Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.515
Filtrar
1.
Swiss Dent J ; 134(3): 1-17, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38757922

RESUMEN

The concept of bilateral cantilevers on a single central implant (T-design) for three-unit implant-supported fixed dental prostheses (ISFDPs) has not been explored nor tested. This technical hypothesis aimed to explore the feasibility of such an approach as a cost-effective alternative to conventional treatments. Careful considerations regarding implant diameter, length, ideal position, occlusal scheme, and bone remodeling are essential to ensure adequate support, stability, and prevention of complications. In this proof of concept, we present a preliminary case with this novel design to replace missing posterior teeth in a patient with narrow bone conditions. In addition, a series of planned investigations and preliminary results, including preclinical studies, are presented to illustrate our concept and its potential clinical implications. Clinically, after two-year follow-up, healthy and stable peri-implant tissues around the ISFDP exemplarily demonstrated excellent stability, functionality, and comfort, which is supported by acceptable fracture resistance data in vitro, suggesting indeed the practical potential and suitability. Thus, we claim that such a treatment modality has the at least theoretical potential to revolutionize implant dentistry by providing innovative and cost-effective treatment options for patients with partial ISFDPs in very specific cases. Of course, further research and evaluations are necessary to validate the clinical implications of this innovative hypothesis. Implementing the 3-on-1 T-bridge approach in partial ISFDPs could offer a promising alternative to traditional methods. If proven successful, this technique may lead to significant advancements in clinical practice, providing a less invasive cost-effective treatment option.


Asunto(s)
Prótesis Dental de Soporte Implantado , Humanos , Prótesis Dental de Soporte Implantado/métodos , Prueba de Estudio Conceptual , Dentadura Parcial Fija , Diseño de Dentadura , Femenino
2.
Clin Oral Investig ; 28(6): 330, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38772987

RESUMEN

OBJECTIVES: The aim of this multi-center pilot study was to assess the viability and feasibility of a novel treatment concept - the canine-positioned single implant mandibular overdenture (c-SIMO), with the single implant placed on the patient's preferred chewing side instead of the midline. MATERIALS AND METHODS: Participants received a single implant in the canine region of their preferred chewing side, based on an Asymmetry Index observed during mastication. The pre-existing mandibular denture was transformed into a c-SIMO on a spherical attachment. The primary outcome was oral health-related quality of life (OHRQoL), measured with GOHAI and OHIP-EDENT. Secondary outcomes included denture satisfaction index (DSI), chewing efficiency (CE), maximum bite force (MBF), implant survival and success, and prosthetic maintenance. Data analysis included descriptive statistics and bivariate comparison tests. RESULTS: Fifteen participants received the c-SIMO treatment (mean age: 69.9 ± 7.0). Implant success and survival rates were 100% at 1 year. Patient-reported outcome measures improved significantly compared to pre-treatment values (OHIP-EDENT: p = 0.001; DSI: p = 0.001; GOHAI: p = 0.002). Masticatory outcomes also improved significantly (CE: p = 0.001; overall MBF: p = 0.005). Post-implant, MBF was significantly higher in the ipsilateral side compared to the contralateral side at 2 weeks (p = 0.019) and 3 months (p = 0.015), but no longer at T3 (p = 0.730). Common prosthodontic events included denture base adjustments (n = 17) and matrix activation (n = 9). CONCLUSIONS: This pilot study concludes that c-SIMO is a promising treatment option, and a potential alternative to the single midline implant overdenture. CLINICAL RELEVANCE: The novel treatment concept of a canine-positioned single implant mandibular overdenture could be a viable treatment alternative to the midline positioning.


Asunto(s)
Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Estudios de Factibilidad , Masticación , Calidad de Vida , Humanos , Proyectos Piloto , Anciano , Masculino , Femenino , Masticación/fisiología , Diente Canino , Implantes Dentales de Diente Único , Satisfacción del Paciente , Persona de Mediana Edad , Mandíbula , Diseño de Dentadura
3.
Medicina (Kaunas) ; 60(5)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38792903

RESUMEN

(1) Background: Recent digital workflows are being developed for full-arch rehabilitations supported by implants with immediate function. The purpose of this case series is to describe a new digital workflow for the All-on-4 concept. (2) Methods: The patients were rehabilitated using the All-on-4 concept with a digital workflow including computerized tomography scanning, intra-oral scanning, and CAD-CAM production of the temporary prosthesis, with the 3D printing of stackable guides (base guide, implant guide, and prosthetic guide). The passive fit of the prostheses and the time to perform the rehabilitations were evaluated. (3) Results: The digital workflow allowed for predictable bone reduction, the insertion of implants with immediate function, and the connection of an implant-supported prosthesis with immediate loading. The time registered to perform the full-arch rehabilitations (implant insertion, abutment connection, prosthesis connection) was below 2 hours and 30 min. No passive fit issues were noted. (4) Conclusions: within the limitation of this case series, the digital workflow applied to the All-on-4 concept using stackable base-, implant-, and prosthetic guides constitutes a potential alternative with decreased time for the procedure without prejudice of the outcome.


Asunto(s)
Flujo de Trabajo , Humanos , Femenino , Masculino , Persona de Mediana Edad , Diseño Asistido por Computadora , Anciano , Prótesis Dental de Soporte Implantado/métodos , Impresión Tridimensional , Tomografía Computarizada por Rayos X/métodos , Boca Edéntula/rehabilitación
4.
Dent J (Basel) ; 12(5)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38786528

RESUMEN

OBJECTIVE: Familial isolated hypoparathyroidism is a rare genetic disorder due to no or low production of the parathyroid hormone, disturbing calcium and phosphate regulation. The resulting hypocalcemia may lead to dental abnormalities, such as enamel hypoplasia. The aim of this paper was to describe the full-mouth rehabilitation of a 15-year-old girl with chronic hypocalcemia due to a rare congenital hypoparathyroidism. CLINICAL CONSIDERATIONS: In this patient, in the young adult dentition, conservative care was preferred. Onlays or stainless-steel crowns were performed on the posterior teeth, and direct or indirect (overlays and veneerlays) were performed on the maxillary premolars, canines, and incisors, using a digital wax-up. The mandibular incisors were bleached. The treatment clearly improved the patient's oral quality of life, with fewer sensitivities, better chewing, and aesthetic satisfaction. The difficulties were the regular monitoring and the limited compliance of the patient. CONCLUSION: Despite no clinical feedback in the literature, generalized hypomineralized/hypoplastic teeth due to hypoparathyroidism in a young patient can be treated as amelogenesis imperfecta (generalized enamel defects) with a conservative approach for medium-term satisfactory results. HIGHLIGHTS: This study provides new insights into the management of enamel hypoplasia caused by familial isolated hypoparathyroidism, helping to improve patient outcomes in similar cases.

5.
J Dent ; 146: 105072, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38763387

RESUMEN

OBJECTIVES: This study aimed to compare the effect the radiographic marker registration (RMR) and markerless tracing registration (MTR) on implant placement accuracy using a dynamic computer-assisted implant surgery system (dCAIS). Additionally, this study aimed to assess the surgical time and whether the implant location influences the accuracy of the two registration methods. METHODS: 136 dental implants were randomly allocated to the RMR or MTR group and were placed with a dCAIS in resin models. Preoperative and postoperative Cone Beam Computer Tomograms (CBCT) were overlaid and implant placement accuracy was assessed. Descriptive and multivariate analysis of the data was performed. RESULTS: Significant differences (P < 0.001) were found for all accuracy variables except angular deviation (RMR:4.30° (SD:4.37°); MTR:3.89° (SD:3.32°)). The RMR had a mean 3D platform deviation of 1.53 mm (SD:0.98 mm) and mean apex 3D deviation of 1.63 mm (SD:1.05 mm) while the MTR had lower values (0.83 mm (SD:0.67 mm) and 1.07 mm (SD:0.86 mm), respectively). In the MTR group, implant placement in the anterior mandible was more accurate (p < 0.05). Additionally, MTR did not significantly increase the surgical time compared with RMR (P = 0.489). CONCLUSIONS: MTR seems to increase the accuracy of implant placement using dCAIS in comparison with the RMR method, without increasing the surgical time. The operated area seems to be relevant and might influence the implant deviations. CLINICAL SIGNIFICANCE: Considering the limitations of this in-vitro study, MTR seems to provide a higher accuracy in implant placement using dCAIS without increasing the surgical time. Furthermore, this method does not require radiographic markers and allows re-registration during surgery.

6.
Eur J Oral Sci ; : e12992, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38771146

RESUMEN

Finite element analysis (FEA) has been used to analyze the behavior of dental materials, mainly in implantology. However, FEA is a mechanical analysis and few studies have tried to simulate the biological characteristics of the healing process of loaded implants. This study used the rule of mixtures to simulate the biological healing process of immediate implants in an alveolus socket and bone-implant junction interface through FEA. Three-dimensional geometric models of the structures were obtained, and material properties were derived from the literature. The rule of mixtures was used to simulate the healing periods-immediate and early loading, in which the concentration of each cell type, based on in vivo studies, influenced the final elastic moduli. A 100 N occlusal load was simulated in axial and oblique directions. The models were evaluated for maximum and minimum principal strains, and the bone overload was assessed through Frost's mechanostat. There was a higher strain concentration in the healing regions and cortical bone tissue near the cervical portion. The bone overload was higher in the immediate load condition. The method used in this study may help to simulate the biological healing process and could be useful to relate FEA results to clinical practice.

7.
Future Microbiol ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700286

RESUMEN

Aim: To evaluate the biological and mechanical properties of an adhesive with nanostructured silver vanadate (AgVO3). Materials & methods: Specimens in poly(methyl methacrylate) (PMMA) were treated with Ultra Corega Cream (UCCA) denture adhesive with or without AgVO3. Biofilms of Candida albicans, Candida glabrata and Streptococcus mutans were grown and the viable cells counted. Fluorescence microscopy was used. The viability of the VERO cell and adhesive strength were evaluated. Results: All concentrations of AgVO3 reduced the biofilm formation and showed no cytotoxic effect. At 5 min and 24 h, UCCA with 5 and 10% AgVO3 showed better performance, respectively. Conclusion: AgVO3 promoted the antibiofilm activity of the adhesive, with a positive effect on the adhesive strength, and was biocompatible.


What is this summary about? Some people wear false teeth called dentures. They use a special glue to keep these false teeth in their mouths. It is important to clean dentures well and remove the glue every day. If the dentures get dirty, they can cause infections of the gums. Doctors and dentists can help, but sometimes medicines do not work well. This study checked to see whether adding a medicine that can kill bacteria into the glue could stop gum swelling and other illnesses, or make them better. What were the results? The glue containing the medicine killed microbes like fungi and bacteria. It also stuck things together well and was safe to use. What do the results mean? Using this special glue could help people with dentures to avoid illness.

8.
J Dent Educ ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741343

RESUMEN

AIMS: In the literature, it is still unclear if the decisions for selecting the type of implant crown-retaining system are based on scientific-based research or if the Universities' choices, Implant marketing trends, or finances could have a major influence on the private dentists' decisions. OBJECTIVES: Therefore, this study aimed to evaluate the crown-retaining system (cement- or screw-retained) used in dental schools and private dental practices. METHODS: A 13-item questionnaire was sent to Canadian dental schools (n = 10) and dental offices in London (n = 298), Canada. The questionnaire included demographic questions and questions to reveal the dentists' perspectives on prosthetic implant treatment between the two-retaining systems. Results were analyzed using descriptive statistics and multinomial logistic regression (p = 0.05). RESULTS: Twenty-four private dentists and five dental schools responded to the survey - 62.5% of private practitioners and 60% of universities reported using both systems. A trend was observed in using screw-retained systems by dentists who graduated 5-10 years ago. Straumann, Astra, and Nobel Biocare were the private practices and dental schools' preferred implant systems. The use of platform switching for all cases was selected by 54.2% of the private practitioners and 40% of the dental schools. Resin cement was the private practice's preferred cementation method; the dental schools used glass ionomer and zinc phosphate cement. The multinomial logistic regressions showed no statistical difference between the crown-retaining system chosen and the decision factors. The laboratory technician's recommendations and cost influenced the decision-making process for private dentists. For the universities, perio-restorative outcome, implant position, survival rates, institute preferences, and evidence-based research influenced the crown-retaining system's decision-making process.  CONCLUSION: The Canadian dental schools and private practice reported using both screw- and cement-retaining systems. However, there was a difference in the selection criteria as the universities showed a tendency towards a more research-based approach in their decision, while for the private practices, the technicians' recommendations and cost played a major role in the decision process. It was noted that the implant systems preconized by the Universities were observed to be used in private practices.

9.
Front Artif Intell ; 7: 1339193, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38690195

RESUMEN

Background and objective: Due to the high prevalence of dental caries, fixed dental restorations are regularly required to restore compromised teeth or replace missing teeth while retaining function and aesthetic appearance. The fabrication of dental restorations, however, remains challenging due to the complexity of the human masticatory system as well as the unique morphology of each individual dentition. Adaptation and reworking are frequently required during the insertion of fixed dental prostheses (FDPs), which increase cost and treatment time. This article proposes a data-driven approach for the partial reconstruction of occlusal surfaces based on a data set that comprises 92 3D mesh files of full dental crown restorations. Methods: A Generative Adversarial Network (GAN) is considered for the given task in view of its ability to represent extensive data sets in an unsupervised manner with a wide variety of applications. Having demonstrated good capabilities in terms of image quality and training stability, StyleGAN-2 has been chosen as the main network for generating the occlusal surfaces. A 2D projection method is proposed in order to generate 2D representations of the provided 3D tooth data set for integration with the StyleGAN architecture. The reconstruction capabilities of the trained network are demonstrated by means of 4 common inlay types using a Bayesian Image Reconstruction method. This involves pre-processing the data in order to extract the necessary information of the tooth preparations required for the used method as well as the modification of the initial reconstruction loss. Results: The reconstruction process yields satisfactory visual and quantitative results for all preparations with a root mean square error (RMSE) ranging from 0.02 mm to 0.18 mm. When compared against a clinical procedure for CAD inlay fabrication, the group of dentists preferred the GAN-based restorations for 3 of the total 4 inlay geometries. Conclusions: This article shows the effectiveness of the StyleGAN architecture with a downstream optimization process for the reconstruction of 4 different inlay geometries. The independence of the reconstruction process and the initial training of the GAN enables the application of the method for arbitrary inlay geometries without time-consuming retraining of the GAN.

10.
J Prosthodont ; 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734932

RESUMEN

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

11.
J Esthet Restor Dent ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689391

RESUMEN

OBJECTIVES: To validate the reproducibility and inter/intra-observer variability of the Pink Esthetic Score/White Esthetic Score (PES/WES) of single tooth-supported prostheses in the maxillary esthetic zone (13-23). MATERIALS AND METHODS: Forty-five patients were randomly assigned to one of the three treatment options (15 patients per group) receiving each one a different crown type: Porcelain fused to metal (PFM), monolithic zirconia, and lithium disilicate. Eight observers from each of four different specialties (Prosthodontists, Orthodontists, Periodontists, and Oral Surgeons) were recruited and assessed twice and four weeks apart (i.e., T1 and T2) 45 photographs of the single tooth-supported prosthesis using PES/WES and compared them with contralateral teeth. RESULTS: According to the ANOVA and post hoc tests, the zirconia crown type obtained the highest mean score by all observers, with a mean value of 16.70 ± 2.94. The prosthodontists and oral surgeons assigned the lowest mean score to PFM crowns, 13.03 ± 3.47 and 13.80 ± 3.17, respectively. Notably, the prosthodontists awarded the highest scores, specifically 17.50 ± 2.81 for the zirconia crowns. Intraobserver agreement was calculated utilizing the paired t-test. Pairwise comparisons between observers of different specialties revealed significant intraobserver agreement. Interclass correlation coefficient (ICC) scores were statistically significant among four specialties. No difference was detected concerning the interobserver agreement. CONCLUSIONS: The PES/WES index remains consistent across various observers from different specializations, yielding uniform results in the overall esthetic evaluation. Consequently, in light of the presented preliminary positive results, its use might also be considered for the esthetic assessment of single-tooth-supported prostheses. CLINICAL SIGNIFICANCE: The PES/WES index may be employed clinically to evaluate single tooth-supported prostheses as it emerged as a reproducible esthetic scoring system.

12.
Clin Oral Investig ; 28(5): 278, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671152

RESUMEN

OBJECTIVES: To determine the prevalence of peri-implant diseases in patients treated in a university setting without a regular peri-implant supportive therapy schedule, and to identify the risk indicators associated with peri-implantitis. MATERIAL AND METHODS: A retrospective cohort study was made of patients with dental implants with at least 12 months of functional loading who did not receive regular peri-implant supportive therapy. Patient- and implant-related variables were retrieved, and clinical and radiological examinations were performed. Descriptive and bivariate analyses and multilevel logistic regression analyses were performed to identify factors associated with peri-implantitis. RESULTS: A total of 213 implants in 88 patients were analyzed. The patient-level prevalence of peri-implantitis and peri-implant mucositis was 26.1% (95%CI: 16.7%-35.5%) and 44.3% (95%CI: 34.0%-54.6%), respectively. Peri-implant diseases were significantly more frequent when the width of the keratinized mucosa was < 2 mm (OR = 5.26; 95%CI: 1.24-22.26; p = 0.024), and when there was 12 month post-loading bone loss (OR = 2.96; 95%CI: 1.35-6.52; p = 0.007). CONCLUSIONS: Peri-implantitis is a common finding in patients without regular peri-implant supportive therapy (prevalence 16.7-35.5%). A thin peri-implant keratinized mucosa (< 2 mm) and a higher degree of bone remodeling after loading seem to be the main risk factors for peri-implantitis in this patient profile. CLINICAL RELEVANCE: Patients who do not engage in supportive peri-implant maintenance have a higher risk of peri-implantitis. A thin keratinized mucosa and bone loss during the first year of loading are predisposing factors for peri-implantitis.


Asunto(s)
Periimplantitis , Humanos , Periimplantitis/epidemiología , Periimplantitis/etiología , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Prevalencia , Anciano , Implantes Dentales/efectos adversos , Adulto
13.
J Mech Behav Biomed Mater ; 155: 106538, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38608345

RESUMEN

OBJECTIVES: An alternative option was proposed regarding the prosthetic rehabilitation of a fully edentulous mandible using only four implants. The aim was to reduce the stiffness of the prosthetic framework. To that end, the alternative option consists of a prosthetic framework optimized with a porous structure. Mechanical differences were analyzed between non-prosthetic mandible and restored mandible either with a conventional bulk titanium framework or with this alternative option. The non-prosthetic mandible corresponds to the mandible in its natural state, without prosthesis. This will be considered as the reference for comparison with restored models (mandible with prosthesis). METHODS: Three models are used: the first one is the non-prosthetic mandible, the second one is the restored mandible with conventional bulk titanium prosthetic framework, and the third one is the alternative option. Prosthetic framework was optimized with the use of a lattice structure. A numerical analysis was performed (with Abaqus Standard software®) to obtain the effective parameters corresponding to equivalent homogeneous behavior. In the 3 models, physiological boundary conditions were used, considering the activity of several muscles of the masticatory system during three main tasks of mastication (incisive clenching, maximum intercuspation and unilateral molar clenching). RESULTS: Numerical simulations allowed to obtain mandibular global kinematics, local displacement at the bone-implant interface and the state of strain at the bone-implant interface, for each masticatory tasks. For this comparative study, the non-prosthetic mandible model was used as a reference to observe the benefits of using a lattice prosthetic framework compared to a conventional bulk titanium framework. CONCLUSION: Compared to conventional titanium framework, the lattice prosthetic one appeared to be more respectful of the natural mandible kinematics, given by the reference model. It also resulted in strain values within the physiological loading range.


Asunto(s)
Análisis de Elementos Finitos , Mandíbula , Mandíbula/fisiología , Fenómenos Mecánicos , Titanio/química , Fenómenos Biomecánicos , Humanos
14.
SAGE Open Med Case Rep ; 12: 2050313X241241191, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38559405

RESUMEN

New surgical techniques using narrow, tilted implants positioned through a magneto-dynamic tool in guided surgery for a Toronto restoration. A 69-year-old woman wanted fixed rehabilitation to replace her removable complete dentures. A cone-beam computed tomography showed significant bone resorption in both the maxillary and mandibular regions. The plan was to load the entire upper arch with six implants immediately, while removable partial dentures were recommended for the lower jaw. The guided surgery project was aligned with the new dentures, and the laboratory created a printed cast with dental implant analogues in planned positions. A metal-reinforced denture was constructed, and surgery was performed to place six narrow implants using the magneto-dynamic instrument. The denture was directly screwed onto multi-unit abutments. Final rehabilitation was completed after 6 months. Narrow implants can be a good option for fixed, full-arch rehabilitations. Further research is needed to confirm these findings on a larger scale.

15.
Quintessence Int ; 0(0): 0, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619260

RESUMEN

OBJECTIVES: This systematic review compares the impact of ball and locator attachments on marginal bone loss in implant-retained overdentures in completely edentulous patients. METHOD AND MATERIALS: Following PRISMA guidelines, health science librarians completed literature searches from inception to March 17, 2023 in seven databases. There were 15,686 items exported to EndNote from Embase.com, CINAHL (EBSCO), Cochrane Library, Ovid MEDLINE-ALL, PubMed, Scopus, and Web of Science. Hand-searching added four more articles. After deduplication, 6756 items were screened for eligibility. Twenty-nine studies were assessed by full text, of which ten studies, involving 424 subjects, were included in the review. Risk of bias assessment was conducted using the Cochrane Risk of Bias tool and the Newcastle Ottawa Scale. A meta-analysis was performed to synthesize and analyze the collective data from the selected studies. RESULTS: The included studies used diverse methodologies, implant systems, and loading protocols. Most studies reported no significant difference in marginal bone loss between ball and locator attachments. The meta-analysis revealed high heterogeneity. CONCLUSION: The results of this systematic review suggest that ball and locator attachments exhibit similar performance in terms of marginal bone loss in implant-retained overdentures. However, the limited number, risk of bias, and heterogeneity of studies highlight the need for standardized research designs and larger sample sizes in future investigations to draw more definitive conclusions.

16.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579114

RESUMEN

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Asunto(s)
Implantes Dentales , Torque , Pilares Dentales , Análisis del Estrés Dental , Retención de Prótesis Dentales , Diseño de Implante Dental-Pilar
17.
Trials ; 25(1): 267, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627819

RESUMEN

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Humanos , Anciano , Persona de Mediana Edad , Prótesis de Recubrimiento , Flujo de Trabajo , Mandíbula/cirugía , Satisfacción del Paciente , Impresión Tridimensional , Prótesis Dental de Soporte Implantado , Ensayos Clínicos Controlados Aleatorios como Asunto
18.
J Dent ; 145: 104988, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38608832

RESUMEN

OBJECTIVES: This study aims to explore and discuss recent advancements in tooth reconstruction utilizing deep learning (DL) techniques. A review on new DL methodologies in partial and full tooth reconstruction is conducted. DATA/SOURCES: PubMed, Google Scholar, and IEEE Xplore databases were searched for articles from 2003 to 2023. STUDY SELECTION: The review includes 9 articles published from 2018 to 2023. The selected articles showcase novel DL approaches for tooth reconstruction, while those concentrating solely on the application or review of DL methods are excluded. The review shows that data is acquired via intraoral scans or laboratory scans of dental plaster models. Common data representations are depth maps, point clouds, and voxelized point clouds. Reconstructions focus on single teeth, using data from adjacent teeth or the entire jaw. Some articles include antagonist teeth data and features like occlusal grooves and gap distance. Primary network architectures include Generative Adversarial Networks (GANs) and Transformers. Compared to conventional digital methods, DL-based tooth reconstruction reports error rates approximately two times lower. CONCLUSIONS: Generative DL models analyze dental datasets to reconstruct missing teeth by extracting insights into patterns and structures. Through specialized application, these models reconstruct morphologically and functionally sound dental structures, leveraging information from the existing teeth. The reported advancements facilitate the feasibility of DL-based dental crown reconstruction. Beyond GANs and Transformers with point clouds or voxels, recent studies indicate promising outcomes with diffusion-based architectures and innovative data representations like wavelets for 3D shape completion and inference problems. CLINICAL SIGNIFICANCE: Generative network architectures employed in the analysis and reconstruction of dental structures demonstrate notable proficiency. The enhanced accuracy and efficiency of DL-based frameworks hold the potential to enhance clinical outcomes and increase patient satisfaction. The reduced reconstruction times and diminished requirement for manual intervention may lead to cost savings and improved accessibility of dental services.


Asunto(s)
Aprendizaje Profundo , Humanos , Diseño de Prótesis Dental/métodos , Restauración Dental Permanente/métodos , Diseño Asistido por Computadora , Modelos Dentales , Diente/anatomía & histología
19.
J Oral Implantol ; 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38600837

RESUMEN

Various factors influence marginal bone loss following implant placement. This study explored the association between marginal bone loss and posterior implants positioned at different bone levels. Computer records and radiographs of patients with at least two adjacent implants were retrieved. Cases were categorized into non-splinted prosthesis and splinted prosthesis groups. Radiographic measurements were conducted at the time of abutment placement (T0), 1-3 years follow-up (T1), and the last visit (T2), measuring the vertical distance between adjacent implants. Multilevel linear regression models using generalized estimating equations were employed, with a significance level set at 5% (α=0.05). Fifty-six patient records were included, comprising 120 implants: 84 non-splinted (70%) and 36 splinted (30%). In the non-splinted group, marginal bone loss progression significantly depended on crestal height differences. For the mesial sides of posterior implants, marginal bone loss measured 1.0 ± 0.6 mm from T0 to T1, 2.4 ± 1.1 mm from T1 to T2, and 3.4 ± 1.2 mm from T0 to T2. Similarly, the distal sides of the most anteriorly placed implant exhibited marginal bone loss of 1.0 ± 0.7 mm from T0 to T1, 2.4 ± 1.0 mm from T1 to T2, and 3.5 ± 1.2 mm from T0 to T2. Non-splinted implants demonstrated a higher progression of marginal bone loss. This study suggests that non-splinted implants may lead to a more pronounced progression of marginal bone loss, particularly concerning crestal height differences, underscoring the need for further research.

20.
Rev. Odontol. Araçatuba (Impr.) ; 45(1): 9-15, jan.-abr. 2024.
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1553247

RESUMEN

A evolução dos tratamentos em implantodontia possibilitou uma mudança nos tratamentos reabilitadores para pacientes edêntulos, tornando possível a colocação de próteses fixas, que proporcionam maior qualidade de vida para estes pacientes. Para que estas próteses tenham bom desempenho e longevidade satisfatórios é essencial que se mantenha um padrão adequado de higienização bucal e manutenção profissional. Assim, o objetivo deste trabalho foi realizar uma revisão de literatura a respeito dos principais recursos disponíveis para higienização e manutenção das próteses totais fixas sobre implante (protocolo de Branemark), tanto nos cuidados domiciliares dos pacientes quanto no atendimento profissional do cirurgião dentista. Foi realizada uma busca eletrônica, não sistemática, nas bases de dados Lilacs, Pubmed/Medline, Scielo e ScienceDirect, cruzando-se os seguintes descritores: "Higiene Oral"; "Implantes Dentários"; "Implantação Dentária"; "Manutenção"; "Prótese Dentária Fixada por Implante" e "Prótese Dentária". Foram consultados artigos de revisão de literatura, revisão sistemática, meta-análise, estudos clínicos randomizados, além de livros pertinentes ao assunto, publicados no período de 1995 a 2022.Verificou-se na literatura disponível que os principais instrumentos indicados para uso domiciliar são escova dental, fio dental, escova interdental, irrigador oral, dentifrício e enxaguatório. No atendimento profissional em consultório odontológico deve ser dispendida atenção especial às instruções passadas ao paciente e também fazer o possível para motivar e encorajar o seu engajamento na rotina de higienização, além do acompanhamento periodontal, possíveis substituições de parafusos e instalação de placa oclusal estabilizadora, quando necessário. Manter uma higiene oral adequada é essencial para o sucesso das próteses fixas sobre implantes e o cirurgião dentista desempenha um papel crucial não apenas ao realizar o acompanhamento periódico do paciente, mas também ao sugerir os instrumentos mais apropriados, instruir sobre a higiene oral adequada e motivar o paciente a manter a saúde bucal satisfatória(AU)


The evolution of treatments in implantology has enable a change in rehabilitation treatments for edentulous patients, making it possible to place fixed prostheses that provide a better quality of life for these patients. In order to ensure good performance and satisfactory longevity, it is essential to maintain an appropriate standard of oral hygiene and professional maintenance. Thus, the objective of this work was to conduct a literature review on the main resources available for cleaning and maintenance of complete fixed prostheses on implants (Branemark protocol), both in the patients' home care and in the professional care provided by the dentist. A nonsystematic electronic search was carried out in the Lilacs, Pubmed/Medline, Scielo, and ScienceDirect databases, crossing the following descriptors: "Oral Hygiene"; "Dental Implants"; "Dental Implantation"; "Maintenance"; "Dental Prosthesis, ImplantSupported"; and "Prosthodontics". Literature review articles, systematic reviews, meta-analyses, randomized clinical studies, and relevant books on the subject published from 1995 to 2022 were consulted. The literature available indicates that the main instruments recommended for home care are toothbrush, dental floss, interdental brush, oral irrigator, toothpaste, and mouthwash. In the professional dental office, special attention should be given to the instructions given to the patient, as well as to motivate and encourage their engagement in the hygiene routine, in addition to periodontal monitoring, possible screw replacements, and installation of an occlusal splint when necessary. Maintaining adequate oral hygiene is essential for the success of fixed prostheses on implants, and the dentist plays a crucial role, not only in providing periodic patient follow-up, but also in suggesting the most appropriate instruments, instructing on adequate oral hygiene, and motivating the patient to maintain satisfactory oral health(AU)


Asunto(s)
Atención Odontológica , Odontología Preventiva , Prótesis Dental de Soporte Implantado/métodos , Dentífricos , Odontólogos , Antisépticos Bucales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...