndrome were enrolled in this study. After ESWT, patients with CP showed significant clinical improvement in the MAS (P = 0.011), ankle PROM (P = 0.002), walking/running/jumping function (P = 0.003), and total function (P < 0.001) of the GMFM-88. The patients with Rett syndrome showed improved MAS scores (P = 0.061) and significantly improved total gross motor function (P = 0.030). Under ARFI, patients with CP demonstrated decreased shear wave speed in the gastrocnemius medial head (P = 0.038). Conversely, patients with Rett syndrome show increased shear-wave speeds after ESWT. CONCLUSION: Our study provides evidence that a weekly course of low-dose ESWT for 12 weeks is beneficial for children with both CP and Rett syndrome, with the clinical effects of reducing spasticity and improving the gross motor function of the lower limbs. The ARFI sonoelastography reveals improvement of muscle stiffness in patients with CP after ESWT, but deteriorated in patients with Rett syndrome. The diverse therapeutic response to ESWT may be caused by the MECP2 mutation in Rett syndrome, having a continuous impact and driving the pathophysiology differently as compared to CP, which is secondary to a static insult. Trial registration IRB 201700462A3. Registered 22March 2017, https://cghhrpms.cgmh.org.tw/HRPMS/Default.aspx .


Asunto(s)
Parálisis Cerebral , Tratamiento con Ondas de Choque Extracorpóreas , Síndrome de Rett , Niño , Humanos , Espasticidad Muscular/terapia , Síndrome de Rett/diagnóstico por imagen , Síndrome de Rett/terapia , Parálisis Cerebral/diagnóstico por imagen , Parálisis Cerebral/terapia , Parálisis Cerebral/complicaciones , Tratamiento con Ondas de Choque Extracorpóreas/efectos adversos , Músculo Esquelético
7.
J Ultrasound ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38227146

RESUMEN

AIMS: To assess the liver stiffness in patients with rheumatoid arthritis treated with methotrexate monotherapy using non-invasive, ultrasound-based elastography (acoustic radiation force impulse (ARFI) imaging) in a longitudinal approach. METHODS: In total, 23 MTX-naive patients were longitudinally assessed using acoustic radiation force impulse (ARFI) imaging. Baseline assessments were carried out between July 2018 and April 2019, and the follow-up evaluations took place after an average of 2.6 years. The main outcome variable was the mean shear wave velocity as measured by the ARFI method. It was calculated from 10 valid ARFI measurements for each patient. Inferential statistical analyses (within-group comparisons) were performed using t-tests for dependent samples or suitable nonparametric procedures. RESULTS: The main finding was that observed ARFI shear wave velocities did not increase during the observation period. In fact, this parameter decreased over time from 1.07 m/s (SD = 0.23) at baseline without MTX exposure to 0.97 m/s (SD = 0.16) at follow-up after a mean of 2.6 years (P = 0.013). Moreover, the magnitude of the change in shear wave velocity could not be predicted by indicators of inflammation or disease activity, BMI, age, sex or NSAR intake (corresponding regression analysis: corrected R2 = 0.344; P = 0.296). CONCLUSIONS: No increased risk of liver fibrosis was found in RA patients treated with MTX monotherapy during observation period.

8.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1018422

RESUMEN

Objective To assess the clinical effect of the Yiqi Huoxue Huazhuo therapy(the therapy for replenishing qi,activating blood and resolving turbidity)for the treatment of hepatic fibrosis in Wilson's disease(WD,also known as hepatolenticular degeneration).Methods Using retrospective research method,52 patients with liver fibrosis in WD of qi deficiency and blood stasis type were divided into 24 cases in the control group and 28 cases in the treatment group according to the treatment method.The control group was treated with conventional decopper therapy with western medicines,and the treatment group was treated with Chinese herbal decoction based on Yiqi Huoxue Huazhuo therapy together with conventional decopper therapy.Both groups were treated for a total of 4 weeks.Before and after the treatment,the two groups were observed in the changes of traditional Chinese medicine(TCM)syndrome scores,Unified Wilson's Disease Rating Scale(UWDRS)hepatic symptom scores,serum levels of liver fibrosis indicators of pre-collagen typeⅢ(PCⅢ),hyaluronic acid(HA),collagenⅣ(CⅣ),and laminin(LN),C-X-C motif chemokine ligand 10(CXCL10)level,and the point shear-wave elastography(pSWE)values of hepatic ultrasound based on acoustic radiation force impulse imaging(ARFI).After treatment,the clinical efficacy of the two groups was evaluated.Results(1)After 4 weeks of treatment,the total effective rate of the treatment group was 85.71%(24/28),while that of the control group was 54.17%(13/24),and the intergroup comparison(tested by chi-square test)showed that the therapeutic efficacy of the treatment group was significantly superior to that of the control group(P<0.05).(2)After treatment,the TCM syndrome scores in both groups were decreased compared with those before treatment(P<0.01),and the decrease of TCM syndrome scores in the treatment group was significantly superior to that in the control group(P<0.05).(3)After treatment,the UWDRS liver symptom scores in the two groups were decreased compared with those before treatment(P<0.01),but the difference was not statistically significant when comparing between the two groups after treatment(P>0.05).(4)After treatment,serum levels of liver fibrosis indicators of HA,LN,CⅣ and PCⅢ in the treatment group were all decreased compared with those before treatment(P<0.01),while in the control group only serum LN and PCⅢlevels were decreased(P<0.05).The intergroup comparison showed that the decrease of serum HA,LN,and PCⅢlevels in the treatment group was superior to that in the control group(P<0.05 or P<0.01),while the decrease of serum CⅣlevel tended to be superior to that in the control group,but the difference was not statistically significant(P>0.05).(5)After treatment,the serum chemokine CXCL10 level in the treatment group was significantly decreased compared with that before treatment(P<0.01),while the level tended to decrease in the control group,but the difference was not statistically significant(P>0.05).The intergroup comparison showed that the reduction of serum CXCL10 level in the treatment group was significantly superior to that in the control group(P<0.05).(6)After treatment,the pSWE values of hepatic ultrasound in the two groups were lower than those before treatment(P<0.01),and the reduction of pSWE values in treatment group was significantly superior to that of the control group(P<0.01).Conclusion Yiqi Huoxue Huazhuo therapy can effectively reduce the TCM syndrome scores of WD patients,improve the UWDRS hepatic symptom scores,down-regulate the liver fibrosis indicator level and serum CXCL10 expression level,reduce the pSWE values of hepatic ultrasound,and enhance the clinical efficacy.

9.
G Ital Nefrol ; 40(4)2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37910216

RESUMEN

Introduction. Acoustic Radiation Force Impulse (ARFI) is an ultrasound parameter which has shown promise in assessing liver stiffness, but there are limited data on the correlation of ARFI with chronicity markers in renal biopsies. Objectives. Determine ARFI values in ultrasound and correlate with chronicity markers in renal biopsy. Determine whether ARFI can be used as a non-invasive chronicity predictor compared to renal length, Resistive Index (RI), and cortical thickness. Patients and Methods. Two hundred and fifty patients were enrolled in the study. The ultrasound variables ARFI, renal length, RI, and cortical thickness values were assessed by the radiologist prior to renal biopsy. The biopsy slides were graded as per the Mayo Clinic consensus report scoring system by an experienced pathologist. Results. Among 250 study participants, 167 were males and 83 were females. IgA nephropathy was the most common pathology (n=47;19%), followed by diabetic nephropathy (n=42;17%), membranous nephropathy (n=35;14%), FSGS (n=27;11%), and MCD (n=19; 8%). The mean eGFR was 55.9 ± 42.12 ml/min/1.73 m2. The average renal length was 10.086 ± 1.01 cm. The average cortical thickness was 0.707 ± 0.134 cm. Resistive index was 0.68 ± 0.09. Acoustic radiation force impulse had weak negative correlation (r=-0.286; p=0.0001) with total pathological score and weak positive correlation with eGFR (r=0.279; p=0.0001). RI was a better indicator for histologically evaluated chronicity with positive correlation coefficient (r=0.416; p=0.0005) compared to renal length, cortical thickness, and ARFI. Conclusion. ARFI didn't corelate with the pathological score in renal biopsies. RI had better predictive value for chronicity in native renal biopsies.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Glomerulonefritis por IGA , Glomerulonefritis Membranosa , Masculino , Femenino , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Riñón/diagnóstico por imagen , Riñón/patología , Biopsia
10.
Artículo en Inglés | MEDLINE | ID: mdl-37930496

RESUMEN

BACKGROUND: In routine clinical practice, assessment of portal hypertension (PHT) among patients with liver cirrhosis is done by a upper gastrointestinal endoscopy (UGIE); however, its invasive nature limits its use. Recent advances in ultrasound imaging make it possible to evaluate the tissue stiffness of the liver and spleen reflecting the severity of underlying fibrosis. Liver stiffness and spleen stiffness can be used to predict the presence of esophageal varices/PHT among cirrhotic patients. AIM: To predict the presence or absence of esophageal varices by measuring the stiffness of the liver and spleen by ultrasonography (USG)-based acoustic radiation force impulse (ARFI). METHODS: This cross-sectional study included 90 subjects with liver cirrhosis. Liver and splenic stiffness were measured along with the USG abdomen, UGIE and aspartate aminotransferase to platelet ratio index (APRI). RESULTS: Liver and spleen stiffness were significantly higher in cirrhotic patients compared to chronic hepatitis B. The best cut-off value of liver stiffness (LS) obtained by the receiver operating characteristic (ROC) curve was 2.16 m/s for predicting esophageal varices (AUROC 0.78, p 0.0002). The best cut-off value of splenic stiffness (SS) obtained by the ROC curve was 3.04 m/s for predicting esophageal varices (AUROC 0.698, p 0.0274). When both LS and SS were taken together, the accuracy in predicting esophageal varices increased to 92.22%. An equation to predict "esophageal varices = (0.225 LS + 0.377SS) - 0.555" was derived. CONCLUSION: LS and SS values of ≥ 2.16 m/s and 3.04 m/s, respectively, predict esophageal varices independently; however, combined assessment is better with 92% accuracy.

11.
Cancers (Basel) ; 15(20)2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37894331

RESUMEN

PURPOSE: Nontraumatic focal splenic lesions (FSL) are rare, and the need for tissue diagnosis must be weighed against the very high risk of bleeding after a splenic biopsy. The aim of this study was to explore the feasibility and diagnostic potential of acoustic radiation force impulse (ARFI) elastography as a noninvasive method for different benign and malignant FSLs. No human studies on the elastographic characteristics of FSL exist. METHODS: This was a retrospective analysis of 34 patients with FSLs, who underwent abdominal B-mode ultrasound (B-US), contrast-enhanced ultrasound (CEUS), and standardized ARFI examinations between October 2021 and December 2022 at our university hospital. The inclusion criteria were: (i) FSL size ≥ 1 cm; (ii) 10 valid ARFI measurements of the FSL, as well as of the normal splenic parenchyma (NSP) as an in vivo reference; and (iii) diagnostic confirmation of FSL etiology based on histological examination (8/34; 23.5%) or clinical evaluation, which included a clinical and sonographic follow-up (FU), CEUS morphology, and/or morphology on cross-sectional imaging (26/34; 76.5%). CEUS was performed on all patients and the FSLs were classified according to the current guidelines; cross-sectional imaging was available for 29/34 (85.3%). The mean FU duration was 25.8 ± 30.5 months. The mean ARFI velocity (MAV) of the FSL (MAVL), the NSP (MAVP), and the ratio of the MAVL to the MAVP (MAVL/P) were calculated and compared. RESULTS: Of the 34 FSLs, 13 (38.2%) were malignant (mFSL) and 21 (61.8%) were benign (bFSL). The MAVL of all 34 FSLs (2.74 ± 0.71 m/s) was lower than the MAVP (3.20 ± 0.59 m/s), p = 0.009, with a mean MAVL/P ratio of 0.90 ± 0.34. No significant differences in the MAVL were observed between the mFSL (2.66 ± 0.67 m/s) and bFSL (2.79 ± 0.75 m/s). There were also no significant differences between the MAVP in patients with mFSL (3.24 ± 0.68 m/s) as compared to that in the patients with bFSL (3.18 ± 0.55 m/s). Likewise, the MAV L/P ratio did not differ between the mFSL (0.90 ± 0.41 m/s) and bFSL (0.90 ± 0.30 m/s) groups. CONCLUSION: ARFI elastography is feasible in evaluating the stiffness of FSLs. The lesions' stiffness was lower than that of the NSP, regardless of the FSL etiology. However, differentiation between benign and malignant FSL with the help of this elastographic method does not appear possible. Larger prospective studies are needed to validate these findings.

12.
Abdom Radiol (NY) ; 48(11): 3373-3381, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37620709

RESUMEN

PURPOSE: The study aims to determine the role of Sound Touch Elastography [STE] technique in staging liver fibrosis and predicting clinically significant gastro-esophageal varices among patients with chronic liver disease [CLD] keeping aspartate aminotransferase to platelet ratio index [APRI] as the reference standard. METHODS: A prospective short-term study including 60 eligible patients with CLD were staged as non-significant fibrosis [NSF], significant fibrosis [SF] and cirrhosis [C] based on APRI values. STE was performed on each patient obtaining multiple readings as per pre-defined standards. The intra-observer reliability between each measurement and its association with APRI staging was evaluated using relevant statistical variables. Further, Youden's index was used to define the optimum cut-off values on STE in differentiating the stages of fibrosis and in predicting clinically significant gastro-esophageal varices. RESULTS: Based on APRI cut-off values, 41.7% [n = 25] of the study population had cirrhosis, while 45% [n = 27] had significant fibrosis and 13.3% [n = 8] had NSF. The STE values in kPa showed a positive correlation with APRI values [(rs) = 0.837, p < 0.001]. The intra-class correlation estimates based on a mean rating [k = 5] was found to be 0.97 [0.95-0.99], implying an excellent agreement between the measurements. Optimum cut-off values in staging SF and C were 7.26 kPa [J = 0.73, sensitivity-85.19%, specificity-87.5%; 95% CI] and 13.79 kPa [J = 0.84, sensitivity-96.0%, specificity-88.89%; 95% CI]. The AUROC for each of these stages were 0.926 [0.785-0.987] and 0.976 [0.890-0.999], respectively. 23.3% [n = 14] of the study population had clinically significant gastro-esophageal varices with a value above 18.84 kPa [J = 0.88] showing a sensitivity of 92.85% and a specificity of 95.65% in predicting the same. CONCLUSION: The novel STE technique shows good accuracy in staging liver fibrosis as determined by APRI values and in prediction of clinically significant gastro-esophageal varices with excellent reliability. It shows promising prospects and can be integrated widely in clinical practice for assessment and staging of fibrosis in CLD.

13.
J Ultrasound ; 2023 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-37518824

RESUMEN

BACKGROUND: Placental dysfunction is one of the main causes of preeclampsia and hypertensive disorders of pregnancy. MATERIAL AND METHODS: This is a prospective comparative study done on 30 pregnant women with pre-eclampsia and another 30 pregnant women as controls. In all these subjects the elasticity of the placenta was measured. RESULTS: The results obtained showed that there was a significant difference in SWV values between the two groups (p value = 0.001). The mean SWV value of normal pregnant women was 0.99 m/ second as opposed to 1.99 m/second in pre-eclamptic pregnant women. CONCLUSION: Sonoelastography is a promising noninvasive tool in the detection of preeclampsia with high diagnostic accuracy. The SWV values measured at the central zones of the placenta with a cut-off value of 1.325 m/s identify the presence of pre-eclampsia with high sensitivity and specificity.

14.
Front Hum Neurosci ; 17: 1184629, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37180550

RESUMEN

Neuromodulation technology has provided novel therapeutic approaches for diseases caused by neural circuit dysfunction. Transcranial focused ultrasound (FU) is an emerging neuromodulation approach that combines noninvasiveness with relatively sharp focus, even in deep brain regions. It has numerous advantages such as high precision and good safety in neuromodulation, allowing for modulation of both peripheral and central nervous systems. To ensure accurate treatment targeting in FU neuromodulation, a magnetic resonance acoustic radiation force imaging (MR-ARFI) sequence is crucial for the visualization of the focal point. Currently, the commonly used 2D Spin Echo ARFI (2D SE-ARFI) sequence suffers from the long acquisition time, while the echo planar imaging ARFI (EPI-ARFI) sequence with a shorter acquisition time is vulnerable to the magnetic field inhomogeneities. To address these problems, we proposed a spatiotemporal-encoded acoustic radiation force imaging sequence (i.e., SE-SPEN-ARFI, shortened to SPEN-ARFI) in this study. The displacement at the focal spot obtained was highly consistent with that of the SE-ARFI sequence. Our research shows that SPEN-ARFI allows for rapid image acquisition and has less image distortions even under great field inhomogeneities. Therefore, a SPEN-ARFI sequence is a practical alternative for the treatment planning in ultrasound neuromodulation.

15.
Ultrasound Med Biol ; 49(8): 1768-1779, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37202245

RESUMEN

OBJECTIVE: Ultrasound elasticity imaging techniques aim to provide a non-invasive characterization of tissue mechanical properties to detect pathological changes and monitor disease progression. Harmonic motion imaging (HMI) is an ultrasound-based elasticity imaging technique that utilizes an oscillatory acoustic radiation force to induce localized displacements and estimate relative tissue stiffness. Previous studies have applied a low amplitude modulation (AM) frequency of 25 or 50 Hz in HMI to assess the mechanical properties of different tissue types. In this study, we investigate the dependence of AM frequency in HMI and whether the frequency can be adjusted based on the size and mechanical properties of the underlying medium for enhanced image contrast and inclusion detection. METHODS: A tissue-mimicking phantom with embedded inclusions at different sizes and stiffnesses was imaged within a range of AM frequencies from 25 to 250 Hz at 25-Hz step size. DISCUSSION: The AM frequency at which the maximum contrast and CNR are achieved depends on the size and stiffness of the inclusions. A general trend shows that contrast and CNR peak at higher frequencies for smaller inclusions. In addition, for some inclusions with the same size but different stiffnesses, the optimized AM frequency increases with the stiffness of the inclusion. Nevertheless, there is a shift between the frequencies at which the contrast peaks and those with maximum CNR. Finally, in agreement with the phantom findings, imaging an ex-vivo human specimen with a 2.7-cm breast tumor at a range of AM frequencies showed that the highest contrast and CNR are achieved at the AM frequency of 50 Hz. CONCLUSION: These findings indicate that the AM frequency can be optimized in different applications of HMI, especially in the clinic, for improved detection and characterization of tumors with different geometries and mechanical properties.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias , Humanos , Ultrasonografía , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Fantasmas de Imagen
16.
Front Oncol ; 13: 1115485, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37025603

RESUMEN

Virtual Touch Tissue Quantification (VTQ) offers several advantages in the diagnosis of various lung diseases. Chemokine expression levels, such as CXCL13, play a vital role in the occurrence and development of tumors and aid in the diagnosis process. The purpose of this study was to evaluate the combined value of VTQ and changes in CXCL13 expression levels for the diagnosis of lung tumors. A total of 60 patients with thoracic nodules and pleural effusion were included, with 30 of them having malignant pleural effusion (based on pathology) and the remaining 30 having benign thoracic nodules and pleural effusion. The relative expression level of CXCL13 was measured in the collected pleural effusions using Enzyme-Linked Immunosorbent Assay (ELISA). The relationship between CXCL13 expression levels and various clinical features was analyzed. A Receiver Operating Characteristic (ROC) curve analysis was conducted on the VTQ results and relative expression levels of CXCL13, and the areas under the curve, critical values, sensitivity, and specificity were calculated. Multivariate analysis incorporating multiple indicators was performed to determine the accuracy of lung tumor diagnosis. The results showed that the expression levels of CXCL13 and VTQ were significantly higher in the lung cancer group compared to the control group (P < 0.05). In the Non-Small Cell Lung Cancer (NSCLC) group, CXCL13 expression levels increased with later TNM staging and poorer tumor differentiation. The expression level of CXCL13 in adenocarcinoma was higher than that in squamous cell carcinoma. The ROC curve analysis revealed that CXCL13 had an area under the curve (AUC) of 0.74 (0.61, 0.86) with an optimal cut-off value of 777.82 pg/ml for diagnosing lung tumors. The ROC curve analysis of VTQ showed an AUC of 0.67 (0.53, 0.82) with a sensitivity of 60.0% and a specificity of 83.3%, and an optimal diagnostic cut-off of 3.33 m/s. The combination of CXCL13 and VTQ for diagnosing thoracic tumors had an AUC of 0.842 (0.74, 0.94), which was significantly higher than either factor alone. The results of the study demonstrate the strong potential of combining VTQ results with chemokine CXCL13 expression levels for lung tumor diagnosis. Additionally, the findings suggest that elevated relative expression of CXCL13 in cases of malignant pleural effusion caused by non-small cell lung cancer may indicate a poor prognosis. This provides promising potential for using CXCL13 as a screening tool and prognostic indicator for patients with advanced lung cancer complicated by malignant pleural effusion.

17.
Front Oncol ; 13: 1170338, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36937427

RESUMEN

[This corrects the article DOI: 10.3389/fonc.2022.1025481.].

18.
Diabetol Metab Syndr ; 15(1): 52, 2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36941617

RESUMEN

BACKGROUND: Type 1 diabetes mellitus (T1DM) patients are at an increased risk for non-alcoholic fatty liver disease (NAFLD). This study aimed to evaluate the clinical criteria associated with the diagnosis of Non-Alcoholic Fatty Liver Disease (NAFLD) among T1DM Egyptian children and adolescents. METHODS: 74 T1DM patients aged 8-18 year were enrolled in this cross sectional study. Assessments of Clinical status, anthropometric measures, lipid profile, glycated haemoglobin (HbA1c) and liver enzymes were done. Abdominal Ultrasound evaluation of hepatic steatosis was done. Accordingly, patients were divided into two groups (NAFLD and normal liver group) and compared together. Assessment of liver fibrosis using acoustic radiation force impulse elastography (ARFI) was done. Statistical analysis included; independent t-test, Chi square and Fisher's Exact, Pearson and Spearman tests and Logistic regression models for factors associated with fatty liver were used when appropriate. RESULTS: In this study; 74 patients were enrolled; 37 males (50%) and 37 females with mean age 14.3 ± 3.0 year. The mean insulin dose was 1.1 ± 0.4 U/kg and mean disease duration was 6.3 ± 3.0 year. NAFLD was detected in 46 cases while 28 cases had normal liver as diagnosed by abdominal ultrasound. Cases with NAFLD had statistically significant higher BMI-Z scores, waist/hip, waist/height and sum of skin fold thicknesses compared to those with normal liver (P < 0.05). The mean value of HbA1c % was significantly higher in NAFLD group (P = 0.003). Total cholesterol, triglycerides and LDL serum levels were significantly elevated (p < 0.05), while the HDL level was significantly lower in NAFLD cases (p = 0.001). Although, serum levels of liver enzymes; ALT and AST were significantly higher among cases with NAFLD than in normal liver group (p < 0.05), their means were within normal. Using the ARFI elastography; NAFLD cases exhibited significant fibrosis (F2, 3 and 4). BMI, patient age and female gender were among risk factors for NAFLD. CONCLUSIONS: NAFLD represents a serious consequence in type 1 diabetic children and adolescents that deserves attention especially with poor glycemic control. NAFLD has the potential to evolve to fibrosis. This study demonstrated a very high prevalence of NAFLD in T1D children and adolescents using US which was (62.2%) with the percent of liver fibrosis among the NAFLD cases (F2-F4) using ARFI elastography was 26%. BMI, age of patients and female gender were detected as risk factors for NAFLD.

19.
Liver Int ; 43(4): 878-887, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36797990

RESUMEN

BACKGROUND: Novel cystic fibrosis transmembrane conductance regulator (CFTR) modulator therapies (elexacaftor/tezacaftor/ivacaftor-ETI) promise clinically significant and sustained improvements for patients with cystic fibrosis (CF). In this study, we investigated the impact of ETI therapy on liver stiffness and bile acid metabolism in a cohort of children and young adults with CF. METHODS: A prospective observational study (NCT05576324) was conducted from September 2020 to November 2021 enrolling CF patients naive to ETI. Standard laboratory chemistry, sweat test, lung function, share wave velocity (SWV) derived by acoustic radiation force impulse imaging (ARFI) and serum bile acid profiles were assessed before and 6 months after induction of ETI therapy. RESULTS: A total of 20 patients (10 aged <20 years) completed the study. While lung function and BMI improved after ETI therapy, ARFI SWV increased in CF patients <20 years of age (from 1.27 to 1.43 m/s, p = 0.023). Bile acid (BA) profiles revealed a decrease in unconjugated (5.75 vs 1.46, p = 0.007) and increase in glycine-conjugated derivatives (GCDCA) (4.79 vs 6.64 p = 0.016). There was a positive correlation between ARFI SWV values and GCDCA (r = 0.80, p < 0.0001). Glycine-conjugated BA provided high diagnostic accuracy to predict increased ARFI measurements (AUC 0.90) and clinical (Colombo) CFLD grading (AUC 0.97). CONCLUSIONS: ARFI SWV and bile acid profiles provide evidence for early increase in liver stiffness and altered bile acid metabolism in young CF patients after initiation of ETI and may serve as synergistic measures for detection of hepatic complications during ETI therapy.


Asunto(s)
Fibrosis Quística , Diagnóstico por Imagen de Elasticidad , Humanos , Niño , Adulto Joven , Adulto , Fibrosis Quística/tratamiento farmacológico , Fibrosis Quística/complicaciones , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Diagnóstico por Imagen de Elasticidad/métodos , Cognición , Hígado/diagnóstico por imagen , Mutación
20.
Curr Med Imaging ; 19(6): 631-635, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36380445

RESUMEN

BACKGROUND: The most common etiology of shoulder pain in adults is rotator cuff tear. Elastography is an imaging method that can report the strain and elastic modulus of the biological tissue. We think acoustic radiation force impulse (ARFI) elastography can effectively assess rotator cuff tendinopathy. PURPOSE: This study aimed to investigate the usefulness of ARFI elastography in evaluating supraspinatus tendinopathy. MATERIALS AND METHODS: We included 44 patients (22 men, 22 women, median age, 47 years; range, 20-69 years) with unilateral supraspinatus tendinopathy diagnosed with magnetic resonance imaging (MRI) in this prospective study. The normal tendons and tendinopathies, including supraspinatus tendinosis, partial-thickness, and full-thickness supraspinatus tears, were evaluated with ultrasound and ARFI elastography. The ARFI elastography values were compared between healthy and tendinopathy groups, and the gender was compared between elastography values of the normal tendons and tendinopathies using the Mann-Whitney U test. RESULTS: The values of ARFI elastography correlated with tendinopathy. (P = 0.001). The gender differed between the elastography values of the normal tendons (P = 0.002) and tendinopathies (P = 0.001). CONCLUSION: ARFI elastography is a non-invasive and feasible method for quantitatively assessing supraspinatus tendinopathy. It can be an alternative method to MRI in diagnosing supraspinatus tendinopathy.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Lesiones del Manguito de los Rotadores , Tendinopatía , Adulto , Masculino , Humanos , Femenino , Persona de Mediana Edad , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/patología , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Prospectivos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/patología , Tendinopatía/diagnóstico por imagen , Tendinopatía/patología , Acústica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA