Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 802
Filtrar
1.
Int J Clin Pediatr Dent ; 17(5): 524-527, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-39355184

RESUMEN

Introduction: Stainless steel crowns (SSCs) are the most durable and effective restorations for primary teeth. Titanium-coated SSCs are newer on the market, and this study was conducted to assess the amount of nickel (Ni) and titanium ions released from titanium-coated SSCs, with and without trim, in artificial saliva. Materials and methods: A total of 60 titanium-coated SSCs were divided into two groups-group I (n = 30, without trim) and group II (n = 30, with trim) and were immersed in 5 mL artificial saliva. The amount of Ni and titanium released in each group was measured by inductively coupled plasma-mass spectrometry on days 1, 7, and 21. Results: The amount of Ni ion released in group I on day 1 was 0.0096 ppm and reduced on day 7 (0.0091 ppm) and day 21 (0.0088 ppm). Whereas the amount of Ni ion released in group II was the same for all 3 days (0.0096 ppm). The amount of titanium ion released in both groups was the same on all 3 days (0.00108 ppm). Conclusion: There was no significant difference seen in the mean Ni and titanium ion release between the two groups on all 3 days. The cumulative release of metals from titanium-coated SSCs in each of the groups was significantly lower than the level required to produce any harmful effects. Any of the groups of commercially available SSCs can be used in pediatric dentistry. How to cite this article: Biradar R, Siaddaiah SB, Bhat PK. Evaluation of Nickel and Titanium Releasing from Titanium-coated Stainless Steel Crowns Regarding Trimming: An In Vitro Study. Int J Clin Pediatr Dent 2024;17(5):524-527.

2.
BMC Oral Health ; 24(1): 1164, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39354479

RESUMEN

BACKGROUND: Stainless steel crowns (SSCs) are commonly employed to restore the posterior teeth of children and over the years, they are available with improved anatomical shapes. This study was conducted to evaluate and assess the effect of the placement of SSCs on the masticatory efficiency of children. METHODS: This pilot cross-sectional split-mouth study assessed masticatory efficiency in children aged 6-11 years. Fifteen participants, each with stainless-steel crowns placed unilaterally at least one month prior, were included. This study utilized two flavours of trident chewing gum (red and green) to measure masticatory efficiency. The child was asked to chew half a strip of red and green chewing gum placed one on top of the other using either the noncrown or crown side 15 times. Another set of chewing gum was given to the child to chew 20 times on the same side. The chewing exercise was repeated using teeth on the other side. Chewed gum samples were collected, photographed, and analysed via ImageJ software to determine the red and green areas. Masticatory efficiency was subsequently calculated with the help of a formula in which the red areas and green areas were calculated via ImageJ software. The data were analysed with paired t tests via SPSS (version 20.0). RESULTS: When the mean values of the crown side were compared with those of the noncrown side following 15 chewing cycles, the chewing efficiency on the noncrown side was greater, with a difference of 0.303, whereas the chewing efficiency following 20 chewing cycles was greater on the crown side, with a difference of 0.814. However, both differences were statistically nonsignificant, with t values of -0.07 and 0.26, respectively, and p values of 0.94 and 0.8, respectively. CONCLUSION: The presence of SSCs on the molars of children did not affect masticatory efficiency.


Asunto(s)
Coronas , Masticación , Acero Inoxidable , Humanos , Masticación/fisiología , Estudios Transversales , Niño , Proyectos Piloto , Acero Inoxidable/química , Masculino , Femenino , Goma de Mascar
3.
Artículo en Inglés | MEDLINE | ID: mdl-39365545

RESUMEN

PURPOSE: To assess the knowledge, practice, and concerns about the Hall Technique among pediatric dentists (PDs) and general dental practitioners (GDPs) working in primary care settings in the State of Qatar. METHODS: A prospective questionnaire-based survey was distributed to all GDPs and PDs working at different Primary Health Care Corporation centers in Qatar between 1 November and 10 December 2023. Descriptive data analysis was carried out. RESULTS: The response rate was 49% among GPDs and 100% among PDs. Approximately 85% of PDs and 48% of GDPs were familiar with the HT although only 58% of the PDs and 4% of the GDPs applied HT preformed metal crowns (HTPMCs) in their current primary care practice. Majority of both PDs and GDPs did not consider HTPMCs as the treatment of choice for restoring asymptomatic carious primary molars and preferred applying the HT for cavitated carious lesions over non-cavitated lesions. Regarding HT practices, 57.7% of PDs and 48% of GDPs always planned on taking a pre-operative radiograph before the procedure, while only 15.4% of PDs and 8% of GDPs would always consider using an orthodontic separator prior to placing an HTPMC. The main concerns among the respondents about the HT included sealing in caries (PDs 31%; GDPs 50%), high occlusion (PDs 57.7%; GDPs 53.3%), and gingival damage (27% PDs; 47% GDPs.) Endorsement by professional bodies and further research evidence were seen as ways to promote wider adoption of the HT. CONCLUSION: The HT is recognised but not widely used among primary care dentists working in the State of Qatar. HTPMCs are often seen as secondary options for restoring carious primary molars with dentists still having a number of concerns regarding the HT.

4.
Int J Clin Pediatr Dent ; 17(6): 673-682, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39391144

RESUMEN

Aim and background: The Hall technique preformed metal crowns (HT-PMCs) are allegedly oversized, temporarily altering inter-arch relationships. Intra-arch dimensions and leeway space (LWS) HT effects are unknown. Aim: To study single HT-PMC intra-arch effects and treated tooth dimensional changes. Materials and methods: Split-mouth, quasi-experimental, non-randomized feasibility pilot study. Intraoral scans (iTero II®) were taken preorthodontic separator placement (scan1), immediately post single HT-PMCs (scan2) in 13 children, and 1 month later (scan3) in eight children. Control and study quadrants' lengths ("arcs") and HT-PMCs/control tooth dimensions [mesiodistal (MD), buccopalatal/lingual (BP/L), diagonal (Diag1/Diag2)] were recorded in mm (OrthoCAD® software). Paired t-test, repeated analysis of variance (ANOVA) post hoc analysis statistics (p < 0.05). Results: Compared to scan1, the mean study arc increased by 0.7 mm (±0.5) (n = 13, t-test, p < 0.001) at scan2, while at scan3, it increased by 0.8 mm (±0.34) (n = 8, repeated ANOVA, p = 0.008). The HT-PMCs-treated tooth mean dimensions increased at scan2 by 0.9 mm (MD), 0.8 mm (BP/L), 0.5 mm (Diag1), and 0.7 mm (Diag2) (t-test, p < 0.001) with similar observations at scan3. There were no significant changes in the control arc or the control tooth measurements. Conclusion: One single HT-PMC increased the intra-arch quadrant length by approximately up to <1 mm. The HT-PMC-treated tooth was marginally oversized. This pilot study paves the way for a more robust study with a larger sample size. How to cite this article: AlRamzi B, AlHalabi M, Kowash M, et al. Do Hall Technique Crowns Affect Intra-arch Dimensions? A Split-mouth Quasi-experimental Non-randomized Feasibility Pilot Study. Int J Clin Pediatr Dent 2024;17(6):673-682.

5.
J Pharm Bioallied Sci ; 16(Suppl 3): S2479-S2481, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39346257

RESUMEN

Background: Achieving optimal marginal fit is essential for the success of Virgilite Based Lithium Disilicate Ceramic crowns. Materials and Methods: In this in-vitro study, we compared the marginal fit of Virgilite Based Lithium Disilicate Ceramic crowns using two different CAD/CAM scanners, powder free (System A, Omnicam) and powder based (System B, Blue cam). Results: The mean marginal gap for System A was found to be 63.5 µm (standard deviation ± 10.2 µm), while for System B, it was 57.8 µm (standard deviation ± 9.8 µm). System B demonstrated a slightly superior marginal fit compared to System A, with a difference of 5.7 µm. Conclusion: Within the limitations of this study, it can be concluded that both Omnicam and Blue cam produced clinically acceptable marginal fit of Virgilite Based Lithium Disilicate Ceramic crowns. However, Blue cam exhibited a slightly better marginal fit compared to Omnicam. Further clinical studies are warranted to validate these findings.

6.
J Pharm Bioallied Sci ; 16(Suppl 3): S2682-S2684, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39346260

RESUMEN

Background: The selection between Zirconia crowns and metal crowns for anterior teeth restorations is pivotal in prosthodontics due to their distinct properties. However, a comprehensive investigation into their effectiveness in anterior tooth restorations is warranted. Materials and Methods: This in vitro study aimed to compare the effectiveness of Zirconia crowns and metal crowns in anterior teeth restorations. A total of thirty extracted human maxillary central incisors were prepared to receive crowns and randomly allocated into two groups: group A, zirconia crowns; and group B, metal crowns. The crowns were fabricated following standardized protocols and cemented onto the prepared teeth. Various tests, including fracture resistance, marginal adaptation, and color-matching assessment, were conducted on the samples. Results: The mean fracture resistance of Zirconia crowns (Group A) was determined to be 320 N (SD ± 25), whereas it was 280 N (SD ± 30) for metal crowns (Group B). Marginal adaptation assessment revealed a mean gap width of 50 microns (SD ± 10) for Zirconia crowns and 70 microns (SD ± 15) for metal crowns. Evaluation of color matching showed a higher percentage of acceptable matches for Zirconia crowns compared to metal crowns. Conclusion: Zirconia crowns exhibited superior fracture resistance, marginal adaptation, and color matching in comparison to metal crowns for anterior teeth restorations. These findings advocate for Zirconia crowns as a more effective choice for restoring anterior teeth, offering both strength and esthetic appeal.

7.
J Clin Med ; 13(18)2024 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-39336840

RESUMEN

Prosthodontic treatment of developmental age patients presents a significant challenge to the dentist. The growth and development of the stomatognathic system must be considered in treatment planning. Temporary prosthetic restorations must be regularly inspected and recemented, and final prosthetic restoration should not be delivered until the growth of the body is complete. In addition, due to the complex nature of morphological and functional disorders during the developmental period, simultaneous prosthetic and orthodontic treatment may be required. The case presented in this article is a 16-year-old boy with severe tooth destruction caused by untreated caries disease and poor oral hygiene. The patient required conservative, endodontic, and surgical treatment to restore the occlusion and aesthetics to allow the proper development of the masticatory organ. This article also presents the treatment case of a young patient with damaged crowns in the upper arch, which were restored with standard root-crown posts and cores and temporary 3D-printed composite crowns.

8.
Cureus ; 16(8): e66237, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39238743

RESUMEN

Introduction A space between the prepared tooth and the cemented crown can cause microleakage, allowing microorganisms to enter, which in turn leads to the breakdown of the luting cement. To achieve an optimum fit, several factors should be considered, including the type of crown used, the taper of tooth preparation, and the type of cementing agent. Aim The purpose of the current study is to evaluate the microleakage of zirconia crowns cemented with glass ionomer cement (GIC), resin-modified GIC (RMGIC), and self-adhesive resin cement. Materials Forty-five primary mandibular molars were divided into three groups: Group I receiving GIC, Group II receiving RMGIC, and Group III receiving self-adhesive resin cement. These cements were used to lute the teeth with Kedo zirconia crowns. The restored samples underwent thermal cycling and were assessed for microleakage under a stereomicroscope. For the statistical analysis, SPSS version 23.0 was used. Descriptive statistics were presented as frequencies and percentages. Analytical statistics, including the Mann Whitney U test, were used to assess the differences in the level of microleakage between the groups at p < 0.05. Results The Mann Whitney U test revealed no significant difference in the level of microleakage between GIC and RMGIC (p = 0.072). However, self-adhesive resin cement showed significantly less microleakage than GIC (p = 0.000). Similarly, when comparing RMGIC and self-adhesive resin cement, the latter showed significantly less microleakage than the former (p = 0.001). Conclusion Microleakage of Kedo zirconia crowns on mandibular first molars was highest when luted with GIC, followed by RMGIC, and was least when luted with self-adhesive resin cement.

9.
Odontology ; 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39240393

RESUMEN

To evaluate the effect of build direction, post-polymerization time, and aging on the fracture resistance, failure mode, margin quality and Marginal (MD) and Internal Discrepancies (ID), and degree of conversion of tridimensional (3D) printed provisional crowns using the liquid crystal display technique (LCD). A left mandibular first molar was prepared and scanned. After, a full crown was designed (ExoCad) and exported to the LCD-printer software. One hundred and eighty crowns were printed at two build directions (30°, 90°) and post-polymerized for different periods (15, 30, 45 min). Half of the samples were aged (ST) in distilled water (37 °C/90 days). The marginal quality of the crowns was evaluated by the Schriwer method under a stereomicroscope (40x). The replica technique was used to measure the MD and ID and measured under a stereomicroscope (10x), through 20 reference points defined in 5 regions: Occlusal (O), Cusp (CP), Axial (AX), Chamfer (CH), and Finish Line (F). After, the crowns were cemented onto the respective dies using temporary cement and submitted to compression test (ISO150, 1 mm/min, 100 kgf).The failure mode was classified by Burke's fracture mode. The degree of conversion was evaluated through Fourier Transform Infrared Spectroscopy. The data (µm) of MD and ID and fracture resistance (N) were subjected to ANOVA (3 factors) and Tukey's test (5%); Weibull analysis was also performed for fracture resistance data (N). For MD, ID and fracture resistance ANOVA revealed that all factors (P < .001) were significant. For aged groups, the crowns printed at 30° showed lower MD (Tukey). The O_90_30 min (172.13A µm) and O_90_15 min (170.20A µm) groups showed the highest ID values. Higher resistance values were observed for the 30_45 min (844.30A N), 30_30 min (835.35A N), and 90_30 min (820.62A N) groups (Tukey). In the margin analysis, 98.6% of the crowns printed at 30° showed smooth margins without defects. The most prevalent fracture mode (41.7%) was Burke type 5. The degree of conversion (DC) increased with increasing post-polymerization time and aging. Printing provisional crowns at 30° provided lower crown MD and ID, as well as higher fracture resistance. A post-polymerization time of 30 min resulted in higher crown fracture resistance, while aging reduced the resistance of the crowns.

10.
Acta Medica (Hradec Kralove) ; 67(1): 26-31, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39288443

RESUMEN

Recent advancements in digital technologies have transformed clinical workflows in dentistry, ensuring precise restorations. Custom-made crowns and fixed partial dentures (FPDs) now rely on virtual articulation. The digital facebow provides individualized data for CAD settings, streamlining the fabrication via digital workflow. For the purpose of demonstrating the differences observed during fabrication, we present a case report involving a 68-year-old patient seeking a replacement for missing teeth 24, 25, 26, and 27. The treatment plan involved the fabrication of an implant-supported FPD using monolithic zirconia (ZrO2). However, technical hurdles emerged during the planning phase, primarily due to spatial limitations posing a risk of mechanical failure over time. Consequently, we pivoted approach towards a porcelain fused to metal (PFM) FPD. For the PFM FPD, individual values from the digital facebow adjusted both virtual and conventional articulators. For comparison, two ZrO2 FPDs were milled-individual settings and average settings. All restorations underwent assessment for occlusion in maximal intercuspal position and eccentric mandible movements. In conclusion, the case report showed that individualized PFM FPD required minimal adjustments compared to milled ZrO2 restorations, whether using individual or average values. Utilizing individual values from the digital facebow reduced operator working time and minimized the intraoral adjustments.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Prótesis Dental de Soporte Implantado , Humanos , Anciano , Prótesis Dental de Soporte Implantado/métodos , Flujo de Trabajo , Circonio , Dentadura Parcial Fija , Diseño de Prótesis Dental/métodos , Masculino
11.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(5): 652-659, 2024 Oct 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-39304509

RESUMEN

OBJECTIVES: This study aimed to estimate the therapeutic effects of preformed metal crown (PMC) and prefabricated zirconia crowns (ZC) on decayed primary morals in children, as well as to analyze the possible influencing factors. METHODS: A retrospective cohort study was performed on the data of 192 patients (aged 3 to 8) in the Stomatological Department of Shenzhen Children's Hospital from October 2021 to December 2021. The decayed mandibular first molars were selected and restored by vital-pulp therapy followed by PMC and ZC, including 96 cases (96 caries) in the PMC group and 96 cases (96 caries) in the ZC group. Oral clinical examination was performed at 3 months, 1 year, and 2 years after treatment, overwiewing the clinical therapeutic effects and periodontal status of PMC and ZC groups, as well as recording the crown integrity, gingival index (GI), probing bleeding index (BI), plaque index (PLI) and various prosthetic indices. RESULTS: No significance differences existed in the periodontal status of PMC and ZC groups at 3 months, 1 year, and 2 years after treatment (P>0.05). However, the GI, BI, and PLI in the PMC group were higher than those in the ZC group at 3 months, 1 year, and 2 years after treatment, and the difference was dramatically significant (P<0.05). No significances difference existed in various prosthetic indices (P>0.05), as well as in the GI, BI, and PLI, between the two groups (P>0.05). No significant differences existed in various prosthetic indices between genders after PMC restoration (P>0.05). The scores of girls in various prosthetic indices after ZC restoration were higher than those of boys (P<0.05). Pearson correlation analysis indicated an inverse correlation between age in the PMC group and the GI, BI, PLI, and FDI indices (P<0.01), rather than in the ZC group (P>0.05). CONCLUSIONS: PMC and ZC can be applied to restore deciduous molar caries. The periodontal status of deciduous teeth in ZC group was superior to that in the PMC group. The periodontal status of deciduous teeth in PMC group may be stable with increased age.


Asunto(s)
Coronas , Caries Dental , Diente Molar , Diente Primario , Circonio , Humanos , Estudios Retrospectivos , Niño , Preescolar , Femenino , Masculino , Índice Periodontal
12.
Cureus ; 16(8): e66371, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39246859

RESUMEN

Introduction Zirconia is a widely used restorative material in dentistry due to its superior aesthetic and mechanical properties. The oral cavity is a complex ecosystem with various components, which affect the teeth, as well as artificial restorative materials. Various personal and professional interventions carried out can severely affect the properties of restorative materials, thus altering the longevity of the prosthesis; 1.23% acidulated phosphate fluoride (APF) gel is one such professionally applied topical fluoride agent used to prevent caries. The interaction of this APF gel with highly aesthetic restorative material such as zirconia crowns is unknown. Objective The objective of this study is the evaluation of the surface deterioration of prefabricated zirconia crowns on exposure to deionised water and 1.23% acidulated phosphate fluoride (APF) gel with field emission scanning electron microscope (FE-SEM) and mass loss analysis. Material and method Sixty prefabricated paediatric zirconia crowns were taken, 10 samples were immersed in deionised water, 40 samples were immersed in 1.23% APF gel and 10 samples were used as control. Surface morphology and mass loss analysis were carried out at time intervals of four minutes, 24 hours, 48 hours and 72 hours using FE-SEM and digital weighing machine. Results No visual change was observed in the samples immersed in deionised water at the time interval of 72 hours. There was a marked visual change in samples immersed in 1.23% APF gel at the time interval of four minutes to 72 hours; this change involved a loss of gloss to the appearance of chalkiness. FE-SEM analysis for the control group and samples immersed in deionised water showed a smooth, continuous, undisrupted top layer, while samples immersed in 1.23% APF gel showed changes ranging from surface etching, to pinhole porosities, to crack formation and disruption of the surface depending upon the exposure time. Conclusions On the immersion of zirconia crowns in an aqueous acidic medium of 1.23% APF gel, the crowns showed flaws, imperfections and uneven superficial layers. It has been observed that surface grains are disrupted and micropores have been formed. This degraded superficial surface when undergoes cyclic mechanical loading can accelerate the ageing phenomenon of zirconia. Mechanical forces along with a dynamic electrochemical environment can degrade the material properties of zirconia.

13.
J Adv Prosthodont ; 16(4): 255-266, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39221414

RESUMEN

PURPOSE: This study aimed to evaluate the clinical performance of implant-assisted removable partial dentures (IARPD) with surveyed crowns, also known as implant-crown-retained removable partial dentures (ICRPDs). MATERIALS AND METHODS: Electronic searches of MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials, the Web of Science, and the Korea Citation Index were performed according to the established search terms for ICRPD. A literature search was conducted for studies published in English or Korean until September 2023, using the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. RESULTS: A total of 216 journals were searched, and 31 eligible studies were selected based on the inclusion and exclusion criteria. One systematic review included five case reports of ICRPD. Nine retrospective studies evaluated implant survival/success rate, implant failure cases, marginal bone loss, periodontal status, clinical complications, and patient satisfaction. Twenty-one case reports published in Korea showed good prognoses. CONCLUSION: According to the findings of this systematic review, ICRPD has a reasonable survival/success rate, minimal bone loss, and high patient satisfaction.

14.
Cureus ; 16(8): e67019, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39280469

RESUMEN

Background Restorative dentists frequently deal with the prosthesis coming loose after placing multiple crowns. The luting cement holds indirect restorations to the prepared tooth. However, the success of the restorations is impacted by mastication pressures and other undesired factors. Therefore, escape is required to increase the crown's life. Mechanical locking of the prepared tooth surface is one technique to address this issue, in addition to cement adherence, to extend the life of the restoration. Aims and objective The objective of the study was to evaluate the influence of surface roughness of prepared teeth on the retention of metal crowns. Methodology This in-vitro investigation was carried out on freshly extracted maxillary first premolars that were defect-free and had the same crown size. Using multiple grifts of varied coarseness, different surface roughness was created, allowing for the observation of an important factor like retention (black at 180-250 µm [micrometer], blue at 125-150 µm, green at 106-125 µm, red at 53-63 µm, yellow at 20-30 µm). Results IBM Corp. Released 2011. IBM SPSS Statistics for Windows, Version 20.0. Armonk, NY: IBM Corp. was used to perform the statistical analysis. Compounds were done before it began to guarantee that the study would have 80% power. There is a mean and a standard deviation for each quantitative variable. A one-way ANOVA was used for quantitative variables, and Tukey's post hoc analysis was conducted afterward. A probability value of less than 0.05 was used to determine statistical significance. According to the statistical findings, the prosthesis's retentive qualities improve as coarseness increases. Conclusion The resistance and retention form of the preparation is critical to the longevity of the prosthesis, based on the findings of the previously described study. Surface roughness, pins, slots, grooves, and other preparation modifications can enhance retention on the prepared tooth surface. The research findings indicate no need to polish the prepared tooth surface.

15.
Cureus ; 16(8): e68053, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39206329

RESUMEN

BACKGROUND: Achieving clinically adequate retention for cast crowns in prepared short abutments represents a major challenge for practicing dentists. Despite the important developments with adhesive cement, only a few teeth can be treated this way, and conventional preparation techniques are still employed for most crowns. Numerous options for auxiliary features exist; however, there is no consensus about one preferred method. This study aimed to evaluate the effect of a new innovative technique called the "double finish line technique" on full-crown retention for short abutments and to compare it with another modified preparation method. MATERIAL AND METHODS: A comparative in vitro experimental study was conducted at the Department of Fixed Prosthodontics, Damascus University. The study sample consisted of 30 chromium-cobalt abutments and 30 metal crowns. The sample was divided into three equal groups. The first group was a control group (CG) with a 20-degree total occlusal convergence, 3 mm height, and a 0.5 mm chamfer finish line. The second group had a reduced total occlusal convergence (TOC) in the cervical 1.5 mm of the axial wall from 20 to 8 degrees. The third group implemented the so-called "double finish line technique," adding another 0.5 mm chamfer finish line 1 mm above the first finish line (DFL group). The metal crowns were cemented to metal dies with zinc-phosphate cement. Pull-off tests were applied until failure. Data were analyzed, and the differences between the three groups were detected using one-way ANOVA followed by Bonferroni's post-hoc tests (p<0.05). RESULTS: The mean tensile strength values for the specimens were 115.36 (SD=14.59), 149.60 (SD=11.10), and 42.46 (SD=11.54) for the TOC, DFL, and CR groups, respectively. CONCLUSION: The reduced total occlusal convergence and double finish line techniques effectively increased full crown retention and resistance cemented on short abutments.

16.
Cureus ; 16(7): e65282, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39184652

RESUMEN

Stainless steel crowns (SSC) have long been the standard choice due to their durability, ease of use, and cost-effectiveness. Other esthetic crowns, known for their superior esthetic properties and biocompatibility, have emerged as a popular option in recent years. A comprehensive literature search was conducted across multiple databases, including PubMed, Scopus, and Cochrane Library, up to June 2024. The population under study was primary teeth, with the intervention being the application of aesthetic crowns. These were compared against SSC, with the primary outcome being the level of microbial adhesion on the crowns in primary teeth. Data extraction and quality assessment were performed independently by two reviewers. Meta-analyses were conducted using random-effects models to estimate pooled differences in microbial adhesion levels. A total of five studies were included in the review. The meta-analysis revealed a statistically significant difference in microbial adhesion between esthetic and SSC, with esthetic crowns showing lower levels of bacterial colonization. Specifically, the mean difference in colony-forming units (CFU). Esthetic crowns exhibit significantly lower microbial adhesion compared to SSC in pediatric patients, suggesting a potential advantage in reducing the risk of secondary caries and other microbial-related complications. However, further long-term clinical studies are warranted to confirm these results and assess their clinical implications.

17.
Int J Clin Pediatr Dent ; 17(Suppl 1): S43-S54, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39185256

RESUMEN

Aim: The present randomized clinical trial is aimed at evaluating clinical efficiency of two different types of esthetic crowns-polymethyl methacrylate crowns and vacuum formed thermoformed crown as an alternative to full-coverage coronal restoration for deciduous molars. Materials and methods: A total of 45 primary molars in pediatric patients were selected using randomization and split into three groups based on the technique used for preparation of crowns: group I-polymethyl methacrylate crowns; group II-thermoformed crown; and group III-stainless steel crowns (SSC). All crowns were clinically and radiographically evaluated at baseline, 1st month, and 3rd month for gingival health, retention, marginal integrity, proximal contacts, occlusion, alignment, and staining. Statistical analysis: The data was tabulated and analyzed by Statistical Package for the Social Sciences (SPSS) Version 23.0 software. The intergroup comparison was done by Kruskal-Wallis test, analysis of variance (ANOVA), and Mann-Whitney U test for continuous data. The intragroup comparison was done by Friedman test and Wilcoxon signed-rank test for categorical data. All p-values < 0.05 were considered statistically significant. Results: With regard to the parameters of plaque score, gingival index score, occlusion, interproximal contacts, retention, alignment, and marginal adaptation, no statistical significance was noted between the three groups. However, with regard to the discoloration (staining) when the polymethyl methacrylate acrylic (PMMA) group was compared with thermoforming group, statistical significance was noted in 1st month with p-values of 0.04 and 0.03, respectively. On intragroup comparison, statistically significant values were obtained in SSC group for plaque score and thermoforming group for gingival index score. Clinical significance: The study concluded that the PMMA and thermoforming crowns can be used as an alternative to SSC for restoring the primary molars as they showed equivalent results to that of standard SSC. How to cite this article: Matha N, Kumar KS, Reddy BVT, et al. Comparative Evaluation of Polymethyl Methacrylate and Thermoforming Crowns as Semipermanent Crowns in Primary Molars: An In Vivo Study. Int J Clin Pediatr Dent 2024;17(S-1):S43-S54.

18.
J Am Dent Assoc ; 155(9): 765-773, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39101860

RESUMEN

BACKGROUND: The aim of this study was to assess factors associated with higher odds of undergoing repeat general anesthesia (GA2) for dental treatments. METHODS: The authors studied children up to age 48 months of age enrolled in Medicaid who underwent dental treatment under first general anesthesia (GA1). The authors used a case-control design to compare children who had a GA2 within 48 months of GA1 (case patients) with those who did not (control patients). RESULTS: In total, 60 case patients were age and sex matched to 120 control patients. Mean (SD) age at GA1 was 38 (5.2) months for case participants and 40 (4.7) months for control participants (P = .08). Higher caries involvement of maxillary incisors (P = .04), and lower caries involvment of canines (P = .003), first molars (P = .012), and second molars (P < .001) at GA1 was associated with higher odds of occurrence of GA2. There was a significant inverse association between full-coverage restoration on canines (P = .003), first molars (P = .001), and second molars (P = .002) at GA1 and occurrence of GA2. There was a significant direct association between the use of composites or sealants on second molars in GA1 and occurrence of GA2 (P = .02). The number of extractions at GA1 was not associated significantly with the occurrence of GA2. CONCLUSIONS: The use of full-coverage restorations on primary molars and canines under general anesthesia (GA) was associated with lower odds of occurrence of GA2. Resin restorations and sealants on primary second molars were associated with higher odds of occurrence repeat GA. The findings support preferential use of full-coverage restorations for young children undergoing dental GA. PRACTICAL IMPLICATIONS: Full-coverage restorations should be considered strongly for young children undergoing GA for dental treatments to reduce the risk of requiring GA2.


Asunto(s)
Anestesia Dental , Anestesia General , Caries Dental , Restauración Dental Permanente , Humanos , Estudios de Casos y Controles , Anestesia General/estadística & datos numéricos , Masculino , Femenino , Preescolar , Restauración Dental Permanente/métodos , Restauración Dental Permanente/estadística & datos numéricos , Anestesia Dental/métodos , Lactante , Diente Primario , Diente Molar , Diente Canino , Estados Unidos , Medicaid , Incisivo , Atención Dental para Niños/métodos , Factores de Riesgo , Resinas Compuestas/uso terapéutico
19.
Children (Basel) ; 11(8)2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39201926

RESUMEN

Retentive strength data are critical to predicting the long-term clinical performance of zirconia crowns for primary teeth. Objectives: This research assessed the clinical outcome of prefabricated zirconia crowns (PZCs) cemented with either self-adhesive resin cement or pure glass ionomer cement in the primary teeth of children. Method: In the present research, a sample of 162 prefabricated zirconia crowns were collected through convenience sampling. A follow-up examination was conducted at 12 and 24 months to assess the clinical outcomes of PZCs post cementation. Results: Zirconia crowns cemented with self-adhesive resin showed high clinical outcomes at both 12 and 24 months, with 95.1% of crowns retained. In contrast, crowns cemented with glass ionomer cement had slightly lower clinical outcomes, with 91.4% retained at 12 months and 84.0% retained at 24 months, indicating a significant difference (p-value). Long-term follow-up is crucial for the optimal maintenance of crown stability. Conclusions: Self-adhesive resin cement is a viable option for cementing PZCs in pediatric dentistry, demonstrating satisfactory clinical performance over both 12 and 24 months. Future studies comparing different types of cement are recommended for further validation of these results.

20.
Clin Case Rep ; 12(8): e9329, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39144064

RESUMEN

Key Clinical Message: Amelogenesis imperfecta (AI) is a rare developmental anomaly characterized by poorly developed or absent tooth enamel, which complicates orthodontic treatment due to weak enamel-bracket bond strength. This case report presents a successful management of AI using fixed orthodontic appliances and prosthodontic rehabilitation. Abstract: Amelogenesis imperfecta (AI) causes enamel defects, complicating oral hygiene, reducing masticatory function and lowering self-esteem. This case report details an 18-year-old female with AI who underwent fixed orthodontic treatment followed by prosthodontic rehabilitation. The multidisciplinary approach restored function and aesthetics, significantly improving her quality of life.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA