Resultados 1 - 20 de 1.051
Filtrar
1.
Acta Diabetol ; 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39031189

RESUMEN

AIMS: To monitor fetal size and identify predictors for birthweight in women with gestational diabetes (GDM) and normal glucose tolerance (NGT). METHODS: Cohort study of 1843 women universally screened for GDM, with routine ultrasounds each trimester. Women with GDM and NGT were categorized in subgroups by birthweight centile. RESULTS: Of the total cohort, 231 (12.5%) women were diagnosed with GDM. Fetal size, incidence of large-for-gestational age (LGA: 12.3% of GDM vs. 12.9% of NGT, p = 0.822) and small-for-gestational age (SGA) neonates (4.8% of GDM vs. 5.1% of NGT, p = 0.886) were similar between GDM and NGT. GDM women with LGA neonates were more insulin resistant at baseline and had more often estimated fetal weight (EFW) ≥ P90 on the 28-33 weeks ultrasound (p = 0.033) than those with AGA (appropriate-for-gestational age) neonates. Compared to NGT women with AGA neonates, those with LGA neonates were more often obese and multiparous, had higher fasting glycemia, a worse lipid profile, and higher insulin resistance between 24 -28 weeks, with more often excessive gestational weight gain. On the 28-33 weeks ultrasound, abdominal circumference ≥ P95 had a high positive predictive value for LGA neonates in GDM (100%), whereas, in both GDM and NGT, EFW ≥ P90 and ≤ P10 had a high negative predictive value for LGA and SGA neonates (> 88%), respectively. CONCLUSIONS: There were no differences in fetal size throughout pregnancy nor in LGA incidence between GDM and NGT women. EFW centile at 28-33 weeks correlated well with birthweight. This indicates that GDM treatment is effective and targeted ultrasound follow-up is useful. TRIAL REGISTRATION CLINICALTRIALS.GOV: NCT02036619. Registration date: January 15, 2014. https://clinicaltrials.gov/ct2/show/NCT02036619 .

2.
Artículo en Inglés | MEDLINE | ID: mdl-39032032

RESUMEN

INTRODUCTION: The emergence of handheld ultrasound devices capable of connecting to cell phones or tablets heralds a significant advancement in medical technology, particularly within the field of obstetrics. These devices offer the promise of immediate bedside ultrasound examinations, potentially revolutionizing patient care by enabling fetal assessments in diverse settings. MATERIAL AND METHODS: This prospective study aimed to validate the reliability of non-piezo, chip-based handheld ultrasound devices in clinical obstetric practice. Conducted in a university hospital obstetric ward, the study included 100 pregnant women between 17 and 41 weeks of gestation. Participants underwent ultrasound examinations using both conventional and portable point-of-care ultrasound (POCUS) devices to compare the accuracy in estimating fetal weight and other parameters, such as cardiac activity, fetal presentation, placental location, and amniotic fluid volume. The reliability and agreement between the devices were assessed using intraclass correlation coefficients, Bland-Altman plots, and Pearson correlation coefficients. RESULTS: The results show a near-perfect agreement (0.98) and correlation (r = 0.98, p < 0.001) for estimated fetal weight and most biometry measurements between the two types of ultrasound devices, with slight deviations in head circumference and amniotic fluid index measurements. Subgroup analysis revealed variations in agreement and correlation rates with higher BMI and advanced gestational age, indicating areas for further refinement. CONCLUSIONS: These findings affirm the high reliability of handheld ultrasound devices for basic obstetric ultrasound evaluations, supporting their integration into daily clinical practice. This technology improves the flexibility and immediacy of prenatal care, although further research is needed to optimize its application across patient populations and treatment settings.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39046518

RESUMEN

BACKGROUND: To evaluate the repeatability and agreement of two different ocular biometers and Scheimpflug devices in keratoconus eyes. METHODS: This prospective, comparative trial took place at the University hospital, Goethe University, Frankfurt am Main, Germany. We included eyes with keratoconus, one eye per patient, randomly selected. Measurements were taken with Galilei G6 (Ziemer, Switzerland) and Pentacam AXL (Oculus, Germany), three consecutive measurements each. Repeatability and agreement were evaluated for simulated keratometry (simK), astigmatism (simA), maximum keratometry (KMax) and its axis, total keratometry (TCP), axial length (AL), anterior chamber depth (ACD), and thinnest pachymetry (TCT). RESULTS: Both devices showed an excellent repeatability with intra class correlation (ICC) of > 0.97 for all parameters. The 95% limits of repeatability (LoR95%) and agreement (LoA95%) were narrow for all parameters. The Galilei G6 had a narrower LoAR95% for TCT (2.1 µm vs. 4.6 µm), but a wider LoR95% for KMax (0.52D vs. 1.18D). No relevant difference was found for the other parameters. Agreement between the devices was good to moderate, especially for simK and TCP. CONCLUSIONS: Both devices show excellent repeatability with narrow LoR95% and high ICC for all parameters. The only relevant difference was found for KMax and TCT in favor of Pentacam AXL and Galilei G6, respectively. Agreement was good to moderate, and most parameters should not be considered interchangeable.

4.
Clin Exp Ophthalmol ; 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-39034156

RESUMEN

BACKGROUND: To assess changes in ocular biometry of the phakic eye after pars-plana-vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment. METHODS: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000-centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept-source optical coherence tomography-based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed. RESULTS: The mean age was 62.1 ± 8.3 years (range: 37-85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to -0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation. CONCLUSIONS: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.

5.
J Matern Fetal Neonatal Med ; 37(1): 2380726, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39054063

RESUMEN

OBJECTIVE: To construct fetal limb bone nomograms in the Chinese ethnic population. METHODS: This was a prospective cross-sectional study on singleton pregnancies between 12 and 37 weeks of gestation. Femur, tibia, fibula, humerus, ulna, radius, and foot length were measured in a standardized manner by one of the three sonographers. Each fetus's measurements were only included once and those who developed maternal or fetal complications were excluded. Fractional polynomial regression model was used to obtain the 3rd, 10th, 50th, 90th, and 97th centiles for each of the limb measurement. Z-score for the 50th centile of each fetal limb measurement was then compared with published nomograms derived from other populations. RESULTS: Of the 843 scans performed, 775 were included in analysis after excluding conditions such as pre-eclampsia, chromosomal abnormalities, single umbilical artery and skeletal dysplasia. Comparison with other populations showed that Chinese had shorter fetal limb bone lengths than the Caucasian and Afro-Caribbean populations. CONCLUSION: This study established nomograms for all the fetal limb bones in the Chinese ethnic population, which showed lengths comparatively shorter than Caucasian and Afro-Caribbean nomograms. This would reduce the false alarm of short fetal limb bone lengths and its consequent anxiety and intervention.


Asunto(s)
Pueblo Asiatico , Nomogramas , Ultrasonografía Prenatal , Humanos , Femenino , Embarazo , Estudios Transversales , Estudios Prospectivos , China/etnología , Adulto , Pueblos del Este de Asia
6.
Heliyon ; 10(13): e33987, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39055816

RESUMEN

Purpose: To investigate the refractive and ocular biometric characteristics of children with mild hyperopia and distinguish between non-myopic and pseudomyopic eyes before cycloplegia. Methods: The eligible children underwent refractive error measurements using a NIDEK autorefractor before and after the administration of 0.5 % tropicamide. Ocular biometric parameters, including axial length (AL), anterior chamber depth (ACD), and lens thickness (LT), were measured using the IOLMaster 700 before cycloplegia. We performed comparative analyses between the non-myopic and pseudomyopic groups, categorized based on whether the spherical equivalent (SE) before cycloplegia exceeded -0.50 diopters (D). Univariable and multivariable regression analyses were performed to control for confounding factors. Results: The final analysis included 968 eyes. The participants with pseudomyopia were more likely to be boys (P = 0.029), younger (P = 0.004), less hyperopic (P < 0.001) after cycloplegia, and exhibit a higher delta SE (P < 0.001) compared to the non-myopic participants. Pseudomyopic eyes were associated with a shallower ACD (P = 0.004) and thicker LT (P < 0.001) than non-myopic eyes. After adjusting for sex, age, and SE, pseudomyopic eyes showed increased AL (P = 0.001) and LT (P < 0.001) and decreased ACD (P = 0.005) compared with non-myopic eyes before cycloplegia. Conclusions: Among the children with mild hyperopia, pseudomyopia was more common in younger boys with a lower cycloplegic SE and higher delta SE. A thicker LT, shallower ACD, and increased AL may indicate the presence of pseudomyopia, which may provide insights into the rapid progression of myopia in children with pseudomyopia.

7.
Trop Anim Health Prod ; 56(6): 193, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958783

RESUMEN

The objective of the study was to evaluate the effect of the inclusion of cocoa bran in the diet of lambs and its effect on reproductive parameters. For this, 40 lambs were randomly assigned to four treatments, and including 0, 10, 20 and 30% levels of cocoa bran in the concentrate. Blood was collected to measure cholesterol and testosterone and semen for physical and morphological evaluation; testicular biometry and morphometry were also evaluated. There was significant difference (P < 0.05) in body weight and tubulosomatic index between the lambs in the control treatment and those in the 30% cocoa bran treatment. There was no difference in testicular biometry, physical and morphological parameters of fresh semen, testicular morphometry, and volumetric ratio between lambs in all the treatments (P < 0.05). In addition, there was no difference in plasma cholesterol or testosterone concentration (P > 0.05). Thus, it is possible to include up to 30% of cocoa bran in diet without affecting the reproductive parameters of lambs.


Asunto(s)
Alimentación Animal , Colesterol , Dieta , Oveja Doméstica , Testículo , Testosterona , Animales , Masculino , Alimentación Animal/análisis , Dieta/veterinaria , Testículo/anatomía & histología , Oveja Doméstica/fisiología , Testosterona/sangre , Colesterol/sangre , Colesterol/análisis , Cacao/química , Reproducción , Semen/fisiología , Fenómenos Fisiológicos Nutricionales de los Animales , Distribución Aleatoria , Ovinos/fisiología
8.
Reprod Domest Anim ; 59(6): e14621, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38828534

RESUMEN

Estimating the parturition date in dogs is challenging due to their reproductive peculiarities that. Ultrasonographic examination serves as a tool for studying embryo/foetal biometry and estimating the time of parturition by measuring foetal and extra-foetal structures. However, due to reproductive differences among various dog breeds, such estimates may have a non-significant pattern, representing inaccuracies in the estimated date of birth. This study aimed to monitor pregnant Toy Poodle bitches and establish relationships between ultrasonographically measured foetal and extra-foetal dimensions and the remaining time until parturition. Eighteen pregnant Toy Poodle bitches were subjected to weekly ultrasonographic evaluations and measurements of the inner chorionic cavity diameter, craniocaudal length (CCL), biparietal diameter (BPD), diameter of the deep portion of diencephalo-telencephalic vesicle (DPTV), abdominal diameter, thorax diameter (TXD), placental thickness and the renal diameter (REND). These parameters were retrospectively correlated with the date of parturition and linear regressions were established between gestational measurements and days before parturition (DBP). All analyses were conducted using the Statistical Package for Social Sciences (IBM® SPSS®) program at a 5% significance level. The foetal measurements that showed a high correlation (r) and reliability (R2) with DBP were BPD [(DBP = [15.538 × BPD] - 39.756), r = .97 and R2 = .93], TXD [(DBP = [8.933 × TXD] - 32.487), r = .94 and R2 = .89], DPTV [(DBP = [34.580 × DPTV] - 39.403), r = .93 and R2 = .86] and REND [(DBP = [13.735 × REND] - 28.937), r = .91 and R2 = .82]. This statistically validates the application of these specific formulas to estimate the parturition date in Toy Poodle bitches.


Asunto(s)
Parto , Ultrasonografía Prenatal , Animales , Femenino , Embarazo , Perros/embriología , Ultrasonografía Prenatal/veterinaria , Biometría , Feto/anatomía & histología , Feto/diagnóstico por imagen , Estudios Retrospectivos , Placenta/diagnóstico por imagen , Placenta/anatomía & histología , Embrión de Mamíferos/fisiología , Edad Gestacional
9.
Clin Ophthalmol ; 18: 1761-1769, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38915745

RESUMEN

Purpose: To compare the accuracy of modern intraocular lens (IOL) power calculation formulas with that of older formulas, such as SRK/T and Hoffer Q, in pediatric cataract surgery. Methods: This retrospective study included 100 eyes of 100 children who underwent routine cataract surgery with primary IOL implantation in a bag. This study used four IOLMaster 700 integrated formulas: SRK/T, Hoffer Q, Haigis, and Barrett Universal II (BUII). In addition, the following formulas were used: EVO 2.0, Hill RBF 3.0, Hoffer QST, Kane, and PEARL DGS, which are available online. Results: There was a statistically significant difference between SRK/T and most other formulas, except for Hoffer Q, Hoffer QST, and BUII (p < 0.05). SRK/T yielded the lowest median absolute error (MedAE) of 0.63 D. This was followed by the BUII (0.66 D), Hoffer Q, and Hoffer QST (0.68 D). SRK/T also yielded the highest percentage of cases within ± 0.50 D (43% of the cases). For patients aged 2 to 5 years, SRK/T formula yielded statistically significantly better results than all other included formulas (p < 0.05) with MedAE = 0.44 D, 58.33% and 87.50% of the cases were within ± 0.50 D and ± 1.0 D of intended refraction, respectively. Conclusion: The SRK/T formula showed the best IOL power calculation results in pediatric cataract surgery, followed by BUII, Hoffer Q, and Hoffer QST. In children aged 2-5 years, the SRK/T formula outperformed all other formulas, followed by the BUII and Hoffer QST formulas. In children older than 5 years, there was no statistically significant difference between the different formulas (p > 0.05); Hoffer Q and SRK/T showed slightly better MedAE in this age group (5-10 years).

10.
Primates ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38884897

RESUMEN

Friction ridges are important and unique biometric features that have been studied in fingerprint science since antiquity and used for human identification. This study aimed to analyze palmprints and soleprints of Callithrix penicillata, including the description of flexion creases, regions, minutiae classification, and delta counting, in order to evaluate the uniqueness of these data and feasibility of using this information as an identification method. Palmprints and footprints were collected using commercial fingerprint ink on A4 size paper. Following image digitalization using the GIMP (2.10.14) image editing program, regions and flexion creases were identified. A total of 600 minutiae were classified in females (288 palms and 312 soles) and 732 in males (360 palms and 372 soles), and all deltas were counted. It was possible to identify three main inconstant flexion creases, in both palmprints and soleprints, with different distribution and orientation when compared to those in humans. Less variety in the types of minutiae and differences in the distribution of deltas were found when compared to human studies. In addition, the hypothesis of non-coincident characteristics in each sample was confirmed.

11.
Comput Biol Med ; 175: 108501, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38703545

RESUMEN

The segmentation of the fetal head (FH) and pubic symphysis (PS) from intrapartum ultrasound images plays a pivotal role in monitoring labor progression and informing crucial clinical decisions. Achieving real-time segmentation with high accuracy on systems with limited hardware capabilities presents significant challenges. To address these challenges, we propose the real-time segmentation network (RTSeg-Net), a groundbreaking lightweight deep learning model that incorporates innovative distribution shifting convolutional blocks, tokenized multilayer perceptron blocks, and efficient feature fusion blocks. Designed for optimal computational efficiency, RTSeg-Net minimizes resource demand while significantly enhancing segmentation performance. Our comprehensive evaluation on two distinct intrapartum ultrasound image datasets reveals that RTSeg-Net achieves segmentation accuracy on par with more complex state-of-the-art networks, utilizing merely 1.86 M parameters-just 6 % of their hyperparameters-and operating seven times faster, achieving a remarkable rate of 31.13 frames per second on a Jetson Nano, a device known for its limited computing capacity. These achievements underscore RTSeg-Net's potential to provide accurate, real-time segmentation on low-power devices, broadening the scope for its application across various stages of labor. By facilitating real-time, accurate ultrasound image analysis on portable, low-cost devices, RTSeg-Net promises to revolutionize intrapartum monitoring, making sophisticated diagnostic tools accessible to a wider range of healthcare settings.


Asunto(s)
Cabeza , Sínfisis Pubiana , Ultrasonografía Prenatal , Humanos , Femenino , Embarazo , Cabeza/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Sínfisis Pubiana/diagnóstico por imagen , Aprendizaje Profundo , Feto/diagnóstico por imagen
12.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742496

RESUMEN

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Asunto(s)
Biometría , Lentes Intraoculares , Facoemulsificación , Refracción Ocular , Humanos , Biometría/métodos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Reproducibilidad de los Resultados , Refracción Ocular/fisiología , Facoemulsificación/métodos , Longitud Axial del Ojo/diagnóstico por imagen , Implantación de Lentes Intraoculares/métodos , Catarata/fisiopatología , Catarata/diagnóstico , Óptica y Fotónica/métodos , Microscopía Acústica/métodos
13.
Clin Ophthalmol ; 18: 1191-1206, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711575

RESUMEN

One of the most recent advancements in the field of cataract surgery is optical biometry. With the advent of optical biometry ocular measurements are now simpler, quicker, and more precise. The devices have made intraocular lens (IOL) power calculations easier in difficult situations too, such as in cases with extremes of axial lengths, silicone filled eyes, cataract surgery in post-keratoplasty eyes, post Laser-Assisted in Situ Keratomileusis (LASIK) eyes, etc. The gold standard for IOL power calculation in the present day is by the use of optical biometry devices. The anatomical measurements by these devices are highly precise and because of these measurements and the incorporation of various IOL power calculation formulas the optical biometry devices give the accurate power and the post-operative visual outcome is highly satisfactory among the patients. The growing use of these devices has made cataract the most commonly performed refractive surgical procedure nowadays. In the current scenario, optical biometry has widespread acceptance in almost all countries and has many advantages over ultrasound or immersion biometry. Cataract surgeons can obtain easy and reliable measurements from these devices. Refractive surprises have also decreased considerably with their use. This article will comprehensively review the principles of the various optical biometry devices, the parameters used in each of the devices, the advantages and disadvantages, and add more like what all this article will add.

14.
Ophthalmic Epidemiol ; : 1-8, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709173

RESUMEN

PURPOSE: This study was aimed to evaluate the agreement between the swept-source optical coherence tomography (SS-OCT)-based biometry, fundus photographs, and their combination, in comparison to the gold standard spectral-domain optical coherence tomography (SD-OCT) for the detection of center-involving diabetic macular edema (CI-DME). METHODS: We conducted a retrospective cross-sectional study involving 55 subjects (78 eyes) diagnosed with diabetic macular edema (DME) detected clinically and on SD-OCT (Carl Zeiss Meditec AG). Post-mydriatic 45-degree color fundus photograph (Crystal-Vue NFC-700), 1 mm macular scan obtained from SS-OCT-based biometry (IOL-Master 700), and macula cube scan obtained from SD-OCT was used to detect and grade DME into CI-DME and NCI-DME. RESULTS: Our findings revealed that SS-OCT-based biometry was noted to have a high sensitivity of 1 (0.94-1.00) and a specificity of 0.63 (0.31-0.89) in detecting CI-DME compared to the gold standard (SD-OCT). When combined with data from fundus photographs, specificity decreased to 0.32 (0.15-0.53). Fundus photographs alone exhibited a low sensitivity of 0.52 (0.38-0.64) and a specificity of 0.45 (0.16-0.76) in CI-DME detection. CONCLUSION: In conclusion, SS-OCT-based biometry can be used as an effective tool for the detection of CI-DME in diabetic patients undergoing cataract surgery and can serve as a screening tool in centers without SD-OCT facilities.


Diabetic Macular Edema (DME); Center Involving Diabetic Macular Edema (CI-DME); Non-Center Involving Diabetic Macular Edema (NCI-DME); Swept-Source Optical Coherence Tomography (SS-OCT); Spectral-Domain Optical Coherence Tomography (SD-OCT); Anti-Vascular Endothelial Growth Factor (Anti-VEGF); Central Retinal Thickness (CRT); Intra Retinal Fluid (IRF); Sub Retinal Fluid (SRF); Diabetic Retinopathy (DR); Non Proliferative Diabetic Retinopathy (NPDR); Proliferative Diabetic Retinopathy (PDR); Best Corrected Visual Acuity (BCVA); Glycosylated hemoglobin (HbA1c); Mean Spherical Error (MSE); Standard Deviation (SD); Positive Predictive value (PPV); Predictive value (PPV); Negative predictive value (NPV); Area under the Curve (AUC).

15.
Ophthalmic Physiol Opt ; 44(5): 1017-1030, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38760986

RESUMEN

PURPOSE: To assess the feasibility of using multifunction instruments to measure axial length for monitoring myopia progression in children and adults. METHODS: Axial length was measured in 60 children (aged 6-18 years) and 60 adults (aged 19-50 years) with multifunction instruments (Myah and Myopia Master) and stand-alone biometers (Lenstar LS900 and IOLMaster 700). Repeatability (measurements by the same examiner) and reproducibility (measurements by different examiners) were computed as the within-subject standard deviation (Sw) and 95% limits of agreement (LoA). Inter-instrument agreement was computed as intraclass correlation coefficients. The threshold for detecting myopic progression was taken as 0.1 mm. Measures were repeated only in children following the administration of 1% tropicamide to determine the impact of cycloplegia on axial length. RESULTS: Overall, the IOLMaster 700 had the best repeatability in children (0.014 mm) and adults (0.009 mm). Repeatability Sw values for all devices ranged from 0.005 to 0.021 mm (children) and 0.003 to 0.016 mm (adults). In children, reproducibility fell within 0.1 mm 95% of the time for the Myah, Myopia Master and IOLMaster 700. Agreement among all devices was classified as excellent (ICC 0.999; 95% CI 0.998-0.999), but the 95% LoA among the Myah, Myopia Master and Lenstar LS900 was ≥0.1 mm. Cycloplegia had no statistically significant effect on axial length (all p > 0.13). CONCLUSIONS: The Myah and Myopia Master multifunction instruments demonstrated good repeatability and reproducibility, and their accuracy was comparable to stand-alone biometers. Axial length measurements using different instruments can be considered interchangeable but should be compared with some caution. Accurate axial length measurements can be obtained without cycloplegia. The multifunction instruments Myah and Myopia Master are as well suited for monitoring myopia progression in children as the stand-alone biometers IOLMaster 700 and Lenstar LS900.


Asunto(s)
Longitud Axial del Ojo , Progresión de la Enfermedad , Miopía , Humanos , Niño , Adolescente , Masculino , Femenino , Adulto , Reproducibilidad de los Resultados , Adulto Joven , Longitud Axial del Ojo/diagnóstico por imagen , Miopía/fisiopatología , Miopía/diagnóstico , Persona de Mediana Edad , Biometría/instrumentación , Biometría/métodos , Refracción Ocular/fisiología , Estudios de Factibilidad
16.
Heliyon ; 10(7): e29234, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38601661

RESUMEN

This research focused on analyzing the biometric, colorimetric and morphological characteristics of thirty seeds, covering legumes, cereals and oilseeds. Thirteen legumes, fourteen cereals and three oilseeds were collected from three different locations. The methodology used was descriptive, applying multivariate multiple factorial and cluster analysis. The results showed variability between biometric, chromatic and morphological characteristics among the seeds. Predominant shapes include circular, oval, oblong, less frequently kidney and lanceolate. Significant differences in biometric parameters stand out, evidencing similarities in colorimetric parameters. Specifically, Pallar and Bean exhibited greater equatorial dimensions, length, weight, 100 g weight, area and perimeter, While peanut and Chickpea presented greater thickness. In terms of colorimetry - luminosity, Pallar, Yellow corn and Tarwi presented higher values unlike Black lentils, Purple corn and Black beans, being less luminous. Multivariate tests revealed the formation of four groups based on the parameters studied. This study provides valuable information about the different seeds, establishing a basis for their propagation and improvement in the Peruvian context.

17.
Front Med (Lausanne) ; 11: 1363286, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38665295

RESUMEN

Purpose: To compare different corneal keratometry readings (swept-source-OCT-assisted biometry and Scheimpflug imaging) with a novel software platform for calculation of toric intraocular lenses. Setting: Department of Ophthalmology, Ludwig-Maximilians-University, Munich, Germany. Design: Retrospective, non-randomized, clinical trial. Methods: Twenty-three eyes undergoing toric intraocular lens implantation were included. Inclusion criteria were preoperative regular corneal astigmatism of at least 1.00 D, no previous refractive surgery, no ocular surface diseases and no maculopathies. Lens exchange was performed with CALLISTO eye (Zeiss). For each patient, the expected postoperative residual refraction was calculated depending on three different corneal parameters of two different devices: standard K-front (K) and total keratometry (TK) obtained by a swept-source-OCT-assisted biometry system (IOL Master 700, Zeiss) as well as total corneal refractive power (TCRP) obtained by a Scheimpflug device (Pentacam AXL, Oculus). Barrett's formula for toric intraocular lenses was used for all calculations within a novel software platform (EQ workplace, Zeiss FORUM®). Results were statistically compared with postoperative refraction calculated according to the Harris dioptric power matrix. Results: The standard K values (mean PE 0.02 D ± 0.45 D) and TK values (mean PE 0.09 D ± 0.43 D) of the IOL Master 700 reached similar results (p = 0.96). 78% of eyes in both K and TK groups achieved SE within ±0.5 D of attempted correction and all eyes (100%) were within ±1.0 D of attempted correction in both groups. By contrast, the prediction error in the IOL calculation using the TCRP of the Scheimpflug device was significantly greater (mean PE -0.56 D ± 0.49 D; p = 0.00 vs. standard K and p = 0.00 vs. TK) with adjusted refractive indices. Thirty-nine and Ninety-one percentage of eyes in the TCRP group achieved SE within ±0.5 D (p = 0.008 K vs. TCRP and p = 0.005 TK vs. TCRP) and ± 1.0 D (p = 0.14 vs. TCRP) of attempted correction, respectively. Conclusion: All three corneal parameters (standard K, TK, TCRP) performed well in calculating toric IOLs. The most accurate refractive outcomes in toric IOL implantation were achieved by IOL calculations based on swept-source-OCT-assisted biometry. The SS-OCT-based K-front and TK values achieve comparable results in the calculation of toric IOLs.

18.
J Med Ultrasound ; 32(1): 41-47, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38665343

RESUMEN

Background: To explore the relationship between fetal Transverse Cerebellar Diameter (TCD) and menstrual gestational age (GA) and to generate normative references (nomogram) of the fetal TCD in some pregnant women in Southwest Nigeria. Methods: Four hundred pregnant women with a singleton fetus between 14 and 38 weeks GA were enrolled. The TCD and other biometric parameters (biparietal diameter, head circumference, abdominal circumference, and femur length) as well as the cerebellar appearance were analyzed and correlated with the GA. Results: The mean TCD increased from 13.3 ± 0.3 mm at 14 weeks to 52.3 ± 3.3 mm at 38 weeks of pregnancy. A strong positive correlation was observed between TCD and GA, which was best represented by a linear regression equation: Predicted GA = 0.557 × TCD + 8.840. The regression analysis indicated a statistically significant strong positive relationship between TCD and GA (r = 0.972 and P < 0.001). The cerebellar appearance based on shape and echogenicity was graded into Grade I: 230 fetuses (57.5%); Grade II: 74 fetuses (18.5%) and Grade III: 96 fetuses (24.0%). Median GA and TCD were 21 weeks and 21.2 mm for Grade I; 29 weeks and 35.5 mm for Grade II; and 35 weeks and 48.1 mm for Grade III, respectively. Conclusion: The TCD increased in a linear fashion with advancing GA in the evaluated fetuses. The TCD is, therefore, a good marker for GA estimation. There is a gradual ultrasonographic change in fetal cerebellar appearance with advancing gestation.

19.
Clin Ophthalmol ; 18: 1117-1124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38686014

RESUMEN

Purpose: To evaluate postoperative outcomes after implantation of toric intraocular lenses (IOLs) made of high-water-content hydrophobic acrylic material in Japanese patients using a swept-source optical coherence tomography (SS-OCT) biometer integrated with a surgical guiding system. Patients and Methods: In this prospective observational study, toric IOL models CNW0T3 to CNW0T9 (Alcon) were implanted in 33 eyes of 33 patients and followed-up for one month. Powers and toric models were determined using an SS-OCT biometer ARGOS® Ver 1.5 (Alcon), and the IOLs were aligned using surgical guidance. Differences between planned and actual axis positions at the end of the surgery (misalignment) and rotations from the end of surgery to one month postoperatively were measured. Additionally, postoperative uncorrected visual acuity, refraction, and residual astigmatism were evaluated. Results: Mean and median misalignments were 2.3° (standard deviation [SD]: 1.6, 95% confidence interval [CI]: 1.7-2.9) and 2°, and those of postoperative rotation were 2.4° (SD: 2.6, 95% CI: 1.5-3.4) and 2°, respectively. Mean postoperative refraction was 0.06 D (SD: 0.62). Prediction errors within ±0.5 and ±1.0 D were 69.7% and 93.9%, respectively. Mean residual astigmatisms were 0.19 D (SD: 0.41), and mean uncorrected visual acuity was 0.00 logMAR (SD: 0.11), and 64% of the eyes scored 20/20 or better. Conclusion: Implantation of high-water-content hydrophobic acrylic toric IOLs using SS-OCT biometry integrated with a surgical guiding system effectively corrected corneal astigmatism with accurate IOL alignment in Japanese patients.

20.
Am J Ophthalmol ; 265: 213-223, 2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38621521

RESUMEN

PURPOSE: To compare agreement of corneal epithelium thickness (ET) between AS-OCT system (RTVue, Optovue) and AS-OCT/Placido topographer (MS-39, CSO) in eyes with different stages of keratoconus (KC), and to assess the repeatability of RTVue AS-OCT. DESIGN: Prospective reliability analysis. METHODS: KC eyes were classified into forme fruste KC (FFKC), mild, moderate, and severe KC. Agreement was evaluated with Bland-Altman plots and 95% limits of agreement (LoA). The repeatability of RTVue was assessed via within-subject standard deviation (Sw), test-retest variability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC). RESULTS: A total of 119 KC eyes were enrolled, with 21 being FFKC, 26 mild, 39 moderate, and 34 severe. The 95% LoA ranged between -5.9 and 4.8 µm for center epithelium thickness (CET), between -5.7 and 8.2 µm for thinnest epithelium thickness (TET). At 1-mm measuring points, the 95% LoA of superior, inferior, nasal, and temporal were -4.2 to 4.7 µm, -5.2 to 6.0 µm, -7.9 to 10.2 µm, and -11.2 to 6.0 µm. At 3-mm measuring points, the corresponding values were -2.8 to 9.3 µm, -2.0 to 13.0 µm, -4.6 to 9.6 µm, and -6.3 to 9.7 µm, indicating that the 2 instruments were not interchangeable without adjustment. Despite that the repeatability of RTVue measurements in KC patients were acceptable, repeatability decreased gradually with the peripheralization of the measurement points. CONCLUSIONS: The 2 OCT-based devices, RTVue and MS-39, do not provide interchangeable measurements of epithelium thickness in KC patients. Repeatability decreases in cases of more severe KC, emphasizing the importance of grading before clinical examination to avoid diagnostic errors.