Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cardiothorac Surg ; 19(1): 143, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38504317

RESUMEN

BACKGROUND: Coronary artery obstruction after percutaneous aortic replacement is a complication with high short-term mortality secondary to the lack of timely treatment. There are various predictors of coronary obstruction prior to valve placement such as the distance from the ostia, the degree of calcification, the distance from the sinuses; In such a situation some measures must be taken to prevent and treat coronary obstruction. CASE PRESENTATION: An 84-year-old male, with severe aortic stenosis and high surgical risk, who was treated with TAVR. However, during the deployment of the valve he presented hemodynamic instability secondary to LMCA obstruction. The intravascular image showed obstruction of the ostium secondary to the displacement of calcium that he was successfully treated with a chimney stent technique. CONCLUSIONS: The high degree of calcification and the left ostium near the annulus are conditions for obstruction of the ostium at the time of valve release; In this context, provisional stenting prior to TAVR in patients at high risk of obstruction should be considered as a safe prevention strategy to achieve the success of the procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Oclusión Coronaria , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Vasos Coronarios/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Oclusión Coronaria/etiología , Calcinosis/complicaciones , Calcinosis/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Diseño de Prótesis
2.
J Vasc Surg ; 76(2): 311-317, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35276255

RESUMEN

OBJECTIVE: Chimneys and periscopes are often used to treat pararenal or thoracoabdominal aneurysms de novo or after failed open or endovascular repair. We sought to describe our institutional experience, given their limited success and questionable long-term outcomes. METHODS: We retrospectively reviewed the electronic records for patients treated with chimneys/periscopes from 1997 through 2020. Baseline characteristics, procedural details, periprocedural complications, reinterventions, and midterm outcomes were collected. RESULTS: Fifty-eight patients (86 vessels) were treated; the median follow-up was 32 months (range, 0.03-104 months). There were 36% (n = 21) juxta-renal, 2% (n = 1) para-visceral, and 21% (n = 12) thoracoabdominal aneurysms, and 41% (n = 24) had pararenal failure of prior endovascular aneurysm repair (n = 17) or open repair (n = 7). Stent configuration for the majority of the 86 vessels (n = 80; 93%) treated were chimney configuration (n = 6 periscopes; 7%). The most common stent graft utilized was Viabahn, and 8.1% (n = 7) were reinforced with a bare metal stent. Although the majority of the cases were elective, 36.2% (n = 21) of the cases were urgent/emergent. At the conclusion of the initial procedure, 16 of 58 patients had an endoleak (gutter, 50% [8/16]; type Ia, 25% [4/16]; and type II, 25% [4/16]). On follow-up, 14 of 58 patients developed one or more endoleaks, with the most common endoleaks being a gutter endoleak (35% [7/20]). Other endoleaks observed included 30% (6/20) type III, 15% (3/20) type Ia, 15% (3/20) type Ib, and 5% (1/20) type II. Eleven of 58 patients underwent interventions for one or more endoleak (gutter, 33% [5/15]; type Ib, 20% [3/15]; type II, 7% [1/15]; and type III, 40% [6/15]). Twelve of 58 patients returned to the operating room for one or more procedures during the index hospitalization (five laparotomies, three dialysis access, three acute limb ischemia, and four chimney/periscope interventions). Ten of 58 patients underwent angioplasty/stenting for chimney/periscope compression or occlusion during the follow-up period. Survival was 61.3% at 1 year by Kaplan-Meier analysis (75% for elective, 37% for urgent/emergent) (aneurysm-related death, 22%). Cox hazard modeling showed that aneurysm diameter (hazard ratio, 1.03; 95% confidence interval, 1.004-1.05; P = .02) and urgent/emergent interventions (hazard ratio, 3.6; 95% confidence interval, 1.33-9.74; P = .01) were predictors of mortality. CONCLUSIONS: Endovascular repair of aortic aneurysms with chimneys/periscopes is associated with poor outcomes, including limited technical success and aneurysm exclusion, as well as high morbidity and mortality, with a high rate of reinterventions both in the immediate postoperative period and on follow-up. They should be used only when other surgical or endovascular options are not possible.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Prótesis Vascular/efectos adversos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/terapia , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-33105825

RESUMEN

Household air pollution (HAP) due to solid fuel use during pregnancy is associated with adverse birth outcomes. The real-life effectiveness of clean cooking interventions has been disappointing overall yet variable, but the sociodemographic determinants are not well described. We measured personal 24-h PM2.5 (particulate matter <2.5 µm in aerodynamic diameter) thrice in pregnant women (n = 218) gravimetrically with Teflon filter, impactor, and personal pump setups. To estimate the effectiveness of owning chimney and liquefied petroleum gas (LPG) stoves (i.e., proportion of PM2.5 exposure that would be prevented) and to predict subject-specific typical exposures, we used linear mixed-effects models with log (PM2.5) as dependent variable and random intercept for subject. Median (IQR) personal PM2.5 in µg/m3 was 148 (90-249) for open fire, 78 (51-125) for chimney stove, and 55 (34-79) for LPG stoves. Adjusted effectiveness of LPG stoves was greater in women with ≥6 years of education (49% (95% CI: 34, 60)) versus <6 years (26% (95% CI: 5, 42)). In contrast, chimney stove adjusted effectiveness was greater in women with <6 years of education (50% (95% CI: 38, 60)), rural residence (46% (95% CI: 34, 55)) and lowest SES (socio-economic status) quartile (59% (95% CI: 45, 70)) than ≥6 years education (16% (95% CI: 22, 43)), urban (23% (95% CI: -164, 42)) and highest SES quartile (-44% (95% CI: -183, 27)), respectively. A minority of LPG stove owners (12%) and no chimney owner had typical exposure below World Health Organization Air Quality guidelines (35 µg/m3). Although having a cleaner stove alone typically does not lower exposure enough to protect health, understanding sociodemographic determinants of effectiveness may lead to better targeting, implementation, and adoption of interventions.


Asunto(s)
Contaminación del Aire Interior , Contaminación del Aire , Culinaria , Exposición a Riesgos Ambientales , Contaminación del Aire/prevención & control , Contaminación del Aire Interior/prevención & control , Biomasa , Culinaria/instrumentación , Exposición a Riesgos Ambientales/prevención & control , Femenino , Guatemala , Humanos , Material Particulado/análisis , Material Particulado/toxicidad , Embarazo
4.
Sci Total Environ ; 468-469: 12-8, 2014 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-24012891

RESUMEN

Radon levels in two old mines in San Luis, Argentina, were measured and analyzed, with the aim to assess the potential use of this radioactive noble gas as a tracer of geological processes in underground environments. La Carolina gold mine and Los Cóndores tungsten mine are today used as tourism mines. CR-39 nuclear track detectors were used for this purpose. Measurements were performed during both winter and summer seasons. The findings show that in these environments, significant radon concentrations are subject to large seasonal fluctuations, due to the strong dependence on natural ventilation with the outside temperature variations. For both mines, higher concentration values of (222)Rn were observed in summer than in winter; with an extreme ratio of 2.5 times between summer and winter seasons for Los Cóndores mine. The pattern of radon transport inside La Carolina mine revealed, contrary to what was believed, that this mine behaves as a system with two entrances located at different levels. However, this feature can only be observed in the winter season, when there is a marked difference between the inside and outside temperatures of the mine. In the case of Los Cóndores mine, the radon concentration pattern distribution is principally established by air current due to chimney-effect in summer and winter seasons. In both cases, the analyses of radon pattern distribution appear as a good method to trace air currents, and then localize unknown ducts, fissures or secondary tunnels in subterranean environments.


Asunto(s)
Monitoreo del Ambiente/métodos , Minería , Trazadores Radiactivos , Radón/análisis , Movimientos del Aire , Argentina , Polietilenglicoles , Estaciones del Año , Temperatura
5.
Indoor Air ; 23(4): 342-52, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23311877

RESUMEN

Nearly half of the world's population depends on biomass fuels to meet domestic energy needs, producing high levels of pollutants responsible for substantial morbidity and mortality. We compare carbon monoxide (CO) and particulate matter (PM2.5) exposures and kitchen concentrations in households with study-promoted intervention (OPTIMA-improved stoves and control stoves) in San Marcos Province, Cajamarca Region, Peru. We determined 48-h indoor air concentration levels of CO and PM2.5 in 93 kitchen environments and personal exposure, after OPTIMA-improved stoves had been installed for an average of 7 months. PM2.5 and CO measurements did not differ significantly between OPTIMA-improved stoves and control stoves. Although not statistically significant, a post hoc stratification of OPTIMA-improved stoves by level of performance revealed mean PM2.5 and CO levels of fully functional OPTIMA-improved stoves were 28% lower (n = 20, PM2.5, 136 µg/m(3) 95% CI 54-217) and 45% lower (n = 25, CO, 3.2 ppm, 95% CI 1.5-4.9) in the kitchen environment compared with the control stoves (n = 34, PM2.5, 189 µg/m(3), 95% CI 116-261; n = 44, CO, 5.8 ppm, 95% CI 3.3-8.2). Likewise, although not statistically significant, personal exposures for OPTIMA-improved stoves were 43% and 17% lower for PM2.5 (n = 23) and CO (n = 25), respectively. Stove maintenance and functionality level are factors worthy of consideration for future evaluations of stove interventions.


Asunto(s)
Contaminación del Aire Interior/prevención & control , Culinaria/instrumentación , Calefacción/instrumentación , Humo/análisis , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/estadística & datos numéricos , Exposición a Riesgos Ambientales , Eucalyptus , Femenino , Humanos , Perú , Población Rural , Madera
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA