Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 645
Filtrar
1.
J Prosthodont ; 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734933

RESUMEN

PURPOSE: To evaluate the effect of different printing orientations and post-polymerization time with thermal cycling on the translucency of 3D-printed denture base resins. METHODS: Heat-polymerized (HP) acrylic resin specimens were fabricated and 3D-printed denture base materials (NextDent, ASIGA, FormLabs) were printed with different printing orientations (0, 45, 90 degrees) and subjected to different post-polymerization times (15-, 30-, 60-, and 90-min). All specimens were polished and immersed in distilled water for 1 day at 37°C. CIEDE2000 was used to measure the translucency parameters (TP00) before and after thermal cycling (5000 cycles) recording the color parameters (L*, a*, b*) against a black and white background using a spectrophotometer. k-factors ANOVA followed by post hoc Tukey's test (α = .05) was performed for statistical analysis. RESULTS: The k-factors ANOVA test showed a significant effect of resin material, post-polymerization time, and printing orientation on translucency (p < 0.001). In comparison to HP, all 3D-printed resins showed lower translucency with all post-polymerization times and printing orientation (p < 0.001) except FormLabs resin (p > 0.05). For all 3D-printed resins, the translucency increased, with increasing the post-polymerization time (p < 0.001) and 60- and 90-min showed the highest translucency. For printing orientation, 90 and 45 degrees significantly showed high translucency in comparison to 0 degrees (p < 0.001). FormLabs showed significantly higher translucency when compared with NextDent and ASIGA per respective printing orientation and post-polymerization time. The translucency significantly decreased after thermal cycling for all tested resins (p < 0.001). CONCLUSION: The findings of this study demonstrated that the translucency of 3D-printed resins is influenced by the printing orientation, post-polymerization time, and resin type. As a result, choosing a resin type, and printing orientation, with a longer post-polymerization time should be considered since it may improve the esthetic appearance of the 3D-printed resins.

2.
Comput Biol Med ; 175: 108550, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701590

RESUMEN

BACKGROUND AND OBJECTIVE: Complete denture is a common restorative treatment in dental patients and the design of the core components (major connector and retentive mesh) of complete denture metal base (CDMB) is the basis of successful restoration. However, the automated design process of CDMB has become a challenging task primarily due to the complexity of manual interaction, low personalization, and low design accuracy. METHODS: To solve the existing problems, we develop a computer-aided Segmentation Network-driven CDMB design framework, called CDMB-SegNet, to automatically generate personalized digital design boundaries for complete dentures of edentulous patients. Specifically, CDMB-SegNet consists of a novel upright-orientation adjustment module (UO-AM), a dental feature-driven segmentation network, and a specific boundary-optimization design module (BO-DM). UO-AM automatically identifies key points for locating spatial attitude of the three-dimensional dental model with arbitrary posture, while BO-DM can result in smoother and more personalized designs for complete denture. In addition, to achieve efficient and accurate feature extraction and segmentation of 3D edentulous models with irregular gingival tissues, the light-weight backbone network is also incorporated into CDMB-SegNet. RESULTS: Experimental results on a large clinical dataset showed that CDMB-SegNet can achieve superior performance over the state-of-the-art methods. Quantitative evaluation (major connector/retentive mesh) showed improved Accuracy (98.54 ± 0.58 %/97.73 ± 0.92 %) and IoU (87.42 ± 5.48 %/70.42 ± 7.95 %), and reduced Maximum Symmetric Surface Distance (4.54 ± 2.06 mm/4.62 ± 1.68 mm), Average Symmetric Surface Distance (1.45 ± 0.63mm/1.28 ± 0.54 mm), Roughness Rate (6.17 ± 1.40 %/6.80 ± 1.23 %) and Vertices Number (23.22 ± 1.85/43.15 ± 2.72). Moreover, CDMB-SegNet shortened the overall design time to around 4 min, which is one tenth of the comparison methods. CONCLUSIONS: CDMB-SegNet is the first intelligent neural network for automatic CDMB design driven by oral big data and dental features. The designed CDMB is able to couple with patient's personalized dental anatomical morphology, providing higher clinical applicability compared with the state-of-the-art methods.


Asunto(s)
Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Redes Neurales de la Computación , Diseño Asistido por Computadora
3.
Cureus ; 16(4): e58564, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38770459

RESUMEN

Xerostomia, commonly known as dry mouth, presents a significant challenge for individuals wearing complete dentures, affecting their oral health and quality of life. This review explores the relationship between saliva and complete dentures, highlighting the varied management strategies for xerostomia. Saliva plays a critical role in denture retention, lubrication, and oral environment buffering. Complete denture wearers often experience reduced salivary flow, aggravating symptoms of xerostomia. Various management approaches are discussed, including general measures such as hydration and salivary stimulation techniques which aim to boost saliva production naturally. The use of salivary substitutes provides artificial lubrication and moisture to alleviate dry mouth discomfort. Oral lubricating devices, such as sprays, gels, and lozenges, offer relief by mimicking saliva's lubricating properties, thereby improving denture stability and comfort. This review addresses the etiology of xerostomia in complete denture wearers and explores preventive measures to reduce its impact. A comprehensive approach has been discussed for the management of xerostomia which will help to improve the oral health and well-being of complete denture wearers experiencing dry mouth.

4.
Int J Prosthodont ; 0(0): 1-20, 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758587

RESUMEN

PURPOSE: To determine whether digital training improves conceptual skills acquisition for custom tray fabrication and tooth arrangement in the preclinical curriculum for complete denture fabrication. MATERIALS AND METHODS: A crossover design study compared third-year student grades after conventional (manual) and digital training. Half the students were trained with conventional techniques prior to digital, while the other half were trained with digital techniques prior to conventional. The first part of the study (DP1) focused on custom tray fabrication and involved 154 students. The second part (DP2) focused on tooth arrangement with 204 students. The effect of preliminary digital training on conceptual skills was assessed by comparing the results of the students using a Student's t-test. Results were also analyzed by ranking on the students' Perceptual Ability Test (PAT) score. Finally, students' satisfaction with the training was investigated. RESULTS: Students who completed the initial digital session achieved better custom tray fabrication and tooth arrangement in the subsequent manual sessions. For manual laboratory work, the most dexterous students (PAT1 group) demonstrated the best performance. However, PAT2 students had the best performance during the digital sessions during DP1, and PAT1 and PAT2 students had the best performance during the digital sessions during DP2. Additionally, 40% of DP1 and 12% of DP2 students expressed satisfaction with digital sessions. CONCLUSION: With complementary manual and digital teaching, digital tools may be useful for enhanced student learning. Digital training has contributed to improve results in manual sessions but did not affect student satisfaction and remained a limited tool to detect learning difficulties.

5.
Clin Oral Investig ; 28(6): 320, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750145

RESUMEN

OBJECTIVES: The purpose of this scoping review was to identify different methods employed for recording the maxillomandibular relationship (MMR) for computer-aided designed and manufactured (CAD-CAM) complete dentures (CDs). MATERIALS AND METHODS: This scoping review followed the PRISMA-ScR guidelines and was developed according to Arksey and O'Malley and The Joanna Briggs Institute protocol. The methods were registered on the Open Science Framework (< osf.io/rf4xm> ). The focus question was: "What are the different techniques for recording the maxillomandibular relationship in the digital workflow used in CECDs?" Two investigators searched 3 online databases [MEDLINE (PubMed), Scopus, and Science Direct] independently. The inclusion criteria were clinical studies and reviews that assessed techniques for recording MMR using digital workflow for manufacturing of CECDs. A descriptive analysis was performed considering the study design, manufacturing system, clinical steps, and tools for the determination of MMR, and the difficulty level of procedures. RESULTS: 4779 articles were identified in the electronic search and 10 studies were included for data analysis. The review identified 4 commercially available CAD-CAM denture systems and 3 innovative methods suitable for abbreviating the number of appointments (2 to 4 visits). The trial denture is inherent to the procedure for the Baltic System and 3 innovative techniques. Three techniques (2 innovative and WholeYouNexteeth) demonstrated lower difficulty levels for performing the clinical procedures, regardless of the professional skills. CONCLUSIONS: The commercially available and innovative techniques for the recording of MMR may provide predictability of the treatment. The techniques are effective, however, rely on the learning curve and the patient's clinical condition. CLINICAL RELEVANCE: Recording of the maxillomandibular relationship is paramount for the manufacturing and functionality of complete dentures. Clinicians should be aware of the different tools and techniques described for registering the jaw relationship.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Dentadura , Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Registro de la Relación Maxilomandibular/métodos
6.
J Oral Biol Craniofac Res ; 14(3): 284-289, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38577263

RESUMEN

Aim: To identify the optimal number and position of implants to reduce stress concentration on the implant, denture, and attachment system for sustaining an overdenture prosthesis. Materials and methods: By incorporating one to eight indigenous implants with bar-type attachments, eight 3D finite element models of mandibular overdentures were created. All models received a 200 N vertical load, and the biomechanical characteristics of peri-implant bone were assessed. Result: The study observed that with a vertical load of 200 N, the maximum equivalent stress around peri-implant tissue in all models was within the physiological tolerance threshold of bone. The von Mises stress values ranged from 116.18 MPa to 536.7 MPa. Conclusion: The three-implant-supported overdenture model revealed superior peri-implant stress, stability, cost-effectiveness, and hygiene maintenance outcomes. Placing a third implant in the mid-symphysis region may offer a practical solution to reduce rotations in two-implant-supported overdentures.

7.
Gerodontology ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563231

RESUMEN

OBJECTIVE: To evaluate the touch perception threshold of the alveolar mucosa and quality of life of edentulous patients before (T0) and 30 days after (T1) the insertion of new complete dentures. BACKGROUND: Touch perception is important so that edentulous patients can detect the position of complete dentures in their mouth. MATERIALS AND METHODS: This study included 32 complete denture wearers with good oral and systemic health and no temporomandibular disorders for at least 5 years. At each time point (T0 and T1), two tests were performed (touch perception threshold and quality-of-life scale). The touch perception threshold (Von Frey or Semmes-Weinstein test) was assessed using nylon monofilaments on the regions of the alveolar mucosa of the maxilla and mandible. The Oral Health Impact Profile for edentulous individuals (OHIP-EDENT) was administered to evaluate oral health-related quality of life. RESULTS: In the maxilla and mandible, the touch perception thresholds for all regions of the alveolar mucosa were significantly lower at T1 than at T0. The OHIP-EDENT mean scores showed that the overall quality of life was significantly better at T1 (3.6) than at T0 (4.7), and a significant improvement in quality of life was observed in all domains of the OHIP-EDENT at T1. For touch perception threshold, effect sizes ranged from 0.4 to 0.8; and for quality of life, effect sizes ranged from 0.4 to 1.0. CONCLUSIONS: New complete dentures reduced the touch perception threshold of the alveolar mucosa of both edentulous arches and improved individuals' quality of life.

8.
Gerodontology ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563273

RESUMEN

OBJECTIVES: To compare the impact of three complete denture palatal rugae designs on participants' satisfaction and oral-health-related quality of life. BACKGROUND: Complete dentures palatal rugea are usually polished to a smooth finish, which can affect the patient's adaptation. Roughening or keeping an opening in the rugae area to replicate the natural sensation of the palatal rugae has been suggested but lacks clinical evidence. METHODS: This randomised crossover trial included participants with complete dentures randomly allocated to six sequences. Each sequence alternated between polished, roughened, and open rugae designs. Participants evaluated general and domain-specific satisfaction (eating, taste, speaking, phonetics, and ease of cleaning) on a 100-mm visual analogue scale. They also completed the Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT) and indicated their preferred design at the end. Repeated-measure ANOVA compared satisfaction, and one-way ANOVA with Tukey's test compared OHIP-EDENT scores. RESULTS: Forty-two participants were randomised. Seven dropped out. General satisfaction ratings were comparable for the polished (Mean = 80.2, SD = 19.7) and roughened designs (Mean = 79.5, SD = 20.2). However, the open design had a significantly lower satisfaction rating (Mean = 41.1, SD = 32.2). OHIP-EDENT scores for the open design (Mean = 44.9, SD = 17.5) were significantly worse than those for the polished (Mean = 36.1, SD = 12.7) and roughened designs (Mean = 36.2, SD = 13.3). Two-thirds of the participants chose the polished design. One-third chose the roughened design; of those, 83% were first-time denture wearers. CONCLUSIONS: Complete dentures with polished and roughened rugae designs were perceived similarly. Both designs could be recommended based on the patient's preference. However, the open design should be avoided due to negative perception.

9.
J Dent ; 145: 104993, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38657724

RESUMEN

OBJECTIVES: This study aimed to compare the physical and mechanical properties of four denture base materials: Polyan IC (PA), milled polymethylmethacrylate (PMMA), three-dimensional (3D)-printed resin (3DP), and SR Ivocap (SR). METHODS: Ninety-six samples were prepared and divided into four groups as follows. Group A consisted of 3DP (Asiga DentaBASE, Asiga) fabricated using a manufacturer-recommended 3D printer (Asiga Pro 4k, Asiga). Group B comprised milled PMMA (MP) (Ivotion Base, Ivoclar Vivadent). Group C included PA (BredentSenden), meanwhile, group D involved SR (Ivoclar VivadentSchaan). Cuboid samples (65 mm x 10 mm x 2.5 mm) were used for biaxial flexure strength testing in a universal testing machine (UTM). Cylindrical samples of 20 mm x 40 mm were used for compressive strength testing in a UTM. Additionally, cuboid samples (65 mm x 10 mm x 2.5 mm) were used for Vickers surface hardness testing in a microhardness tester. disk samples (10 mm x 2.5 mm) were employed for color stability testing both in a coffee solution and Coca-Cola, using a digital spectrophotometer. Statistical analyses were performed using one-way analysis of variance and Tukey's post hoc analysis (α=0.05). RESULTS: MP demonstrated superior compressive strength (p = 0.002) and color stability compared to that exhibited by 3DP (p < 0.001) while displaying similar flexure strength (p = 0.336) and hardness (p = 0.708). MP and PA displayed similar compressive strength (p = 0.081), flexure strength (p = 0.159), and color stability in coke (p = 0.071). However, MP had reduced hardness (p < 0.001) and color stability in coffee (p < 0.001). Moreover, MP demonstrated a higher compressive strength (p < 0.001) than that displayed by SR. However, the flexure strength, hardness, and color stability were similar (p > 0.05). Furthermore, 3DP exhibited comparable compressive strength (p = 0.334) to that of PA but demonstrated significantly lower flexure strength (p = 0.005), hardness (p < 0.001), and color stability (p < 0.001) compared to PA. In comparison to SR, PA had a higher compressive strength (p < 0.001), hardness (p = 0.001), and color stability in coffee (p < 0.001), although they demonstrated similar (p > 0.05) flexure strength and color stability in coke. CONCLUSIONS: The MP and PA demonstrated superior compressive strength than that exhibited by the other materials tested. The tested materials had similar flexure strengths, except for PA which demonstrated superiority over the 3DP. Among all tested materials, PA exhibited the highest hardness, while the 3DP was the least color-stable. CLINICAL SIGNIFICANCE: Considering the mechanical properties and color stability, Polyan and milled polymethylmethacrylate are preferred for complete denture fabrication. However, the limited repairability and complex handling of Polyan should be considered.


Asunto(s)
Color , Materiales Dentales , Bases para Dentadura , Dureza , Ensayo de Materiales , Polimetil Metacrilato , Propiedades de Superficie , Polimetil Metacrilato/química , Materiales Dentales/química , Fuerza Compresiva , Resinas Acrílicas/química , Impresión Tridimensional , Humanos , Estrés Mecánico , Análisis del Estrés Dental , Resistencia Flexional
10.
Bioengineering (Basel) ; 11(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38671758

RESUMEN

The purposes of this study are to establish and validate a finite element (FE) model using finite element analysis methods and to identify optimal loading conditions to simulate masticatory movement. A three-dimensional FE model of the maxillary and mandibular cortical bone, cancellous bone, and gingiva was constructed based on edentulous cone-beam-computed tomography data. Dental computer-aided design software was used to design the denture base and artificial teeth to produce a complete denture. Mesh convergence was performed to derive the optimal mesh size, and validation was conducted through comparison with mechanical test results. The mandible was rotated step-by-step to induce movements similar to actual mastication. Results showed that there was less than a 6% difference between the mechanical test and the alveolar bone-complete denture. It opened 10° as set in the first stage, confirming that the mouth closed 7° in the second stage. Occlusal contact occurred between the upper and lower artificial teeth as the mouth closed the remaining angle of 3° in the third stage while activating the masseter muscle. These results indicate that the FE model and masticatory loading conditions developed in this study can be applied to analyze biomechanical effects according to the wearing of dentures with various design elements applied.

11.
J Pharm Bioallied Sci ; 16(Suppl 1): S877-S879, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595486

RESUMEN

This study is the first study to incorporate a novel approach to single-implant-retained mandibular overdenture with a bar attachment on a single implant in the symphysis region. The use of a single-implant-retained bar overdenture significantly improved patients' chewing efficiency, indicating enhanced overdenture retention and stability. Materials and Methods: Ten maxillary and mandibular completely edentulous patients were enrolled in the study. A complete denture was fabricated for them. On completion, bite force, retention force, and bone change were recorded. Bite force was recorded with the strain gauge, retention force with the force measurement gauge, and bone changes with radiographs. Conclusion: Single-implant-supported bar mandibular overdenture (SISBOD) can be a suitable standard economic option for edentulous mandible and can greatly improve the quality of life of patients.

12.
Cureus ; 16(2): e54938, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38544582

RESUMEN

Complete denture is a real challenge for any practitioner. The aim of implantology is to optimize prosthetic balance and ensure that prostheses are perfectly integrated from a bio-functional viewpoint, despite an unfavorable anatomophysiological context. Here, we present a case managed in our department concerning a mandibular complete removable denture retained by a medial symphyseal implant. A 61-year-old fully edentulous mandibular patient with a Kennedy Applegate class I edentulous maxilla in good general health consulted for the renewal of his mandibular complete denture, which was deemed unstable and non-retentive. The exo-oral examination was normal. The mandibular crest was heavily resorbed, especially posteriorly, and covered with slightly inflammatory fibromucosa. The patient refused bone augmentation surgery. We performed a piezographic mandibular prosthesis retained by a single standard implant at the level of the mandibular symphysis. The prosthesis was stable and retentive. Masticatory comfort and efficiency were satisfactory and the psychological integration of the prosthesis was improved. Several studies have shown that a single symphyseal implant is a therapeutic alternative that completes the therapeutic range in specific cases. It should be limited to the mandibular arch in elderly patients with reduced bone volume. Given the lack of randomized controlled trials, routine use of this new approach is not recommended, and further studies are required.

13.
Cureus ; 16(1): e51833, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38327924

RESUMEN

AIM: The goal of this research was to facilitate dialogue and interaction among a group of dental practitioners about their views on denture adhesives, with the objective of reaching a collective consensus through the application of the Delphi Method. METHODS: This investigation employed the Delphi Technique, involving multiple rounds of questionnaires sent to a panel of experts. The objective was to establish a consensus (defined as over 70% agreement) or to explore the different viewpoints on the subject. A comprehensive Delphi questionnaire comprising 22 items was distributed to the Dental Practitioners. The questionnaire covered five key areas concerning denture adhesives: (1) overall perceptions; (2) the role in the development of clinical conditions; (3) specific applications and potential misuses; (4) their importance in denture services, including educating patients about denture adhesives; and (5) a general assessment of their clinical applications. RESULTS: All 31 panellists, chosen randomly, unanimously agreed to participate, with each of them actively involved in all three rounds of the survey. The panellists reached a consensus and definitively concluded that denture adhesives (1) are beneficial for enhancing the fit and comfort of the prosthesis and are not used to mask the underlying denture problems; (2) cause diseases such as denture stomatitis, candidiasis, and resorption of alveolar bone; (3) have the potential for increasing retention, function, and reducing patient anxiety. However, the panellists did not achieve a consensus on whether denture adhesives cause nausea and gagging in the patients; (4) education is very important for patients with both ill-fitting and well-fitting dentures; (5) are a beneficial adjunct to dentists when fabricating dentures. CONCLUSION: The expert panel of distinguished dental practitioners determined that denture adhesives play a valuable supportive role in the field of denture prosthetics, serving important functions during both the creation and post-insertion stages of dentures.

14.
Cureus ; 16(1): e52486, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38371006

RESUMEN

The absence of teeth, known as edentulism, poses considerable obstacles in prosthodontic care and greatly affects a person's well-being. Conventional complete dentures frequently lead to problems like instability and insufficient retention, especially in the lower jaw. Fortunately, the introduction of dental implants has transformed the way we approach edentulous patients, as they now offer support and enhanced retention for removable prostheses, thus revolutionizing their treatment. While a consensus exists on using two implants for retaining mandibular overdentures, the associated cost may be prohibitive for economically disadvantaged individuals. As a solution, the concept of single implant-retained mandibular overdentures has emerged, catering to individuals with limited financial resources and complete tooth loss. This review explores the efficacy and suitability of the single implant overdenture approach, along with an overview of treatment options for edentulous patients, including traditional dentures, tooth-supported overdentures, and implant-supported overdentures. The preservation of bone, improvements in functional abilities, and psychological benefits associated with overdentures are discussed. Moreover, various classifications and prosthetic options for implant overdentures, specifically for mandibular cases, are presented. This literature review aims to provide a comprehensive understanding of possible treatment options and focus on the single implant-retained mandibular overdenture approach and its implications in prosthodontic rehabilitation for edentulous patients.

15.
J Prosthodont Res ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38382972

RESUMEN

PURPOSE: This systematic review examined the effectiveness of soft denture relining (SDR) materials. STUDY SELECTION: A comprehensive search of MEDLINE, Cochrane Library, and ICHUSHI was conducted up to July 26, 2020. Target outcomes were patient satisfaction, oral health-related quality of life (OHRQOL), masticatory ability (MA), denture functional duration, residual ridge resorption (RRR), and microbial contamination. An organization specializing in literature searches performed the reference searches, and two reviewers independently selected the literature sources, extracted the data, and assessed the risk of bias. The reviewers resolved any disagreements concerning the assortment of literature sources through discussion. SDR included acrylic- and silicone-based materials, which were evaluated separately. RESULTS: Reviewers selected 7, 5, 11, 1, 4, and 6 studies to assess patient satisfaction, OHRQOL, MA, functional duration, RRR, and microbial contamination, respectively. The results confirmed that SDR improved patient satisfaction, OHRQOL, MA, and RRR. However, the functional duration of SDR material is shorter than that of hard denture relining (HDR) or acrylic resin material. Furthermore, SDR material is more susceptible to microbial contamination in the long term. The risk of bias for the included studies tended to be high because of specific issues (difficulty in blinding SDR versus HDR). CONCLUSIONS: For patients who wear complete dentures, SDR often provides beneficial outcomes such as pain reduction and recovery from MA. However, caution should be exercised regarding their use owing to insufficient functional duration and the possibility of microbial contamination during long-term use.

16.
Oral Health Prev Dent ; 22(1): 123-130, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38376436

RESUMEN

PURPOSE: When carrying out prosthetic rehabilitation of edentulous and partially edentulous patients, great attention is paid to the personal attitude of the patients, their satisfaction with oral health and psychosocial interaction due to tooth loss, as well as the treatment of the resulting disorders. This attention has led to the development of various instruments for examining the quality of life related to oral health. The aim of this study was to develop and validate a reliable instrument in the Serbian language suitable for measuring oral health-related quality of life in patients who have been rehabilitated with complete or partial dentures. Мaterials and Methods: The study was unicentric and cross-sectional, and assessed the reliability and validity of a newly developed instrument for measuring the oral health-related quality of life in denture wearers (OHRQoL-DW). It was conducted on a sample of 200 adults from Serbia, wearers of various types of dentures, with a mean age 66.9 ± 10.3 years and male/female ratio of 86/114 (43%/57%). RESULTS: The definitive version of the OHRQoL-DW scale with 28 items showed very good reliability, with Cronbach's alpha = 0.938. Good temporal stability of the questionnaire was demonstrated, and satisfactory results were obtained for divergent and convergent validity tests. Exploratory factorial analysis revealed four domains of oral health-related quality of life in denture wearers: physical, psychosocial, environmental and aesthetic. CONCLUSIONS: The OHRQoL-DW scale is a reliable and valid generic instrument for measuring the oral health-related quality of life in patients wearing dentures, which is one of the most important outcomes of oral health in prosthetic treatment.


Asunto(s)
Salud Bucal , Calidad de Vida , Adulto , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios Transversales , Reproducibilidad de los Resultados , Dentaduras
17.
Gerodontology ; 2024 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-38247020

RESUMEN

OBJECTIVE: To evaluate clinical parameters that affect the performance of root-supported overdentures (ROD) and to identify the possible factors that may affect it. BACKGROUND: ROD still serve as an alternative and successful treatment plan nowadays for partially edentulous patients. Nonetheless, there is not yet conclusive evidence about their clinical evaluation. MATERIALS AND METHODS: A search strategy was developed following a PIO (Population, Intervention, Outcome) framework including an electronic search in the following databases: PubMed, Cochrane Library and Scopus. The systematic search included only randomised controlled clinical trials (RCTs), published until January 2023 in English language and was performed by two independent reviewers. Quality assessment of the included studies was conducted according to the Cochrane Risk of Bias tool. RESULTS: The final selection of studies included 11 RCTs. Clinically relevant variables derived from this search were: Complications, with caries being the most frequently reported, periodontal aspects and bone changes around abutment teeth. Additionally, methods and clinical suggestions for the maintenance of these restorations and patient-related outcomes were assessed. According to the risk of bias assessment, nine studies were considered of high risk, whereas only 2 of low risk. A meta-analysis was not feasible. CONCLUSION: Within the limitations of this systematic review, ROD remain a viable treatment plan, offering better denture stability and bone preservation around abutment teeth and high patient satisfaction. Thorough oral hygiene and regular follow-ups are of utmost importance. Further well-designed RCTs are necessary for firmer conclusions.

18.
Spec Care Dentist ; 44(1): 124-129, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37013961

RESUMEN

OBJECTIVE: To present clinical strategies for prosthetic rehabilitation with complete dentures (CDs) of a Parkinson's disease patient. CASE REPORT: An 82-year-old patient sought the Department of Dentistry at UFRN, reporting retention dissatisfaction and hamper to the mandibular CD adaptation. Patient-reported a dry mouth sensation, and exhibited disordered mandibular movements, tremors, and resorbed mandibular ridge. Aiming retention and stability, double molding with zinc enolic oxide impression paste, neutral zone technique, and non-anatomic teeth were proposed as clinical strategies. At delivery, identification and relief in the supercompression areas were performed to facilitate the acceptance and use of the new dentures. CONCLUSION: The strategies promoted patient satisfaction regarding retention, stability, and comfort. This treatment may be considered for the rehabilitation of Parkinson's disease patients, favoring the adaptation process.


Asunto(s)
Enfermedad de Parkinson , Humanos , Anciano de 80 o más Años , Enfermedad de Parkinson/complicaciones , Diseño de Dentadura/métodos , Retención de Dentadura/métodos , Dentadura Completa , Satisfacción del Paciente
19.
J Prosthodont ; 33(1): 27-33, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37200587

RESUMEN

PURPOSE: To assess, clinically, patient satisfaction of additively manufactured complete dentures with intraoral scanning and hybrid cast digitization in comparison with conventional complete dentures. MATERIALS AND METHODS: Participants who were edentulous in both arches were recruited and received three types of complete dentures (CDs): conventionally manufactured with conventional impression (CC), additively manufactured with intraoral scanning (AMI), and additively manufactured with cast digitization (AMH). Definitive impressions of the edentulous arches were made with medium viscosity polyvinyl siloxane (Hydrorise Monophase; Zhermack, Italy) for the CC group, intraoral scanning (TRIOS 4; 3Shape, Copenhagen, Denmark) for the AMI group, and laboratory scanning of the definitive casts (Ceramill Map400 AMANNGIRRBACH, Pforzheim, Deutschland) for the AMH group. The trial dentures of the CC group were scanned for occlusion registrations of the AMI and AMH groups and were used to guide the designing process (Exocad 3.0 Galway; Exocad GmbH). The AMI and AMH dentures were additively manufactured with a vat-polymerization 3D printer (Sonic XL 4K; phrozen, Taiwan). Patient satisfaction and clinical outcome were assessed with OHIP EDENT, and 14-factor criteria, respectively. Statistical analyses were performed with paired sample t-test and one-way repeated measure ANOVA for satisfaction, Wilcoxon signed rank test for clinical outcome, and Pearson's r (r) for effect size, with α = 0.05. RESULTS: A total of 20 participants were included. Satisfaction had no statistically significant difference within or among the groups (p < 0.105). Within-group comparison between the two arches showed no statistical significance for the clinical outcome except for a significantly higher maxillary AMI score (p = 0.01, r = -0.40 with medium effect size). For among group's comparison; AMI had a significantly lower score than CC for the maxillary and mandibular arches (p = 0.01, r = -0.40, medium effect size, and p = 0.003, r = -0.47, medium effect size), and significantly lower score than the mandibular AMH (p = 0.03, r = -0.47, medium effect size), with significantly lower quality in teeth arrangement and retention domains for the AMI, and teeth arrangement for the AMH, in comparison with CC. CONCLUSIONS: Patient satisfaction with both types of additively manufactured dentures is comparable to conventional dentures. The comparable overall clinical outcomes between hybrid and conventional dentures indicate that additive manufacturing is an acceptable clinical substitute for the conventional methods. However, additively manufactured dentures made with intraoral scanning have lower clinical quality and retention than hybrid and conventional dentures, particularly for the mandibular arch. Teeth arrangement of both additively manufactured dentures is clinically inferior to the conventional denture.


Asunto(s)
Dentadura Completa , Boca Edéntula , Humanos , Diseño Asistido por Computadora , Satisfacción del Paciente
20.
J Prosthodont Res ; 68(1): 132-138, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-37316261

RESUMEN

PURPOSE: The purpose of this study is to investigate the effects of denture adhesives on masticatory performance via a 10-center, parallel, randomized, controlled trial of complete denture wearers in Japan. METHODS: The trial was conducted between September 2013 and October 2016. The inclusion criteria were complete edentulism, willingness to undergo new complete denture treatment, and willingness to return for recall treatment. The exclusion criteria were age 90 years or older, presence of severe systemic illness, inability to understand the questionnaires, wearing metal base complete dentures, denture adhesive user, wearing prosthetics for maxillofacial defects, wearing complete dentures with tissue conditioners, and severe xerostomia. Randomization of the powder-type denture adhesive (powder), cream-type denture adhesive (cream), and control (saline) groups was performed using a sealed envelope system. Masticatory performance was measured using color-changeable chewing gum. Intervention blinding was not feasible. RESULTS: Sixty-seven control, 69 powder, and 64 cream participants are analyzed using the intention-to-treat principle. The participants in all groups show significantly improved masticatory performance at post-intervention (paired t-test with Bonferroni correction P < 0.0001). However, no significant difference in masticatory performance is detected among the three groups (one-way analysis of variance). A significant negative correlation between pre- and post-changes in masticatory performance and intraoral condition scores is observed (Pearson's correlation coefficient, P < 0.0001). CONCLUSIONS: Although denture adhesives improved the masticatory performance of complete denture wearers, their clinical effects are comparable to those of saline solution. The use of denture adhesives is more effective in complete denture wearers with unsatisfactory intraoral conditions.


Asunto(s)
Boca Edéntula , Pérdida de Diente , Humanos , Anciano de 80 o más Años , Polvos , Dentadura Completa , Goma de Mascar , Masticación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...