Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.125
Filtrar
1.
BMC Ophthalmol ; 24(1): 391, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227854

RESUMEN

BACKGROUND: Regional anaesthesia education, especially for ocular procedures, necessitates reliable surgical training models. While cadaveric models offer anatomical fidelity, conventional embalming methods may compromise tissue integrity. We aimed to assess the effectiveness of Thiel cadavers for training in sub-Tenon's blocks by evaluating ocular tissues and measuring insertion forces. METHODS: Experimental design, using twenty eyes from ten Thiel cadaver heads. These cadavers were specifically prepared to test the administration of sub-Tenon's blocks. The research was conducted in a controlled laboratory setting appropriate for handling cadaveric materials and conducting precise measurements. Each cadaver eye underwent an initial ultrasound examination, and its axial length was noted. An intravitreal injection of heptastarch solution followed, to re-establish the eye's sphericity. After this volume injection, the axial length and intraocular pressure were measured again. Mock sub-Tenon's blocks were administered in 2 separate quadrants of the eye, with insertion forces measured using a pressure gauge. These were compared to a data set of insertion forces measured in a series of isolated pig's eyes on which STBs had been performed. Main outcome measurements were macroscopic assessment of the ocular tissue layers and the insertion forces required for the sub-Tenon's blocks. In a second set of 10 Thiel cadaver heads, 5 ml of sodium chloride were injected as sub-Tenon's blocks and the emergence of a periocular "T-sign" ascertained and measured by ultrasound. RESULTS: Four of twenty eyes (20%) retained near-natural sphericity, with the remaining requiring volume injection to approximate physiological shape and pressure. The conjunctiva and Tenon's layer were intact, and correct cannula placement was achieved in all cases. In 16 of 20 eyes where T-signs could be measured, the median thickness of the T-sign amounted to 2.72 mm (range 1.34 mm-5.28 mm). The average maximum cannula insertion force was 2.92 Newtons. Insertion forces in intact Thiel cadaver heads were consistently higher than in isolated pig's eyes (3.6 N vs 2.0 N). CONCLUSION: These findings suggest that Thiel cadavers are a promising model for training in sub-Tenon'sblocks, despite the challenge of often desiccated and involuted eyes.


Asunto(s)
Cadáver , Estudios de Factibilidad , Humanos , Animales , Porcinos , Cápsula de Tenon , Bloqueo Nervioso/métodos , Oftalmología/educación , Presión Intraocular/fisiología
2.
J Gynecol Oncol ; 35(5): e112, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39251348

RESUMEN

OBJECTIVE: Complete resection is the curative treatment choice for recurrent gynecological malignancies. Laterally extended endopelvic resection (LEER) is an effective surgical salvage therapy for lateral recurrence. However, when a recurrent tumor occupies the ischial spine and sacrum, LEER is not indicated, and surgical salvage therapy is abandoned. Theoretically, complete resection of such a tumor is possible by additional pelvic bone resection along with the standard LEER. Nevertheless, owing to the anatomical complexities of the beyond-LEER procedure, 2 major issues should be solved: sciatic nerve injury and tumor disruption during pelvic bone amputation. To overcome these technical challenges, we applied a multidirectional beyond-LEER approach, a novel salvage surgical procedure, with an aim of demonstrating its technical feasibility. METHODS: We created a simulation model of a laterally recurrent tumor that occupied the right ischial spine and sacrum in a Thiel-embalmed cadaver. RESULTS: Multidirectional approaches, including laparoscopic, perineal, and dorsal phases, were safely applied. We laparoscopically marked the L4-L5-S1 complex and S2 nerve with different colored tapes, and by pulling them out into a dorsal surgical field, the sciatic nerve was safely preserved. The dissection lines of the multidirectional approaches were aligned using tapes as landmarks, and complete tumor clearance without tumor disruption was accomplished. By following the cadaveric training, the first laparoscopic-assisted beyond-LEER procedure was successfully performed in a patient with recurrent ovarian cancer. CONCLUSION: Using a Thiel-embalmed cadaver, we demonstrated the technical feasibility of a sciatic nerve-preserved beyond-LEER procedure, which was successfully performed in a patient with recurrent ovarian cancer.


Asunto(s)
Cadáver , Recurrencia Local de Neoplasia , Terapia Recuperativa , Nervio Ciático , Humanos , Femenino , Nervio Ciático/cirugía , Recurrencia Local de Neoplasia/cirugía , Terapia Recuperativa/métodos , Neoplasias de los Genitales Femeninos/cirugía , Laparoscopía/métodos , Laparoscopía/educación , Estudios de Factibilidad
3.
J Hand Microsurg ; 16(4): 100123, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39234365

RESUMEN

Introduction: The distal Posterior Interosseous Nerve (PIN) plays an important part in the sensory innervation of the wrist joint. Introduction of the arthroscopy portals during wrist arthroscopy might injure the PIN. The anatomic variation in the trajectory of the PIN and the proximity to the dorsal arthroscopy portals have not yet been fully explored. Materials and methods: Computer assisted surgical anatomy mapping (CASAM) is a technique to digitally compute and merge photographic images using anatomic landmarks and visualize variation in anatomy. A standard wrist arthroscopy procedure was carried out on eight cadaver forearms. CASAM was used to map the trajectory of the distal PIN and measure the distance to bony landmarks and the nearest wrist arthroscopy portals. Descriptive statistics were provided for anatomical measurements. Results: CASAM illustrated great variation in the PIN trajectories between the specimens. The mean distance from the PIN to Lister's tubercle was 9 â€‹mm (range 3-14, SD 3.9), the distance to the ulnar styloid was 27 â€‹mm (range 23-32, SD 3.3). None of the nerves showed signs of iatrogenic injury from placement of the arthroscopy portals. The 3-4 portal and the 6R portal were closest to the PIN with a respective mean distance of 9 â€‹mm (range 4-15, SD 3.8) and 19 â€‹mm (range 13-22, SD 3.2). Conclusion: CASAM demonstrated the importance of understanding nerve anatomy variations and offered insight into which arthroscopy portals are most likely to damage the distal PIN. However, we conclude that the overall risk of PIN injury from wrist arthroscopy is low due to the proximity to the portals.

4.
Cureus ; 16(8): e66508, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39246863

RESUMEN

The medial circumflex femoral artery contributes to the blood supply of the adductor muscles, hip joint, and femoral head. Its variations are common and important in the surgical field, as its damage can cause femoral head necrosis. Most commonly, the variations include different origin patterns from the femoral artery or its branches. Here we report a very rare variation of suprainguinal origin of the medial circumflex femoral artery from the external iliac artery in the common trunk with the inferior epigastric artery. Because of the rarity, such an arterial variation not commonly suspected during open or laparoscopic surgery may result in devastating consequences.

5.
BMC Med Educ ; 24(1): 974, 2024 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-39244572

RESUMEN

OBJECTIVES: This study aims to compare the efficacy of remote versus in-person training strategies to teach ultrasound guided knee arthrocentesis using formalin embalmed cadavers. METHODS: 30 first-year medical student participants were randomly assigned to remote or in-person training groups. Pre- and post- training surveys were used to evaluate participant's self-confidence in their ability to perform the procedure. Participants were asked to watch a 30-minute training video and then attend a skills training workshop. The workshops consisted of 20 min of hands-on instruction followed by a skills assessment. RESULTS: Following training, participant self-confidence increased significantly across all survey items in both groups (p = 0.0001). No significant changes in participant self-confidence were detected between the groups. Skills and knowledge-related metrics did not differ significantly between the groups with the exception of the "knowledge of instruments" variable. CONCLUSIONS: Our data suggests that remote ultrasound-guided procedure training, although logistically complex, is a viable alternative to traditional in-person learning techniques even for a notoriously hands on skill like ultrasound guided knee arthrocentesis. Novice first-year medical student operators in the remote-training group were able to significantly increase their confidence and demonstrate competency in a manner statistically indistinguishable from those trained in-person. These results support the pedagogical validity of using remote training to teach ultrasound guided procedures which could have implications in rural and global health initiatives where educational resources are more limited.


Asunto(s)
Artrocentesis , Cadáver , Competencia Clínica , Embalsamiento , Humanos , Artrocentesis/educación , Ultrasonografía Intervencional , Formaldehído , Articulación de la Rodilla/diagnóstico por imagen , Educación de Pregrado en Medicina/métodos , Educación a Distancia , Estudiantes de Medicina , Masculino , Femenino
6.
Brain Spine ; 4: 102906, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220412

RESUMEN

Introduction: Headholders or skull clamps serve as indispensable tools in neurosurgery, facilitating the precise positioning and stabilization of the head for surgery. The realm of neurosurgical training in cadaver labs presents a clear challenge due to the lack of suitable non-clinical headholders. Research question: We describe a 3D printed stainless-steel headholder for use in neurosurgical cadaver lab training. Material and methods: Computer-aided design software was used to design a headholder, utilizing a three-pin skull fixation. Through an iterative process involving a plastic 3D printed prototype, ultimately a robust model was manufactured using a 3D stainless-steel printer. Results: The headholder was fixed to a multi-angle adjustable vise, enabling optimal positioning to support simulation of neurosurgical approaches and dissection training by neurosurgical residents and staff in the cadaver lab. Discussion and conclusion: This custom-made headholder offers an effective solution for secure fixation of cadaver skulls during neurosurgical training, contributing to practicality and efficiency in cadaver dissection. Despite the lack of evidence-based guidelines for neurosurgical headholder use, this device provides a valuable tool for neurosurgical trainees to practice proper placement, understand associated complications, and improve their hands-on skills. The digitally available 3D model can be optimized, shared, and further improved by other neurosurgical units and trainees, fostering collaborative advancements in neurosurgical training.

7.
Surg Radiol Anat ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225862

RESUMEN

BACKGROUND: Surgical approaches to the cavernous sinus (CS) and middle cranial fossa (MCF) can be challenging, particularly for young neurosurgeons. The anteromedial (Mullan's) triangle is a triangle by the side of the CS and constitutes part of the floor of the MCF. The contents include the sphenoid sinus, superior ophthalmic vein, and sixth cranial nerve. The literature contains very little research that has precisely defined and measured the anteromedial triangle while considering anatomical variances minimally. METHODOLOGY: The present study was conducted on the skulls of 25 adult human cadavers which were dissected to expose the anteromedial (Mullan's) triangle on both sides. After precisely defining the triangle on each side, measurements of the three borders were taken, and using Heron's formula, the area of each triangle was calculated. RESULTS: On average, the length of the medial border was 12.5 (+ 3.1 mm); the length of the lateral border was 9.9 (+ 3.1 mm); the length of the base was 10.75 (+ 2.4 mm) and the area of the anteromedial triangle was 43.9 (+ 15.06 mm2). CONCLUSION: Precise anatomical knowledge of the Mullan's triangle enables the treatment of disorders in often deformed anatomy or difficult-to-access structures. That is the reason it is important to gain a thorough understanding of the surgical anatomy and to adopt a safe procedure.

8.
Int. j. morphol ; 42(4)ago. 2024.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1569260

RESUMEN

SUMMARY: The axillary artery is a continuation of the subclavian artery and transitions into the brachial artery. Variations in the axillary artery are not uncommon. During the upper-limb dissection of a 95-year-old Korean female cadaver, assorted anatomical variations of the axillary artery branches were identified. On the right side, no branches emerged from the first part of the axillary artery. The thoracoacromial artery (excluding the pectoral branch) and the common subscapular trunk arose from the second part, with the common subscapular trunk giving origins to the pectoral branch, lateral thoracic artery, and subscapular artery. The subscapular artery is divided into the thoracodorsal artery, circumflex scapular artery, and accessory posterior circumflex humeral artery. Additionally, the superior thoracic artery arose from the lateral thoracic artery. The third part of the axillary artery gave rise to the anterior and posterior circumflex humeral arteries, accessory acromial branch, and accessory thoracodorsal artery. On the left side, the thoracoacromial artery (excluding the pectoral branch) and the superior thoracic artery arose from the first part. The common subscapular trunk arose from the second part, which included the pectoral branch, lateral thoracic artery, and subscapular artery. The subscapular artery is divided into the thoracodorsal artery, circumflex scapular artery, accessory posterior circumflex humeral artery, and accessory lateral thoracic artery. The third part gave rise to the anterior and posterior circumflex humeral arteries and the accessory acromial branch. This study presents variations of the axillary artery, emphasizing their rarity, considering their embryologic basis, and highlighting their importance not only for educational purposes but also surgical and radiological applications.


La arteria axilar es una continuación de la arteria subclavia y luego esta continua como arteria braquial. Las variaciones en la arteria axilar no son infrecuentes. Durante la disección de los miembros superiores de un cadáver de una mujer coreana de 95 años, se identificaron diversas variaciones anatómicas de las ramas de la arteria axilar. En el lado derecho no se originaban ramas de la primera parte de la arteria axilar. La arteria toracoacromial (excluyendo la rama pectoral) y el tronco subescapular común surgieron de la segunda parte, y el tronco subescapular común dio origen a la rama pectoral, la arteria torácica lateral y la arteria subescapular. La arteria subescapular se dividía en arteria toracodorsal, arteria circunfleja escapular y arteria humeral circunfleja posterior accesoria. Además, la arteria torácica superior se originaba de la arteria torácica lateral. La tercera parte de la arteria axilar dio origen a las arterias circunflejas humerales anterior y posterior, la rama acromial accesoria y la arteria toracodorsal accesoria. En el lado izquierdo, de la primera parte surgían la arteria toracoacromial (excluyendo la rama pectoral) y la arteria torácica superior. De la segunda parte se originaba el tronco subescapular común, que incluía la rama pectoral, la arteria torácica lateral y la arteria subescapular. La arteria subescapular se dividía en arteria toracodorsal, arteria circunfleja escapular, arteria circunfleja humeral posterior accesoria y arteria torácica lateral accesoria. La tercera parte daba origen a las arterias circunflejas humerales anterior y posterior y a la rama acromial accesoria. Este estudio presenta variaciones de la arteria axilar, enfatizando su rareza, considerando su base embriológica y destacando su importancia no sólo para fines educativos sino también para aplicaciones quirúrgicas y radiológicas.

9.
Br J Anaesth ; 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39117476

RESUMEN

BACKGROUND: As few anaesthetists provide lumbar erector spinae block for disc surgery, there is a need to provide training to enable a randomised controlled trial investigating analgesia after painful spinal surgery (NIHR153170). The primary objective of the study was to develop and measure the construct validity of a checklist for assessment of skills in performing lumbar and thoracic erector spinae fascial plane injection using soft-embalmed Thiel cadavers. METHODS: Twenty-four UK consultant regional anaesthetists completed two iterations of a Delphi questionnaire. The final checklist consisted of 11 steps conducive to best practice. Thereafter, we validated the checklist by comparing the performance of 12 experts with 12 novices, each performing lumbar and thoracic erector spinae plane injections or fascia iliaca, serrato-pectoral (PEC II) and serratus injections, randomly allocated to the left and right sides of six soft-embalmed Thiel cadavers. Six expert, trained raters blinded to operator and site of block examined 120 videos each. RESULTS: The mean (95% confidence interval) internal consistency of the 11-item checklist for erector spinae plane injection was 0.72 (0.63-0.79) and interclass correlation was 0.88 (0.82-0.93). The checklist showed construct validity for lumbar and thoracic erector spinae injection, experts vs novices {median (interquartile range [range]) 8.0 (7.0-10.0 [1-11]) vs 7.0 (5.0-9.0 [4-11]), difference 1.5 (1.0-2.5), P<0.001}. Global rating scales showed construct validity for lumbar and thoracic erector spinae injection, 28.0 (24.0-31.0 [7-35]) vs 21.0 (17.0-24.0 [7-35]), difference 7.5 (6.0-8.5), P<0.001. The most difficult items to perform were identifying the needle tip before advancing and always visualising the needle tip. Instrument handling and flow of procedure were the areas of greatest difficulty on the global rating scale (GRS). Checklists and GRS scores correlated. There was homogeneity of regression slopes controlling for status, type of injection, and rater. Generalisability analysis showed a high reliability using the checklist and GRS for all fascial plane blocks (Rho [ρ2] 0.93-0.96: Phi [ϕ] 0.84-0.87). CONCLUSIONS: An 11-point checklist developed through a modified Delphi process to provide best practice guidance for fascial plane injection showed construct validity in performing lumbar and thoracic erector spinae fascial plane injection in soft-embalmed Thiel cadavers.

10.
Surg Endosc ; 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160305

RESUMEN

BACKGROUND: Nowadays, video-assisted thoracic surgery (VATS) lobectomy represents the treatment of choice for early-stage lung cancer. Over the years, different methods for VATS training have evolved. The aim of this study is to present an innovative beating-heart filled-vessel cadaveric model to simulate VATS lobectomies. METHODS: Via selective cannulation of the cadaver heart, the pulmonary vessels were filled with a gel to improve their haptic feedback. An endotracheal tube with a balloon on its tip then allowed movement of the heart chambers, transmitting a minimum of flow to the pulmonary vessels. A simulated OR was created, using all instrumentation normally available during surgery on living patients, with trainees constantly mentored by experienced surgeons. At the end of each simulation, the participants were asked 5 questions on a scale of 1 to 10 to evaluate the effectiveness of the training method ("1" being ineffective and "10" being highly effective). RESULTS: Eight models were set up, each with a median time of 108 min and a cost of €1500. Overall, 50 surgeons were involved, of which 39 (78%) were consultants and 11 (22%) were residents (PGY 3-5). The median scores for the 5 questions were 8.5 (Q1; IQR1-3 8-9), 8 (Q2; IQR1-3 7-9), 9 (Q3; IQR1-3 8-10), 9 (Q4; IQR1-3 8-10), and 9 (Q5; IQR1-3 8-10). Overall, the model was most appreciated by young trainees even though positive responses were also provided by senior surgeons. CONCLUSIONS: We introduce a new beating-heart filled-vessel cadaveric model to simulate VATS lobectomies. From this initial experience, the model is cost effective, smooth to develop, and realistic for VATS simulation.

11.
Strabismus ; : 1-4, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39155664

RESUMEN

Purpose: The anatomy of the extraocular rectus muscle insertions is clinically relevant in the field of ophthalmology. This descriptive cadaveric study determines the relative degree orientation of the superior, lateral, and inferior rectus muscles with respect to the medial rectus and investigates the distances between the rectus muscle insertions. Method: Thirty cadavers (50% female, mean age = 81.86 years, SD 12.16) were included for a total of 60 eyes. For each eye, a lateral canthotomy and cantholysis were performed followed by a peritomy. Muscle hooks were then used to access and isolate the rectus muscles. The degree orientation was determined by marking the muscle midpoints at insertion, using the center of the cornea as the vertex, and measuring the angle with the Angle Meter 360 application (© Alexey Kozlov) (Figure 1). The distances between rectus muscles were measured from the same muscle midpoints using calipers. Results: The degree orientations with respect to the medial rectus are displayed in Figure 2 and were as follows: superior rectus (mean = 93.14, SD = 3.04, min. 82.3, max. 100.3), lateral rectus (mean = 180.21, SD = 5.65, min. 170.5, max. 190.6), and inferior rectus (mean = 90.57, SD = 4.47, min. 84.0, max. 98.9). The distances (measured in mm) between rectus muscle midpoints at insertion included medial rectus to inferior rectus (mean = 13.64, SD = 0.54), inferior rectus to lateral rectus (mean = 13.79, SD = 0.75), lateral rectus to superior rectus (mean = 13.54, SD = 0.63), and superior rectus to medial rectus (mean = 13.83, SD = 0.75). The relative distances between the midpoints of the extraocular muscles observed in males versus females showed statistically significant differences in medial rectus to inferior rectus (13.8 vs. 13.5, p = .01), inferior rectus to lateral rectus (14.1 vs. 13.5, p = .03), and superior rectus to medial rectus (14.0 vs. 13.5, p = .04), respectively (Table 1). Conclusion: This is an important study of the extraocular muscle degree orientation performed with an innovative measuring approach. The degree orientation of the insertions relative to the medial rectus may have surgical application in the field of ophthalmology.

12.
Clin Anat ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39141520

RESUMEN

The sternoclavicular joint (SCJ) functions as the basal joint of the entire upper limb and must move in the proper pattern for normal scapular motion. Afferent sensations from joints, such as proprioception and pain sensation, are important for maintaining the proper motion and condition of joints. Detailed anatomical data are useful for discussing injuries or surgeries that impair the afferent nerve to the SCJ. Nerve branches to SCJs were examined on 12 sides, and the subclavian nerve was investigated on six sides to clarify whether it innervates this joint. On seven of the 12 sides, the SCJ was innervated by two nerves, (1) a branch from the medial supraclavicular nerve that ran medially along the clavicle and (2) a branch from the lateral pectoral nerve that innervated the clavicular head and upper part of the sternocostal head of the pectoralis major. This branch ran medially behind the clavicular head of the pectoralis major and reached the SCJ. In the remaining five sides, the SCJ was innervated solely by the branch from the medial supraclavicular nerve. Subclavian nerves ended within the subclavius muscle or periosteum of the clavicle and were separate from the SCJs. Our data on the route of nerve branches to the SCJ suggest that injury or surgery, such as clavicle fracture or resection of the clavicular head of the pectoralis major for myocutaneous flap transfer, can impair the SCJ's afferent nerve supply.

13.
J Clin Med ; 13(15)2024 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-39124677

RESUMEN

Background: Approximately 40% of chronic low back pain patients have a discogenic origin. In relation to intervertebral disc injuries, most of them are in the posterior and lateral zone of the disc, involving the anterior lumbar roots and the spinal cord. Objective: The objective was to analyze and describe the accuracy and safety of a new ultrasound-guided approach to target the posterolateral part of the intervertebral lumbar discs in cadaveric specimens. Methods: A cross-anatomical study on sixty cadaver intervertebral lumbar discs was performed. A needle was introduced in the posterolateral part of the discs using ultrasound guidance. A transducer was placed in the anterior abdomen to visualize the discs in cross-section as well. A dissection of the specimen was performed to visualize the final position of the needle tip and its distance from the main lumbar structures. The angulation, length, and distance of the needle from the vertebral spine, the relevant ultrasound anatomical references, and the accuracy of the procedure were evaluated. Results: The needle tip reached the posterolateral part of the discs in 93.3% of the attempts. The mean length of the needle inserted was 79 ± 15 mm, the angulation 129 ± 20.2°, the distance from the spinous process was 77 ± 19 mm, and the distance of the needle to the nerve roots was 2.0 ± 1.2 mm. No statistically significant differences between genders were found. Conclusions: An ultrasound-guided technique can be an accurate and safe technique to perform invasive procedures on the posterolateral part of the intervertebral lumbar discs.

14.
BMC Med Educ ; 24(1): 931, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-39192224

RESUMEN

BACKGROUND: Standard training for ultrasound-guided cyst needle aspiration is currently performed on live patients during residency. This practice presents risk of iatrogenic injury to patients and provides a high-stress learning environment for medical trainees. Simulation training using synthetic cysts in a formalin-embalmed cadaver model may allow for realistic, practical, and effective training free from patient risk. METHODS: Thirty first-year medical students viewed an orientation video, then attended a skills workshop to perform cyst needle aspiration in formalin-embalmed cadaver tissue under ultrasound guidance. Participants were randomly assigned to one of three ultrasound-trained instructor-types which included a medical student, clinical anatomist, or an ultrasound fellowship trained emergency medicine physician. After training, participants underwent a 5-min skills test to assess their ability to drain a synthetic cyst independently. Pre- and post-training self-confidence surveys were administered. RESULTS: Ultrasound images of synthetic cysts in formalin-embalmed tissue were clear and realistic in appearance, and sonographic needle visualization was excellent. Participants took an average of 161.5 s and 1.9 attempts to complete the procedure. Two of the 30 participants could not complete the procedure within the time limit. Participants' self-reported confidence with respect to all aspects of the procedure significantly increased post-training. Mean confidence scores rose from 1.2 (95% CI 0.96 to 1.39) to 4.4 (95% CI 4.09 to 4.53) (P < 0.0001) Procedure time, number of attempts, performance scores, and self-confidence outcomes were not significantly affected by instructor type. CONCLUSIONS: The use of synthetic cysts in formalin-embalmed cadaveric tissue is feasible, realistic, and efficacious for the teaching of ultrasound-guided needle aspiration to novice medical trainees. This simulation training method can be delivered effectively by multiple instructor types and may allow medical trainees to increase their tactical skill and self-confidence prior to performing ultrasound-guided cyst needle aspiration on live patients.


Asunto(s)
Cadáver , Competencia Clínica , Entrenamiento Simulado , Humanos , Formaldehído , Estudiantes de Medicina , Embalsamiento , Ultrasonografía Intervencional , Masculino , Educación de Pregrado en Medicina/métodos , Femenino
15.
J Funct Biomater ; 15(8)2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39194676

RESUMEN

(1) Background: OD burs are used in two different modes: (i) CW and (ii) CCW. The purpose of the study was to evaluate the ΔT during the preparation of implant osteotomies in a four-way interaction. (2) Methods: Three hundred and sixty osteotomies were prepared at 12 mm depth in human cadaver tibiae. The ΔT values were calculated similarly to the method used in two previous studies carried out by our group. Four different variables were evaluated for their effect on ΔT. (3) Results: A four-way interaction was observed in the CCW mode, allowing for 1000 RPM to have the least effect in both modes. However, in the CCW mode the use of 3.0 and 4.0 burs after 23 osteotomies showed a statistically significant increase in ΔT, and significant chatter, compared to the CW mode. In the CCW mode, the ΔT was increased significantly as the diameter of the burs increased in 800 and 1200 RPM. (4) Conclusions: The synergistic effect of drills' diameter, CCW mode, 800 and 1200 RPM, and bur usage (over 23 times) had a significant effect on ΔT, which exceeded 47 °C. One thousand (1000) RPM had the least effect in both modes. The 3.0 and 4.0 burs in the CCW mode drastically increased the temperature and produced significant chatter.

16.
Surg Radiol Anat ; 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39172258

RESUMEN

BACKGROUND: The xiphoid process (XP) in animals such as sheep and rats are well known to have cartilage called xiphoidal cartilage (XC). In humans, the cartilage in the xiphoid process is considered an anatomical variant and is not well understood. The aim of this study was to investigate the morphology of the XP. METHODS: A total of twenty embalmed European descendant cadaveric sterna (aged 52 to 98 years) were used. Transilluminated XPs and midsagittal sections of XPs were used to examine the bone and cartilage. Subsequently, a sagittally-sectioned XP was harvested for histology and stained with Masson's trichrome. The results of the transillumination and histological examinations were compared qualitatively. RESULTS: The dark area visible in transilluminated XPs was consistent with the bony part in the midsagittal XP sections, which contained bone marrow; the bright area was consistent with the cartilage part in the midsagittal XP sections. This was all demonstrated histologically. Most of the XPs (85%) had some portion of cartilage. The XP was classified into four types based on its proportions of bone and cartilage: Type I, no ossification (< 1/3 ossification) 45%; Type II, minor ossification (1/3 - 1/2 ossification) 20%; Type III, major ossification (1/2-2/3 ossification) 20%; Type IV, complete ossification (> 2/3 ossification) 15%. Most of the XPs (85%) had bone and cartilage, which could have been overlooked in studies using skeletons or CT. CONCLUSION: Previous studies probably underestimated or overestimated the size of the XP. The XC needs to be considered as normal anatomy.

17.
Ann Anat ; 257: 152327, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39216673

RESUMEN

BACKGROUND: The teaching of anatomy from early days of medical education relied on the use of cadaver; hence, the present study assessed the support for whole-body donation among academic staff. METHODS: This is a cross-sectional study conducted from January to March 2024 in Southwestern Ugandan medical educational schools among 160 academic staff. Ethical approval was obtained and structured questionnaires were distributed to study participants in the selected Medical Educational Schools. RESULTS: Among the 160 sampled academic staff, only 16 % and 18 % supported the donation of their whole-body and the bodies of their relatives/friends for anatomical education respectively. The reason put forward for respondents support for whole-body donation were contribution to medical science (88.5 %) and learnt from someone's body (53.8 %). The fear of misuse of their body (42.5 %), cultural (53.7 %) and religious (44.8 %) belief were the reasons for non-support for whole-body donation among the study participants. CONCLUSION: This study concluded that support for whole-body donation among academic staff was low; reasons for non-support were fear of misuse of body, religious and cultural beliefs; hence, we recommend the need for massive desensitization of the public aimed at building confidence on whole-body donation in the community.

18.
Ann Anat ; 256: 152324, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39186961

RESUMEN

BACKGROUND: The present study aims to investigate the feasibility of labeling ligaments using ultrasound-guided injections. On formalin-fixed cadavers, the anterolateral ligament was selected and targeted for demonstration. The development of portable ultrasound machines and the ability to connect them to tablets via Bluetooth or WLAN makes it an accessible tool to implement into the anatomical dissection courses in order to associate medical imaging (MRI and ultrasound), anatomical structures and their subsequent dissection. METHODS: 8 formalin fixed human cadavers were used for the ultrasound-guided injections of 1 mL of blue latex into the anterolateral ligament. 8 cadavers were not injected with latex for comparative purposes. The injections were performed by an experienced ultra-sonographer. After approximately 10 months, five dissections were carried out by students during the dissection course and three specimens were dissected by anatomists. RESULTS: The anterolateral ligament was successfully marked and demonstrated in 7 out of 8 cases. In 4 out of 5 cases, the dissection was primarily conducted by students, while in 3 out of 3 cases, it was performed by anatomists. The accuracy was 80 % and 100 %, respectively. CONCLUSION: The present study demonstrated that labeling obscure ligaments, such as the anterolateral ligament, using ultrasound guidance is feasible on formalin-fixed cadavers. It also showed that students can successfully perform the dissections as the structure is highlighted and that the time between injection and dissection (approximately 10 months) has little impact on the outcome. The use of ultrasound in dissection courses should be further encouraged.


Asunto(s)
Cadáver , Disección , Estudios de Factibilidad , Látex , Humanos , Ligamentos/anatomía & histología , Ligamentos/diagnóstico por imagen , Masculino , Femenino , Ultrasonografía/métodos , Ultrasonografía Intervencional/métodos , Anciano , Coloración y Etiquetado/métodos
19.
SAGE Open Nurs ; 10: 23779608241274543, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39169993

RESUMEN

Introduction: Cadaver dissection in anatomy, a cornerstone of medical school education, has been replaced by digital technologies. This study aimed to determine the learning outcomes nursing students could achieve through cadaveric dissection practice (CDP). Methods: This scoping review was carried out using the checklist outlined in the Reporting Items for Systematic Reviews and Meta-Analysis Extension for Scoping Reviews through August 2023. Articles from PubMed, ERIC, and CINAL were included. This scoping review included studies that focused on the learning effects of nursing students' experiences with cadaver dissection, written in English, and covered all study types. Results: The cadaveric dissection exercise resulted in a strong interest in the human body and a thorough understanding of anatomy and physiology. It also allows for creating an image of care for the patient before death, the meaning of existence after death, acceptance that death is not frightening, and an understanding of the afterlife. Furthermore, the cadaveric dissection exercise has been reported to improve confidence in patient care, lead to a better understanding of what other professions practice, and involve the development of professional identity. Conclusions: Studies on the learning effects of CDP have differed in subject matter and educational methodologies. In the future, while determining how the experience of CDP is related to nursing practice of nursing students and graduates, we must explore effective CDP and develop educational methodologies that can achieve similar learning effects.

20.
Indian J Crit Care Med ; 28(6): 614-616, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39130383

RESUMEN

During the onset of the pandemic, a common research question was asked by the hospital staff, and family members who were handling COVID-19-infected cadavers, "does COVID-19-positive dead body harbor SARS-CoV-2 viral RNA?" Several research findings were reported but due to the lack of proper research findings, the question remained unanswered. The present study was planned to observe the virus transmission risk from cadavers to the handlers. A pilot study was conducted on 54 cadavers who died in COVID-ICU (SARS-CoV-2-positive diagnosed by RT-PCR) during 2021-2022. Skin swab sample from 54 dead bodies and 54 glove samples of handlers were taken within 1 hour of death for the RT-PCR test. Viability results from RT-PCR show that the infection risk was 50% in cadavers, whereas the transmission risk to handlers while handling was 7%, which is minimal. The SARS-CoV-2 viability was high in cases of those died after a long time of infection. Based on the RT-PCR result and data analysis the interpretation of the study was that the SARS-CoV-2 transmission risk from dead bodies to the handlers is minimal but the SARS-CoV-2 viability persists in the cadavers. This fact is helpful for the people who will conduct funeral activities, autopsy staff, and hospital staff handling dead bodies. How to cite this article: Panda B, Singh N, Singh G, Patro ARK, Mohanty AP, Patnaik PK, et al. RT-PCR Result of SARS-CoV-2 Viral RNA in Cadavers and Viral Transmission Risk to Handlers. Indian J Crit Care Med 2024;28(6):614-616.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA