Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Adv Clin Exp Med ; 33(9): 979-997, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38180330

RESUMEN

BACKGROUND: Rehabilitation in the anterior region requires specific conditions for success, such as the presence of papilla, emergence profile, and balance between pink and white esthetic. OBJECTIVES: This systematic review aimed to evaluate the esthetic risk associated with immediate implant placement with immediate restoration in the anterior superior area, where the facial bone plate may be absent or deficient. MATERIAL AND METHODS: The search was done in PubMed, Embase, Cochrane, Lilacs, Scopus, Scielo, and Google Scholar databases. The investigation involved clinical studies and observational studies published between January 2012 and July 2023. Studies were excluded if there was less than 12-month follow-up, no immediate restoration or facial defect, heavy smokers, or systemic disease. The risk of bias was assessed using the ROBINS-I and Modified-Cochrane RoB tools. RESULTS: Twelve studies were included in this systematic review. The thinner the facial plate, the higher the alveolus's risk of gingival recession or shrinkage. There was an increased interproximal recession when the thin phenotype was associated with flap surgery. An increase in pink esthetic score (PES) was reached when immediate implant placement (IIP) and immediate restoration were done. Soft tissue augmentation achieved more gingival-level stability. Regardless of the initial phenotype, an esthetic outcome was delivered. The risk of bias was high in 1 study and moderate in 3 studies. CONCLUSION: It is possible to conclude that esthetic results and increased final PES or patient satisfaction index in IIP treatments associated with immediate restoration could be obtained even in buccal bone wall defects or gingival recession, regardless of their extension.


Asunto(s)
Estética Dental , Carga Inmediata del Implante Dental , Humanos , Huesos Faciales/cirugía , Carga Inmediata del Implante Dental/métodos
2.
Arq. bras. med. vet. zootec. (Online) ; 74(5): 948-953, Sep.-Oct. 2022. tab, ilus
Artículo en Inglés | VETINDEX | ID: biblio-1403408

RESUMEN

The aim of this study was to develop a modified tibial plateau leveling osteotomy (TPLO) plate and to compare its biomechanical properties with a locking compression plate (LCP) and plate-rod constructs for the stabilization of experimentally induced gap fractures in canine synthetic tibias. The tibial models were assigned to either repair with a modified TPLO plate (Group 1), locking compression plate construct (Group 2), or plate-rod construct (Group 3). The specimens were loaded to failure in axial compression, three-point mediolateral and craniocaudal bending. There was no statistical difference between the three groups regarding stiffness (N/mm) and deformation (mm) in axial compression. The modified TPLO plate achieved load to failure similar to the plate-rod construct in craniocaudal bending. There was no significant difference between groups on mediolateral bending tests regarding load to failure and deformation. Furthermore, there was no significant difference in stiffness between groups 1 and 2. In conclusion, the modified TPLO plate had similar mechanical properties to LCP and plate-rod construct in the axial compression and bending tests. Nonetheless, clinical studies with a large population of dogs are required to determine the value of this new implant in proximal tibial fracture repair.


Objetivou-se desenvolver uma placa de osteotomia niveladora do platô tibial (TPLO) modificada e compará-la biomecanicamente à placa de compressão bloqueada (LCP) e à construção placa-pino intramedular na estabilização da fratura cominutiva proximal em tíbias sintéticas caninas. Para tal, tíbias caninas sintéticas foram divididas em três grupos, sendo o grupo 1 formado pela placa de TPLO modificada, o grupo 2 por placas LCP e o grupo 3 pela construção placa-pino intramedular. Os espécimes foram submetidos à carga até a falha em compressão axial, flexão mediolateral e craniocaudal em três pontos. Não houve diferença estatística entre os três grupos quanto à rigidez (N/mm) e à deformação (mm) nos testes de compressão axial. A placa de TPLO modificada obteve carga até a falha semelhante à construção placa-pino intramedular em flexão craniocaudal. Não houve diferença significativa entre os grupos nos testes de flexão mediolateral em relação à carga até a falha e a deformação, e a variável rigidez não apresentou diferenças significativas entre os grupos 1 e 2. Em conclusão, a placa de TPLO modificada apresentou similaridade mecânica em comparação com a LCP e a construção placa-pino. No entanto, estudos clínicos são necessários para determinar o valor desse novo implante na fixação de fraturas tibiais proximais.


Asunto(s)
Osteotomía/veterinaria , Fracturas de la Tibia/cirugía , Placas Óseas/veterinaria , Fenómenos Biomecánicos
3.
Acta Ortop Bras ; 27(6): 288-293, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31798317

RESUMEN

OBJECTIVE: This study compared groups of patients with calcaneal fractures of Sanders types II and III. One group was treated with ORIF using an LCP (plate), while the second was treated with a minimally invasive method using a C-Nail. METHODS: The study included 217 patients in the ORIF group and 19 patients in the minimally invasive nail osteosynthesis group. RESULTS: In the LCP group, the outcomes were excellent for 35.7% of the patients; good, 38.9%; satisfactory, 19.7%; and poor, 5.7%. In the C-Nail group, the outcomes were excellent for 36.9% of the patients; good; 31.6%; satisfactory, 21%; and poor, 10.2%. The mean values of the restoration of Böhler's angle from post-injury were 6.8° to 32.3° in the LCP group and 7.1° to 33.3° in the C-Nail group. After 12 months, there was only a minimal decrease in Böhler's angle to 29.2° in both the LCP and C-Nail groups. CONCLUSION: The outcomes obtained with C-Nail fixation are statistically identical to those obtained with LCP fixation. We conclude that osteosynthesis with a C-Nail is suitable as the first-choice treatment for Sanders types II and III fractures. Level of evidence IV, retrospective observational study.


OBJETIVO: Comparar grupos de pacientes com fratura intra-articular do calcâneo tipos II e III de Sanders. MÉTODOS: Estudo retrospectivo que incluiu 217 pacientes no grupo tratado por redução aberta e fixação interna com placa de compressão (Grupo PC) e 19 pacientes que seguiram um método minimamente invasivo com C-Nail. RESULTADOS: No Grupo PC, os resultados foram excelentes em 35,7%, bons em 38,9%, satisfatórios em 19,17% e ruins em 5,7%. Os resultados registados no grupo que recebeu implante de unha foram excelentes em 36,9%, bons em 31,6%, satisfatórios em 21% e ruins em 10,2% Os valores médios do restauro do ângulo de Böhler desde o pós-ferimento variaram entre 6,8° e 32,3°, no Grupo PC, e entre 7,1° e 33,3°, no grupo tratado com C-Nail. Ao fim de 12 meses, apenas se observou redução mínima do ângulo de Böhler para 29,2° nos dois grupos. CONCLUSÃO: Os resultados do método recentemente introduzido de osteossíntese minimamente invasiva com C-Nail são estatisticamente idênticos aos obtidos pela redução aberta e fixação interna com placa de compressão. Assim, o novo tipo de osteossíntese com C-Nail é adequado como primeira escolha em fraturas do tipo Sanders II e III. Nível de evidência IV, Estudo retrospectivo de observação.

4.
Nosso clínico ; 22(132): 26-30, nov.-dez. 2019. ilus
Artículo en Portugués | VETINDEX | ID: biblio-1486151

RESUMEN

As fraturas do terço distal de rádio e ulna apresentam uma alta incidência na rotina ortopédica veterinária, principalmente em cães de pequeno porte. Frequentemente são encontradas dificuldades na reparação dessas, como a não união ou união retardada, tornando-se ainda mais desafiadoras quando acometidas bilateralmente. Neste relato, foi atendido um cão de pequeno porte com fratura bilateral completa transversa distal de rádio e ulna sendo reparada por redução aberta e fixação com placa bloqueada na face cranial do rádio associada ao enxerto β-TCP. Essa técnica proporcionou estabilidade satisfatória, rápido retorno à função dos membros e tempo favorável de consolidação óssea, concluindo-se ser efetiva na reparação dessas fraturas.


The distal third of radius and ulna fractures are highly frequent in the veterinary orthopedics routine, mainly in small breed dogs. There are often difficulties in repair which may result in non union or delayed union. Healing becomes even more challenging in case of bilateral distal radius and ulna fractures. This case reports a complete transverse bilateral distal radius and ulna fracture in a small breed dog. The treatment consists of open reduction and cranial locking bone plate fixation on the radius associated with β-TCP bone graft. This technique promoted satisfactory stabilization, rapid function return and favorable time of bone consolidation, implying that this procedure ís effective in healing the analyzed fracture types.


Las fracturas dei tercio distal de radio y ulna presentan una alta incidencia en la rutina ortopédica veterinária, principalmente en perros de porte pequeno. Frecuentemente son encontradas dificultades en sus reparaciones, como la no unión o unión retardada, haciéndose aún más desafiadora cuando acometidas bilateralmente. En este relato, fue atendido un perro de pequeno porte con fractura bilateral completa transversa distal de radio y ulna siendo corregida por reducción abierta y fijación con placa bloqueada en la faz craneal del radio asociada ai injerto β-TCP. Esta técnica proporcionó estabilidad satisfactoria, rápido retorno a Ia función de los miembros y tiempo favorable de consolidación ósea, concluyéndose ser efectiva en la reparación de estas fracturas.


Asunto(s)
Masculino , Animales , Perros , Fijación Interna de Fracturas/métodos , Fracturas del Cúbito/rehabilitación , Radio (Anatomía)/lesiones , Sustitutos de Huesos/uso terapéutico , Fijación Interna de Fracturas/veterinaria , Placas Óseas
5.
Nosso Clín. ; 22(132): 26-30, nov.-dez. 2019. ilus
Artículo en Portugués | VETINDEX | ID: vti-26978

RESUMEN

As fraturas do terço distal de rádio e ulna apresentam uma alta incidência na rotina ortopédica veterinária, principalmente em cães de pequeno porte. Frequentemente são encontradas dificuldades na reparação dessas, como a não união ou união retardada, tornando-se ainda mais desafiadoras quando acometidas bilateralmente. Neste relato, foi atendido um cão de pequeno porte com fratura bilateral completa transversa distal de rádio e ulna sendo reparada por redução aberta e fixação com placa bloqueada na face cranial do rádio associada ao enxerto β-TCP. Essa técnica proporcionou estabilidade satisfatória, rápido retorno à função dos membros e tempo favorável de consolidação óssea, concluindo-se ser efetiva na reparação dessas fraturas.(AU)


The distal third of radius and ulna fractures are highly frequent in the veterinary orthopedics routine, mainly in small breed dogs. There are often difficulties in repair which may result in non union or delayed union. Healing becomes even more challenging in case of bilateral distal radius and ulna fractures. This case reports a complete transverse bilateral distal radius and ulna fracture in a small breed dog. The treatment consists of open reduction and cranial locking bone plate fixation on the radius associated with β-TCP bone graft. This technique promoted satisfactory stabilization, rapid function return and favorable time of bone consolidation, implying that this procedure ís effective in healing the analyzed fracture types.(AU)


Las fracturas dei tercio distal de radio y ulna presentan una alta incidencia en la rutina ortopédica veterinária, principalmente en perros de porte pequeno. Frecuentemente son encontradas dificultades en sus reparaciones, como la no unión o unión retardada, haciéndose aún más desafiadora cuando acometidas bilateralmente. En este relato, fue atendido un perro de pequeno porte con fractura bilateral completa transversa distal de radio y ulna siendo corregida por reducción abierta y fijación con placa bloqueada en la faz craneal del radio asociada ai injerto β-TCP. Esta técnica proporcionó estabilidad satisfactoria, rápido retorno a Ia función de los miembros y tiempo favorable de consolidación ósea, concluyéndose ser efectiva en la reparación de estas fracturas.(AU)


Asunto(s)
Animales , Masculino , Perros , Fijación Interna de Fracturas/métodos , Fracturas del Cúbito/rehabilitación , Radio (Anatomía)/lesiones , Sustitutos de Huesos/uso terapéutico , Fijación Interna de Fracturas/veterinaria , Placas Óseas
6.
Acta ortop. bras ; Acta ortop. bras;27(6): 288-293, Nov.-Dec. 2019. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1038184

RESUMEN

ABSTRACT Objective: This study compared groups of patients with calcaneal fractures of Sanders types II and III. One group was treated with ORIF using an LCP (plate), while the second was treated with a minimally invasive method using a C-Nail. Methods: The study included 217 patients in the ORIF group and 19 patients in the minimally invasive nail osteosynthesis group. Results: In the LCP group, the outcomes were excellent for 35.7% of the patients; good, 38.9%; satisfactory, 19.7%; and poor, 5.7%. In the C-Nail group, the outcomes were excellent for 36.9% of the patients; good; 31.6%; satisfactory, 21%; and poor, 10.2%. The mean values of the restoration of Böhler's angle from post-injury were 6.8° to 32.3° in the LCP group and 7.1° to 33.3° in the C-Nail group. After 12 months, there was only a minimal decrease in Böhler's angle to 29.2° in both the LCP and C-Nail groups. Conclusion: The outcomes obtained with C-Nail fixation are statistically identical to those obtained with LCP fixation. We conclude that osteosynthesis with a C-Nail is suitable as the first-choice treatment for Sanders types II and III fractures. Level of evidence IV, retrospective observational study.


RESUMO Objetivo: Comparar grupos de pacientes com fratura intra-articular do calcâneo tipos II e III de Sanders. Métodos: Estudo retrospectivo que incluiu 217 pacientes no grupo tratado por redução aberta e fixação interna com placa de compressão (Grupo PC) e 19 pacientes que seguiram um método minimamente invasivo com C-Nail. Resultados: No Grupo PC, os resultados foram excelentes em 35,7%, bons em 38,9%, satisfatórios em 19,17% e ruins em 5,7%. Os resultados registados no grupo que recebeu implante de unha foram excelentes em 36,9%, bons em 31,6%, satisfatórios em 21% e ruins em 10,2% Os valores médios do restauro do ângulo de Böhler desde o pós-ferimento variaram entre 6,8° e 32,3°, no Grupo PC, e entre 7,1° e 33,3°, no grupo tratado com C-Nail. Ao fim de 12 meses, apenas se observou redução mínima do ângulo de Böhler para 29,2° nos dois grupos. Conclusão: Os resultados do método recentemente introduzido de osteossíntese minimamente invasiva com C-Nail são estatisticamente idênticos aos obtidos pela redução aberta e fixação interna com placa de compressão. Assim, o novo tipo de osteossíntese com C-Nail é adequado como primeira escolha em fraturas do tipo Sanders II e III. Nível de evidência IV, Estudo retrospectivo de observação.

7.
Int. j. morphol ; 37(3): 1079-1084, Sept. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1012399

RESUMEN

The maxillary sinus floor location and the buccal bone plate are factors to be considered in the long-term success with implant treatments mainly in the premolar region. the aim of this study was to establish morphometric characteristics of the buccal cortical bone (BCB) thickness of maxillary premolars and its relation to maxillary sinus floor through CBCT. In this study 350 first and second maxillary premolars were analyzed from 110 CBCT images and the buccal cortical bone (BCB) was measured in a coronal view at the major axis level of each premolar. In addition, in 200 first and second maxillary premolars CBCT images were measured the distance from premolar apex to maxillary sinus floor (MSF) in both frontal and sagittal plane. The type of relationship between the apex and MSF was classified according to Ok et al. (2014). The second premolar was observed with higher values of BCB (p<0.001). In first premolar, higher values were observed in the male sex (p>0.05). In second premolar, only significantly higher values were observed in the male sex in MA-MB-MC (p>0.05). Regarding to MSF and its relation to premolar roots, it was observed that 10 % of the sample was classified as type I, 19 % as type II, 55.5 % as type III and 15.5 % as type IV. The BCB of the upper premolar region is thicker in the apical region and decreases toward the coronal region. Almost 50 % of apex of second premolars are closely and risky related MSF (Type I and II).


La localización del piso del seno maxilar (PSM) y la tabla ósea vestibular (TOV) son factores a considerar en el éxito a largo plazo de los tratamientos de implante dental en la región premolar. El objetivo de este estudio fue establecer características morfométricas del grosor de la TOV en los premolares maxilares y su relación con el PSM a través de CBCT. Se analizaron 350 primeros y segundos premolares en 110 CBCT y la TOV fue medida en vista coronal en el eje axial mayor de cada premolar. Además en 200 primeros y segundos premolares maxilares se midió la distancia desde el ápice del diente hasta el PSM en el plano sagital y frontal. El tipo de relación entre el ápice y el PSM se clasificó según Ok et al. (2014). El Segundo premolar obtuvo los mayores valores de grosor de TOV (p<0.001). En primeros premolares se observaron valores altos en el género masculino (p>0.05). En segundos premolares solo se encontraron valores significativamente altos en el género masculino en MA-MB-MC (p>0.05). En la relación con el PSM y ápices de raíces de premolares, el 10% de la muestra se clasificó como tipo I, el 19% como tipo II, el 55,5% como tipo III y el 15.5% como tipo IV. En conclusión la TOV de la región premolares superior es más grueso en la zona apical, decreciendo hacia la zona coronal. Alrededor del 50% de los ápices de raíces de premolares maxilares están cercanas y en relación de riesgo con el PSM (tipo I y II).


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Adulto Joven , Diente Premolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Seno Maxilar/diagnóstico por imagen , Tamaño de los Órganos , Diente Premolar/anatomía & histología , Estudios Transversales , Seno Maxilar/anatomía & histología
8.
Acta Ortop Bras ; 27(2): 80-84, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30988651

RESUMEN

OBJECTIVE: To postoperatively evaluate knee scores, radiological assessment results, deficit correction, patellar height change, bone healing time, and weight bearing time in patients undergoing high tibial osteotomy (HTO) with/without autologous iliac bone grafting. METHODS: This retrospective examination of treated controls from a randomized controlled study included 63 knees of 58 patients aged 46-59 years who underwent HTO with locking open wedge osteotomy plates. The patients were divided into two groups: Group A, HTO with autologous iliac bone grafts (n = 31); and Group B, HTO without autologous iliac bone grafts (n = 32). Clinical and radiological data were evaluated prospectively at the preoperative consultation and again at 6, 9, and 12 weeks, 6 months, and 1 year after the surgery (and annually thereafter). RESULTS: There were no significant intergroup differences in the radiological assessment, deficit correction, patellar height change, bone-healing time, and weight-bearing time at any time after surgery. The knee scores changed positively in both groups (p < 0.001). CONCLUSIONS: There was no difference in the results of patients undergoing HTO with open wedge osteotomy titanium locking plates with or without autografting, and comorbidities resulting from autografts were eliminated with the use of locking plates. Level of evidence III, Retrospective Study .


OBJETIVO: Avaliar escores de joelho, resultados da avaliação radiológica, correção de déficits, alteração da altura patelar, tempo de consolidação óssea e tempo para apoio de peso no pós-operatório em pacientes submetidos à osteotomia tibial alta (OTA) com ou sem enxerto autólogo de osso ilíaco. MÉTODOS: O exame retrospectivo de controles tratados em estudo randomizado e controlado foi realizado em 63 joelhos de 58 pacientes com idade entre 46 e 59 anos submetidos a OTA com placas bloqueadas de titânio em cunha aberta. Os pacientes foram divididos em dois grupos: Grupo A, OTA com enxerto de osso ilíaco autólogo (n = 31) e Grupo B, OTA sem enxerto autólogo de osso ilíaco (n = 32). Os dados clínicos e radiológicos foram avaliados prospectivamente na consulta pré-operatória e 6, 9 e 12 semanas e 6 meses e 1 ano após a cirurgia (e depois disso, anualmente). RESULTADOS: Não houve diferenças significativas quanto a avaliação radiológica, correção de déficit, mudança de altura da patela, tempo de cicatrização óssea e tempo para apoio de peso entre os dois grupos em nenhum momento após a cirurgia. Os escores de joelho mudaram positivamente em ambos os grupos (p < 0,001). CONCLUSÕES: Não houve diferença nos resultados dos pacientes submetidos a OTA com placas bloqueadas de titânio em cunha aberta com e sem autoenxerto, e as comorbidades resultantes dos autoenxertos foram eliminadas com o uso de placas bloqueadas. Nível de Evidência III, Estudo Retrospectivo.

9.
Acta ortop. bras ; Acta ortop. bras;27(2): 80-84, Mar.-Apr. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-989205

RESUMEN

ABSTRACT Objective: To postoperatively evaluate knee scores, radiological assessment results, deficit correction, patellar height change, bone healing time, and weight bearing time in patients undergoing high tibial osteotomy (HTO) with/without autologous iliac bone grafting. Methods: This retrospective examination of treated controls from a randomized controlled study included 63 knees of 58 patients aged 46-59 years who underwent HTO with locking open wedge osteotomy plates. The patients were divided into two groups: Group A, HTO with autologous iliac bone grafts (n = 31); and Group B, HTO without autologous iliac bone grafts (n = 32). Clinical and radiological data were evaluated prospectively at the preoperative consultation and again at 6, 9, and 12 weeks, 6 months, and 1 year after the surgery (and annually thereafter). Results: There were no significant intergroup differences in the radiological assessment, deficit correction, patellar height change, bone-healing time, and weight-bearing time at any time after surgery. The knee scores changed positively in both groups (p < 0.001). Conclusions: There was no difference in the results of patients undergoing HTO with open wedge osteotomy titanium locking plates with or without autografting, and comorbidities resulting from autografts were eliminated with the use of locking plates. Level of evidence III, Retrospective Study.


RESUMO Objetivo: Avaliar escores de joelho, resultados da avaliação radiológica, correção de déficits, alteração da altura patelar, tempo de consolidação óssea e tempo para apoio de peso no pós-operatório em pacientes submetidos à osteotomia tibial alta (OTA) com ou sem enxerto autólogo de osso ilíaco. Métodos: O exame retrospectivo de controles tratados em estudo randomizado e controlado foi realizado em 63 joelhos de 58 pacientes com idade entre 46 e 59 anos submetidos a OTA com placas bloqueadas de titânio em cunha aberta. Os pacientes foram divididos em dois grupos: Grupo A, OTA com enxerto de osso ilíaco autólogo (n = 31) e Grupo B, OTA sem enxerto autólogo de osso ilíaco (n = 32). Os dados clínicos e radiológicos foram avaliados prospectivamente na consulta pré-operatória e 6, 9 e 12 semanas e 6 meses e 1 ano após a cirurgia (e depois disso, anualmente). Resultados: Não houve diferenças significativas quanto a avaliação radiológica, correção de déficit, mudança de altura da patela, tempo de cicatrização óssea e tempo para apoio de peso entre os dois grupos em nenhum momento após a cirurgia. Os escores de joelho mudaram positivamente em ambos os grupos (p < 0,001). Conclusões: Não houve diferença nos resultados dos pacientes submetidos a OTA com placas bloqueadas de titânio em cunha aberta com e sem autoenxerto, e as comorbidades resultantes dos autoenxertos foram eliminadas com o uso de placas bloqueadas. Nível de Evidência III, Estudo Retrospectivo.

10.
Coluna/Columna ; 17(3): 188-194, July-Sept. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-952941

RESUMEN

ABSTRACT Objective: The aim of the study was to investigate the clinical and radiological results of using the annular closure device in patients with lumbar disc herniation (LDH). Methods: The study involved 120 patients with LDH operated on by limited discectomy and annular closure using the Barricaid device. A literature review was conducted to evaluate the effectiveness of the annuloplasty. Results: All patients showed postoperative regression of the radicular pain syndrome and were mobilized on the day of surgery. The correlation between the removed nucleus pulposus and changes in DHI was studied by linear regression. The results revealed that disc height loss is directly correlated with the volume of removed nucleus pulposus (p <0.05). Modic changes were present in 22 (22%) patients. Endplate changes (resorption and erosion) were present in 25 patients (20.7%). We found that these changes in MR and CT images have no effect on the clinical presentation of the disease. No intraoperative complications, such as severe hemorrhage requiring blood transfusion, or injury to the dura mater or nerve roots, were observed in our case series. Postoperative complications occurred in 3 (2.5%) patients. The reoperation rate was 4.2%. Conclusions: The use of the Barricaid annular closure device in 120 patients with lumbar disc herniation and high risk of recurrent herniation showed good clinical and radiographic outcomes. The reoperation rate in our study was 2.5%; disc reherniation at the operated level was observed in 1.7% of patients. This is a good outcome compared to the data reported for patients having a high risk of disc reherniation. Level of Evidence IV; Case series.


RESUMO Objetivo: O objetivo do estudo foi estudar os resultados clínicos e radiológicos do uso do dispositivo de fechamento anular em pacientes com hérnia discal lombar (HDL). Métodos: O estudo envolveu 120 pacientes com LDH operados por discectomia limitada e fechamento anular usando o dispositivo Barricaid. Uma revisão da literatura foi realizada para avaliar a eficácia da anuloplastia. Resultados: Todos os pacientes apresentaram regressão pós-operatória da síndrome da dor radicular e foram mobilizados no dia da cirurgia. A correlação entre o núcleo pulposo removido e as alterações no DHI foi estudada por regressão linear. Revelou-se que a perda de altura discal está diretamente correlacionada com o volume do núcleo pulposo removido (p <0,05). Alterações modicadas reveladas em 22 (22%) pacientes. As alterações no endplate foram reveladas em 25 pacientes (20,7%). Descobrimos que essas mudanças nas imagens de RM e TC não têm efeito sobre a apresentação clínica da doença. Não foram observadas complicações intraoperatórias, como hemorragia grave que necessitou de transfusão sanguínea, lesão da dura-máter ou raízes nervosas, em nossa casuística. Complicações pós-operatórias foram reveladas em 3 (2,5%) pacientes. A taxa de reoperação foi de 4,2%. Conclusão: O uso do dispositivo de fechamento anular Barricaid em 120 pacientes com hérnia discal lombar e alto risco de hérnia recorrente mostrou bons resultados clínicos e radiográficos. A taxa de reoperação em nosso estudo foi de 2,5%; reinteriato discal no nível operado foi observado em 1,7% dos pacientes. É um bom resultado comparado aos dados relatados para pacientes com alto risco de reintervenção com disco. Nível de evidência IV; Série de casos.


RESUMEN Objetivo: El objetivo del estudio fue estudiar los resultados clínicos y radiológicos del uso del dispositivo de cierre anular en pacientes con hernia de disco lumbar (LDH). Métodos: El estudio involucró a 120 pacientes con LDH operados por discectomía limitada y cierre anular usando el dispositivo Barricaid. Se realizó una revisión de la literatura para evaluar la efectividad de la anuloplastia. Resultados: Todos los pacientes mostraron regresión postoperatoria del síndrome de dolor radicular y se movilizaron el día de la cirugía. La correlación entre el núcleo pulposo retirado y los cambios en DHI se estudiaron mediante regresión lineal. Los resultados revelaron que la pérdida de altura del disco se correlaciona directamente con el volumen del núcleo pulposo retirado (p <0,05). Cambios módicos revelados en 22 (22%) pacientes. Los cambios de placa terminal (resorción y erosión) se revelaron en 25 pacientes (20,7%). Descubrimos que estos cambios en las imágenes de RM y TC no tienen ningún efecto sobre la presentación clínica de la enfermedad. En nuestra serie de casos no se observaron complicaciones intraoperatorias, como hemorragia severa que requiriera transfusión de sangre, lesión de la duramadre o raíces nerviosas. Las complicaciones postoperatorias se revelaron en 3 (2,5%) pacientes. La tasa de reoperación fue del 4,2%. Conclusiones: El uso del dispositivo de cierre anular Barricaid en 120 pacientes con hernia de disco lumbar y alto riesgo de hernia recurrente mostró buenos resultados clínicos y radiográficos. La tasa de reoperación en nuestro estudio fue del 2.5%; la hernia recurrente del disco en el nivel operado se observó en el 1,7% de pacientes. Es un buen resultado en comparación con los datos informados para pacientes que tienen un alto riesgo de hernia recurrente del disco. Nivel de evidencia IV; Serie de casos.


Asunto(s)
Humanos , Anillo Fibroso , Columna Vertebral/cirugía , Discectomía , Desplazamiento del Disco Intervertebral
11.
Braz. j. otorhinolaryngol. (Impr.) ; Braz. j. otorhinolaryngol. (Impr.);84(2): 212-219, Mar.-Apr. 2018. graf
Artículo en Inglés | LILACS | ID: biblio-889376

RESUMEN

Abstract Introduction Traditional Caldwell-Luc approach needs modifications for odontogenic cysts intruding into the maxillary sinus, to preserve sinus mucosa and bony contour. Recently, digital technology has been widely applied to the field of maxillofacial surgery, guiding the surgical plan and improving its accuracy. Objective This study attempted to present and evaluate the functional surgery of odontogenic cysts intruding into the maxillary sinus using a computer-assisted pre-surgical design. Methods Consecutive patients with odontogenic cysts intruding into the posterior part of the maxillary sinus were enrolled. Method I "Bony wall reimplantation method" was performed for large lesions exceeding the zygomatic alveolar crest but without apparent bone destruction of the anterior wall of the sinus, while Method II "bone removal method" was more convenient for small lesions near to the zygomatic alveolar crest. The gap was filled with a pedicled buccal fat pad after lesion removal and all cases were without inferior meatal antrostomy. Results A total of 45 cases were included in the study. 22 were operated using method I while 23 were operated with method II. Operations were completed in 20 min. Pain disappeared in 3.62 days on average, and swelling 6.47 days. Nasal bleeding occurred in 8 patients lasting 1-3 days. Suppurative inflammation was observed in 1 patient, and infection occurred after bone reposition. Other repositioned free bony wall was without resorption in CT images. Conclusions Sinus mucosa and bony wall should be conserved. Preoperative digital design can guide osteotomy effectively during the surgery. Bone reposition is not suitable for suppurative inflammation. The pedicled buccal fat pad is enough for drainage and inferior meatal antrostomy is not necessary.


Resumo Introdução A abordagem tradicional de Caldwell-Luc precisa de modificações para os cistos odontogênicos que se introduzem no seio maxilar, para preservar a mucosa sinusal e o contorno ósseo. Recentemente, a tecnologia digital tem sido amplamente aplicada ao campo da cirurgia maxilofacial, orienta o plano cirúrgico e melhora sua precisão. Objetivo Esse estudo teve como objetivo apresentar e avaliar a cirurgia funcional de cistos odontogênicos intrusivos no seio maxilar utilizando um desenho pré-cirúrgico assistido por computador. Método Foram recrutados pacientes consecutivos com cistos odontogênicos intrusivos na parte posterior do seio maxilar. O método I, "método de reimplante de parede óssea", foi feito em lesões grandes que excediam a crista zigomático-alveolar, mas sem destruição óssea aparente da parede anterior do seio, enquanto o método II, "método de remoção óssea", foi mais conveniente para pequenas lesões próximas à crista zigomático-alveolar. O espaço foi preenchido com um retalho pediculado do corpo adiposo bucal após a remoção da lesão e todos os casos foram feitos sem antrostomia meatal inferior. Resultados Um total de 45 casos foram incluídos no estudo. Vinte e dois foram submetidos à cirurgia utilizando-se o método I, enquanto que 23 foram submetidos ao método II. As operações foram concluídas em 20 minutos. A dor desapareceu em média após 3,62 dias, e o edema, depois de 6,47 dias. Hemorragia nasal ocorreu em 8 pacientes com duração de 1 a 3 dias. Processo supurativa foi observado em 1 paciente ocorrendo após a reposição óssea. Outros retalhos reposicionados livres da parede óssea não mostraram reabsorção em imagens de TC. Conclusões A mucosa sinusal e a parede óssea devem ser preservadas; o desenho digital pré-operatório pode orientar a osteotomia de forma eficaz durante a cirurgia; a reposição óssea não é adequada em processos supurativos. O retalho pediculado de corpo adiposo bucal é suficiente para a drenagem e antrostomia meatal inferior não é necessária.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Adulto Joven , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Colgajos Quirúrgicos , Placas Óseas , Enfermedades Maxilares/cirugía , Quistes Odontogénicos/cirugía , Seno Maxilar/cirugía , Enfermedades Maxilares/diagnóstico por imagen , Quistes Odontogénicos/diagnóstico por imagen , Diseño Asistido por Computadora , Seno Maxilar/diagnóstico por imagen
12.
Braz J Otorhinolaryngol ; 84(2): 212-219, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-28479048

RESUMEN

INTRODUCTION: Traditional Caldwell-Luc approach needs modifications for odontogenic cysts intruding into the maxillary sinus, to preserve sinus mucosa and bony contour. Recently, digital technology has been widely applied to the field of maxillofacial surgery, guiding the surgical plan and improving its accuracy. OBJECTIVE: This study attempted to present and evaluate the functional surgery of odontogenic cysts intruding into the maxillary sinus using a computer-assisted pre-surgical design. METHODS: Consecutive patients with odontogenic cysts intruding into the posterior part of the maxillary sinus were enrolled. Method I "Bony wall reimplantation method" was performed for large lesions exceeding the zygomatic alveolar crest but without apparent bone destruction of the anterior wall of the sinus, while Method II "bone removal method" was more convenient for small lesions near to the zygomatic alveolar crest. The gap was filled with a pedicled buccal fat pad after lesion removal and all cases were without inferior meatal antrostomy. RESULTS: A total of 45 cases were included in the study. 22 were operated using method I while 23 were operated with method II. Operations were completed in 20min. Pain disappeared in 3.62 days on average, and swelling 6.47 days. Nasal bleeding occurred in 8 patients lasting 1-3 days. Suppurative inflammation was observed in 1 patient, and infection occurred after bone reposition. Other repositioned free bony wall was without resorption in CT images. CONCLUSIONS: Sinus mucosa and bony wall should be conserved. Preoperative digital design can guide osteotomy effectively during the surgery. Bone reposition is not suitable for suppurative inflammation. The pedicled buccal fat pad is enough for drainage and inferior meatal antrostomy is not necessary.


Asunto(s)
Placas Óseas , Enfermedades Maxilares/cirugía , Seno Maxilar/cirugía , Quistes Odontogénicos/cirugía , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Colgajos Quirúrgicos , Adolescente , Adulto , Anciano , Diseño Asistido por Computadora , Femenino , Humanos , Masculino , Enfermedades Maxilares/diagnóstico por imagen , Seno Maxilar/diagnóstico por imagen , Persona de Mediana Edad , Quistes Odontogénicos/diagnóstico por imagen , Adulto Joven
13.
Cranio ; 36(4): 234-242, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28553749

RESUMEN

OBJECTIVE: This retrospective study evaluated the use of a single miniplate for the treatment of mandibular angle fractures (MAF). METHODS: Fifty patients with 53 MAF were treated by open reduction and internal fixation with the use of a single miniplate and were analyzed in this study. RESULTS: Five patients with MAF had postoperative complications that required additional procedures. Three patients had postoperative infection, one patient complained of malocclusion in the first postoperative week, and one patient had miniplate exposure three months after surgery. Every additional procedure was performed in the office under local anesthesia without disruption of the initial fracture treatment. Postoperative maxillomandibular fixation (MMF) was performed in four patients. Treatment of MAF using a single miniplate was effective, with low morbidity and with low rates of postoperative complications. MAF can be treated without MMF, and stability is improved when long miniplates are used. CONCLUSIONS: The use of a single miniplate is therefore encouraged. However, postoperative MMF should be considered with the presence of little contact between bone segments, malocclusion, or extensive tooth loss.


Asunto(s)
Placas Óseas , Técnicas de Fijación de Maxilares/instrumentación , Fracturas Mandibulares/cirugía , Adolescente , Adulto , Femenino , Estudios de Seguimiento , Fijación Interna de Fracturas , Curación de Fractura , Humanos , Masculino , Mandíbula/diagnóstico por imagen , Fracturas Mandibulares/diagnóstico por imagen , Persona de Mediana Edad , Radiografía Dental , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
14.
Acta Vet. Brasilica ; 11(2): 124-128, jun. 2017. ilus
Artículo en Inglés | VETINDEX | ID: biblio-1453094

RESUMEN

The purpose of this study was to describe a pantarsal arthrodesis using a medial locking plate in an overweight dog. A 5-year-old, 28 kg, female dachshund presented with a left plantigraded hindlimb with calcaneous osteolytic injury and bone exposure. First, the patient was treated for the skin wound and started on a weight-loss program. A customized locking plate was used in the pantarsal arthrodesis. A normal hindlimb position and gait were observed after 27 days, and bone fusion was achieved at 60 days postoperatively. Implant removal was performed at 120 days, and the patient was discharged. The dog was kept on weight-loss therapy until it achieved a body weight of 11 kg. The customized bone implant used for pantarsal arthrodesis proved feasible and effective in treating an obese dog with low bone density.


Asunto(s)
Animales , Perros , Artrodesis/veterinaria , Placas Óseas/veterinaria , Resorción Ósea/terapia , Resorción Ósea/veterinaria , Tarso Animal/cirugía , Obesidad
15.
Acta Vet. bras. ; 11(2): 124-128, jun. 2017. ilus
Artículo en Inglés | VETINDEX | ID: vti-16378

RESUMEN

The purpose of this study was to describe a pantarsal arthrodesis using a medial locking plate in an overweight dog. A 5-year-old, 28 kg, female dachshund presented with a left plantigraded hindlimb with calcaneous osteolytic injury and bone exposure. First, the patient was treated for the skin wound and started on a weight-loss program. A customized locking plate was used in the pantarsal arthrodesis. A normal hindlimb position and gait were observed after 27 days, and bone fusion was achieved at 60 days postoperatively. Implant removal was performed at 120 days, and the patient was discharged. The dog was kept on weight-loss therapy until it achieved a body weight of 11 kg. The customized bone implant used for pantarsal arthrodesis proved feasible and effective in treating an obese dog with low bone density.(AU)


Asunto(s)
Animales , Perros , Artrodesis/veterinaria , Tarso Animal/cirugía , Placas Óseas/veterinaria , Resorción Ósea/terapia , Resorción Ósea/veterinaria , Obesidad
16.
Pesqui. vet. bras ; Pesqui. vet. bras;37(5): 495-501, maio 2017. tab, ilus
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-895445

RESUMEN

This study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone-plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.(AU)


O objetivo deste estudo foi desenvolver uma placa bloqueada em formato de T e avaliar as propriedades mecânicas em um modelo sintético. Uma placa-T em liga de titânio 2,7mm foi desenhada com uma haste contendo três orifícios para parafusos bloqueados e um orifício para realização de compressão dinâmica. 40 blocos de poliuretano em formato de T e 20 placas-T foram utilizados para os ensaios mecânicos. Seis montagens osso-placa foram testados até a falha, sendo três em força de compressão axial e três em flexão engastada. 14 montagens osso-placa foram testadas até a falha em fatiga, sendo 7 em força de compressão axial e 7 em flexão engastada. No teste estático, os valores mais altos foram observados em todas as variáveis no teste de compressão axial quando comparado à flexão engastada. Já nos testes de fadiga na força de compressão axial, todas as montagens osso-placa resistiram à 1000000 de ciclos. No teste de fadiga em flexão engastada, quatro montagens osso-placa falharam antes de alcançarem 1000000 de ciclos. Em conclusão, a placa-T estudada apresenta propriedades mecânicas que oferecem uma melhor resistência em estabilizar as fraturas na atuação das forças de compressão axial que nas forças de flexão.(AU)


Asunto(s)
Titanio , Placas Óseas , Soporte de Peso , Fenómenos Mecánicos , Prótesis e Implantes
17.
Pesqui. vet. bras ; 37(5): 495-501, maio 2017. ilus, tab
Artículo en Inglés | VETINDEX | ID: vti-734757

RESUMEN

This study aimed to develop a locking T-plate and to evaluate its mechanical properties in synthetic models. A titanium 2.7mm T-plate was designed with a shaft containing three locked screw holes and one dynamic compression hole, and a head with two locked screw holes. Forty T-shaped polyurethane blocks, and 20 T-plates were used for mechanical testing. Six bone-plate constructs were tested to failure, three in axial compression and three in cantilever bending. Fourteen bone-plate constructs were tested for failure in fatigue, seven in axial compression and seven in cantilever bending. In static testing higher values of axial compression test than cantilever bending test were observed for all variables. In axial compression fatigue testing all bone-plate constructs withstood 1,000,000 cycles. Four bone-plate constructs failure occurred before 1,000,000 cycles in cantilever bending fatigue testing. In conclusion, the locking T-plate tested has mechanical properties that offer greatest resistance to fracture under axial loading than bending forces.(AU)


O objetivo deste estudo foi desenvolver uma placa bloqueada em formato de T e avaliar as propriedades mecânicas em um modelo sintético. Uma placa-T em liga de titânio 2,7mm foi desenhada com uma haste contendo três orifícios para parafusos bloqueados e um orifício para realização de compressão dinâmica. 40 blocos de poliuretano em formato de T e 20 placas-T foram utilizados para os ensaios mecânicos. Seis montagens osso-placa foram testados até a falha, sendo três em força de compressão axial e três em flexão engastada. 14 montagens osso-placa foram testadas até a falha em fatiga, sendo 7 em força de compressão axial e 7 em flexão engastada. No teste estático, os valores mais altos foram observados em todas as variáveis no teste de compressão axial quando comparado à flexão engastada. Já nos testes de fadiga na força de compressão axial, todas as montagens osso-placa resistiram à 1000000 de ciclos. No teste de fadiga em flexão engastada, quatro montagens osso-placa falharam antes de alcançarem 1000000 de ciclos. Em conclusão, a placa-T estudada apresenta propriedades mecânicas que oferecem uma melhor resistência em estabilizar as fraturas na atuação das forças de compressão axial que nas forças de flexão.(AU)


Asunto(s)
Placas Óseas/tendencias , Fracturas Óseas/terapia , Fenómenos Mecánicos
18.
Br J Oral Maxillofac Surg ; 54(5): 573-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27068853

RESUMEN

We have evaluated the resistance to displacement of six stable methods of fixation of a sagittal split ramus osteotomy (SSRO) in the mandibular advancement with counterclockwise rotation. We tested 60 synthetic hemimandibles in six groups of 10 each: Group I - fixation with a straight four-hole 2.0mm miniplate; Group II - a straight six-hole 2.0mm miniplate; Group III - two straight 2.0mm four-hole miniplates; Group IV - an eight-hole 2.0mm (grid plate); Group V - a 2.0mm four-hole straight miniplate and 2.0×12mm bicortical screw; and Group VI - a straight four-hole 2.0mm locking miniplate. We applied a linear force in the region between the canine and the first premolar using a universal testing machine (EMIC- DL2000) with a loading cell of 10 KN. The loads at 1, 3, and 5mm displacement were recorded (N) and the data transmitted from the load cell to a computer. Results were analysed using analysis of variance (ANOVA) (p<0.001) and the Tukey post-test for comparison of the significance of the differences between the groups. For the three degrees of displacement, fixation with two straight 2.0mm plates and with the grid plate gave higher load values.


Asunto(s)
Placas Óseas , Avance Mandibular , Osteotomía Sagital de Rama Mandibular/métodos , Fenómenos Biomecánicos , Humanos , Mandíbula , Modelos Anatómicos
19.
Res. Biomed. Eng. (Online) ; 31(2): 169-175, Apr-Jun/2015. graf
Artículo en Inglés | LILACS | ID: biblio-829431

RESUMEN

Introduction Although there has been significant progress in the design of implants for osteosynthesis, the occurrence of failures in these medical devices are still frequent. These implants are prone to suffer from fretting corrosion due to micromotion that takes place between the screw heads and plate holes. Consequently, fretting corrosion has been the subject of research in order to understand its influence on the structural integrity of osteosynthesis implants. The aim of this paper is to correlate the surface finish characteristics of bone plate-screw systems with fretting corrosion. Methods The surface finish (machined and polished) of five specimens taken from three commercial dynamic compression plates (DCP) were evaluated. For testing, the specimens were fixed with bone screws, immersed in a solution of 0.90% NaCl and subjected to a rocking motion with an amplitude of 1.70 mm and frequency of 1.0 Hz for 1.0 × 106 cycles, according to the ASTM F897 standard. Both, plate and screws were manufactured in Brazil with ASTM F138 stainless steel. Results Flaws on the hole countersink area and on the screw thread of some specimens were identified stereoscopically. At the end of the test all the specimens showed evidence of fretting corrosion with an average metal loss of 4.80 mg/million cycles. Conclusion An inadequate surface finish in some areas of the plates and screws may have favored the incidence of damage to the passive film, accelerating the fretting corrosion at the interfaces between the plate hole countersink and the screw head. Keywords Osteosynthesis, DCP, Bone plate, Screw, Fretting corrosion, Stainless steel.

20.
Int J Oral Maxillofac Surg ; 44(3): 389-94, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25496850

RESUMEN

The aim of this study was to measure changes in buccal alveolar crestal bone levels after immediate placement and loading of dental implants with Morse taper prosthetic abutments after tooth extraction. This study followed the STROBE guidelines regarding prospective cohort studies. The sample comprised 12 patients with a mean age of 45 years, in whom a central or upper lateral incisor was indicated for extraction. Prior to extraction, computed tomography (CT) analysis was carried out to assess the presence of the buccal bone crest. CT scans were performed at 24 h and at 6 months after immediate implant placement and immediate loading. The distance from the most apical point of the implant platform to the buccal bone crest was assessed at the two time points. The buccal bone crest height was evaluated at three points in the mesio-distal direction: (1) the centre point of the alveolus, (2) 1mm mesial to the centre point, and (3) 1 mm distal to the centre point. The values obtained were subjected to statistical analysis, comparing the distances from the bone crest to the implant platform for the two time points. After 6 months there was a statistically significant, non-uniform reduction in height at the level of the crest of the buccal bone in the cervical direction. It is concluded that the buccal bone crest of the immediate implants that replaced the maxillary incisors underwent apical resorption when subjected to immediate loading.


Asunto(s)
Proceso Alveolar/patología , Proceso Alveolar/cirugía , Carga Inmediata del Implante Dental , Adulto , Anciano , Proceso Alveolar/diagnóstico por imagen , Pilares Dentales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteotomía , Estudios Prospectivos , Tomografía Computarizada por Rayos X , Extracción Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA