Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 880
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38946145

RESUMEN

INTRODUCTION: This is the first systematic review and meta-analysis to investigate the effectiveness of the nasal airflow-inducing maneuver (NAIM) in olfactory rehabilitation for total laryngectomy (TL) patients. METHODS: We conducted a systematic literature search following Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The inclusion criteria required that patients must have undergone a TL with subsequent NAIM training for at least 2 weeks and olfactory evaluation. The impact of NAIM on olfactory outcomes compared to that at baseline was measured. Olfactory measures included the Sniffin' Sticks Test, Smell Disk Test, Scandinavian Odor Identification Test, and Quick Odor Detection Test. The primary outcome measures were the proportion of patients with normosmia at baseline and after intervention. RESULTS: Seven studies from 2000 to 2023 comprising a total of 290 TL patients met the inclusion criteria. The meta-analysis revealed that prior to intervention, the pooled proportion of patients with normosmia was 0.16 (95% confidence interval [CI]: 0.09‒0.27, p = 0.01). After intervention, the same proportion increased to 0.55 (95% CI: 0.45‒0.68, p = 0.001). Among the included patients, 88.3% were initially anosmic or hyposmic, which was reduced to 48.9% after NAIM practice, with 51.1% achieving normosmia. The percent improvement was not found to be significantly associated with the timing of intervention post-TL (p = 0.18). CONCLUSIONS: NAIM increased the proportion of patients who achieved normosmia in TL patients. NAIM stands out as a safe, easily teachable maneuver with promising results. Further efforts are warranted to provide specific recommendations and guidelines for the use of NAIM in clinical practice.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38953771

RESUMEN

OBJECTIVES: One stage functional jaw reconstruction is defined as the resection and reconstruction of segmental defects in conjunction with the placement of dental implants in an ideal prosthetic position and loaded with a provisional restoration, during one surgical procedure. The aim of the study is to describe clinical outcomes of patients who underwent one stage functional jaw reconstruction. METHODS: Patients who underwent one-stage functional jaw reconstruction, from January 2013 to March 2016 were recalled in 2022 and 2023. Planning and execution for the reconstruction utilized either analogue or digital techniques. Outcome parameters recorded were treatment-related outcomes at patient level, implant-related outcomes and patient-reported outcome measures. RESULTS: Eighteen patients underwent one-stage jaw reconstruction with a total of 57 implants. Four patients had maxillary and 14 had mandibular reconstructions. Ten patients underwent postoperative radiotherapy. Ten patients were planned using analogue and eight by digital planning. Three patients had partial flap necrosis, three patients had plate fractures, implant loss was seen in one patient and four patients died during the period. A functional prosthesis was provided in 16 out of the 18 patients. CONCLUSION: One-stage functional jaw reconstruction is a predictable method for providing rehabilitation with successful outcomes at 7-11 years. However, caution should be exercised when the treatment modality is carried out in patients with malignant pathologies who have undergone radiotherapy.

3.
J Dent ; : 105131, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38950765

RESUMEN

OBJECTIVES: Digital protocols and bioactive materials may reduce complications and improve tooth autotransplantation (ATT) success and survival rates. This prospective study assesses the performance of a fully digital autotransplantation protocol of close-apex molars with the adjunctive application of Enamel Matrix Derivatives (EMD). METHODS: Twelve adult patients with 13 hopeless molar teeth were replaced with autotransplantation of closed apex third molars. Outcomes, including success and survival rates, clinical, endodontic, radiographic, patient-reported outcome measures (PROMs), and digital image assessments, were conducted over a two-year follow-up period. RESULTS: Survival and success rates were 100% and 91.2%, respectively, with no progressive inflammatory or replacement root resorption (ankylosis) except for one tooth presenting radiographic furcation involvement. A significant probing depth reduction of 2.4 ± 2.58 mm and CAL gains of 2.8 ± 3.03 mm were observed in transplanted teeth compared to the hopeless receptor teeth. Radiographic bone levels remained stable throughout the study period (-0.37 ± 0.66 mm), and digital image assessments showed minimal alveolar ridge width changes (-0.32 to -0.7 mm) and gingival margin changes (-0.95 to -1.27 mm) from baseline to last visit. PROMs indicated very high patient satisfaction. CONCLUSION: The use of a digital ATT protocol with adjunctive use of EMD in closed-apex third molars demonstrated promising short-term high success and survival rates. Additionally, this type of therapy adequately preserves the dimensions of the alveolar ridge in the receptor site.

4.
J Neurol Surg B Skull Base ; 85(4): 363-369, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38966300

RESUMEN

Objective The aim of this work was the development of an augmented reality system including the functionality of conventional surgical navigation systems. Methods An application software for the Augmented Reality System HoloLens 2 from Microsoft was developed. It detects the position of the patient as well as position of surgical instruments in real time and displays it within the two-dimensional (2D) magnetic resonance imaging or computed tomography (CT) images. The surgical pointer instrument, including a pattern that is recognized by the HoloLens 2 sensors, was created with three-dimensional (3D) printing. The technical concept was demonstrated at a cadaver skull to identify anatomical landmarks. Results With the help of the HoloLens 2 and its sensors, the real-time position of the surgical pointer instrument could be shown. The position of the 3D-printed pointer with colored pattern could be recognized within 2D-CT images when stationary and in motion at a cadaver skull. Feasibility could be demonstrated for the clinical application of transsphenoidal pituitary surgery. Conclusion The HoloLens 2 has a high potential for use as a surgical navigation system. With subsequent studies, a further accuracy evaluation will be performed receiving valid data for comparison with conventional surgical navigation systems. In addition to transsphenoidal pituitary surgery, it could be also applied for other surgical disciplines.

5.
J Pers Med ; 14(6)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38929810

RESUMEN

Total knee arthroplasty (TKA) is a gold standard surgical procedure to improve pain and restore function in patients affected by moderate-to-severe severe gonarthrosis refractory to conservative treatments. Indeed, millions of these procedures are conducted yearly worldwide, with their number expected to increase in an ageing and more demanding population. Despite the progress that has been made in optimizing surgical techniques, prosthetic designs, and durability, up to 20% of patients are dissatisfied by the procedure or still report knee pain. From this perspective, the introduction of robotic TKA (R-TKA) in the late 1990s represented a valuable instrument in performing more accurate bone cuts and improving clinical outcomes. On the other hand, prolonged operative time, increased complications, and high costs of the devices slow down the diffusion of R-TKA. The advent of newer technological devices, including those using navigation systems, has made robotic surgery in the operatory room more common since the last decade. At present, many different robots are available, representing promising solutions to avoid persistent knee pain after TKA. We hereby describe their functionality, analyze potential benefits, and hint at future perspectives in this promising field.

6.
J Dent ; 147: 105130, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38878813

RESUMEN

OBJECTIVES: Segmentation of anatomical structures on dento-maxillo-facial (DMF) computed tomography (CT) or cone beam computed tomography (CBCT) scans is increasingly needed in digital dentistry. The main aim of this research was to propose and evaluate a novel open source tool called DentalSegmentator for fully automatic segmentation of five anatomical structures on DMF CT and CBCT scans: maxilla/upper skull, mandible, upper teeth, lower teeth, and the mandibular canal. METHODS: A retrospective sample of 470 CT and CBCT scans was used as a training/validation set. The performance and generalizability of the tool was evaluated by comparing segmentations provided by experts and automatic segmentations in two hold-out test datasets: an internal dataset of 133 CT and CBCT scans acquired before orthognathic surgery and an external dataset of 123 CBCT scans randomly sampled from routine examinations in 5 institutions. RESULTS: The mean overall results in the internal test dataset (n = 133) were a Dice similarity coefficient (DSC) of 92.2 ± 6.3 % and a normalised surface distance (NSD) of 98.2 ± 2.2 %. The mean overall results on the external test dataset (n = 123) were a DSC of 94.2 ± 7.4 % and a NSD of 98.4 ± 3.6 %. CONCLUSIONS: The results obtained from this highly diverse dataset demonstrate that this tool can provide fully automatic and robust multiclass segmentation for DMF CT and CBCT scans. To encourage the clinical deployment of DentalSegmentator, the pre-trained nnU-Net model has been made publicly available along with an extension for the 3D Slicer software. CLINICAL SIGNIFICANCE: DentalSegmentator open source 3D Slicer extension provides a free, robust, and easy-to-use approach to obtaining patient-specific three-dimensional models from CT and CBCT scans. These models serve various purposes in a digital dentistry workflow, such as visualization, treatment planning, intervention, and follow-up.

7.
J Dent ; 147: 105110, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38906453

RESUMEN

OBJECTIVE: This randomized clinical trial aimed to assess the feasibility of computer-assisted open exposure of palatally impacted canines. MATERIALS AND METHODS: Patients aged 11-30 years who required orthodontic eruption for the full palatal impaction of their canines were included in this study. Exclusion criteria were psychosocial and dental contraindications of orthodontic treatment, congenital craniofacial disorders, and trauma in the patient's history in the vicinity of the surgical site. Virtual planning software was used to register the intraoral scans and cone-beam computed tomography data and to design a surgical template. In the test group, exposure of the canines was guided by a surgical template, whereas in the control group, the surgeon relied on the surgical plan to localize the impacted canine. The success of the intervention, duration of surgery, and complications, including excessive hemorrhage, damage to the canine or neighboring anatomical landmarks, and postoperative inflammation of the surgical site were assessed. Postoperative pain was reported by the patients using the visual analog pain scale (VAS). RESULTS: Surgery was deemed successful in all patients in both groups. During healing, no complications were observed. The duration of surgery decreased significantly in the test group (4 min 45.1 s ± 1 min 8.4 s) compared to that in the control group (7 min 22.3 s ± 56.02 s). No statistically significant differences were observed between the VAS scores of the two study groups. CONCLUSIONS: The application of virtual planning and static navigation is a viable approach for the open exposure of palatally impacted canines. CLINICAL TRIAL REGISTRATION NUMBER: NCT05909254. CLINICAL SIGNIFICANCE: Computer-assisted surgery is a feasible method for open exposure of palatally impacted canines, which decreases the duration of surgery compared to the freehand method.

8.
J Clin Med ; 13(11)2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38892836

RESUMEN

Background: Total Knee Arthroplasty (TKA) is a prevalent surgical procedure for treating severe knee arthritis, aiming to alleviate pain and restore function. Recent advancements have introduced computer-assisted (CAS) and robot-assisted (RA-TKA) surgical techniques as alternatives to conventional methods, promising improved accuracy and patient outcomes. However, comprehensive comparative studies evaluating the short-term outcomes and prostheses survivorship among these techniques are limited. We hypothesized that the outcome of RA-TKA and/or CAS- TKA is advantageous in function and prosthesis survivorship compared to manually implanted prostheses. Methods: This prospective controlled study compared the short-term outcomes and prostheses survivorship following TKA using conventional, CAS, and RA-TKA techniques. One hundred seventy-eight patients requiring TKA were randomly assigned to one of the three surgical groups. The primary outcomes were knee function (KSS knee score) and functional recovery (KSS function score), which were assessed before surgery three years postoperatively. Secondary outcomes included prosthesis alignment, knee range of movements, and complication rates. Survivorship analysis was conducted using Kaplan-Meier curves, with revision surgery as the endpoint. Results: While all three groups showed significant improvements in knee function postoperatively (p < 0.001), the CAS and RA-TKA groups demonstrated superior prosthetic alignment and higher survivorship rates than the conventional group (100%, 97%, and 96%, respectively). However, although the RA-TKA group had a maximal 100% survivorship rate, its knee score was significantly lower than following CAS and conventional techniques (mean 91 ± 3SD vs. mean 93 ± 3SD, p = 0.011). Conclusion: The RA-TKA technique offers advantages over conventional and CAS methods regarding alignment accuracy and short-term survivorship of TKA prostheses. Since short-term prosthesis survivorship indicates the foreseen rates of mid- and long-term survivorship, the current data have a promising indication of the improved TKA prosthesis's long-term survivorship by implementing RA-TKA. According to the presented data, although the survival rates were 100%, 97%, and 96% in the three study groups, no clinical difference in the functional outcome was found despite the better mechanical alignment and higher survivorship in the group of patients treated by the RA-TKA.

9.
J Dent ; : 105150, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38909646

RESUMEN

OBJECTIVES: To compare the accuracy and operative time of implant placement using a dynamic computer assisted implant surgery (dCAIS) system based on a cone beam computer tomography (CBCT) image, with and without superimposing a standard tessellation language (STL) file of an intraoral scan of the patient. METHODS: Ten identical resin models simulating an upper maxilla with posterior edentulism were assigned to two groups. In the CBCT+STL group, a CBCT file and an intraoral STL file were superimposed and used for registration; in the CBCT group, registration was performed using CBCT images. Six implants were placed in each model using the Navident® dynamic navigation system. Anatomy registration was performed by tracing points on the CBCT or STL image, depending on the group. Preoperative and postoperative CBCT images were overlaid to assess implant placement accuracy. RESULTS: Sixty implants were analyzed (30 implants in each group). 3D platform deviation was significantly lower (mean difference (MD): 0.17 mm; 95% confidence interval (CI): 0.01 to 0.23; P = 0.039) in the CBCT+STL group (mean: 0.71mm; standard deviation (SD): 0.29) than in the CBCT group (mean: 0.88mm; SD: 0.39). The remaining accuracy outcome variables (angular deviation MD: -0.01; platform lateral deviation MD: 0.08mm; apex global MD: 0.01mm; apex depth MD: 0.33mm) and surgery time (MD: 3.383 min.) were similar in both groups (p>0.05). CONCLUSIONS: The introduction of an intraoral scan (STL) seems to reduce deviations slightly in dental implant placement with dCAIS systems. However, the clinical repercussion of this improvement is questionable. CLINICAL SIGNIFICANCE: Superimposing an intraoral scan on the CBCT image does not seem to increase the accuracy of dCAIS systems but can be useful when radiographic artifacts are present.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38896405

RESUMEN

PURPOSE: The conventional method to reconstruct the bone level for orbital defects, which is based on mirroring and manual adaptation, is time-consuming and the accuracy highly depends on the expertise of the clinical engineer. The aim of this study is to propose and evaluate an automated reconstruction method utilizing a Gaussian process morphable model (GPMM). METHODS: Sixty-five Computed Tomography (CT) scans of healthy midfaces were used to create a GPMM that can model shape variations of the orbital region. Parameter optimization was performed by evaluating several quantitative metrics inspired on the shape modeling literature, e.g. generalization and specificity. The reconstruction error was estimated by reconstructing artificial defects created in orbits from fifteen CT scans that were not included in the GPMM. The developed algorithms utilize the existing framework of Gaussian process morphable models, as implemented in the Scalismo software. RESULTS: By evaluating the proposed quality metrics, adequate parameters are chosen for non-rigid registration and reconstruction. The resulting median reconstruction error using the GPMM was lower (0.35 ± 0.16 mm) compared to the mirroring method (0.52 ± 0.18 mm). In addition, the GPMM-based reconstruction is automated and can be applied to large bilateral defects with a median reconstruction error of 0.39 ± 0.11 mm. CONCLUSION: The GPMM-based reconstruction proves to be less time-consuming and more accurate than reconstruction by mirroring. Further validation through clinical studies on patients with orbital defects is warranted. Nevertheless, the results underscore the potential of GPMM-based reconstruction as a promising alternative for designing patient-specific implants.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38839534

RESUMEN

Surgical navigation, despite its potential benefits, faces challenges in widespread adoption in clinical practice. Possible reasons include the high cost, increased surgery time, attention shifts during surgery, and the mental task of mapping from the monitor to the patient. To address these challenges, a portable, all-in-one surgical navigation system using augmented reality (AR) was developed, and its feasibility and accuracy were investigated. The system achieves AR visualization by capturing a live video stream of the actual surgical field using a visible light camera and merging it with preoperative virtual images. A skull model with reference spheres was used to evaluate the accuracy. After registration, virtual models were overlaid on the real skull model. The discrepancies between the centres of the real spheres and the virtual model were measured to assess the AR visualization accuracy. This AR surgical navigation system demonstrated precise AR visualization, with an overall overlap error of 0.53 ± 0.21 mm. By seamlessly integrating the preoperative virtual plan with the intraoperative field of view in a single view, this novel AR navigation system could provide a feasible solution for the use of AR visualization to guide the surgeon in performing the operation as planned.

12.
Arch Orthop Trauma Surg ; 144(6): 2865-2872, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38753013

RESUMEN

INTRODUCTION: The accuracy of acetabular cup placement using conventional portable imageless navigation systems in total hip arthroplasty (THA) in the lateral decubitus position remains challenging. Several novel portable imageless navigation systems have been developed recently to improve cup placement accuracy in THA. This study compared the accuracy of acetabular cup placement using a conventional accelerometer-based portable navigation (c-APN) system and a novel accelerometer-based portable navigation (n-APN) system during THA in the lateral decubitus position. MATERIALS AND METHODS: This retrospective cohort study compared 45 THAs using the c-APN and 45 THAs using the n-APN system. The primary outcomes were the absolute errors between the intraoperative and postoperative values of acetabular cup radiographic inclination and anteversion angles and the percentage of cases with absolute errors within 5°. Intraoperative values were shown on navigation systems, and postoperative measurements were conducted using computed tomography images. RESULTS: The median absolute errors of the cup inclination angles were significantly smaller in the n-APN group than in the c-APN group (3.9° [interquartile range 2.2°-6.0°] versus 2.2° [interquartile range 1.0°-3.3°]; P = 0.002). Additionally, the median absolute errors of the cup anteversion angles were significantly smaller in the n-APN group than in the c-APN group (4.4° [interquartile range 2.4°-6.5°] versus 1.9° [interquartile range 0.8°-2.7°]; P < 0.001). Significant differences were observed in the percentage of cases with absolute errors within 5° of inclination (c-APN group 67% versus n-APN group 84%; P = 0.049) and anteversion angles (c-APN group 62% versus n-APN group 91%; P = 0.001). CONCLUSIONS: The n-APN system improved the accuracy of the cup placement compared to the c-APN system for THA in the lateral decubitus position.


Asunto(s)
Acelerometría , Acetábulo , Artroplastia de Reemplazo de Cadera , Sistemas de Navegación Quirúrgica , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/instrumentación , Estudios Retrospectivos , Acetábulo/cirugía , Acetábulo/diagnóstico por imagen , Masculino , Femenino , Anciano , Persona de Mediana Edad , Acelerometría/métodos , Acelerometría/instrumentación , Posicionamiento del Paciente/métodos , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Prótesis de Cadera , Tomografía Computarizada por Rayos X/métodos
13.
J Dent ; : 105090, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38777103

RESUMEN

OBJECTIVES: To present a novel drilling protocol of trephine osteotomy technique for autologous bone grafting with simultaneous implant placement using an autonomous robotic system. METHODS: The novel protocol consists of 1) preoperative procedures: marker fabrication and fixation, data acquisition, and preoperative planning; 2) intraoperative procedures: registration and calibration, and osteotomy and implant placement performed by an autonomous dental implant robot; 3) postoperative procedures: CBCT acquisition and accuracy assessment. RESULT: The protocol was an effective method for implant osteotomy, with no reported intraoperative complications. The implant surgery was successfully completed, and autogenous bone was obtained. Meanwhile, the accuracy of implant placement was clinically acceptable, with minor deviations. CONCLUSIONS: Trephination-based robotic surgery can be successfully implemented in implant osteotomy, which might replace freehand implant surgery and conventional drilling protocol. However, further clinical studies are necessary. CLINICAL SIGNIFICANCE: The main finding of this case is a potential alternative for preserving autogenous bone during implant surgery.

14.
J Dent ; 146: 105072, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38763387

RESUMEN

OBJECTIVES: This study aimed to compare the effect the radiographic marker registration (RMR) and markerless tracing registration (MTR) on implant placement accuracy using a dynamic computer-assisted implant surgery system (dCAIS). Additionally, this study aimed to assess the surgical time and whether the implant location influences the accuracy of the two registration methods. METHODS: 136 dental implants were randomly allocated to the RMR or MTR group and were placed with a dCAIS in resin models. Preoperative and postoperative Cone Beam Computer Tomograms (CBCT) were overlaid and implant placement accuracy was assessed. Descriptive and multivariate analysis of the data was performed. RESULTS: Significant differences (P < 0.001) were found for all accuracy variables except angular deviation (RMR:4.30° (SD:4.37°); MTR:3.89° (SD:3.32°)). The RMR had a mean 3D platform deviation of 1.53 mm (SD:0.98 mm) and mean apex 3D deviation of 1.63 mm (SD:1.05 mm) while the MTR had lower values (0.83 mm (SD:0.67 mm) and 1.07 mm (SD:0.86 mm), respectively). In the MTR group, implant placement in the anterior mandible was more accurate (p < 0.05). Additionally, MTR did not significantly increase the surgical time compared with RMR (P = 0.489). CONCLUSIONS: MTR seems to increase the accuracy of implant placement using dCAIS in comparison with the RMR method, without increasing the surgical time. The operated area seems to be relevant and might influence the implant deviations. CLINICAL SIGNIFICANCE: Considering the limitations of this in-vitro study, MTR seems to provide a higher accuracy in implant placement using dCAIS without increasing the surgical time. Furthermore, this method does not require radiographic markers and allows re-registration during surgery.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Implantación Dental Endoósea , Implantes Dentales , Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada de Haz Cónico/métodos , Implantación Dental Endoósea/métodos , Marcadores Fiduciales , Imagenología Tridimensional/métodos
15.
BMC Oral Health ; 24(1): 560, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745168

RESUMEN

BACKGROUND: Solitary Bone Cyst (SBC), also known as a simple bone cyst, hemorrhagic cyst, or traumatic cyst is classified by the WHO among non-odontogenic benign lesions of the jaw. The article explores the use of a static 3D-printed surgical guide to treat mandibular SBC, emphasizing a minimally surgical approach for this lesion. CASE PRESENTATION: A 20-year-old woman was referred for a persistent mandibular SBC lacuna, without specific complaints. Her medical history included a previous bone trepanation for a SBC in the same area, radiologically and surgically confirmed. X-ray assessment showed a well-defined unilocular radiolucency surrounding the root of the first left lower molar (tooth #36), measuring 10 × 10 mm. Pulp sensitivity was normal. CBCT data and STL files of dental cast were obtained preoperatively and registered. A 3D-printed surgical guide was used for minimally invasive trepanation of the buccal cortical. The simulation used a targeted endodontic microsurgery approach in order to determine axis and diameter of the trephine. Surgery was performed under local anesthesia. The guide was tooth supported integrating tubes and a fork for guiding precise trepanation. A 3.5 mm round bone window was created, leaving an empty cavity confirming SBC diagnosis and permitting bone curettage. A blood clot was obtained to promote bone healing. Complete reossification was observed after 6 months. The follow-up at 2 years confirmed a complete bone healing with normal pulp sensitivity. DISCUSSION: The 3D-printed windowed surgical guide with dental support offers big advantages, including improved visibility and reduced errors. Compared to traditional guides, it eliminates visual hindrance and allows easier and quick access to confined areas as well as an improved irrigation during drilling process. The article also highlights the importance of preoperative planning while acknowledging potential limitations and errors and surgical complications. CONCLUSION: The use of the 3D-printed surgical guide could be used in routine for minimally invasive intervention of SBC. This case also demonstrates the potential utility of this approach in various procedures in oral and maxillofacial surgery. The technique provides precise localization, reducing complications and enhances operative efficiency.


Asunto(s)
Procedimientos Quirúrgicos Mínimamente Invasivos , Impresión Tridimensional , Humanos , Femenino , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Adulto Joven , Tomografía Computarizada de Haz Cónico , Enfermedades Mandibulares/cirugía , Enfermedades Mandibulares/diagnóstico por imagen , Quistes Maxilomandibulares/cirugía , Quistes Maxilomandibulares/diagnóstico por imagen
16.
J Dent ; 146: 105061, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38729289

RESUMEN

OBJECTIVES: Orthognathic surgery (OS) has evolved with technological advancements, notably through the implementation of computer-assisted orthognathic surgery (CAOS). This article aims to elucidate various types of CAOS and their efficiency and accuracy, supplemented by a thorough literature review focusing on their clinical applications in South Korea. STUDY SELECTION, DATA, AND SOURCES: A comprehensive search strategy was employed, including systematic reviews, meta-analyses, randomized controlled trials, and observational studies published until December 2023 in the PubMed, MEDLINE, and Google Scholar databases. The literature search was limited to articles written in English. RESULTS: Static CAOS demonstrated high precision, reduced operative time, and high accuracy, suggesting its potential reliability in orthognathic procedures. Dynamic CAOS presented a promising avenue for exploration, showing an accuracy comparable to that of traditional methods. The critical considerations for CAOS include accuracy, time efficiency, and cost-effectiveness. Recent studies have indicated advancements in the time efficiency of static CAOS. Static CAOS requires less equipment and is more cost-effective than dynamic CAOS. CONCLUSIONS: CAOS offers clear advantages over conventional OS in terms of surgical convenience and accuracy in implementing the surgical plan. To achieve recognition as the gold standard method for maxillofacial deformity treatment, CAOS must overcome its limitations and undergo continuous verification via well-designed studies. CLINICAL SIGNIFICANCE: The introduction of CAOS, mainly static CAOS with high precision and reduced surgical time, signifies a notable advancement in OS. However, rigorous studies are warranted to validate CAOS as the gold standard for treating maxillofacial deformities.


Asunto(s)
Procedimientos Quirúrgicos Ortognáticos , Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , República de Corea , Tempo Operativo
17.
J Dent ; 146: 105034, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38729287

RESUMEN

OBJECTIVE: To determine the current status and accuracy of robotic computer-assisted implant surgery (CAIS) applications by examining the associated clinical and experimental outcomes. DATA AND SOURCES: PubMed, Medline, and Cochrane Library databases were searched for relevant studies published between January 2000 and November 2023, and focusing on robotic CAIS in dental implant surgery. All search results were then manually reviewed to identify only the pertinent articles. Only in vitro and clinical studies were included in this narrative review, with implant placement accuracy considered the main outcome. RESULT: Based on our inclusion and exclusion criteria, we included 21 studies (with 1085 implant sites); of them, 8 were clinical studies, 12 were in vitro studies, and 1 included both an in vitro study and a case series. The ranges of the mean implant shoulder, apical, and angular deviations were respectively 0.43-1.04 mm, 0.53-1.06 mm, and 0.77°-3.77° in the clinical studies and 0.23-1.04 mm, 0.24-2.13 mm, and 0.43°-3.78° in the in vitro studies, respectively. CONCLUSION: The accuracy of robotic CAIS in dental implant procedures appears to be within the clinically acceptable ranges. However, further relevant clinical trials validating the existing evidence are needed. CLINICAL SIGNIFICANCE: Robotic CAIS can achieve clinically acceptable implant placement accuracy. This innovative technology may improve the precision and success rates of dental implant procedures, with benefit for surgeons and patients.


Asunto(s)
Implantación Dental Endoósea , Implantes Dentales , Procedimientos Quirúrgicos Robotizados , Cirugía Asistida por Computador , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Implantación Dental Endoósea/métodos , Cirugía Asistida por Computador/métodos , Implantación Dental/métodos
18.
Indian J Orthop ; 58(5): 503-509, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38694697

RESUMEN

Background: Total knee arthroplasty (TKA) is a reliable orthopedic procedure for knee osteoarthritis with long-term success rates of 90% after 15 years. Computer-assisted surgery (CAS) has been developed to improve the accuracy of the alignment and orientation of the components in TKA. Methods: A prospective study involving 103 subjects who underwent CAS-TKA was conducted over a 3-year period. Subjects were assessed for pre- and post-operative varus and valgus deformity, BMI, comorbidities, and Knee Society Score (KSS). Outcome measures of post-operative KSS, post-operative alignment, and hospital stay were examined by Spearman correlation coefficients. Categorical outcomes of complication and secondary procedures were compared by chi-squared test and odds ratio. Results: The study considered 103 TKA patients with a mean ± SD age of 63.7 ± 8.4 years (33-88 years). Unilateral knee replacement was performed on 56 patients (54.3%) and remaining 47 (45.6%) had simultaneous bilateral TKA. Forty (34.8%) patients were obese, and severe pre-operative deformity (> 15°) was observed in 47 (31.3%) patients. Mean coronal alignment of the knee joint was 91.33° (SD: 90.69° valgus-88.92° varus). The mean post-operative KSS noted in obese and non-obese subjects were 93.43 (84-98) and 94.76 (85-98) respectively. Post-operative KSS for knees with severe deformity was 94.08 (80-98), while it was 95.76 (83-98) in those with mild to moderate deformities. Conclusion: The study confirms that navigation in CAS-TKA consistently achieved coronal alignment of the knee joint within ± 3°, irrespective of the patient BMI and degree of deformity.

19.
J Korean Assoc Oral Maxillofac Surg ; 50(2): 70-79, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38693129

RESUMEN

Objectives: The surgical guide is a static computer-assisted device used for implant surgery planning and guidance. By taking an impression and referring to the patients' three-dimensional computed tomography scan of the desired implant site, a surgical guide can be created. During surgery, the surgical guide aids in achieving the designed implant placement position and direction. We examined and evaluated the long-term clinical outcomes of implant surgery using surgical guides. Materials and Methods: This study investigated a total of 15 patients with 32 implants that were placed using surgical guides from 2009 to 2011 with a mean follow-up period extended beyond 10 years. Patient demographics and implant survival rates were recorded. We analyzed marginal bone loss (MBL) by assessing the radiographs acquired at installation, three months after installation, and one month, one, two, and five years after prosthesis delivery. Results: The mean patient age was 57.33 years at implant placement. Of the 32 implants, five implants were placed in the anterior region and 27 implants were in the posterior region. Six implants failed and three of them were replaced, resulting in an 81.25% survival rate. The mean follow-up period was 10 years and nine months. Mean MBL compared to post-installation was significantly higher than at three months after installation, and one month, one, two, and five years after prosthesis delivery. Mean MBL at three months after installation, and one month, one year, and two years were significantly higher compared to the previous visit (P<0.05). However, MBL at five years after prosthesis delivery did not differ significantly compared to at two years. Conclusion: In this study, implant rehabilitation assisted by surgical guides exhibited favorable survival rates. With the limitation of the sample amount in this study, further research and more samples are required to evaluate the long-term clinical effectiveness of surgical guides.

20.
Artículo en Inglés | MEDLINE | ID: mdl-38702201

RESUMEN

The aim of this study was to investigate the stability of the proximal mandibular reference structures that have been proposed in the literature for superimposition. Forty proximal mandibular segments of 20 patients who underwent bilateral sagittal split osteotomy (BSSO) for advancement were reconstructed from a pair of pre- and postoperative (2 years) cone beam computed tomography scans, and spatially divided into the mandibular condyle, the coronoid process, and 20 mandibular ramus regions. To assess the stability of the anatomical regions, the volumetric and surface discrepancy between the superimposed pre- and postoperative regions were calculated. One-sample t-tests were applied to analyse the statistical stability of the individual regions. Two statistically stable (P < 0.05) structures in the proximal segment of the mandible following BSSO were identified: (1) the posterior part of the mandibular ramus above the gonial angle and below the condylar neck, and (2) the sub-coronoid area below the coronoid process/mandibular notch. Using these stable structures for superimposition resulted in an assessment discrepancy in the condylar displacement of up to 1.1 mm and in the volumetric change of up to 2.8%. Hence, it is suggested that these two identified stable structures are used as reference areas when assessing condylar displacement and change using superimposition.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...