Arq. bras. oftalmol ; Arq. bras. oftalmol;79(5): 312-314, Sept.-Oct. 2016. graf
Artículo en Inglés | LILACS | ID: biblio-827974

RESUMEN

ABSTRACT Purpose: To compare central corneal thickness (CCT) measurements of healthy individuals obtained with ultrasonic pachymetry (UP) and non-contact specular microscopy (NCSM). Method: In total, 148 eyes of 74 subjects with no ocular or systemic diseases were included in the study. Central corneal thickness measurements of all patients performed with UP and NCCM were compared. Results: A total of 74 subjects (38 females) were included in this study. The mean age was 45.2 ± 18.4 (range 12-85) years. The mean central corneal thickness of all 148 eyes was 546.9 ± 40 μm with UP and 510.8 ± 42 μm with NCSM. The mean central corneal thickness measured with NCSM was 35 μm thinner than that measured with UP (p<0.001). A high degree of agreement was found between the two methods (r=0.942, p<0.001). Conclusions: Our results suggest that NCSM measures thinner corneas than UP and that the correction formula we identified should be applied when comparing between these two devices.


RESUMO Objetivo: Comparar as medidas de espessura central corneana (CCT) de indivíduos saudáveis obtidos pela paquimetria ultrassônica (UP) e microscopia especular sem contato (NCSM). Método: Cento e quarenta e oito olhos de 74 indivíduos que não tinham doenças oculares ou sistêmicas foram incluídos no estudo. Medidas da espessura central corneana de todos os pacientes foram comparadas entre UP (SP 100, Tomey, Nagoya, Japão) e do NCSM (NSP-9900, Konan Medical, Inc., Hyogo, Japão). Resultados: Um total de 74 indivíduos (38 mulheres) foram incluídos neste estudo. A idade média foi de 45,2 ± 18,4 (variação 12-85) anos. A medida média da espessura central corneana de todos os 148 olhos foi 546,9 ± 40 μm com UP e 510,8 ± 42 μm com NCSM. A espessura central corneana média avaliada pelo NCSM foi de 35 μm mais fina do que a UP (p<0,001). Foi encontrado um elevado grau de concordância entre os dois métodos (r=0,942, p<0,001). Conclusões: Nossos resultados sugerem que a microscopia especular sem contato mede córneas mais finas em comparação com a UP e que o fator de correção identificado deve ser aplicado ao fazer comparações entre esses dois aparelhos.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Ultrasonografía/instrumentación , Córnea/anatomía & histología , Paquimetría Corneal/instrumentación , Microscopía/instrumentación , Valores de Referencia , Modelos Lineales , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Estadísticas no Paramétricas , Paquimetría Corneal/métodos , Microscopía/métodos
2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(3): 177-179, tab
Artículo en Inglés | LILACS | ID: lil-787329

RESUMEN

ABSTRACT Purpose: To evaluate anterior segment parameters in patients with pseudoexfoliation syndrome (PXS) using Scheimpflug imaging. Methods: Forty-three PXS patients and 43 healthy control subjects were included in this cross-sectional study. All participants underwent a detailed ophthalmologic examination. Anterior segment parameters were measured using a Scheimpflug system. Results: Considering the PXS and control groups, the mean corneal thicknesses at the apex point (536 ± 31 and 560 ± 31 µm, respectively, p=0.001), at the center of the pupil (534 ± 31 and 558 ± 33 µm, respectively, p=0.001), and at the thinnest point (528 ± 30 and 546 ± 27 µm, respectively, p=0.005) were significantly thinner in PXS patients. Visual acuity was significantly lower (0.52 ± 0.37 versus 0.88 ± 0.23, p<0.001) and axial length was significantly longer (23.9 ± 0.70 mm versus 23.2 ± 0.90 mm, p=0.001) in the PXS eyes than in the control eyes. There were no statistically significant differences in the mean values of keratometry, anterior chamber angle, anterior chamber depth, corneal volume, and anterior chamber volume between the PXS and control eyes. Conclusions: The patients with PXS had thinner corneas, worse visual acuity, and longer axial length compared with those in the healthy controls.


RESUMO Objetivo: Avaliar os parâmetros do segmento anterior em pacientes com síndrome de pseudoexfoliação (PXS) utilizando imagens de Scheimpflug. Métodos: Quarenta e três pacientes com PXS e 43 indivíduos saudáveis foram incluídos neste estudo transversal. Todos os participantes foram submetidos ao exame oftalmológico detalhado. Parâmetros do segmento anterior foram medidos por sistema de Scheimpflug. Resultados: Considerando os grupos PXS e controle, respectivamente, as espessuras médias da espessura corneana no ápice (536 ± 31 µm e 560 ± 31 µm, p=0,001), no centro da pupila (534 ± 31 µm e 558 ± 33 µm, p=0,001), e no ponto mais fino (528 ± 30 µm e 546 ± 27 µm, p=0,005), foram significativamente mais finas em pacientes com PXS. A acuidade visual foi significativamente menor (0,52 ± 0,37 contra 0,88 ± 0,23, p<0,001) e comprimento axial foi significativamente maior (23,9 ± 0,70 milímetros contra 23,2 ± 0,90 milímetros, p=0,001) em olhos com PXS comparados com os olhos controle. Não houve diferenças estatisticamente significativas entre PXS e controle olhos em valores médios de ceratometria, ângulo da câmara anterior, profundidade da câmara anterior, volume da córnea e volume de câmara anterior. Conclusões: Os pacientes com PXS tem córneas mais finas, pior acuidade visual, e maior comprimento axial em comparação com controles saudáveis.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Síndrome de Exfoliación/patología , Segmento Anterior del Ojo/patología , Tamaño de los Órganos , Valores de Referencia , Diagnóstico por Imagen/métodos , Agudeza Visual , Estudios de Casos y Controles , Glaucoma/patología , Estudios Transversales , Síndrome de Exfoliación/diagnóstico por imagen , Estadísticas no Paramétricas , Técnicas de Diagnóstico Oftalmológico , Longitud Axial del Ojo/patología , Presión Intraocular , Segmento Anterior del Ojo/diagnóstico por imagen
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(2): 92-95, Mar.-Apr. 2016. tab
Artículo en Inglés | LILACS | ID: lil-782813

RESUMEN

ABSTRACT Purpose: To analyze intraocular pressure (IOP) and central corneal thickness (CCT) in newborns during the first 12 h of life. Methods: Forty-three newborns born by vaginal delivery (VD) and 30 newborns born by cesarean section (CS) were evaluated. IOP and CCT were measured using Tono-Pen and handheld pachymeter, respectively, at both the 5th minute after delivery and at the 12th h of life. Results: The mean IOP for the VD group was significantly higher than that of the CS group at both the 5th minute and 12th h (p =0.042 and p =0.018, respectively). In both groups, the IOP decreased by the 12th h, but the decrease was only significant for the CS group (p =0.020). The decrease in CCT over the 12 h was significant for both groups (p <0.001). In the VD and CS groups, the IOP values of the males were significantly higher than those of the females at the fifth minute only (p =0.024 and p =0.043, respectively). No other values were significantly different between the genders. Conclusions: Newborn IOP is affected by the mode of delivery and gender. A higher IOP was found in vaginally delivered newborns than in CS newborns for at least 12 h postpartum. CCT showed a significant decline within 12 h. Male newborns have significantly higher IOP values in the first minutes of life.


RESUMO Objetivos: Analisar a pressão intraocular (IOP) e a espessura corneana central (CCT) em recém-nascidos durante as primeiras 12 horas de vida. Método: Quarenta e três recém-nascidos nascidos por parto vaginal (VD) e 30 recém-nascidos nascidos após cesariana (CS) foram avaliados. IOP e CCT foram medidos com Tono-Pen e Handheld Pachymeter no quinto minuto após o parto e na décima segunda hora de vida. Resultados: A média de IOP para o grupo VD foi significativamente maior do que o grupo CS tanto no quinto minuto quanto na décima segunda hora (p=0,042, p=0,018, respectivamente). Em ambos os grupos, a IOP diminuiu na décima segunda hora, mas a redução foi significativa apenas para o grupo CS (p=0,020). A diminuição da CCT nas doze horas foi significativa para ambos os grupos (p<0,001). Nos grupos VD e CS os valores de IOP dos homens foram significativamente maiores do que das mulheres apenas no quinto minuto (p=0,024 e p=0,043, respectivamente). Outros valores não foram significativamente diferentes entre os sexos. Conclusões: A IOP em recém-nascidos é afetada pela via de parto e pelo sexo. A IOP é maior em recém-nascidos de parto normal durante pelo menos 12 horas. A CCT mostra queda significativa no prazo de 12 horas. Recém-nascidos do sexo masculino têm valores de IOP significativamente mais elevados nos primeiros minutos de vida.


Asunto(s)
Humanos , Masculino , Femenino , Embarazo , Recién Nacido , Cesárea/efectos adversos , Factores Sexuales , Córnea/anatomía & histología , Parto Obstétrico/efectos adversos , Presión Intraocular/fisiología , Factores de Tiempo , Tonometría Ocular/métodos , Cesárea/métodos , Estudios Prospectivos , Parto Obstétrico/métodos
4.
Rev. bras. oftalmol ; 74(6): 382-385, nov.-dez. 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-767083

RESUMEN

RESUMO Objetivo: Avaliar a capacidade de dados de perfil paquimétrico horizontal, a fim de distinguir o ceratocone de córneas normais, e comparar a precisão de índices com outros tomográficos mais complexos. Métodos: Em um estudo retrospectivo, um olho selecionado aleatoriamente de 225 pacientes com ceratocone bilateral e de 335 pacientes com córneas normais foram incluídos. Todos os pacientes foram examinados por um especialista em córnea e foram submetidos ao exame de tomografia de córnea, Pentacam HR (Oculus, Wetzlar, Alemanha). Os dados de perfil paquimétrico horizontal em 6 milímetros passando pelo ápice foi avaliado. Com esses dados, a espessura no ápice corneano (P.ápice), a espessura no ponto mais fino do perfil horizontal (P.min.H), a progressão paquimétrica do ponto mais fino para o mais espesso (PPmin-máx), a progressão paquimétrica média no meridiano temos como referencial a média normal (PPméd) e a adequação a uma linha de tendência polinomial do segundo grau (R2). Um modelo de inteligência artificial foi construído para combinar esses dados. O desempenho para distinguir ceratocone do normal foi avaliada por curvas ROC. Resultados: Todos os índices avaliados foram estatisticamente diferentes entre os dois grupos (p <0,001). A área sob a curva ROC (AUC) de paquimetria no ápice e no TP foram de 0,904 e 0,938, respectivamente. O índice tomográfico com maior AUC foi o BAD-D (0,997). Em relação ao perfil horizontal, a AUC do P.min.H e PPmin-max foram 0,915 e 0,927, respectivamente. A adequação à linha de tendência para o gráfico de espessura no ápice apresentou AUC 0,896. O melhor desempenho foi obtido com o PPméd (AUC 0,932 Sensibilidade = 84,4% e especificidade de 92,5%). O modelo de inteligência artificial combinando todos os itens derivados do perfil horizontal melhorou o desempenho (AUC 0,991 Sens. = 96% e espec. = 98%). Conclusão: O perfil de espessura horizontal permite detectar o ceratocone, com capacidade comparável aos índices mais complexos. Esse tipo de análise pode fornecer o básico para novas abordagens, que utilizem dados presentes em aparelhos mais simples que o tomógrafo, reduzindo o custo para os pacientes.


ABSTRACT Purpose: To evaluate the ability of horizontal thickness profile to distinguish keratoconus from normal corneas, and compare the accuracy of these indices with more complex tomographic indices. Methods: In a retrospective study, one eye randomly selected from 225 patients with bilateral keratoconus and 335 patients with normal corneas were included. All patients were examined by a corneal specialist and underwent the examination of corneal tomography, Pentacam HR (Oculus, Wetzlar, Germany). Data of horizontal pachymetric profile passing through the apex of 6 mm was evaluated. With these data, the thickness at the corneal apex (P.ápice), the thickness of the thinnest point of the horizontal profile (P.min.H), the pachymetric progression from the thinnest point to the thickest (PPmin-max), the average pachymetric progression in the meridian as reference the average from the normal population (PPméd) and the fitness with a second degree polynomial trendline (R2). An artificial intelligence model was built to combine this data. The performance for distinguishing normal keratoconus was evaluated by ROC curves. Results: All of these indices were statistically different between the two groups (p <0.001). The area under the ROC curve (AUC) thickness at the apex and TP were 0.904 and 0.938, respectively. The tomographic index with higher AUC was BAD-D (0.997). Regarding the horizontal profile, the AUC of PP.min.H and PPmin-max were 0.915 and 0.927, respectively. The fitness to the trendline to the horizontal thickness graph AUC was 0.896. The best performance was obtained with the PPméd (AUC 0.932 sensitivity = 84.4% and specificity of 92.5%). The artificial intelligence model combining all items derived from horizontal profile improved performance (AUC 0.991 Sensitivity = 96% and specificity of 98%). Conclusion: The horizontal thickness profile can detect keratoconus, with a capacity comparable to more complex indices. This type of analysis can provide the basics for new approaches, using data present in simpler devices than the tomographer reducing the cost for the patients.


Asunto(s)
Humanos , Adulto , Tomografía/métodos , Topografía de la Córnea/métodos , Paquimetría Corneal/métodos , Queratocono/diagnóstico , Tomografía/instrumentación , Estudios Retrospectivos , Córnea/anatomía & histología , Córnea/diagnóstico por imagen , Topografía de la Córnea/instrumentación , Paquimetría Corneal/instrumentación
5.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(6): 345-350, Nov-Dec/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-735807

RESUMEN

Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusion: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values. .


Objetivo: Comparar os resultados de medições de espessura corneana central (CCT ) obtidos com reflectometria óptica de baixa coerência (OLCR), tomografia de coerência óptica de domínio Fourier (FD-OCT ), e uma câmera Scheimpflug (SC), combinada com topografia corneana de placido. Métodos: Um olho de cada de 25 indivíduos saudáveis foram incluídos neste estudo. Um exame oftalmológico detalhado foi realizado em todos os casos após as medidas de CCT com OLCR, FD-OCT, e SC. Os resultados foram comparados por meio do teste ANOVA. Análise de Bland-Altman foi utilizada para demonstrar concordância entre os métodos. A repetibilidade intra-examinador foi avaliada por meio de coeficientes de correlação intraclasse (ICCs). Resultados: Foram observadas diferenças estatisticamente significativas entre os resultados das medidas de CCT obtidas a partir de três dispositivos diferentes (p=0,009). Foram encontradas correlações significativas entre OLCR e FD-OCT (r=0,97, p<0,0001), FD-OCT e SC (r=0,91, p<0,0001), e OLCR e SC (r=0,95; p<0,0001). Os limites de 95% de confiança (LOA) obtidos a partir de gráficos de Bland-Altman foram de -7,2 a 28,7 μm para OLCR contra FD-OCT, de -19,2 a 30,4 μm para OLCR contra SC, e de -42,6 a 32,3 μm para FD-OCT contra SC. A repetibilidade intra-examinador foi excelente para cada método com ICCs>0,98. Conclusões: Apesar de os resultados das medições CCT obtidos a partir destes três dispositivos terem sido altamente correlacionados entre si e as diferenças médias entre os instrumentos serem comparáveis à flutuação relatado da CCT diurna, as medições não são diretamente intercambiáveis na prática clínica em razão da largura dos valores limites de confiança. .


Asunto(s)
Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Córnea/anatomía & histología , Paquimetría Corneal/instrumentación , Paquimetría Corneal/métodos , Topografía de la Córnea/métodos , Tomografía de Coherencia Óptica/métodos , Análisis de Varianza , Anatomía Transversal , Biometría/instrumentación , Biometría/métodos , Topografía de la Córnea/instrumentación , Análisis de Fourier , Variaciones Dependientes del Observador , Fotograbar/instrumentación , Valores de Referencia , Reproducibilidad de los Resultados , Estadísticas no Paramétricas
6.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(4): 225-227, Jul-Aug/2014. tab
Artículo en Inglés | LILACS | ID: lil-728669

RESUMEN

Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n=138), while those without ROP were allocated to Group 2 (n=236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p<0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p>0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length. .


Objetivo: Determinar o diâmetro horizontal corneano, a espessura corneana central e o comprimento axial de prematuros. Métodos: Crianças com peso de nascimento menor que 2.500 g ou idade gestacional menor que 36 semanas foram incluídas no estudo. Recém-nascidos com retinopatia da prematuridade (ROP) foram alocados no Grupo 1 (n=138), sem ROP foram alocados no Grupo 2 (n=236). Todos os bebês foram submetidos a exame oftalmológico completo, incluindo medida do diâmetro corneano, paquimetria, biometria e fundoscopia. O diâmetro horizontal corneano, a espessura corneana central e o comprimento axial dos grupos foram comparados. Teste de "Student" para amostras independentes foi utilizado na análise estatística. Resultados: Os dados foram obtidos a partir de 374 olhos de 187 crianças (102 meninas, 85 meninos). A idade gestacional média ao nascer foi de 30,7 ± 2,7 semanas (variação de 25 a 36 semanas). O peso médio ao nascer foi de 1.514 ± 533,3 g (variação de 750 a 1.970 g). A idade pós-menstrual média de exame foi de 40,0 ± 4,8 semanas. A idade gestacional e o peso médio do Grupo 1 eram estatisticamente inferiores aos do Grupo 2 (p<0,05). Não houve diferenças significativas no diâmetro horizontal da córnea, espessura corneana central e medidas de comprimento axial entre dois grupos (p>0,05). Conclusões: A presença de ROP em prematuros não altera o diâmetro da córnea horizontal, espessura corneana central e o comprimento axial. .


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Córnea/anatomía & histología , Recien Nacido Prematuro , Peso al Nacer , Estudios de Casos y Controles , Edad Gestacional , Retinopatía de la Prematuridad/patología
7.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(3): 152-154, May-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-723839

RESUMEN

Purpose: To investigate the distribution of axial length, anterior chamber depth, lens thickness, vitreous chamber depth, and central corneal thickness in children at different age groups. Methods: We studied 364 eyes in 182 children with ages between 1 and 12 years. Axial length, anterior chamber depth, lens thickness, and vitreous chamber depth were measured by ultrasound biometry. Central corneal thickness was measured by ultrasound pachymetry in all children. Results: The mean age was 6.54 ± 3.42 years. The axial length was 20.95 mm in 1-2 years old and 22.95 mm in 11-12 years old. The central corneal thickness was 556 µm in 1-2 years old and 555 µm in 11-12 years old. The mean anterior chamber depth and vitreous chamber depth increased with age (3.06 mm to 3.44 mm in anterior chamber depth, 13.75 mm to 15.99 mm in vitreous chamber depth), and the lens thickness decreased as age increased (3.67-3.51 mm). Conclusion: The axial length increased with age and reached adult levels by the age of 9-10 years. The lens thickness gradually decreased until 12 years. The central corneal thickness measurements did not yield a linear algorithm. .


Objetivo: Investigar a distribuição do comprimento axial, profundidade da câmara anterior, espessura do cristalino, profundidade da câmara vítrea e espessura corneal central em crianças em diferentes faixas etárias. Métodos: Foram estudados 364 olhos de 182 crianças entre 1 e 12 anos de idade. O comprimento axial, a profundidade da câmara anterior , a espessura do cristalino e a profundidade da câmara vítrea foram medidos por biometria ultrassônica. A espessura corneal central foi medida por paquimetria ultrassônica em todas as crianças. Resultados: A idade média foi de 6,54 ± 3,42 anos. O comprimento axial foi 20,95 mm no grupo de 1-2 anos de idade e 22,95 mm no grupo de 11-12 anos de idade. A espessura corneal central foi 556 µm no grupo de 1-2 anos de idade e 555 µm no grupo de 11-12 anos de idade. A profundidade da câmara anterior média e profundidade da câmara vítrea aumentou com a idade (3,06 mm a 3,44 mm de profundidade da câmara anterior, 13,75 mm a 15,99 mm de profundidade da câmara vítrea) e da espessura do cristalino diminuiu com o aumento da idade (3,67 mm a 3,51 mm). Conclusões: Em nosso estudo, os valores do comprimento axial aumentou com a idade e atingiu os níveis adultos aos 9-10 anos de idade. A espessura do cristalino diminuiu gradualmente até os 12 anos de idade. As medições de espessura corneal central não seguiu um algoritmo linear. .


Asunto(s)
Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Biometría/métodos , Ojo/anatomía & histología , Factores de Edad , Análisis de Varianza , Córnea/anatomía & histología , Córnea , Ojo , Tamaño de los Órganos , Valores de Referencia , Estudios Retrospectivos , Factores Sexuales
8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(1): 17-20, Jan-Feb/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-715556

RESUMEN

Purpose: To assess the agreement between the elevation and curvature measurements of the anterior and posterior corneal surfaces obtained using the Galilei Dual Scheimpflug Analyzer and those obtained using the Pentacam single Scheimpflug system. Methods: This prospective, noninterventional, diagnostic study was conducted at the Department of Ophthalmology at the American University of Beirut (Medical Center) and included 60 eyes of 60 consecutive patients. Measurements were obtained using 2 different Scheimpflug analyzers (Galilei and Pentacam). The best-fit sphere was set at 8 mm in both machines. Pachymetry (CCT), anterior elevation (AE) and posterior elevation (PE), and curvature were assessed. Pearson's correlation coefficients, comparison of means, and Bland-Altman plots were used to evaluate agreement between the 2 systems. Results: The average CCT (at the corneal apex) was 533 ± 35 µm and 532 ± 37 µm (p=0.980), the average central AE was 1.25 ± 3.95 µm and 2.29 ± 5.28 µm (p=0.964), and the average central PE was 4.19 ± 8.18 µm and 5.42 ± 14.05 (p=0.956) µm with the Galilei and Pentacam, respectively. Conclusion: The Scheimpflug analyzers correlated well in the assessment of pachymetry, elevation, and curvature. .


Objetivo: Avaliar a concordância entre as medidas de elevação e curvatura das superfícies anterior e posterior da córnea obtidos pelos analisadores de Scheimpflug Galilei e Pentacam. Método: Estudo de teste diagnóstico, prospectivo, não-intervencional realizado no Departamento de Oftalmologia do Centro Médico da Universidade Americana de Beirute. Sessenta olhos de 60 pacientes consecutivos. As medições foram feitas usando dois analisadores Scheimpflug diferentes (Galilei e Pentacam). A esfera de melhor ajuste foi fixada em 8 mm para ambos equipamentos. Paquimetria (CCT), elevação anterior (AE) e elevação posterior (PE), e curvatura foram avaliados. Coeficientes de correlação de Pearson, comparação das médias, e gráficos de Bland-Altman foram utilizados para avaliar a correlação. Resultados: A média de CCT (no ápice da córnea) foi 533 ± 35 µm usando o Galilei e 532 ± 37 µm usando o Pentacam (p=0,980). As médias centrais de AE foram de 1,25 ± 3,95 µm e 2,29 ± e 5,28 µm com o Galilei e Pentacam, respectivamente (p=0,964). As médias de centrais de PE foram 4,19 ± 8,18 µm e 5,42 ± 14,05 µm com a Galilei e Pentacam, respectivamente (p=0,956). Conclusões: Os analisadores de Scheimpflug avaliados correlacionam bem em termos de paquimetria, elevação e curvatura. .


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Topografía de la Córnea , Córnea/anatomía & histología , Técnicas de Diagnóstico Oftalmológico/instrumentación , Fotograbar/instrumentación , Córnea/patología , Estudios Prospectivos