Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 833
Filtrar
1.
J. optom. (Internet) ; 17(3): [100514], jul.-sept2024. tab
Artículo en Inglés | IBECS | ID: ibc-231876

RESUMEN

Purpose: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. Methods: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. Results: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. Conclusions: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Queratocono , Anteojos , Lentes de Contacto , Visión Binocular , Pruebas de Visión , Colombia , México , Oftalmología , Estudios Prospectivos
2.
J Eye Mov Res ; 17(1)2024.
Artículo en Inglés | MEDLINE | ID: mdl-38818405

RESUMEN

Many video-based eye trackers rely on detecting and tracking ocular features, a task that can be negatively affected by a number of individual or environmental factors. In this context, the aim of this study was to practically evaluate how the use of a scleral contact lens with two integrated nearinfrared lasers (denoted CLP) could improve the tracking robustness in difficult lighting conditions, particularly outdoor ones. We assessed the ability of the CLP (on a model eye) to detect the lasers and to deduce a gaze position with an accuracy better than 1° under four lighting conditions (1 lx, 250 lx, 50 klux and alternating 1lx /250 lx) on an artificial eye. These results were compared to the ability of a commercial eye tracker (Pupil Core) to detect the pupil on human eyes with a confidence score equal to or greater than 0.9. CLP provided good results in all conditions (tracking accuracy and detection rates). In comparison, the Pupil Core performed well in all indoor conditions (99% detection) but failed in outdoor conditions (9.85% detection). In conclusion, the CLP presents strong potential to improve the reliability of video-based eyetrackers in outdoor conditions by providing easy trackable feature.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38778634

RESUMEN

INTRODUCTION: Soft contact lenses may be a good alternative for early-stage keratoconus (KC) patients who do not tolerate rigid gas permeable (RGP) lenses due to ocular discomfort or complications. This prospective study compared outcomes obtained after 2 weeks of wearing two types of soft silicone hydrogel contact lenses for keratoconus that varied in their diameter and central thickness (cc). METHODS: Patients with Amsler-Krumeich grades I or II KC were fitted with small-diameter (14.2 or 14.8 mm) SoftK (SD-SoftK, cc = 0.48 mm) and large-diameter (17 mm) SoftK (LD-SoftK, cc = 0.60 mm) lenses, each worn for 2 weeks in a crossover design. Low (10%;10VA) and high (100%;100VA) contrast visual acuity, contrast sensitivity (CS, Pelli-Robson), higher order aberrations (HOAs, Visionix Vx130), the number of trial lens modifications during fitting and the subjectively preferred lens were compared using Friedman tests with post-hoc analysis. RESULTS: Forty eyes (N = 20, 10 males, mean age: 39.0 ± 9.9 years, range: 23-55 years) were examined. Their habitual median (interquartile1, interquartile3) 10VA (LogMAR), 100VA (LogMAR) and CS (LogCS) were 0.52 (0.30, 0.50), 0.14 (0.10, 0.15) and 1.35 (1.35, 1.50), respectively. For the SD-SoftK condition, the values were 0.23 (0.17, 0.30), 0.02 (0.00, 0.05) and 1.50 (1.50, 1.65), respectively. For the LD-SoftK condition, the respective values were 0.36 (0.27, 0.44), 0.09 (0.05, 0.13) and 1.50 (1.50, 1.60). SD-SoftK lenses significantly improved 10VA compared with habitual and LD-SoftK. SD-SoftK also significantly improved CS compared with habitual, but not LD-SoftK. LD-SoftK significantly improved spherical aberration compared with uncorrected (0.03 ± 0.10 µ vs. 0.07 ± 0.13 µ) but not SD-SoftK (0.04 ± 0.07 µ). Both lenses required a mean of 1.5 modifications prior to final lens fitting. Fewer adverse events were seen with SD-SoftK (N = 3) compared with LD-SoftK (N = 8), and 75% of participants preferred SD-SoftK lenses. CONCLUSION: SD-SoftK lenses were preferred by 75% of subjects, were associated with fewer adverse events and significantly improved 10VA compared with LD-SoftK lenses. SD-SoftK lenses also significantly improved CS compared with the habitual correction, but this did not differ significantly from the LD-SoftK lenses.

4.
Surv Ophthalmol ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38710236

RESUMEN

Advancements in diagnostic methods and surgical techniques for keratoconus (KC) have increased non-invasive treatment options. Successful surgical planning for KC involves a combination of clinical science, empirical evidence, and surgical expertise. Assessment of disease progression is crucial, and halting the progression should be the focus if it is progressive. While surgeons used to rely on experience alone to decide the surgical method, comparing the network of primary factors, such as visual acuity, across studies can help them choose the most appropriate treatments for each patient and achieve optimal outcomes. Meticulous tabulation methods facilitate interpretation, highlighting the importance of selecting the correct surgical and rehabilitation approach based on each patient's condition and stage of the disease. We detail the outcomes of a comprehensive network meta-analysis comparing the effectiveness of various combined therapeutic refractive treatments for KC at identical stages of the disease, spanning four distinct follow-up intervals. Additionally, the comprehensive analysis suggests that for corneas with optimal best corrected visual acuity (BCVA) preoperatively (classified as regular), combining phakic intraocular lenses with intracorneal ring segments (ICRS) and corneal cross-linking (CXL) could offer the best therapeutic approach provided the disease stage does not exceed stage 3. For irregular corneas, although initial follow-ups show a significant difference in BCVA with surface ablation, longer-term follow-ups recommend combining surface ablation with ICRS and CXL, especially at higher stages.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38712751

RESUMEN

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.

6.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
7.
Sci Rep ; 14(1): 11727, 2024 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778161

RESUMEN

The tear fluid is a readily accessible, potential source for biomarkers of disease and could be used to monitor the ocular response to contact lens (CL) wear or ophthalmic pathologies treated by therapeutic CLs. However, the tear fluid remains largely unexplored as a biomarker source for RNA-based molecular analyses. Using a rabbit model, this study sought to determine whether RNA could be collected from commercial CLs and whether the duration of CL wear would impact RNA recovery. The results were referenced to standardized strips of filtered paper (e.g., Shirmer Strips) placed in the inferior fornix. By performing total RNA isolation, precipitation, and amplification with commercial kits and RT-PCR methods, CLs were found to have no significant differences in RNA concentration and purity compared to Schirmer Strips. The study also identified genes that could be used to normalize RNA levels between tear samples. Of the potential control genes or housekeeping genes, GAPDH was the most stable. This study, which to our knowledge has never been done before, provides a methodology for the detection of RNA and gene expression changes from tear fluid that could be used to monitor or study eye diseases.


Asunto(s)
Lentes de Contacto , ARN , Lágrimas , Lágrimas/metabolismo , Animales , Conejos , ARN/aislamiento & purificación , ARN/genética , ARN/análisis
8.
Clin Optom (Auckl) ; 16: 93-100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38559802

RESUMEN

Introduction: Patients expect to have excellent vision and comfort when wearing soft contact lenses. The purpose of this study was to compare the wear experiences of participants with astigmatism when wearing a daily disposable soft toric lens to an established, commonly used reusable toric lens. Methods: In this crossover study, habitual soft toric lens wearers were fit with a daily replacement soft toric lens (delefilcon A) and a reusable, 1-month replacement soft toric lens (comfilcon A) in a randomized order. After 30 days of wear, Visual analog scale (VAS) surveys were used to assess wear experience, including vision and comfort, for overall wear and end-of-day wear. Scores were compared statistically with mixed-effects linear models. Participants also responded to questions about convenience, ease of use, and satisfaction with both lenses and preference questions based upon comfort, vision, and overall performance. Results: Fifty-nine participants completed the multi-site crossover study. VAS scores [mean(std dev)] for overall quality of vision for the delefilcon A [80.4(16.4)] and comfilcon A [66.8(27.7)] lenses were statistically significant (P=0.002). The difference in the mean overall comfort scores for the delefilcon A lenses [71.6(26.3)] and comfilcon A lenses [63.2(28.9)] was 8.4, which exceeds the establish criteria for clinical significance, although not statistically significant (P=0.08). Overall satisfaction scores were 68.8(26.9) for the delefilcon A and 59.7(30.3) for the comfilcon A lenses (P=0.08). Both lenses provided mean binocular visual acuities better than 20/20 Snellen equivalent. Over half of the participants preferred the delefilcon A lenses based upon comfort, vision, and overall performance. Convenience, ease of use, and satisfaction all scored higher with delefilcon A lenses. Conclusion: The results of this study show that wear experience with delefilcon A lenses for astigmatism can meet or exceed that of comfilcon A toric lenses while also providing healthy, daily disposable lens wear.

9.
Cont Lens Anterior Eye ; : 102158, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38631935

RESUMEN

This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike.

10.
Adv Mater ; : e2313848, 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38583064

RESUMEN

The increasing prevalence of dry eye syndrome in aging and digital societies compromises long-term contact lens (CL) wear and forces users to regular eye drop instillation to alleviate discomfort. Here a novel approach with the potential to improve and extend the lubrication properties of CLs is presented. This is achieved by embedding lubricant-secreting biofactories within the CL material. The self-replenishable reservoirs autonomously produce and release hyaluronic acid (HA), a natural lubrication and wetting agent, long term. The hydrogel matrix regulates the growth of the biofactories and the HA production, and allows the diffusion of nutrients and HA for at least 3 weeks. The continuous release of HA sustainably reduces the friction coefficient of the CL surface. A self-lubricating CL prototype is presented, where the functional biofactories are contained in a functional ring at the lens periphery, outside of the vision area. The device is cytocompatible and fulfils physicochemical requirements of commercial CLs. The fabrication process is compatible with current manufacturing processes of CLs for vision correction. It is envisioned that the durable-by-design approach in living CL could enable long-term wear comfort for CL users and minimize the need for lubricating eye drops.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38588998

RESUMEN

This 32-centre multicentre study addresses the lack of knowledge about the prevalence and significance of microbial keratitis (MK) associated with contact lens (CL) wear in Spain. A total of 304 cases recruited from 32 hospitals were studied and showed that infectious keratitis associated with contact lens wear mainly affects young women during the summer months. In this study, soft lenses with monthly replacement and single solution cleaning were most commonly used, purchased and fitted in opticians' shops. Common risk factors were identified among users, such as topping off solutions, prolonging the life of lenses, and frequently sleeping, swimming and showering with lenses. Overnight lens wear was significantly associated with a higher incidence of corneal opacities, and the presence of Pseudomonas aeruginosa in bacterial cultures was associated with more severe sequelae and a greater need for corneal transplantation. Although most cases were benign, the time taken to heal was long, which poses a problem for working patients. This study provides valuable epidemiological, microbiological and risk factor information and estimates the incidence of CL related MK in Spain to be approximately 1 case per 30,000 inhabitants per year.

12.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578134

RESUMEN

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Asunto(s)
Lentes de Contacto , Anteojos , Fijación Ocular , Presbiopía , Lectura , Refracción Ocular , Agudeza Visual , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimientos Oculares/fisiología , Fijación Ocular/fisiología , Movimientos de la Cabeza/fisiología , Presbiopía/fisiopatología , Presbiopía/terapia , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Estudios Cruzados , Estudios Prospectivos
13.
Cont Lens Anterior Eye ; 47(3): 102160, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38570253

RESUMEN

PURPOSE: To investigate the differences in contact lens sagittal depth (CL-SAG), base curve (BC), and overall lens diameter (OAD) of daily disposable (DD) SCLs at room temperature (20 °C) and on-eye (34 °C) temperature. METHODS: Twelve different spherical daily SCLs were analyzed (labeled power -3.00 D) at 20 °C and 34 °C. The posterior CL-SAG, BC, and OAD were measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS: The CL-SAG range for the daily disposable lenses measured at 20 °C was 3468-4016 µm. At 34 °C, the DD CL-SAG of all lenses individually decreased compared to 20 °C (t = 7.78, p < 0.001), ranging from 3385 to 3913 µm. On average at the higher temperature, the measured overall lens diameter was smaller (t = 8.18, p < 0.001) and the BC was marginally steeper (t = 2.11, p = 0.058). CONCLUSIONS: Soft lens parameters change when equilibrated from room temperature (20 °C) to on-eye temperature (34 °C). All lenses shrink when going to on-eye temperature (both lens diameter and CL-SAG decreases), compared to lenses measured at room temperature by ISO standards. Higher water content materials tend to have greater changes to the lens parameters compared to lower water content material lenses.


Asunto(s)
Lentes de Contacto Hidrofílicos , Equipos Desechables , Temperatura , Humanos , Tomografía de Coherencia Óptica
14.
Biosens Bioelectron ; 257: 116284, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38657379

RESUMEN

Smart contact lenses (SCLs) have been considered as novel wearable devices for out-of-hospital and self-monitoring applications. They are capable of non-invasively and continuously monitoring physiological signals in the eyes, including vital biophysical (e.g., intraocular of pressure, temperature, and electrophysiological signal) and biochemical signals (e.g., pH, glucose, protein, nitrite, lactic acid, and ions). Recent progress mainly focuses on the rational design of wearable SCLs for physiological signal monitoring, while also facilitating the treatment of various ocular diseases. It covers contact lens materials, fabrication technologies, and integration methods. We also highlight and discuss a critical comparison of SCLs with electrical, microfluidic, and optical signal outputs in health monitoring. Their advantages and disadvantages could help researchers to make decisions when developing SCLs with desired properties for physiological signal monitoring. These unique capabilities make SCLs promising diagnostic and therapeutic tools. Despite the extensive research in SCLs, new technologies are still in their early stages of development and there are a few challenges to be addressed before these SCLs technologies can be successfully commercialized particularly in the form of rigorous clinical trials.


Asunto(s)
Técnicas Biosensibles , Lentes de Contacto , Dispositivos Electrónicos Vestibles , Humanos , Técnicas Biosensibles/instrumentación , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Diseño de Equipo
15.
J. optom. (Internet) ; 17(1)Jan.-March. 2024. tab, graf
Artículo en Inglés | IBECS | ID: ibc-229115

RESUMEN

Objective This study analyses strategies and attitudes on myopia management reported by eye care practitioners (ECP) from Spain in 2022. Methods A questionnaire was distributed to ECPs worldwide via the internet through professional associations. The questionnaire was distributed by email to all registered Spanish optician-optometrists. Questions examined awareness of increasing myopia prevalence; perceived efficacy; uptake of available approaches; and reasons preventing further uptake of specific approaches. Results Of 3,107 practitioners who participated in the study, 380 were Spanish ECPs. Using a 10-point scale, Spanish practitioners reported less concern about increasing pediatric myopia (8.3 ± 1.6) compared to ECP's worldwide (8.5 ± 1.9) (p < 0.001), but similar level of clinical activity in myopia control (7.8 ± 2.3 vs. 7.5 ± 2.5, respectively) (p > 0.05); however, around half of all prescribed treatments were single-vision distance spectacles/contact lenses both in Spain and in most regions, with Spanish practitioners prescribing less single-vision spectacles than African and Asian (p < 0.001), but more than Australasian practitioners (p = 0.04). No significant differences were found between Spain and the other regions in the perceived efficacy of combined therapy, orthokeratology, and outdoor time (p > 0.05), with the former being perceived as the most effective myopia control method followed by orthokeratology. No significant differences were found between Spain and the world's average in factors preventing the prescription of myopia control approaches (p > 0.05). Spanish practitioners reported that embracing myopia management has a positive, but lower impact on customer loyalty, practice revenue and job satisfaction compared with the other regions (all p < 0.001). Conclusions Myopia control is increasing, although around half of practitioners still prescribe single-vision distance spectacles/contact lenses to. ... . (AU)


Asunto(s)
Humanos , Miopía/prevención & control , Miopía/terapia , Lentes de Contacto , Anteojos , España
16.
Clin Proteomics ; 21(1): 23, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38481131

RESUMEN

BACKGROUND: Human tear protein biomarkers are useful for detecting ocular and systemic diseases. Unfortunately, existing tear film sampling methods (Schirmer strip; SS and microcapillary tube; MCT) have significant drawbacks, such as pain, risk of injury, sampling difficulty, and proteomic disparities between methods. Here, we present an alternative tear protein sampling method using soft contact lenses (SCLs). RESULTS: We optimized the SCL protein sampling in vitro and performed in vivo studies in 6 subjects. Using Etafilcon A SCLs and 4M guanidine-HCl for protein removal, we sampled an average of 60 ± 31 µg of protein per eye. We also performed objective and subjective assessments of all sampling methods. Signs of irritation post-sampling were observed with SS but not with MCT and SCLs. Proteomic analysis by mass spectrometry (MS) revealed that all sampling methods resulted in the detection of abundant tear proteins. However, smaller subsets of unique and shared proteins were identified, particularly for SS and MCT. Additionally, there was no significant intrasubject variation between MCT and SCL sampling. CONCLUSIONS: These experiments demonstrate that SCLs are an accessible tear-sampling method with the potential to surpass current methods in sampling basal tears.

17.
Int J Mol Sci ; 25(5)2024 Feb 24.
Artículo en Inglés | MEDLINE | ID: mdl-38473902

RESUMEN

The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.


Asunto(s)
Biopelículas , Lentes de Contacto Hidrofílicos , Humanos , Bacterias , Antibacterianos , Hidrogeles , Lentes de Contacto Hidrofílicos/microbiología , Pseudomonas aeruginosa/fisiología
18.
Cont Lens Anterior Eye ; 47(2): 102130, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38443210

RESUMEN

INTRODUCTION: Artificial Intelligence (AI) chatbots are able to explain complex concepts using plain language. The aim of this study was to assess the accuracy of three AI chatbots answering common questions related to contact lens (CL) wear. METHODS: Three open access AI chatbots were compared: Perplexity, Open Assistant and ChatGPT 3.5. Ten general CL questions were asked to all AI chatbots on the same day in two different countries, with the questions asked in Spanish from Spain and in English from the U.K. Two independent optometrists with experience working in each country assessed the accuracy of the answers provided. Also, the AI chatbots' responses were assessed if their outputs showed any bias towards (or against) any eye care professional (ECP). RESULTS: The answers obtained by the same AI chatbots were different in Spain and the U.K. Also, statistically significant differences were found between the AI chatbots for accuracy. In the U.K., ChatGPT 3.5 was the most and Open Assistant least accurate (p < 0.01). In Spain, Perplexity and ChatGPT were statistically more accurate than Open Assistant (p < 0.01). All the AI chatbots presented bias, except ChatGPT 3.5 in Spain. CONCLUSIONS: AI chatbots do not always consider local CL legislation, and their accuracy seems to be dependent on the language used to interact with them. Hence, at this time, although some AI chatbots might be a good source of information for general CL related questions, they cannot replace an ECP.


Asunto(s)
Lentes de Contacto , Optometristas , Humanos , Inteligencia Artificial , Lenguaje , Fuentes de Información
19.
Vision (Basel) ; 8(1)2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38535760

RESUMEN

This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1-2 h of CL wear) and three in the afternoon (after 7-9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.

20.
Ther Adv Ophthalmol ; 16: 25158414241232258, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38516169

RESUMEN

Background: New developments in artificial intelligence, particularly with promising results in early detection and management of keratoconus, have favorably altered the natural history of the disease over the last few decades. Features of artificial intelligence in different machine such as anterior segment optical coherence tomography, and femtosecond laser technique have improved safety, precision, effectiveness, and predictability of treatment modalities of keratoconus (from contact lenses to keratoplasty techniques). These options ingrained in artificial intelligence are already underway and allow ophthalmologist to approach disease in the most non-invasive way. Objectives: This study comprehensively describes all of the treatment modalities of keratoconus considering machine learning strategies. Design: A multidimensional comprehensive systematic narrative review. Data sources and methods: A comprehensive search was done in the five main electronic databases (PubMed, Scopus, Web of Science, Embase, and Cochrane), without language and time or type of study restrictions. Afterward, eligible articles were selected by screening the titles and abstracts based on main mesh keywords. For potentially eligible articles, the full text was also reviewed. Results: Artificial intelligence demonstrates promise in keratoconus diagnosis and clinical management, spanning early detection (especially in subclinical cases), preoperative screening, postoperative ectasia prediction after keratorefractive surgery, and guiding surgical decisions. The majority of studies employed a solitary machine learning algorithm, whereas minor studies assessed multiple algorithms that evaluated the association of various keratoconus staging and management strategies. Last but not least, AI has proven effective in guiding the implantation of intracorneal ring segments in keratoconus corneas and predicting surgical outcomes. Conclusion: The efficient and widespread clinical translation of machine learning models in keratoconus management is a crucial goal of potential future approaches to better visual performance in keratoconus patients. Trial registration: The article has been registered through PROSPERO, an international database of prospectively registered systematic reviews, with the ID: CRD42022319338.


Keratoconus: from fundamentals to future Artificial intelligence has changed how we treat the eye disease keratoconus in recent years. This study examines the many keratoconus therapies available, including surgery and contact lens wear, and how artificial intelligence can improve the safety and accuracy of these procedures. We combed through numerous papers to locate this data. To achieve the best outcomes, several parameters and methods should be evaluated. According to the study, some elements from eye scans are more useful than others. The idea behind using artificial intelligence is to help patients see better and treat keratoconus more effectively.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...