Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.376
Filtrar
1.
J Prosthodont ; 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734933

RESUMEN

PURPOSE: To evaluate the effect of different printing orientations and post-polymerization time with thermal cycling on the translucency of 3D-printed denture base resins. METHODS: Heat-polymerized (HP) acrylic resin specimens were fabricated and 3D-printed denture base materials (NextDent, ASIGA, FormLabs) were printed with different printing orientations (0, 45, 90 degrees) and subjected to different post-polymerization times (15-, 30-, 60-, and 90-min). All specimens were polished and immersed in distilled water for 1 day at 37°C. CIEDE2000 was used to measure the translucency parameters (TP00) before and after thermal cycling (5000 cycles) recording the color parameters (L*, a*, b*) against a black and white background using a spectrophotometer. k-factors ANOVA followed by post hoc Tukey's test (α = .05) was performed for statistical analysis. RESULTS: The k-factors ANOVA test showed a significant effect of resin material, post-polymerization time, and printing orientation on translucency (p < 0.001). In comparison to HP, all 3D-printed resins showed lower translucency with all post-polymerization times and printing orientation (p < 0.001) except FormLabs resin (p > 0.05). For all 3D-printed resins, the translucency increased, with increasing the post-polymerization time (p < 0.001) and 60- and 90-min showed the highest translucency. For printing orientation, 90 and 45 degrees significantly showed high translucency in comparison to 0 degrees (p < 0.001). FormLabs showed significantly higher translucency when compared with NextDent and ASIGA per respective printing orientation and post-polymerization time. The translucency significantly decreased after thermal cycling for all tested resins (p < 0.001). CONCLUSION: The findings of this study demonstrated that the translucency of 3D-printed resins is influenced by the printing orientation, post-polymerization time, and resin type. As a result, choosing a resin type, and printing orientation, with a longer post-polymerization time should be considered since it may improve the esthetic appearance of the 3D-printed resins.

2.
Cureus ; 16(4): e58220, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38745795

RESUMEN

The most common complication post COVID-19is mucormycosis. It is an opportunistic infection caused by the fungus mucormycetes which belongs to the order Mucorales. This infection can spread from the oral cavity to the nasal cavity and sometimes also involve the orbit. Surgical resection of the affected region followed by its prosthetic rehabilitation is one of the viable treatment options. In this case report, we will discuss the problems in designing and fabricating a hollow bulb obturator and its solutions.

3.
J Esthet Restor Dent ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747067

RESUMEN

OBJECTIVE: This study aimed to examine the shear bond strength (SBS) of repair material to conventionally, subtractive-, and additive-manufactured denture bases after different surface treatments. MATERIALS AND METHODS: Disk-shaped test specimens (N = 300) were prepared from denture base materials produced by one conventional (Procryla), one subtractive (Yamahachi), and one additive (Curo Denture) method. The test specimens were randomly divided into five groups (n = 10) and exposed to a variety of surface treatments-Group A: no surface treatment; Group B: grinding with silicon carbide paper; Group C: sandblasting; Group D: erbium: yttrium-aluminum-garnet laser; and Group E: plasma. Repair was performed with autopolymerizing acrylic resin (Meliodent). Surface roughness analyses were performed with a profilometer. Scanning electron microscopy was used to examine one specimen from each subgroup. SBS was evaluated on a universal testing machine. Failure types were observed under a stereomicroscope. RESULTS: Surface roughness values were significantly higher in all test materials in Group D than in the other groups (p < 0.001). For conventional resin, the SBS values were higher in Group C than in Groups A, D, and E (p < 0.001). For CAD/CAM material, Groups B and C had significantly greater SBS increases compared with Group E (p < 0.001). For 3D material, Group D showed higher SBS than all groups except Group C (p < 0.001). CONCLUSIONS: For SBS, sandblasting was most effective in the conventional group, whereas laser treatment was the most effective in the additive-manufactured group. For the subtractive group, surface treatments other than plasma exhibited similar SBS. CLINICAL SIGNIFICANCE: In repairing fractured prostheses, any degree of roughening suitable for the material content may provide an SBS benefit.

4.
J Appl Microbiol ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38744659

RESUMEN

AIM: This study investigated the effectiveness of a drug-modified tissue conditioner in an animal model of denture stomatitis. METHODS AND RESULTS: Wistar rats wore a Candida albicans-contaminated palatal device for four days. Next, nystatin (Nys) or chlorhexidine (Chx) were added to a tissue conditioner in their raw or ß-cyclodextrin-complexed (ßCD) forms at their minimum inhibitory concentrations. As controls, one group was not subjected to any procedure (NC), one group used sterile devices (SD), one group had denture stomatitis but was not treated (DS), and another had the devices relined with the tissue conditioner without the addition of any drug (Soft). After four days of treatment, treatment effectiveness was assessed visually, histologically, and through CFU count, and myeloperoxidase (MPO) and N-acetylglucosaminidase (NAG) assays. Rats from the Soft, Nys, Nys:ßCD, and Chx groups presented a significant decrease in the microbial load compared to the untreated group. Treatment groups showed lower MPO and NAG activity compared to the non-treated group. CONCLUSIONS: The addition of antifungals to a soft tissue conditioner can be a promising approach for denture stomatitis treatment.

5.
PeerJ ; 12: e17268, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38708351

RESUMEN

Objective: To study the efficacy of PADTM Plus-based photoactivated disinfection (PAD) for treating denture stomatitis (DS) in diabetic rats by establishing a diabetic rat DS model. Methods: The diabetic rat DS model was developed by randomly selecting 2-month-old male Sprague-Dawley rats and dividing them into four groups. The palate and denture surfaces of rats in the PAD groups were incubated with 1 mg/mL toluidine blue O for 1 min each, followed by a 1-min exposure to 750-mW light-emitting diode light. The PAD-1 group received one radiation treatment, and the PAD-2 group received three radiation treatments over 5 days with a 1-day interval. The nystatin (NYS) group received treatment for 5 days with a suspension of NYS of 100,000 IU. The infection group did not receive any treatment. In each group, assessments included an inflammation score of the palate, tests for fungal load, histological evaluation, and immunohistochemical detection of interleukin-17 (IL-17) and tumor necrosis factor (TNF-α) conducted 1 and 7 days following the conclusion of treatment. Results: One day after treatment, the fungal load on the palate and dentures, as well as the mean optical density values of IL-17 and TNF-α, were found to be greater in the infection group than in the other three treatment groups (P < 0.05). On the 7th day after treatment, these values were significantly higher in the infection group than in the PAD-2 and NYS groups (P < 0.05). Importantly, there were no differences between the infection and PAD-1 groups nor between the PAD-2 and NYS groups (P > 0.05). Conclusions: PAD effectively reduced the fungal load and the expressions of IL-17 and TNF-α in the palate and denture of diabetic DS rats. The efficacy of multiple-light treatments was superior to that of single-light treatments and similar to that of NYS.


Asunto(s)
Diabetes Mellitus Experimental , Desinfección , Ratas Sprague-Dawley , Estomatitis Subprotética , Animales , Masculino , Ratas , Estomatitis Subprotética/microbiología , Estomatitis Subprotética/radioterapia , Estomatitis Subprotética/tratamiento farmacológico , Desinfección/métodos , Cloruro de Tolonio/farmacología , Cloruro de Tolonio/uso terapéutico , Factor de Necrosis Tumoral alfa/metabolismo , Interleucina-17/metabolismo , Modelos Animales de Enfermedad
6.
Int J Health Sci (Qassim) ; 18(3): 23-29, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721136

RESUMEN

Objectives: Reinforcement of polymethylmethacrylate (PMMA) denture base resins (DBRs) with inorganic fillers with superior properties and accepted aesthetics are favored and still a big dilemma. This study was undertaken to evaluate the color change, flexural strength, and modulus of elasticity of heat-polymerized DBR material modified with silver nanoparticles (AgNPs) and zirconium dioxide nanoparticles (ZNPs). Methods: Sixty acrylic specimens (30/color test, 30/flexural properties) were fabricated and divided according to nanoparticles type and addition into 3 groups (n = 10). Group-I; unmodified specimens, Group-II; modified specimens with 0.5wt% AgNPs (PMMA/AgNPs), and Group-III; modified specimens with 7.5wt% ZNPs (PMMA/ZNPs). Disc-shape (20 × 3 mm) and bar-shape (65 × 10 × 2.5 mm) specimens were fabricated for color and flexural properties, respectively. The spectrophotometer was used for evaluation of the color change (∆E). The flexural strength and elastic modulus evaluation was carried out using a 3-point bending test (5 mm/min). Tukey's post hoc and one-way ANOVA were used to analyze the data at a significant level P ≤ 0.05. Results: PMMA/AgNPs group exhibited a significant increase in color change when compared with PMMA/ZNPs. PMMA/ZNPs showed significantly the highest flexural strength value when compared with unmodified and PMMA/AgNPs groups (P < 0.001), however, there was an absence of significant differences in terms of flexural strength values between PMMA/AgNPs and unmodified groups (P > 0.05). PMMA/AgNPs insignificantly increased its modulus of elasticity strength (P = 0.09410) while PMMA/ZNPs significantly increased its modulus of elasticity strength (P = 0.00396). Conclusion: The AgNPs and ZNPs addition to PMMA increased the color change and AgNPs change the color of DBRs. The flexural attributes of DBRs have been increased by ZNPs.

7.
Int J Prosthodont ; 0(0): 1-15, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38727620

RESUMEN

OBJECTIVE: Evaluate the roughness and color stability of different types of resins used to immerse denture bases in various denture cleansers overnight. METODOLOGY: A total of 150 resin samples were made, which were divided into 3 groups of denture resin (conventional thermally activated, milled and 3D printed) (n= 50) and subdivided into 5 denture cleaners (Distilled water, Corega Tabs, Efferdent, NaOCl 1.0%, Listerine Cool Hint) (n= 10). The roughness properties (Ra) and chromatic difference (ΔE00) were evaluated during 90 days and 180 days of overnight cleaning. Data were evaluated by two-way ANOVA and Tukey's test for multiple comparisons (P<.05). RESULTS: Listerine had significantly higher Ra and ΔE values (P<.001) compared to other solutions, being significant in conventional resin at 180 days (P<.001). CONCLUSIONS: The use of Listerine as an overnight cleaner presents greater damage to the optical and surface properties of denture base resins, mainly with conventional resin, with 1% NaOCl being a valid option in relation to cost-benefit.

8.
J Prosthodont ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38706435

RESUMEN

Digital complete dentures fabricated using a mucostatic impression, like intraoral scans, are desirable for their beneficial effect on long-term residual ridge stability but may have less retention than those fabricated with a mucocompressive impression. Border molding procedure may improve initial retention, thus favoring adaptation to new dentures, especially in cases where neuromuscular dysfunctions may diminish the patient's ability to cope with adapting to existing motor patterns or learn new ones. However, a mucocompressive impression may cause higher residual ridge resorption, thus resulting in a retention decrease over time. A desirable combination would be a digital denture with a mucostatic intaglio surface obtained from intraoral scans and functional borders. A cast-free digital workflow for that is demonstrated in this technical report.

9.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38706266

RESUMEN

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Asunto(s)
Cerámica , Humanos , Cerámica/química , Cementos de Resina/química , Porcelana Dental/química , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija con Resina Consolidada , Circonio/química
10.
J Contemp Dent Pract ; 25(3): 241-244, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690697

RESUMEN

AIM: The current study was designed to assess the linear dimensional changes and adaptability of two heat-cured denture base resins using various cooling methods. MATERIALS AND METHODS: To prepare a total of 90 acrylic resin samples (45 acrylic resin samples for each material), four rectangular stainless-steel plates measuring 25 × 25 × 10 mm were fabricated. For both groups, the material was put into the mold at the dough stage. Group I - SR Triplex Hot Heat Cure acrylic; group II - DPI Heat Cure acrylic. Both groups used the same curing procedure. One of the following three techniques was used to cool the material (15 samples from each material) once the curing cycle was finished: (A) water bath, (b) quenching, and (C) air. A traveling microscope was used to measure the distance between the markings on the acrylic samples. The data was recorded and statistically analyzed. RESULTS: In SR Triplex Hot heat cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.242 ± 0.05), followed by the air technique (0.168 ± 0.11) and the least was found in the water bath technique (0.146 ± 0.01). In DPI Heat Cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.284 ± 0.09), followed by the air technique (0.172 ± 0.18) and the least was found in the water bath technique (0.158 ± 0.10). There was a statistically significant difference found between these three cooling techniques. On comparison of adaptability, the water bath technique, the marginal gap SR Triplex Hot was 0.012 ± 0.02 and DPI Heat Cure was 0.013 ± 0.02. In the quenching technique, the marginal gap SR Triplex Hot was 0.019 ± 0.04 and DPI Heat Cure was 0.016 ± 0.04. In the air technique, the marginal gap SR Triplex Hot was 0.017 ± 0.01 and DPI Heat Cure was 0.019 ± 0.01. CONCLUSION: The present study concluded that among the different cooling methods, the water bath technique had the least linear dimensional change, followed by the air and quenching techniques. When comparing the materials, DPI Heat Cure acrylic resin showed a greater linear dimensional change than SR Triplex Hot heat cure acrylic resin. CLINICAL SIGNIFICANCE: During polymerization, heat-cured acrylic resins experience dimensional changes. Shrinkage and expansion are dimensional changes that occur in heat-cured acrylic resins and have an impact on the occlusal relationship and denture fit. However, the denture base's material qualities and the different temperature variations it experiences during production may have an impact on this. How to cite this article: Kannaiyan K, Rathod A, Bhushan P, et al. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An In Vitro Study. J Contemp Dent Pract 2024;25(3):241-244.


Asunto(s)
Resinas Acrílicas , Bases para Dentadura , Calor , Ensayo de Materiales , Resinas Acrílicas/química , Técnicas In Vitro , Frío , Materiales Dentales/química
11.
J Adv Prosthodont ; 16(2): 91-104, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38694190

RESUMEN

PURPOSE: The objectives of the current study were to estimate the influence of self-reinforced hollow structures with a graded density on the dimensional accuracy, weight, and mechanical properties of Co-Cr objects printed with the direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS: Sixty-five dog-bone samples were manufactured to evaluate the dimensional accuracy of printing, weight, and tensile properties of DMLS printed Co-Cr. They were divided into Group 1 (control) (n = 5), Group 2, 3, and 4 with incorporated hollow structures based on (spherical, elliptical, and diamond) shapes; they were subdivided into subgroups (n = 5) according to the volumetric reduction (10%, 15%, 20% and 25%). Radiographic imaging and microscopic analysis of the fractographs were conducted to validate the created geometries; the dimensional accuracy, weight, yield tensile strength, and modulus of elasticity were calculated. The data were estimated by one-way ANOVA and Duncan's tests at P < .05. RESULTS: The accuracy test showed an insignificant difference in the x, y, z directions in all printed groups. The weight was significantly reduced proportionally to the reduced volume fraction. The yield strength and elastic modulus of the control group and Group 2 at 10% volume reduction were comparable and significantly higher than the other subgroups. CONCLUSION: The printing accuracy was not affected by the presence or type of the hollow geometry. The weight of Group 2 at 10% reduction was significantly lower than that of the control group. The yield strength and elastic modulus of the Group 2 at a 10% reduction showed means equivalent to the compact objects and were significantly higher than other subgroups.

12.
Future Microbiol ; 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700286

RESUMEN

Aim: To evaluate the biological and mechanical properties of an adhesive with nanostructured silver vanadate (AgVO3). Materials & methods: Specimens in poly(methyl methacrylate) (PMMA) were treated with Ultra Corega Cream (UCCA) denture adhesive with or without AgVO3. Biofilms of Candida albicans, Candida glabrata and Streptococcus mutans were grown and the viable cells counted. Fluorescence microscopy was used. The viability of the VERO cell and adhesive strength were evaluated. Results: All concentrations of AgVO3 reduced the biofilm formation and showed no cytotoxic effect. At 5 min and 24 h, UCCA with 5 and 10% AgVO3 showed better performance, respectively. Conclusion: AgVO3 promoted the antibiofilm activity of the adhesive, with a positive effect on the adhesive strength, and was biocompatible.


What is this summary about? Some people wear false teeth called dentures. They use a special glue to keep these false teeth in their mouths. It is important to clean dentures well and remove the glue every day. If the dentures get dirty, they can cause infections of the gums. Doctors and dentists can help, but sometimes medicines do not work well. This study checked to see whether adding a medicine that can kill bacteria into the glue could stop gum swelling and other illnesses, or make them better. What were the results? The glue containing the medicine killed microbes like fungi and bacteria. It also stuck things together well and was safe to use. What do the results mean? Using this special glue could help people with dentures to avoid illness.

13.
Comput Biol Med ; 175: 108550, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701590

RESUMEN

BACKGROUND AND OBJECTIVE: Complete denture is a common restorative treatment in dental patients and the design of the core components (major connector and retentive mesh) of complete denture metal base (CDMB) is the basis of successful restoration. However, the automated design process of CDMB has become a challenging task primarily due to the complexity of manual interaction, low personalization, and low design accuracy. METHODS: To solve the existing problems, we develop a computer-aided Segmentation Network-driven CDMB design framework, called CDMB-SegNet, to automatically generate personalized digital design boundaries for complete dentures of edentulous patients. Specifically, CDMB-SegNet consists of a novel upright-orientation adjustment module (UO-AM), a dental feature-driven segmentation network, and a specific boundary-optimization design module (BO-DM). UO-AM automatically identifies key points for locating spatial attitude of the three-dimensional dental model with arbitrary posture, while BO-DM can result in smoother and more personalized designs for complete denture. In addition, to achieve efficient and accurate feature extraction and segmentation of 3D edentulous models with irregular gingival tissues, the light-weight backbone network is also incorporated into CDMB-SegNet. RESULTS: Experimental results on a large clinical dataset showed that CDMB-SegNet can achieve superior performance over the state-of-the-art methods. Quantitative evaluation (major connector/retentive mesh) showed improved Accuracy (98.54 ± 0.58 %/97.73 ± 0.92 %) and IoU (87.42 ± 5.48 %/70.42 ± 7.95 %), and reduced Maximum Symmetric Surface Distance (4.54 ± 2.06 mm/4.62 ± 1.68 mm), Average Symmetric Surface Distance (1.45 ± 0.63mm/1.28 ± 0.54 mm), Roughness Rate (6.17 ± 1.40 %/6.80 ± 1.23 %) and Vertices Number (23.22 ± 1.85/43.15 ± 2.72). Moreover, CDMB-SegNet shortened the overall design time to around 4 min, which is one tenth of the comparison methods. CONCLUSIONS: CDMB-SegNet is the first intelligent neural network for automatic CDMB design driven by oral big data and dental features. The designed CDMB is able to couple with patient's personalized dental anatomical morphology, providing higher clinical applicability compared with the state-of-the-art methods.


Asunto(s)
Dentadura Completa , Humanos , Diseño de Dentadura/métodos , Redes Neurales de la Computación , Diseño Asistido por Computadora
14.
Quintessence Int ; 0(0): 0, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38619260

RESUMEN

OBJECTIVES: This systematic review compares the impact of ball and locator attachments on marginal bone loss in implant-retained overdentures in completely edentulous patients. METHOD AND MATERIALS: Following PRISMA guidelines, health science librarians completed literature searches from inception to March 17, 2023 in seven databases. There were 15,686 items exported to EndNote from Embase.com, CINAHL (EBSCO), Cochrane Library, Ovid MEDLINE-ALL, PubMed, Scopus, and Web of Science. Hand-searching added four more articles. After deduplication, 6756 items were screened for eligibility. Twenty-nine studies were assessed by full text, of which ten studies, involving 424 subjects, were included in the review. Risk of bias assessment was conducted using the Cochrane Risk of Bias tool and the Newcastle Ottawa Scale. A meta-analysis was performed to synthesize and analyze the collective data from the selected studies. RESULTS: The included studies used diverse methodologies, implant systems, and loading protocols. Most studies reported no significant difference in marginal bone loss between ball and locator attachments. The meta-analysis revealed high heterogeneity. CONCLUSION: The results of this systematic review suggest that ball and locator attachments exhibit similar performance in terms of marginal bone loss in implant-retained overdentures. However, the limited number, risk of bias, and heterogeneity of studies highlight the need for standardized research designs and larger sample sizes in future investigations to draw more definitive conclusions.

15.
J Hist Dent ; 72(1): 74-88, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38642384

RESUMEN

The modern theory of complete denture retention using suction was applied to wooden plate dentures in Japan from the first half of the 16th century, which is an astonishing achievement since it was clinically applied in North America and Europe in the latter half of the 19th century nearly 300 years later. Wooden dentures are unique to Japan resulting from skilled Japanese craftsmanship and are not found in other countries. We comprehensively reviewed reports on wooden plate dentures, analyzed 145 complete and partial dentures, and discussed their history. Japanese wooden plate dentures are mainly made of box wood, and artificial teeth are made of pagodite, ivory, and natural teeth. Small nails were driven into the molar region. Many existing dentures revealed attrition on the occlusal faces, thereby indicating that the wearers were able to masticate sufficiently. Wooden plate dentures have been used for 400 years in the early 20th century. Although Japanese wooden dentures have not been mentioned in the history of dentistry in Western literature, they comprise an important part of the history of denture development.


Asunto(s)
Dentadura Completa , Boca Edéntula , Humanos , Japón , Succión , Dentadura Parcial
16.
Cureus ; 16(3): e56938, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38665767

RESUMEN

While uncommon among adults, the act of inhaling a foreign object is a grave incident that might potentially endanger one's life or result in substantial repercussions. A 43-year-old patient with a history of asthma and epilepsy from infancy appeared with worsening respiratory distress and the presence of purulent secretions one week following an epileptic seizure. The chest X-rays and abdominal ultrasound revealed no anomalies. A bronchoscopy performed with local anesthesia enabled clear vision of the foreign object, and its removal was successfully executed, eliminating the need for a more invasive procedure. Bronchoscopy is crucial for both diagnosis and treatment, particularly in cases where there is a suspicion of inhalation of a foreign object that cannot be seen on X-rays. However, X-rays can still be useful for detecting radiopaque foreign objects or for identifying indirect symptoms of their existence.

17.
J Mech Behav Biomed Mater ; 155: 106556, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38676972

RESUMEN

This study assessed the mechanical properties and surface characteristics of dental prosthetic acrylic resin fabricated by 3D printing, comparing it with subtractive, pressing, and molding techniques. Bar-shaped specimens (N= 90; 65 × 10 × 3.3 mm; ISO:207951) were prepared and assigned into six groups: PRINT (3D printing vis stereolithography with PriZma 3D Bio Denture, Makertech Labs); SUB (subtractive manufacturing with Vipiblock Trilux, Vipi); PRESS Base (pressing using muffle with Thermo Vipi Wave, Vipi for base); PRESS Tooth (pressing with Onda-cryl, Clássico for tooth); MOLD Base (molding using addition silicone with Vipi Flash, Vipi for base); and MOLD Tooth (molding with Dencor, Clássico for tooth). Monotonic flexural strength (FS) and elastic modulus (E) were measured using a three-point bending approach (n= 5) on a universal testing machine at a crosshead speed of 5 mm/min. Fatigue testing (n= 10) followed similar geometry and settings, with a frequency of 2 Hz, initial stress level at 20 MPa, and stress increments of 5 MPa every 2,500 cycles. Surface roughness (n= 10) was assessed through profilometry, and fractographic and topographic analyses were conducted. Statistical analyses included One-Way ANOVA for monotonic FS, roughness, and E, along with Kaplan-Meier with Mantel-Cox post-hoc and Weibull analysis for fatigue strength. PRINT showed lower monotonic FS than the SUB and PRESS Tooth but comparable fatigue strength to these groups and superior to PRESS Base and MOLD (Base and Tooth) groups. All groups had similar Weibull moduli. Surface roughness of the PRINT group was comparable to most techniques but higher than the PRESS Tooth group. Fractographic analysis revealed fractures originating from surface defects under tensile stress, with SEM showing scratch patterns in all groups except PRINT, which had a more uniform surface. Despite its lower monotonic strength, 3D printed resin demonstrated comparable fatigue strength to subtractive and pressing methods and similar surface roughness to most methods, indicating its potential as a viable option for dental prosthesis.

18.
Artículo en Inglés | MEDLINE | ID: mdl-38652435

RESUMEN

The association of silver nanoparticles (AgNps) to sealant agent Palaseal® can be a promising alternative for complete denture wearers who may develop denture stomatitis (DS). The study aimed to evaluate the anti-Candida and biocompatible potential of silver nanoparticles synthesized by three routes associated with denture glaze to prevent and/or treat oral candidiasis. Surface acrylic resin specimens were treated with different associations of glaze with AgNps (VER+AgUV, VER+AgTurk and VER+AgGm). As controls, specimens were treated with glaze+nystatin (VER+Nyst), glaze only (VER) or submerged in PBS (PBS). Afterwards, Candida albicans biofilm was developed for 24 h, 15 d and 30 d. Subsequently, the biofilm was quantified by CFU/mL, XTT assay and confocal laser scanning microscopy. Fibroblasts were submitted to conditioned medium with the same associations for 24, 48 and 72 h and LIVE/DEAD® viability test was carried out. Regardless of the period, there was a significant reduction (p < 0.01) of viable fungal cells load, as well as inhibition of fungal metabolic activity, in specimens treated with glaze+AgNps associations, compared to VER and PBS. The anti-Candida effects of the associations were similar to the VER+Nyst group, with emphasis on VER+AgGm, which showed the highest percentage values of non-viable fungal cells maintained over time. The associations did not prove toxicity to fibroblasts. The AgNps exerted antimicrobial activity against C. albicans biofilms and are biocompatible. The most effective results were achieved with the association of glaze+silver nanoparticles synthesized by the green chemistry method (AgGm), proving to be an innovative alternative in the management of DS.

19.
J Prosthodont Res ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38644230

RESUMEN

PURPOSE: The purpose of this study is to compare the shear bond strength of ultraviolet (UV)-polymerized resin to 3D-printed denture materials, both with and without post-polymerization. Moreover, the effects of surface treatment and thermocycling on shear bond strength after post-polymerization were investigated. METHODS: Cylindrical 3D-printed denture bases and teeth specimens were prepared. The specimens are subjected to two tests. For Test 1, the specimens were bonded without any surface treatment or thermal stress for comparison with and without post-polymerization. In Test 2, specimens underwent five surface treatments: untreated (CON), ethyl acetate (EA), airborne particle abrasion (APA) with 50 µm (50-APA) and 110 µm alumina (110-APA), and tribochemical silica coating (TSC). A UV-polymerized resin was used for bonding. Half of the Test 2 specimens were thermocycled for 10,000 cycles. Shear bond strength was measured and analyzed using Kruskal-Wallis and Steel-Dwass tests (n = 8). RESULTS: In Test 1, post-polymerization significantly reduced shear bond strength of both 3D-printed denture materials (P < 0.05). No notable difference was observed between the denture teeth and the bases (P > 0.05). In Test 2, before thermocycling, the CON and EA groups exhibited low bond strengths, while the 50-APA, 110-APA, and TSC groups exhibited higher bond strengths. Thermocycling did not reduce bond strength in the latter groups, but significantly reduced bond strength in the EA group (P < 0.001). CONCLUSIONS: Post-polymerization can significantly reduce the shear bond strength of 3D-printed denture materials. Surface treatments, particularly APA and TSC, maintained bond strength even after thermocycling.

20.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(2): 345-351, 2024 Apr 18.
Artículo en Chino | MEDLINE | ID: mdl-38595256

RESUMEN

OBJECTIVE: To analyze the influence of forming direction on the surface characteristics, elastic modulus, bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction, and to provide scientific basis and guidance for the clinical application of oral denture base resin materials. METHODS: The 3D printing technology was used to print denture base resin samples. The shape and size of the samples referred to the current standard for testing conventional denture base materials. The samples used for physical performance testing were cylindrical (with a diameter of 15 mm and a thickness of 1 mm) and printed at different angles along the Z axis (0°, 45°, 90°). Scanning electron microscope was used to observe the microscopic topography of the different samples. The color stability of different samples was observed by color stabilizer. The surface roughness of the samples was analyzed by using surface roughness tester. The Vickers hardness was measured to analyze the hardness of the samples. The samples used for mechanical performance testing were rectangular (elastic modulus and bending strength: A length of 64 mm, a width of 10 mm, and a height of 3.3 mm; fracture toughness: A length of 39 mm, a width of 8 mm, and a height of 4 mm), divided into two groups: W group and H group. The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X, Y axis plane, while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X, Y axis plane. The forming angles of both groups were equally divided into 0°, 45°, and 90°. The elastic modulus, bending strength and fracture toughness of different samples were studied through universal mechanical testing machine. SPSS 22.0 software was used for statistical analysis. RESULTS: The microscopic topography and roughness of different samples were closely related to the printing direction, with significant differences between the 0°, 45°, and 90° specimens. The 0° specimens had the smoothest surface (roughness < 1 µm). The surface of the 45° specimen was the roughest (roughness>3 µm). The microhardness of the 0° sample was the best [(196.13±0.20) MPa], with a significant difference compared with the 90° sample [(186.62±4.81) MPa, P < 0.05]. The mechanical properties of different samples were also closely related to the printing direction. The elastic modulus, bending strength, and fracture toughness of the 45° samples in the W group were the highest compared with the other groups. The results of elastic modulus showed that in the H group, the 45° specimens had the highest elastic mo-dulus, which was significantly different from the 0° and 90° specimens (P < 0.05). The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens (P < 0.05). The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group. The bending strength of the 90° specimens in the W group was the smallest, and there was a significant difference between 90° and the 0° and 45° specimens (P < 0.05); And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group (P < 0.05). The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2, which was specified in the denture base standard. The 45° samples in the W group were the highest, with significant differences compared with the 0° and 90° samples (P < 0.05). And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2. And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group (P < 0.05). CONCLUSION: The 0° samples had relatively better physical properties. The 45° samples had the best mechanical properties. But the fracture toughness of specimens (H group and 90° samples of W group) did not yet meet clinical requirements. That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction. Only when the performance of the printed samples in all directions met the minimum requirements of the standard, they could be used in clinical practice.


Asunto(s)
Impresión Tridimensional , Prostodoncia , Ensayo de Materiales , Propiedades de Superficie , Resistencia Flexional , Bases para Dentadura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...