Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur Heart J Case Rep ; 8(8): ytae366, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39108997

RESUMEN

Background: Severe aortic paravalvular leaks (PVLs) after surgical mechanical aortic valve replacement (AVR) represent a high risk for congestive heart failure, haemolysis, and infective endocarditis. This is the first reported case of distal radial artery (DRA) access for severe mechanical aortic PVL closure with a sequential double vascular plug guided by computed tomography angiography (CTA), transoesophageal echocardiography (TOE), and 3D TOE in an acute setting. Case summary: A 51-year-old male presented with significant mixed aortic valve disease. Aortic valve replacement was performed (Slimline Bicarbon A-25 mm) according to guidelines. Four and 16 days later, a re-exploration was carried out due to pericardial effusion. Four months after discharge from rehabilitation, the patient was readmitted due to worsening dyspnoea on exertion and then at rest. Transthoracic echocardiography, TOE, and consequently, CTA, revealed severe PVL, following which the procedure of transcatheter PVL closure was chosen, with a preference for DRA access. After a CTA scan analysis and angiographic, TOE, and 3D TOE visualization of the leak, a 14/5 mm and a 10/5 mm vascular plug (AVPIII) were deployed to achieve good results. A 9-month clinical, echocardiographic, and CTA follow-up revealed good long-term results. Discussion: For transcatheter PVL closure, CTA is helpful for not only vascular access planning, but also a visualization of the magnitude of the leak, location, and device planning. This case report demonstrates that the distal radial approach is feasible in patients with severe mechanical aortic valve PVL retrograde transcatheter closure. DRA access could possibly represent less bleeding and vascular access site complications when compared with femoral access and has some potential advantages over regular radial access.

2.
World Neurosurg ; 183: e920-e927, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38237802

RESUMEN

BACKGROUND: Transcarotid artery revascularization (TCAR) has emerged as an alternative to carotid artery stenting (CAS). TCAR demonstrated its superiority by avoiding femoral artery puncture and establishing proximal protection without crossing the stenotic lesion. In the TCAR era, we focused on the possibility of a trans-distal radial approach (DRA). A balloon-guide catheter was navigated via DRA to establish proximal protection before lesion crossing. The forearm subcutaneous vein was used as the flow-reversal circuit. METHODS: Six internal carotid artery stenosis patients underwent CAS using "the forearm flow reversal technique." Every procedure was performed under continuous flow reversal from the common carotid artery to the forearm cephalic vein. RESULTS: Successful revascularization was achieved without ischemic or access-site complications. The distal radial artery was patent at discharge in all cases. CONCLUSIONS: Trans-distal radial CAS with forearm flow reversal is a feasible and less invasive technical option.


Asunto(s)
Estenosis Carotídea , Procedimientos Endovasculares , Accidente Cerebrovascular , Humanos , Estenosis Carotídea/cirugía , Estenosis Carotídea/complicaciones , Antebrazo/cirugía , Arteria Radial/cirugía , Factores de Riesgo , Stents/efectos adversos , Arteria Carótida Común , Resultado del Tratamiento , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Procedimientos Endovasculares/efectos adversos
3.
J Invasive Cardiol ; 35(11)2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37992334

RESUMEN

OBJECTIVES: Previous studies show that the distal transradial approach (dTRA) is safe and effective for coronary angiography and percutaneous coronary intervention. However, the effect of dTRA on radiation exposure in the catheterization laboratory has not been characterized. The authors analyzed the available literature to compare the radiation exposure associated with dTRA vs the traditional radial approach (TRA). METHODS: A systematic review and meta-analysis of the scientific literature was conducted by using relevant terms to search the PubMed, Embase, and Cochrane Library databases from their inception until October 13, 2022, to identify randomized controlled trials (RCTs) comparing dTRA with TRA. The primary outcome was radiation exposure reported as fluoroscopy time, air kerma, or kerma-dose product. The standard mean difference (SMD) and its 95% confidence interval were used to summarize continuous variables. Random effect and meta-regression also were used for analyses. RESULTS: Among 484 studies identified, 7 were RCTs, with a total of 3427 patients (1712 dTRA, 1715 TRA). No difference was found between dTRA and TRA in radiation exposure quantified as fluoroscopy time (SMD -0.10 [-0.36, 0.15], P=.43) or air kerma (SMD -0.31 [-0.74, 0.13], P=.17). The overall estimate favored lower kerma-area product in the TRA (SMD 0.19 [0.08, 0.30], P=.0006). Meta-regression showed no correlation between fluoroscopy time and year of publication. CONCLUSIONS: Compared with TRA, dTRA was associated with significantly greater radiation exposure per the kerma-area product during interventional cardiology procedures, with no differences in fluoroscopy time and air kerma.


Asunto(s)
Intervención Coronaria Percutánea , Exposición a la Radiación , Humanos , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Arteria Radial
4.
Am J Cardiol ; 203: 325-331, 2023 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-37517127

RESUMEN

Nitroglycerin dilates the radial artery and prevents spasm, which increases the success rate of sheath cannulation through the conventional transradial approach. However, the effects of nitroglycerin on distal radial approach (DRA) procedures are not known. The aim of this study is to elucidate whether a transdermal nitroglycerin patch improves the rate of successful DRA cannulation. A total of 92 patients scheduled for coronary angiography by means of DRA randomly received (1:1) a transdermal nitroglycerin patch preintegrated with the covering material or only the covering material on their upper arm on the side of the puncture. The diameter of the distal radial artery was evaluated with ultrasound at baseline and after application. DRA procedures were performed in a double-blind fashion. The primary outcome was the rate of successful palpation-guided distal radial artery cannulation with the first puncture. The nitroglycerin group had larger distal radial artery diameter after patch application than that of the no-treatment group (mean, 3.21 mm vs 2.71 mm, p <0.001), but not at baseline (mean, 2.64 mm vs 2.64 mm, p = 0.965).The nitroglycerin group had a significantly higher success rate of DRA cannulation with the first puncture than that of the no-treatment group (59% vs 24%, p = 0.001; odds ratio 4.5, 95% confidence interval 1.9 to 11.0). The nitroglycerin group required fewer punctures than did the no-treatment group (median, 1 vs 3, p = 0.019). There were no significant differences in the occurrence of hypotension between the 2 groups. No patients experienced radial artery occlusion. In conclusion, transdermal nitroglycerin patch application safely facilitates DRA cannulation. Trial Registration: Japan Registry of Clinical Trials, https://jrct.niph.go.jp/ (identifier: jRCTs051210128).


Asunto(s)
Nitroglicerina , Vasodilatadores , Humanos , Nitroglicerina/uso terapéutico , Vasodilatadores/uso terapéutico , Angiografía Coronaria/métodos , Cateterismo , Ultrasonografía , Arteria Radial
5.
Front Cardiovasc Med ; 10: 1007147, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36937930

RESUMEN

Background: The distal radial approach (DRA) for coronary catheterization is increasingly being used worldwide yet the optimal medication regimen to prevent radial artery spasm (RAS), an important factor for the success of the procedure, remains unclear. The aim of this study is to examine the effectiveness of medication for preventing RAS via the DRA. Methods: This was a prospective, comparative randomized study including 400 patients who underwent coronary catheterization via DRA in single center by three experienced DRA operators. Patients were randomized to either nitroglycerin (NTG) injection (N = 200) or NTG plus verapamil (N = 200) to compare the effectiveness and safety of these regimens. Results: There were no differences between the groups in the changes in radial artery diameter at most spastic area (0.34 ± 0.20 in the NTG group, 0.35 ± 0.20 in the NTG plus verapamil group; P = 0.73). There was no difference between the groups in the ratio of patients without arm pain during the procedure (95.0% in the NTG group, 93.5% in the NTG plus verapamil group; P = 0.67). However, there was a greater reduction in diastolic blood pressure in the NTG plus verapamil group (-8.3 ± 7.9 mmHg) than in the NTG group (-6.6 ± 7.6 mmHg) (P = 0.03). Conclusion: Intra-arterial injection of NTG as a single agent is effective and safe in the prevention of RAS during coronary catheterization via the DRA compared with a cocktail regimen of NTG plus verapamil. Clinical trial registration: https://cris.nih.go.kr, identifier KCT0005177.

6.
J Clin Monit Comput ; 37(3): 867-872, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36550346

RESUMEN

The arterial pressure line (A-line) is primarily inserted through the radial artery. However, accidental removal due to joint movement can be problematic in the intensive care unit (ICU). This study aimed to evaluate the safety and effectiveness of A-line insertion in the ICU through the distal radial approach (DRA), which is used in cardiac catheterization. This single-center, prospective, comparative study included 200 patients (≥ 20 years) who were brought to our hospital for emergency care and required A-line insertion. Patients were quasi-randomized to the traditional radial approach (TRA) or DRA. Data were recorded at the time of A-line insertion, administration, and removal. We evaluated the vessel diameter, number of punctures, success of the procedure, presence of complications, such as infection during management, and time taken for hemostasis after catheter removal. The primary endpoint was the accidental removal rate. Due to incomplete information, data were collected for 193 patients (96 TRA and 97 DRA). Successful procedures were observed in 95 of the 96 patients with TRA and 94 of the 97 patients with DRA. Guidewire use during insertion was significantly more common in the DRA group (P < 0.01) and post-puncture splint fixation was significantly more common in the TRA group (P < 0.01). Accidental removal, the primary endpoint, was observed in 10 patients with TRAs and 11 patients with DRAs, with no significant difference between the two groups (P > 0.99). DRA is as safe and effective as the TRA, suggesting that it is useful as a new A-line insertion site.


Asunto(s)
Presión Arterial , Cateterismo Periférico , Humanos , Estudios Prospectivos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Arteria Radial , Unidades de Cuidados Intensivos , Resultado del Tratamiento
7.
Heart Vessels ; 38(2): 147-156, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35974254

RESUMEN

The distal radial approach (DRA) has been proposed as an alternative approach for coronary angiography (CAG) and percutaneous coronary intervention (PCI); however, the predictors of DRA failure and puncture site complications are unclear. Among 7153 consecutive patients undergoing CAG or PCI between November 2018 and January 2021, 3610 patients undergoing CAG or PCI with DRA were analyzed. The primary endpoint of this study was the procedural success, and the secondary endpoint of this study was puncture site complications during procedure. Puncture site complications during procedure were defined as a composite of major bleeding, minor bleeding, arteriovenous fistula, pseudoaneurysm, and neuropathy. The DRA success rate and the puncture site complication rate were 90.4% and 7.7%, respectively. The predictors of DRA failure were low body weight and dual antiplatelet therapy; those of DRA success were PCI and ultrasonography-guided DRA; those of puncture site complications during procedure were low body weight, peripheral arterial disease, dual antiplatelet therapy, anticoagulant therapy, and PCI; and that of no puncture site complications were previous PCI and ultrasonography-guided DRA. The negative predictors of DRA success with no puncture site complication during procedure were low body weight and dual antiplatelet therapy. The positive predictor of DRA success with no puncture site complication during procedure was ultrasonography-guided DRA. We identified the predictors of DRA failure and puncture site complications during procedure in patients undergoing CAG and PCI with DRA. Ultrasonography-guided DRA was associated with a high DRA success rate and a low puncture site complication rate in patients undergoing CAG or PCI with DRA.


Asunto(s)
Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Hemorragia/etiología , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Arteria Radial , Peso Corporal , Resultado del Tratamiento
8.
Cardiovasc Revasc Med ; 43: 43-48, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35597718

RESUMEN

BACKGROUND: The distal radial approach (DRA) is a novel catheter cannulation technique to access the distal radial artery for coronary angiography (CAG). It is associated with less occurrence of puncture site occlusion than the conventional transradial approach. However, cannulation failure occasionally occurs due to difficulty in puncturing the smaller distal radial artery. Nitroglycerin is expected to improve the rate of successful DRA via its vasodilative and vasospasm-preventive effects. METHODS: The DRA in CAG using transdermal NitroGlycerin patch (DRANG) study is a single-center, double-arm, parallel-assignment, double-blinded, randomized, controlled trial. Eligible patients with angina pectoris who are scheduled to receive CAG via DRA at the National Cerebral and Cardiovascular Center will be enrolled and allocated to the nitroglycerin group (n = 46) or the no-treatment group (n = 46). The nitroglycerin group will receive a transdermal nitroglycerin patch pre-integrated with a covering material that completely conceals the patch on their upper arm on the puncture side. The no-treatment group will receive only the covering material. Applications are performed 2-8 h before puncture while the patient wears an eye mask. Physicians who are blinded to the allocation and have similar experience with DRA puncture will perform DRA using the Seldinger technique with a 22-gauge needle. The primary outcome is the rate of successful palpation-guided distal radial artery cannulation with the first puncture. The secondary outcomes are the rate of successful distal radial artery cannulation, number of punctures, procedure time, use of ultrasound guidance, diameter of the distal radial artery and changes before and after patch application, and occurrence of arterial vasospasm, occlusion, or hypotension. CONCLUSIONS: This study will allow us to determine the impact of a transdermal nitroglycerin patch on the rate of successful DRA and validate its effectiveness as a DRA pretreatment. TRIAL REGISTRATION: jRCTs051210128.


Asunto(s)
Nitroglicerina , Arteria Radial , Angiografía Coronaria/métodos , Estudios de Factibilidad , Humanos , Nitroglicerina/efectos adversos , Punciones , Arteria Radial/diagnóstico por imagen , Ensayos Clínicos Controlados Aleatorios como Asunto
9.
J Cardiol Cases ; 25(1): 52-54, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35024071

RESUMEN

Conventional radial access (cRA) for percutaneous coronary intervention (PCI) has become the current standard due to low bleeding complications, although recently, distal radial access (dRA) has attracted attention as an alternative. Here, the usefulness of dRA is shown in a case in whom neither side could be used for cRA. The patient was a woman in her 70 s diagnosed with unstable angina pectoris at another hospital. Although ad hoc PCI was attempted via her right forearm radial artery, her hemodynamics deteriorated and the procedure was abandoned. After an intra-aortic balloon pumping device was inserted via the left femoral approach and hemostasis was established with a dedicated device, the patient was transferred to our hospital. Her right radial artery was being used for hemostasis and her left radial artery was poorly palpable. Because her right distal radial artery was palpable, access via that location was attempted after confirming sufficient blood vessel diameter and blood flow by ultrasound. A 6Fr sheath was inserted and PCI was safely accomplished. Hemostasis on dRA was completed without complications using a hemostasis device. Thus, dRA may be an option as an alternative access site in an emergency. .

10.
J Vasc Access ; 23(4): 538-542, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33749367

RESUMEN

BACKGROUND: Arterial catheter (A-line) is essential for managing severely ill patients, and the radial artery is the most common insertion site in the intensive care unit (ICU). However, many accidental removals occur because the insertion site of A-line in the traditional radial approach (TRA) overlaps with the joint flexion. Recent reports have shown no significant difference in the complication rates between coronarography using the distal radial approach (DRA) and that using TRA. However, to date, no report has examined accidental removals of DRA in the ICU. This study aimed to retrospectively evaluate the safety of the DRA A-line in ICU management. METHODS: This retrospective, descriptive, and observational study enrolled patients who underwent A-line insertion using the DRA at the authors' facility, which is a university hospital with approximately 1100 beds, from January 1, 2019 to August 31, 2019. The participants' clinical data were extracted from their medical records. The primary outcome was the number of accidental removals. RESULTS: The study included 20 patients with a median age of 70 (interquartile range (IQR): 58.5-77) years: 10 patients with traumas, 6 with cerebral hemorrhages, 2 with gastrointestinal perforations, and 2 with other diagnoses. The number of punctures was 1 in 15 patients, 2 in 4 patients, and 3 in 1 patient. Only 1 patient required ultrasound guidance, whereas 12 patients required the use of guidewires. The median duration after insertion was 3 (IQR 2.5-5.5) days. Accidental removal was noted in only one patient. No other complications were observed during the period from insertion to removal. CONCLUSIONS: DRA may be a safe option for insertion of a new A-line in the ICU.


Asunto(s)
Cateterismo Periférico , Arteria Radial , Cateterismo Periférico/efectos adversos , Humanos , Unidades de Cuidados Intensivos , Proyectos Piloto , Arteria Radial/diagnóstico por imagen , Arteria Radial/cirugía , Estudios Retrospectivos
11.
J Clin Med ; 10(10)2021 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-34069701

RESUMEN

Recently, the left distal radial approach (DRA) for percutaneous coronary intervention (PCI) has been shown to be a feasible option, but there are limited data regarding the feasibility of performing bifurcation PCI via the left DRA. Therefore, this study aimed to describe our experience with the contemporary left DRA to perform PCI of bifurcation lesions. Between December 2017 and December 2019, we identified 106 patients treated with bifurcation PCI via the left DRA. We evaluated the success rate of PCI, access-site complications including major bleeding requiring surgery or transfusion, hematoma, distal and forearm radial artery occlusion, and 30-day mortality. Eleven patients (10.4%) treated with left main bifurcation and true bifurcations accounted for 39.6% of cases, with the left anterior descending artery/diagonal branch being the most frequent bifurcation site (57.5%, 61/106). PCI was performed using a 6-French guiding catheter in 101 (95.3%) cases. Successful PCI for bifurcation lesions via the left DRA was achieved in all 106 patients without access-site cross-over. There was no major bleeding, distal and forearm radial artery occlusion, forearm hematoma, or mortality at 30 days. The left DRA is a safe and feasible alternative access site for bifurcation PCI in selected patients.

13.
Surg Neurol Int ; 11: 400, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33274113

RESUMEN

BACKGROUND: Major advances in the endovascular treatment of cerebral aneurysms have reduced the incidence of intra- and postprocedural complications. The length of stay after treatment for incidental aneurysms remains between early next-day discharge and 2 days. We hypothesized that discharging patients the same day would not be associated with any increase in the rate of postdischarge adverse events. METHODS: We retrospectively reviewed the charts of patients who underwent an elective coiling procedure between 2015 and 2020 at three centers and were discharged from hospital on the same day as the procedure. Patients were clinically evaluated 6 h, 1 week, and 6 months after the procedure, with repeat cerebral angiography performed 1 year after the procedure. RESULTS: Eleven eligible patients underwent outpatient treatment of 12 aneurysms treated through the wrist. No complications were identified within 1 week of the procedure. Clinical evaluation 6 months after treatment also failed to reveal any complication associated with the procedure. Only one of the seven patients who underwent 1 year angiography required retreatment. CONCLUSION: It is possible to safely perform coiled embolization of cerebral aneurysms in select outpatients with unruptured cerebral aneurysms.

14.
Surg Neurol Int ; 11: 248, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32905334

RESUMEN

BACKGROUND: The transfemoral approach (TFA) has been the standard in neuroradiology over the years. However, the transradial approach (TRA) and its variants offer several benefits over the TFA. METHODS: Review of the literature about TRA and its variations. We present our results for different neurointerventional procedures at our institution between January 2018 and December 2019. RESULTS: We wrote an educational review describing anatomical and technical aspects, advantages, and complications of this approach. In the past year we increased the percentage of neurointerventional procedures performed through radial or ulnar arteries. CONCLUSION: There are clearly proven benefits of employing a wrist approach in patients for neurointerventional procedures and its utilization should especially be considered on a daily basis.

16.
Interv Cardiol Clin ; 9(1): 75-86, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31733743

RESUMEN

Trans-radial approach (TRA) has been used in cardiac and peripheral interventional radiology practices for decades, because of safety and patient comfort. There is interest in TRA in the cerebrovascular field, with potential to replicate benefits over trans-femoral approach. TRA is technically more challenging and has a learning curve, which hinders its use as the first-line approach; however, as more neuro-interventionalists embrace TRA, techniques are being optimized simultaneously for supra-aortic vessel catheterization. This article describes advantages, patient selection, conventional and distal radial access, and detailed techniques of trans-radial catheterization for diagnostic angiography, as well as cerebrovascular interventions and its current limitations.


Asunto(s)
Angiografía Cerebral/métodos , Arteria Radial , Cateterismo/métodos , Humanos , Selección de Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA