1.
Heliyon ; 10(14): e34569, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39082010

RESUMEN

Background: Efficient diagnosis of patients at high risk for invasive aspergillosis (IA) improves the outcome of the disease. Lateral flow assay (LFA) is a novel technology and assessing its diagnostic accuracy is of great significance in the clinical management of IA. Methods: A meta-analysis using case-control studies was performed to assess the diagnostic performance of LFA alone or galactomannan (GM) combined with LFA (GM-LFA) as screening tests for IA. The sensitivity, specificity, and summary receiver operating characteristic curves were constructed. Results: Nineteen studies with 2838 patients were included. The pooled effect sizes for different indicators included: sensitivity (77 % for LFA and 75 % for GM-LFA), specificity (88 % for LFA and 87 % for GM-LFA), positive likelihood ratio (6.65 for LFA and 12.02 for GM-LFA), negative likelihood ratio (0.26 for LFA and 0.27 for GM-LFA), and the diagnostic odds ratio (25.81 for LFA and 44.87 for GM-LFA). The area under the curve was 0.91 for LFA and 0.94 for GM-LFA with a cut-off value ≥ 0.5. Conclusion: The present meta-analysis suggested that LFA or GM-LFA at an optical density index (ODI) cutoff of ≥0.5 was a useful diagnostic tool for IA in patients. The results showed no significant differences in the accuracy of LFA alone and GM-LFA in diagnosing IA. In the clinical diagnosis and treatment of IA, LFA can be recommended if timely results are needed.

2.
J Clin Virol ; 174: 105706, 2024 10.
Artículo en Inglés | MEDLINE | ID: mdl-38908267

RESUMEN

Respiratory tract infections caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza viruses are persistent and critical. The Cobas Liat SARS-CoV-2 & influenza A/B assay (Multiplex Liat), the FDA-authorized point-of-care reverse transcriptase polymerase chain reaction (RT-PCR) assay, has a turnaround time of 20 min and high accuracy. This study evaluates the pooled performance of this assay to provide practical information. This meta-analysis was registered in PROSPERO (registration number: CRD42023467579). A systematic literature search was conducted within PubMed, Ovid-EMBASE, and the Cochrane Library for articles evaluating the accuracy of the Multiplex Liat assay through September 2023. A random-effects model was used to calculate the pooled diagnostic values with real-time RT-PCR (rRT-PCR) as a reference test. A total of 4,705 samples from eight studies were included in the primary meta-analysis. The overall pooled sensitivity and specificity of Multiplex Liat were 100.0 % (95 % confidence interval [CI] = 96.7 %-100.0 %) and 99.7 % (95 % CI = 98.7 %-99.9 %), respectively. The presence of variants of concern or in-house rRT-PCR assays as reference standards did not significantly affect the pooled diagnostic performance of the Multiplex Liat. When 5,333 samples from nine studies were assessed for sensitivity, the pooled sensitivity was 100.0 % (95 % CI = 85.8 %-100.0 %) without a significant difference. This meta-analysis demonstrates the usefulness of Multiplex Liat for the detection of SARS-CoV-2 based on pooled diagnostic values. These practical findings may facilitate appropriate settings for the diagnosis and management of patients with respiratory tract infections.


Asunto(s)
COVID-19 , Gripe Humana , Sensibilidad y Especificidad , Humanos , COVID-19/diagnóstico , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/métodos , Virus de la Influenza A/aislamiento & purificación , Virus de la Influenza A/genética , Virus de la Influenza B/aislamiento & purificación , Virus de la Influenza B/genética , Gripe Humana/diagnóstico , Gripe Humana/virología , Reacción en Cadena de la Polimerasa Multiplex/métodos , Pruebas en el Punto de Atención , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , SARS-CoV-2/genética , SARS-CoV-2/aislamiento & purificación
3.
J Neurooncol ; 162(1): 15-23, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36853489

RESUMEN

PURPSOSE: Cerebral radiation necrosis (RN) is often a delayed phenomenon occurring several months to years after the completion of radiation treatment. Differentiating RN from tumor recurrence presents a diagnostic challenge on standard MRI. To date, no evidence-based guidelines exist regarding imaging modalities best suited for this purpose. We aim to review the current literature and perform a diagnostic meta-analysis comparing various imaging modalities that have been studied to differentiate tumor recurrence and RN. METHODS: A systematic search adherent to PRISMA guidelines was performed using Scopus, PubMed/MEDLINE, and Embase. Pooled sensitivities and specificities were determined using a random-effects or fixed-effects proportional meta-analysis based on heterogeneity. Using diagnostic odds ratios, a diagnostic frequentist random-effects network meta-analysis was performed, and studies were ranked using P-score hierarchical ranking. RESULTS: The analysis included 127 studies with a total of 220 imaging datasets, including the following imaging modalities: MRI (n = 10), MR Spectroscopy (MRS) (n = 28), dynamic contrast-enhanced MRI (n = 7), dynamic susceptibility contrast MRI (n = 36), MR arterial spin labeling (n = 5), diffusion-weighted imaging (n = 13), diffusion tensor imaging (DTI) (n = 2), PET (n = 89), and single photon emission computed tomography (SPECT) (n = 30). MRS had the highest pooled sensitivity (90.7%). DTI had the highest pooled specificity (90.5%). Our hierarchical ranking ranked SPECT and MRS as most preferable, and MRI was ranked as least preferable. CONCLUSION: These findings suggest SPECT and MRS carry greater utility than standard MRI in distinguishing RN from tumor recurrence.


Asunto(s)
Imagen de Difusión Tensora , Recurrencia Local de Neoplasia , Humanos , Imagen por Resonancia Magnética/métodos , Necrosis/diagnóstico por imagen , Recurrencia Local de Neoplasia/diagnóstico por imagen , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único/métodos
4.
Endocr Pract ; 29(4): 254-259, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36649781

RESUMEN

OBJECTIVE: Previous studies have shown inconsistent results regarding the usefulness of prolactin adjustment in bilateral inferior petrosal sinus sampling (BIPSS) in the differential diagnosis of adrenocorticotropic hormone (ACTH)-dependent Cushing syndrome (CS). This meta-analysis compared the diagnostic accuracy of prolactin adjustment versus no adjustment in BIPSS. METHODS: This study searched the PubMed, Embase, Web of Science, Cochrane library, and WanFang databases for published data as of March 2022 on the use of prolactin adjustment in BIPSS to differentially diagnose ACTH-dependent CS. A Bayesian joint bivariate model was used in the head-to-head comparison of the diagnostic accuracy. RESULTS: This meta-analysis included a total of 10 studies with 300 patients. The combined sensitivity and specificity for BIPSS without prolactin adjustment were 94.47% (95% CI, 88.67%-98.44%) and 91.14% (95% CI, 57.17%-99.80%), respectively. The combined sensitivity and specificity after prolactin adjustment were 99.97% (95% CI, 99.03%-100.00%) and 80.69% (95% CI, 50.27%-97.82%), respectively. After the prolactin adjustment, the sensitivity of BIPSS to diagnose Cushing disease was improved with a statistically significant difference (difference in sensitivity, 5.39%; 95% CI, 1.37%-11.26%), whereas the decrease in specificity was without a statistically significant difference (difference in specificity, -9.20%; 95% CI, -42.02% to 26.61%). CONCLUSION: This meta-analysis indicated that prolactin adjustment in BIPSS might help to recognize Cushing disease among patient with ACTH-dependent CS. However, prolactin adjustment may not help identify ectopic ACTH syndrome in BIPSS.


Asunto(s)
Síndrome de Cushing , Hipersecreción de la Hormona Adrenocorticotrópica Pituitaria (HACT) , Humanos , Muestreo de Seno Petroso/métodos , Hipersecreción de la Hormona Adrenocorticotrópica Pituitaria (HACT)/diagnóstico , Síndrome de Cushing/diagnóstico , Prolactina , Teorema de Bayes , Diagnóstico Diferencial , Hormona Adrenocorticotrópica , Pruebas Diagnósticas de Rutina
5.
J Orthop Surg Res ; 17(1): 564, 2022 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-36566223

RESUMEN

BACKGROUND: Early and accurate detection of periprosthetic joint infection (PJI) after hip and/or knee arthroplasty remains challenging. This systematic review and meta-analysis of diagnostic test accuracy studies aimed to evaluate the diagnostic accuracy of serum and synovial fluid interleukin (IL)-6 in detecting PJI. METHODS: We searched 3 databases for studies through December 31, 2021, using medical sub-headings terms and keywords. Studies reported sensitivity and specificity of serum and synovial fluid IL-6 in detecting PJI were considered. We calculated the pooled sensitivity, specificity, positive and negative likelihood ratio, diagnostic odds ratio (DOR), and the area under the summary receiver operating characteristic curve (AUC) to evaluate the diagnostic accuracy of serum and synovial fluid IL-6. RESULTS: Thirty studies were included. The pooled sensitivity, specificity, positive and negative likelihood ratio, DOR, and AUC of serum IL-6 in detecting PJI were 0.76 (0.69-0.81), 0.88 (0.82-0.92), 6.2 (4.3-9.0), 0.28 (0.22-0.35), 22 (14-36), and 0.88 (0.85-0.91), respectively. However, synovial fluid IL-6 achieved a pooled sensitivity of 0.87 (0.75-0.93), specificity of 0.90 (0.85-0.93), positive and negative likelihood ratio of 8.5 (5.3-13.6) and 0.15 (0.08-0.29), DOR of 57 (21-156), and AUC of 0.94 (0.92-0.96), which were higher than serum IL-6. CONCLUSIONS: Synovial fluid IL-6 test may be a promising test for PJI after hip and/or knee arthroplasty. However, considering the limited volume of synovial fluid and invasive acquisition of synovial fluid IL-6, serum IL-6 test may be also considered.


Asunto(s)
Interleucina-6 , Infecciones Relacionadas con Prótesis , Líquido Sinovial , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Biomarcadores/análisis , Biomarcadores/sangre , Pruebas Diagnósticas de Rutina/normas , Interleucina-6/análisis , Interleucina-6/sangre , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/etiología , Sensibilidad y Especificidad , Líquido Sinovial/química
6.
J Gen Fam Med ; 23(6): 393-400, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36349209

RESUMEN

Background: Hepatojugular reflux is a cardiac physical examination with a long history of use in heart failure diagnosis across many clinical settings. However, the development of new diagnostic methods has thrown the clinical role of hepatojugular reflux into question. Our meta-analysis aimed to determine the diagnostic accuracy of hepatojugular reflux and assess its usefulness in diagnosing congestive heart failure among at-risk patients. Methods: This meta-analysis of studies reporting diagnostic hepatojugular reflux values of patients at risk for congestive heart failure followed PRISMA guidelines. We searched MEDLINE, EMBASE, Web of Science, CENTRAL, and Google Scholar for eligible studies from inception through February 1, 2021. After QUADAS-2 quality assessment, we conducted data synthesis using the random effects model and a hierarchical summary receiver operating characteristic model. As an additional analysis, we sorted the studies by clinical setting and performed synthesis again. We submitted our protocol to PROSPERO (International Prospective Register of Systematic Reviews; ID No. CRD42020215004). Results: The literature search provided 4121 studies for evaluation. Seven studies and their 5195 participants were deemed eligible for synthesis. Clinical diagnosis was the most frequent reference standard. Bivariate random-effects analysis found hepatojugular reflux sensitivity of 0.12, 95% confidence interval (CI) [0.07-0.19], and specificity of 0.96, 95% CI [0.95-0.97]. The DOR was 29.7, 95% CI [18.4-45.3]. The additional analysis of the emergency settings provided a sensitivity of 0.14, 95% CI [0.12-0.17] and specificity of 0.95, 95% CI [0.93-0.96]. Conclusions: Our meta-analysis suggests that hepatojugular reflux has practical value for diagnosis of congestive heart failure with high specificity.

7.
J Affect Disord ; 315: 148-155, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-35931230

RESUMEN

BACKGROUND: This study's objective was to assess the diagnostic properties of the Whooley questions in identifying depression among perinatal women according to previously published studies. We conducted a systematic review and meta-analysis of studies investigating the diagnostic accuracy of the Whooley questions in perinatal women. METHODS: Nine databases were searched in October 2021. All primary studies evaluated the diagnostic properties of the Whooley questions compared with a diagnostic gold standard in women during the perinatal period or, if not identified as being in the perinatal stage within the study, women between 20 weeks' gestation to 4 weeks post-delivery. A bivariate mixed-effects meta-analysis was performed to estimate pooled diagnostic properties and measure heterogeneity. Meta-regression was conducted to evaluate factors contributing to heterogeneity. RESULTS: Six studies were included in the review; five were used in the meta-analysis. The pooled sensitivity (95 % confidence interval) was 0.95 (0.81-0.99), pooled specificity was 0.60 (0.44-0.74), pooled positive likelihood ratio was 2.4 (1.6-3.4), pooled negative likelihood ratio was 0.09 (0.02-0.32), and pooled diagnostic odds ratio was 27 (7-106); heterogeneity was substantial (I2 = 0.90, 0.81-1.00). Participant age and setting (community vs. hospital) significantly contributed to heterogeneity. CONCLUSIONS: The Whooley questions have high sensitivity but moderate specificity for perinatal women. The Whooley questions are a short and acceptable tool for identifying depression in perinatal women. However, a potential risk exists of incorrectly identifying a high proportion of women as positive. Using the Whooley questions followed by a secondary case-finding tool could reduce the misdiagnosis risk.


Asunto(s)
Depresión Posparto , Depresión , Depresión/diagnóstico , Depresión Posparto/diagnóstico , Femenino , Humanos , Parto , Embarazo , Sensibilidad y Especificidad
8.
J Clin Virol ; 148: 105121, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35245882

RESUMEN

INTRODUCTION: Active SARS-CoV-2 infection is confirmed mainly through the detection of viral nucleic acid via the reverse transcriptase polymerase chain reaction (RT-PCR) technique. Methods to assess humoral responses contribute to the monitoring of the disease and confirmation of exposure to the virus. OBJECTIVE: To evaluate the accuracy of tests for IgM and IgG antibodies for SARS-CoV-2 infection confirmed by RT-PCR and utility as complementary data for immunosurveillance. METHODS: Literature research was performed by searching the terms "COVID-19", "COVID-19 diagnostic testing" and "test" in the databases MEDLINE, EMBASE, Cochrane Library, Web of Science and Cumulative Index to Nursing and Allied Health Literature to search for potentially eligible observational studies without language restrictions published up to September 2020. RESULTS: The pooled sensitivity and specificity, regardless of collection moment, was 80.0% (CI 95% 72.0-86.0) and 97.0% (CI 95% 94.0-98.0) for "IgM and/or IgG", respectively. Serology considering immunoglobulins M and G together had a high accuracy performance on "fifteenth day and after": sensitivity and specificity was 91.0% (CI 95% 85.0-94.0) and 98.0% (CI 95% 95.0-99.0) respectively, DOR 461 and AUC 0.98. CONCLUSION: This study shows that serology is a group of tests with high accuracy, mainly following the second week after infection.


Asunto(s)
COVID-19 , Anticuerpos Antivirales , COVID-19/diagnóstico , Humanos , Inmunoglobulina G , Inmunoglobulina M , SARS-CoV-2 , Sensibilidad y Especificidad
9.
J Orthop Surg Res ; 17(1): 99, 2022 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-35172830

RESUMEN

BACKGROUND: Periprosthetic joint infection (PJI) is a devastating complication after total hip arthroplasty (THA) or total knee arthroplasty (TKA). It is scarce and contradicting evidence supporting the use of serum D-dimer to diagnose PJI in revision THA and TKA. This systematic review and meta-analysis aimed to investigate the accuracy of D-dimer in the diagnosis of periprosthetic infections. METHODS: The PubMed, Embase, Web of Science were systematically searched from the inception dates to August 15, 2020. We included all diagnostic studies of D-dimer in the diagnosis of periprosthetic infections. The literature's quality was evaluated by the QUADAS-2 tool, and Stata16 and Revman5.3 software carried out the meta-analysis. RESULTS: Of 115 citations identified by the search strategy, 10 studies (comprising 1756 participants) met the inclusion criteria. The literature quality assessment results show that most of the literature is low-risk bias literature. The combined sensitivity of D-dimer in diagnosing periprosthetic infections was 0.81 (95% confidence interval [CI] 0.71-0.88), combined specificity was 0.74 (95% CI 0.61-0.84), combined positive likelihood ratio was 3.1 (95% CI 2.0-5.0), combined negative likelihood ratio 0.26 (95% CI 0.16-0.41), combined diagnosis odds ratio 12 (95% CI 5-27), area under the Summary Receiver Operator Characteristic Curve (SROC) is 0.85 (95% CI 0.81-0.88). The data are statistically significant. CONCLUSION: D-dimer has a high diagnostic value in diagnosing PJI and has clinical significance in diagnosing periprosthetic infection. In addition, there are relatively few studies on the threshold of D-dimer, different sampling types, different laboratory detection methods, and different races, so more prospective trials with large samples, multi-centers, and scientific design should be carried out in the future.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Productos de Degradación de Fibrina-Fibrinógeno/análisis , Infecciones Relacionadas con Prótesis/diagnóstico , Biomarcadores/sangre , Proteína C-Reactiva/análisis , Humanos , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/sangre , Sensibilidad y Especificidad
10.
Neuropsychiatr Dis Treat ; 17: 3415-3430, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34848962

RESUMEN

PURPOSE: Depression is a symptom commonly encountered in primary care; however, it is often not detected by doctors. Recently, disease diagnosis and treatment approaches have been attempted using smart devices. In this study, instrumental effectiveness was confirmed with the diagnostic meta-analysis of studies that demonstrated the diagnostic effectiveness of PHQ-9 for depression using mobile devices. PATIENTS AND METHODS: We found all published and unpublished studies through EMBASE, MEDLINE, MEDLINE In-Process, and PsychINFO up to March 26, 2021. We performed a meta-analysis by including 1099 subjects in four studies. We performed a diagnostic meta-analysis according to the PHQ-9 cut-off score and machine learning algorithm techniques. Quality assessment was conducted using the QUADAS-2 tool. Data on the sensitivity and specificity of the studies included in the meta-analysis were extracted in a standardized format. Bivariate and summary receiver operating characteristic (SROC) curve were constructed using the metandi, midas, metabias, and metareg functions of the Stata algorithm meta-analysis words. RESULTS: Using four studies out of the 5476 papers searched, a diagnostic meta-analysis of the PHQ-9 scores of 1099 people diagnosed with depression was performed. The pooled sensitivity and specificity were 0.797 (95% CI = 0.642-0.895) and 0.85 (95% CI = 0.780-0.900), respectively. The diagnostic odds ratio was 22.16 (95% CI = 7.273-67.499). Overall, a good balance was maintained, and no heterogeneity or publication bias was presented. CONCLUSION: Through various machine learning algorithm techniques, it was possible to confirm that PHQ-9 depression screening in mobiles is an effective diagnostic tool when integrated into a diagnostic meta-analysis.

11.
Reprod Biol Endocrinol ; 19(1): 177, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34852820

RESUMEN

BACKGROUND: We designed a meta-analysis to evaluate the clinical significance and efficacy of circulating noncoding RNAs (ncRNAs) in the early prediction of preeclampsia. METHODS: PubMed, Embase and the Cochrane Library were used to search for literature. The combined prediction performance was evaluated by calculating the area under the summary receiver operator characteristic (SROC) curve. The potential sources of heterogeneity were analysed by meta-regression analysis and subgroup analysis. All statistical analyses and mapping were performed by RevMan 5.3 and Stata 12.0. RESULTS: A total of 41 studies from 14 articles, including 557 preeclampsia patients and 842 controls, were included in our meta-analysis. All studies collected blood before onset. NcRNAs in blood performed relatively well in predicting preeclampsia. The combined sensitivity was 0.71, the specificity was 0.84, and the area under the SROC curve (AUC) was 0.86. Peripheral blood mononuclear cell (PBMC) samples showed the best diagnostic accuracy. The combined AUC was 0.93. Combined detection was better than single detection, and miRNA was better than circRNA. The heterogeneity of the study was determined by sample size, lncRNA characteristics, lncRNA source and race. CONCLUSION: Circulating ncRNAs can be valuable biomarkers used as candidates for noninvasive early predictive biomarkers of preeclampsia and have great clinical application prospects. The clinical value of ncRNAs needs to be tested by further multicentre, comprehensive and prospective studies, and the test criteria should be established.


Asunto(s)
Ácidos Nucleicos Libres de Células/sangre , Preeclampsia/diagnóstico , ARN Largo no Codificante/sangre , Biomarcadores/sangre , Femenino , Humanos , Preeclampsia/sangre , Embarazo , Sensibilidad y Especificidad
12.
EClinicalMedicine ; 31: 100669, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33392486

RESUMEN

BACKGROUND: Early diagnosis of tumor metastasis is crucial for clinical treatment. Artificial intelligence (AI) has shown great promise in the field of medicine. We therefore aimed to evaluate the diagnostic accuracy of AI algorithms in detecting tumor metastasis using medical radiology imaging. METHODS: We searched PubMed and Web of Science for studies published from January 1, 1997, to January 30, 2020. Studies evaluating an AI model for the diagnosis of tumor metastasis from medical images were included. We excluded studies that used histopathology images or medical wave-form data and those focused on the region segmentation of interest. Studies providing enough information to construct contingency tables were included in a meta-analysis. FINDINGS: We identified 2620 studies, of which 69 were included. Among them, 34 studies were included in a meta-analysis with a pooled sensitivity of 82% (95% CI 79-84%), specificity of 84% (82-87%) and AUC of 0·90 (0·87-0·92). Analysis for different AI algorithms showed a pooled sensitivity of 87% (83-90%) for machine learning and 86% (82-89%) for deep learning, and a pooled specificity of 89% (82-93%) for machine learning, and 87% (82-91%) for deep learning. INTERPRETATION: AI algorithms may be used for the diagnosis of tumor metastasis using medical radiology imaging with equivalent or even better performance to health-care professionals, in terms of sensitivity and specificity. At the same time, rigorous reporting standards with external validation and comparison to health-care professionals are urgently needed for AI application in the medical field. FUNDING: College students' innovative entrepreneurial training plan program .

13.
BMC Endocr Disord ; 20(1): 143, 2020 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-32943040

RESUMEN

BACKGROUND: Previous studies have shown inconsistent results about the usefulness of bilateral inferior petrosal sinus sampling (BIPSS) in differential diagnosis of adrenocorticotropic hormone (ACTH)-dependent Cushing syndrome. This meta-analysis evaluated the diagnostic value of BIPSS via the published literature. METHODS: This study searched PubMed, Embase, Web of Science, Cochrane library, and Wanfang database for published data on the use of BIPSS in Cushing syndrome differential diagnosis as of October 2019. Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and receiver operating characteristic (ROC) curves were calculated based on the relevant data. RESULTS: This meta-analysis included a total of 23 studies with 1642 patients. The calculated sensitivity, specificity, PLR, and NLR were 0.94 (95% confidence interval, CI: 0.91-0.96), 0.89 (95% CI: 0.79-0.95), 8.8 (95% CI: 4.3-17.9), and 0.07 (95% CI: 0.04-0.11), respectively. The pooled DOR and area under the ROC curve were 129 (95% CI: 48-345) and 0.97 (95% CI: 0.95-0.98), respectively. CONCLUSION: This meta-analysis indicated that BIPSS had high diagnostic value for detecting ACTH in patients with ACTH-dependent Cushing syndrome, and BIPSS should be used as an effective method to identify ACTH-secretion sources.


Asunto(s)
Síndrome de ACTH Ectópico/diagnóstico , Hormona Adrenocorticotrópica/sangre , Síndrome de Cushing/diagnóstico , Muestreo de Seno Petroso/métodos , Síndrome de ACTH Ectópico/sangre , Síndrome de Cushing/sangre , Bases de Datos Factuales , Diagnóstico Diferencial , Humanos
14.
Sleep Med Rev ; 54: 101355, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32750654

RESUMEN

The aim of this meta-analysis was to compare the pooled sensitivity and specificity of the Pediatric Sleep Questionnaire (PSQ), Obstructive Sleep Apnea Questionnaire (OSA-18), and pulse oximetry (PO) according to OSAS severity. Three electronic databases were searched for studies evaluating sensitivity and specificity of the three tools against the apnea-hypopnea index measured using overnight in-laboratory or in-home polysomnography in children and adolescents from inception until January 11, 2020. A random-effects bivariate model was used to estimate the summary sensitivity and specificity of the tools. We identified 39 studies involving 6131 clinical and community children (aged 2.9-16.7 y). The PSQ exhibited the highest sensitivity (74%) for detecting symptoms of mild pediatric OSAS. The PSQ and PO had comparable sensitivity in screening moderate and severe pediatric OSAS (0.82 and 0.89 vs 0.83 and 0.83, respectively). PO yielded superior specificity in detecting mild, moderate, and severe pediatric OSAS (86%, 75%, and 83%, respectively) than did the PSQ and OSA-18 (all p < 0.05). Age, percentage of girls, index test criteria, methodology quality, and sample size significantly moderated sensitivity and specificity. For early detection of pediatric OSAS, the combined use of PSQ and PO is recommended when polysomnography is not available. PROSPERO REGISTRATION NUMBER: CRD42018090571.


Asunto(s)
Tamizaje Masivo , Oximetría , Apnea Obstructiva del Sueño/diagnóstico , Encuestas y Cuestionarios/normas , Adolescente , Niño , Preescolar , Femenino , Humanos , Internacionalidad , Masculino , Metaanálisis como Asunto , Polisomnografía/instrumentación , Sensibilidad y Especificidad
15.
J Hosp Infect ; 104(3): 381-389, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31790743

RESUMEN

Recently, molecular assays have been demonstrated to be reliable for rapid detection of carbapenemase-producing Enterobacteriaceae (CPE) directly from positive blood cultures, reducing significantly the time for identification. Few studies have tested their performance on rectal swabs and no comprehensive conclusions have been reached regarding their utility for infection control management. Our aim was to review and assess the overall diagnostic test accuracy of polymerase chain reaction for the detection of CPE in rectal swabs. The electronic database PubMed was searched, up to October 1st, 2019, without language restriction or publication date restrictions. First, the concepts of the research questions were defined: 'carbapenemase-producing Enterobacteriaceae', 'molecular testing', 'test detection', and 'rectal screening'. Two reviewers independently screened studies, extracted data, and assessed quality using the QUADAS-2 instrument. Statistical analyses were carried out in Stata software using the bivariate model. In all, 143 articles were screened and 16 studies were included. Five (31%) of the studies were conducted in the context of a CPE outbreak; one study (6%) included patients pre-identified with CPE in clinical samples (blood or tracheal secretions), whereas the rest (63%) collected rectal swabs from patients considered at high risk of colonization. The molecular assays evaluated had a relatively good sensitivity of 0.95 (95% confidence interval (CI): 0.902-0.989), and an excellent specificity of 0.994 (95% CI: 0.965-1). Molecular techniques seem to be a useful, accurate diagnostic tool in screening for carriage of CPE in contact patients around a fortuitous discovery of a non-isolated hospitalized carrier patient.


Asunto(s)
Infecciones por Enterobacteriaceae/diagnóstico , Enterobacteriaceae/aislamiento & purificación , Recto/microbiología , beta-Lactamasas/metabolismo , Técnicas Bacteriológicas/métodos , Enterobacteriaceae/enzimología , Humanos , Tamizaje Masivo/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Factores de Tiempo
16.
BMC Endocr Disord ; 19(1): 56, 2019 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-31170960

RESUMEN

BACKGROUND: Thyrotoxicosis is often caused by destructive thyroiditis (DT) or Graves' disease (GD), and a prompt and accurate differential diagnosis for thyrotoxicosis is needed as management strategy differs. A meta-analysis of published literature was performed to evaluate the diagnostic accuracy for differentiating GD from DT patients by the measurement of mean peak systolic velocity of superior thyroid artery (STA-PSV) using ultrasonography. METHODS: The databases of Embase, Pubmed, Cochrane, Web of Science, Wanfang, and CNKI were retrieved without time limit to identify eligible studies. The statistical information and scientific quality were assessed and classified. The data were analyzed using Stata12.0 software. RESULTS: A total of 11 studies with 1052 cases only from Asia were included. Meta-analysis results showed the pooled sensitivity and pooled specificity of STA-PSV by ultrasonography were 0.86 (95% CI, 0.80-0.90) and 0.93 (95% CI, 0.86-0.97) in distinguishing GD from DT, respectively, with the AUC of 0.94 (95% CI, 0.92-0.96) . CONCLUSION: STA-PSV by ultrasonography is a useful diagnostic method in differentiating GD from DT. More studies from other countries are needed to further evaluate the accuracy of STA-PSV for the differential diagnosis of thyrotoxicosis.


Asunto(s)
Arterias/diagnóstico por imagen , Enfermedad de Graves/diagnóstico , Flujo Sanguíneo Regional/fisiología , Sístole , Glándula Tiroides/irrigación sanguínea , Tiroiditis/diagnóstico , Tirotoxicosis/diagnóstico , Velocidad del Flujo Sanguíneo , Diagnóstico Diferencial , Enfermedad de Graves/complicaciones , Enfermedad de Graves/diagnóstico por imagen , Humanos , Pronóstico , Glándula Tiroides/diagnóstico por imagen , Tiroiditis/complicaciones , Tiroiditis/diagnóstico por imagen , Tirotoxicosis/complicaciones , Tirotoxicosis/diagnóstico por imagen , Ultrasonografía Doppler
17.
Acta Radiol ; 60(5): 670-676, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30149749

RESUMEN

BACKGROUND: Patients with uterine cervical cancer suffer high mortality. Accurate detection of a residual tumor by magnetic resonance imaging (MRI) during and after directed brachytherapy (BCT) is crucial for the success of cancer treatment and is a significant predictor of patient survival. PURPOSE: To determine the diagnostic significance of MRI in detecting residual tumor tissue after BCT. MATERIAL AND METHODS: The Web of Knowledge, Cochrane Library, and PubMed were systematically searched (January 1997 to December 2016) for post-brachytherapy MRI studies that measured residual tumors in patients with uterine cervical cancer. All data were analyzed using the Meta-Disc 1.4 program. RESULTS: Four clinical studies consisting of 163 patients (147 of whom were included in the present analysis) who were diagnosed with uterine cervical cancer according to the International Federation of Gynecology and Obstetrics (FIGO) staging system were included in the study. All the patients received BCT and underwent MRI detection of residual tumors tissue. In studies where the accuracy of MRI detection was confirmed by histological tests or gynecological tests, the summary estimates of specificity, sensitivity, positive predictive value, negative predictive value, and accuracy were 88.5%, 83.5%, 53.5%, 97.1%, and 84.3%, respectively. CONCLUSION: MRI-directed BCT is commonly used for cervical cancer patients. Based on our investigation of four independent studies, MRI showed better prediction of positive results than negative results in patients with cervical cancer after BCT. However, more data on the greater numbers of patients are needed to establish the accuracy of MRI detection of cervical cancer after BCT.


Asunto(s)
Braquiterapia/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/radioterapia , Cuello del Útero/diagnóstico por imagen , Femenino , Humanos , Sensibilidad y Especificidad , Resultado del Tratamiento
18.
BMJ Open ; 7(9): e015247, 2017 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-28965089

RESUMEN

OBJECTIVES: To investigate whether an authorship effect is found that leads to better performance in studies conducted by the original developers of the Patient Health Questionnaire (PHQ-9) (allegiant studies). DESIGN: Systematic review with random effects bivariate diagnostic meta-analysis. Search strategies included electronic databases, examination of reference lists and forward citation searches. INCLUSION CRITERIA: Included studies provided sufficient data to calculate the diagnostic accuracy of the PHQ-9 against a gold standard diagnosis of major depression using the algorithm or the summed item scoring method at cut-off point 10. DATA EXTRACTION: Descriptive information, methodological quality criteria and 2×2 contingency tables. RESULTS: Seven allegiant and 20 independent studies reported the diagnostic performance of the PHQ-9 using the algorithm scoring method. Pooled diagnostic OR (DOR) for the allegiant group was 64.40, and 15.05 for non-allegiant studies group. The allegiance status was a significant predictor of DOR variation (p<0.0001).Five allegiant studies and 26 non-allegiant studies reported the performance of the PHQ-9 at recommended cut-off point of 10. Pooled DOR for the allegiant group was 49.31, and 24.96 for the non-allegiant studies. The allegiance status was a significant predictor of DOR variation (p=0.015).Some potential alternative explanations for the observed authorship effect including differences in study characteristics and quality were found, although it is not clear how some of them account for the observed differences. CONCLUSIONS: Allegiant studies reported better performance of the PHQ-9. Allegiance status was predictive of variation in the DOR. Based on the observed differences between independent and non-independent studies, we were unable to conclude or exclude that allegiance effects are present in studies examining the diagnostic performance of the PHQ-9. This study highlights the need for future meta-analyses of diagnostic validation studies of psychological measures to evaluate the impact of researcher allegiance in the primary studies.


Asunto(s)
Autoria , Sesgo , Cuestionario de Salud del Paciente/normas , Investigadores , Algoritmos , Humanos , Proyectos de Investigación
19.
Stat Med ; 36(19): 3039-3058, 2017 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-28474394

RESUMEN

In a bivariate meta-analysis, the number of diagnostic studies involved is often very low so that frequentist methods may result in problems. Using Bayesian inference is particularly attractive as informative priors that add a small amount of information can stabilise the analysis without overwhelming the data. However, Bayesian analysis is often computationally demanding and the selection of the prior for the covariance matrix of the bivariate structure is crucial with little data. The integrated nested Laplace approximations method provides an efficient solution to the computational issues by avoiding any sampling, but the important question of priors remain. We explore the penalised complexity (PC) prior framework for specifying informative priors for the variance parameters and the correlation parameter. PC priors facilitate model interpretation and hyperparameter specification as expert knowledge can be incorporated intuitively. We conduct a simulation study to compare the properties and behaviour of differently defined PC priors to currently used priors in the field. The simulation study shows that the PC prior seems beneficial for the variance parameters. The use of PC priors for the correlation parameter results in more precise estimates when specified in a sensible neighbourhood around the truth. To investigate the usage of PC priors in practice, we reanalyse a meta-analysis using the telomerase marker for the diagnosis of bladder cancer and compare the results with those obtained by other commonly used modelling approaches. Copyright © 2017 John Wiley & Sons, Ltd.


Asunto(s)
Teorema de Bayes , Pruebas Diagnósticas de Rutina , Metaanálisis como Asunto , Sesgo , Biometría/métodos , Simulación por Computador , Humanos , Sensibilidad y Especificidad , Telómero , Neoplasias de la Vejiga Urinaria/diagnóstico , Neoplasias de la Vejiga Urinaria/genética
20.
Sleep Med Rev ; 36: 57-70, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-27919588

RESUMEN

Obstructive sleep apnea (OSA) is a highly prevalent sleep disorder; however, it remains underdiagnosed and undertreated. Although screening tools such as the Berlin questionnaire (BQ), STOP-BANG questionnaire (SBQ), STOP questionnaire (STOP), and Epworth sleepiness scale (ESS) are widely used for OSA, the findings regarding their diagnostic accuracy are controversial. Therefore, this meta-analysis investigated and compared the summary sensitivity, specificity, and diagnostic odds ratio (DOR) among the BQ, SBQ, STOP, and ESS according to the severity of OSA. Electronic databases, namely the Embase, PubMed, PsycINFO, ProQuest dissertations and theses A&I databases, and China knowledge resource integrated database, were searched from their inception to July 15, 2016. We included studies examining the sensitivity and specificity of the BQ, SBQ, STOP, and ESS against the apnea-hypopnea index (AHI) or respiratory disturbance index (RDI). The revised quality assessment of diagnostic accuracy studies was used to evaluate the methodological quality of studies. A random-effects bivariate model was used to estimate the summary sensitivity, specificity, and DOR of the tools. We identified 108 studies including a total of 47 989 participants. The summary estimates were calculated for the BQ, SBQ, STOP, and ESS in detecting mild (AHI/RDI ≥ 5 events/h), moderate (AHI/RDI ≥ 15 events/h), and severe OSA (AHI/RDI ≥ 30 events/h). The performance levels of the BQ, SBQ, STOP, and ESS in detecting OSA of various severity levels are outlined as follows: for mild OSA, the pooled sensitivity levels were 76%, 88%, 87%, and 54%; pooled specificity levels were 59%, 42%, 42%, and 65%; and pooled DORs were 4.30, 5.13, 4.85, and 2.18, respectively. For moderate OSA, the pooled sensitivity levels were 77%, 90%, 89%, and 47%; pooled specificity levels were 44%, 36%, 32%, and 621%; and pooled DORs were 2.68, 5.05, 3.71, and 1.45, respectively. For severe OSA, the pooled sensitivity levels were 84%, 93%, 90%, and 58%; pooled specificity levels were 38%, 35%, 28%, and 60%; and pooled DORs were 3.10, 6.51, 3.37, and 2.10, respectively. Therefore, for mild, moderate, and severe OSA, the pooled sensitivity and DOR of the SBQ were significantly higher than those of other screening tools (P < .05); however, the specificity of the SBQ was lower than that of the ESS (P < .05). Moreover, age, sex, body mass index, study sample size, study populations, presence of comorbidities, PSG or portable monitoring performance, and risk of bias in the domains of the index test and reference standard were significant moderators of sensitivity and specificity (P < .05). Compared with the BQ, STOP, and ESS, the SBQ is a more accurate tool for detecting mild, moderate, and severe OSA. Sleep specialists should use the SBQ to conduct patient interviews for the early diagnosis of OSA in clinical settings, particularly in resource-poor countries and sleep clinics where PSG is unavailable.


Asunto(s)
Sensibilidad y Especificidad , Apnea Obstructiva del Sueño/diagnóstico , Encuestas y Cuestionarios , Berlin , Humanos
SELECCIÓN DE REFERENCIAS