RESUMEN
Central hypothyroidism (CH) is characterized by decreased thyroid hormone production due to insufficient stimulation of an otherwise normal thyroid gland by TSH. In patients with established hypothalamic-pituitary disease, a low FT4 concentration is considered highly specific, although poorly sensitive, for the diagnosis of CH. That would be comparable to diagnosing primary hypothyroidism in patients at risk only when serum FT4 concentrations are below the reference range, missing all patients with subclinical primary hypothyroidism and preventing proper therapy in patients in which thyroxine replacement is clearly beneficial. Cardiac time intervals, especially the isovolumic contraction time (ICT), have been considered the gold standard of peripheral thyroid hormone action. Using Doppler echocardiography, we have previously shown a very high proportion of prolonged ICT in patients with hypothalamic-pituitary disease and serum FT4 levels indistinguishable from controls. As ICT decreased/normalized after thyroxine-induced increases in FT4 concentrations within the normal reference range, prolonged ICT was considered a bona fide diagnostic biomarker of subclinical CH. Those findings challenge the usual interpretation that FT4 concentrations in the mid-reference range exclude hypothyroidism in patients with hypothalamic-pituitary disease. Rather, subclinical central hypothyroidism, a state analogous to subclinical primary hypothyroidism, seems to be frequent in patients with hypothalamic-pituitary disease and normal FT4 levels. They also challenge the notion that thyroid function is usually the least or the last affected in acquired hypopituitarism. The relevance of Doppler echocardiography to correctly diagnose and monitor replacement therapy in both clinical and subclinical forms of CH should improve quality of life and decrease cardiovascular risk, as already demonstrated in patients with clinical and subclinical primary hypothyroidism.
Asunto(s)
Enfermedades Hipotalámicas , Hipotiroidismo , Humanos , Enfermedades Hipotalámicas/diagnóstico , Enfermedades de la Hipófisis/diagnóstico , Tiroxina/uso terapéutico , Tiroxina/sangreRESUMEN
OBJECTIVES: A systematic review of the literature was conducted to analyze the current evidence on low-flow, low-gradient severe aortic stenosis. This analysis aimed to differentiate between subgroups of patients with reduced and preserved left ventricular ejection fraction (LVEF). METHODS: After conducting a systematic literature review, 35 observational studies were included. Out of these, 28 were prospective and 7 retrospective. The studies that included a mortality risk stratification of low-flow, low-gradient aortic stenosis (LF- LG AS) with both preserved and reduced LVEF were reviewed. RESULTS: The importance of considering multiple clinical and echocardiographic variables in diagnostic evaluation and therapeutic decision-making was highlighted. CONCLUSIONS: LF- LG AS, in any of its subgroups, is a common and challenging valve lesion. A careful assessment of severity and, in specific scenarios, a thorough reclassification is important. More high-quality studies are required to more precisely define the classification and prognosis of this entity.
Asunto(s)
Estenosis de la Válvula Aórtica , Volumen Sistólico , Función Ventricular Izquierda , Humanos , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/complicaciones , Ecocardiografía/métodos , Pronóstico , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiologíaRESUMEN
ABSTRACT: The objective of the present study was to evaluate clinical, cardiorespiratory, and Doppler echocardiographic changes in rabbits sedated with midazolam and morphine combined with or without dexmedetomidine. This study was a blinded, randomized, controlled experiment that included 16 adult male New Zealand rabbits weighing 3.1 ± 0.3 kg. The animals were sedated using one of the following protocols: 1 mg/kg midazolam and 2 mg/kg morphine (MIDA, n = 8), or 25 mg/kg dexmedetomidine, 2 mg/kg morphine and 1 mg/kg midazolam (DEX, n = 8). Sedation latency, duration of the sedation and recovery period, sedation scores, heart rate (HR), respiratory rate (f), peripheral oxygen saturation (SpO2), systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), and recta temperature were recorded, and Doppler echocardiography was performed. Latency periods were 7.3±1.6 min in the DEX group and 10.9 ± 5.0 min in the MIDA group (P = 0.112). Sedation duration was 122.4±14 min in the DEX group and 71.2 ± 32 min in the MIDA group (P = 0.005), whereas recovery time was 35.7±17.7 min in the DEX group and 32.5 ± 25.3 min in the MIDA group (P = 0.743). The sedation scores for the DEX group were significantly higher than those for the MIDA group throughout the monitoring period. Reductions in HR, SAP, MAP, and DAP values were observed in both groups relative to baseline values, and were significantly lower in the DEX group compared to the MIDA group. Minimal Doppler echocardiographic changes were observed. Dexmedetomidine used in combination with midazolam and morphine incremented the quality and duration of sedation in rabbits. Both protocols elicited cardiorespiratory changes that were well-tolerated, with minimal changes in myocardial function.
RESUMO: O objetivo do presente estudo foi avaliar alterações clínicas, cardiorrespiratórias e ecodopplercardiográficas, bem como o nível de sedação em coelhos sedados com midazolam e morfina combinadas, ou não, com dexmedetomidina. O design do estudo foi experimental controlado randomizado cego, com 16 coelhos adultos machos Nova Zelândia, pesando 3,1 ± 0,3 Kg. Os animais foram sedados aleatoriamente com um dos seguintes tratamentos: MIDA (n = 8): 1 mg/kg de midazolam e 2 mg/kg de morfina; DEX (n = 8) 25 mcg/kg de dexmedetomidina, 2 mg/kg de morfina e 1 mg/kg de midazolam; Latência, sedação e períodos de recuperação, escores de sedação, FC, f, SpO2, PAS, PAM, PAD, ToC, foram mensurados e ecoDopplercardiografia foi realizada. Os períodos de latência foram 7.3 ± 1.6 minutos no grupo DEX e 10.9 ± 5.0 minutos no grupo MIDA (P = 0,112). A duração da sedação foi de 122.4 ± 14 minutos no grupo DEX e 71.2 ± 32 minutos no grupo MIDA (P = 0,005). Os tempos totais de recuperação foram de 35.7 ± 17.7 minutos no grupo DEX e 32.5 ± 25.3 minutos no MIDA (P = 0,743). Os escores de sedação obtidos do grupo DEX foram estatisticamente superiores aos do grupo MIDA durante todas as observações (de 5 a 40 minutos). A redução dos valores de FC, PAS, PAM e PAD foi observada em ambos os grupos, em relação ao momento baseline, e foram significativamente menores no grupo DEX quando comparado ao MIDA. Alterações ecodopplercardiográficas mínimas foram observadas ambos os grupos. A adição de dexmedetomidina à associação midazolam/morfina aumentou o nível, a qualidade e a duração do protocolo sedativo. Ambos os protocolos causaram alterações cardiorrespiratórias bem toleradas em animais normais e com mínimas alterações na função miocárdica.
RESUMEN
We demonstrated an endovascular technique excluding an ascending aorta pseudoaneurysm using an aortic extension. A 32-year-old woman, 3 years after lung transplantation with extracorporeal membrane oxygenation presented with an ascending aortic pseudoaneurysm. Vascular surgery was consulted after open repair was deemed high risk. An aortic extension stent graft was placed in a hybrid operating room with the aid of intraoperative transesophageal echocardiography. Ascending aorta pseudoaneurysms are complex and life-threatening complications. Traditional repair involves high surgical and anesthetic risks whereas endovascular treatment is technically feasible.
RESUMEN
Diastolic dysfunction (DD) is routinely evaluated in echocardiography to support diagnosis, prognostication, and management of heart failure, a condition highly prevalent in elderly patients. Clinical guidelines were published in 2009, and updated in 2016, pursuing to standardize and improve DD categorization. We aimed to assess the concordance of DD between these two documents in an elderly population and to investigate how left ventricular structural abnormalities (LVSA) impact the reclassification. To evaluate this we analyzed the 308 consecutive transthoracic echocardiograms in patients older than 60 years (70.4 ± 7.7 years-old, 59% women) that fulfilled the inclusion criteria out of the 1438 echocardiograms performed in a tertiary hospital. We found that the prevalence of DD was lower according to the 2016 criteria (64% vs. 91%; p < 0.001), with 207 (67.2%) patients changing category, indicating poor agreement between the guidelines (kappa = 0.21). There were 188 (61%) patients with LVSA, which drove most of the reclassifications in 2016 Grade I DD cases. The prevalence of elevated filling pressures by Doppler halved in this elderly population using the updated recommendations (20.9% vs. 39.2%; p < 0.001). In conclusion the prevalence of DD was lower applying the 2016 guidelines, with a poor agreement with 2009 guidelines in all DD grades. The role of LVSA in reclassifications was particularly evident in Grade I DD, while Doppler parameters drove reclassifications among the more severe grades. If not properly addressed, these discrepancies may undermine the reliance on DD as a diagnostic and prognostic tool, particularly in an elderly population at a higher risk of heart failure.
Asunto(s)
Cardiomiopatías , Cardiopatías Congénitas , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Femenino , Anciano , Persona de Mediana Edad , Masculino , Función Ventricular Izquierda , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/epidemiología , Valor Predictivo de las Pruebas , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/epidemiología , DiástoleRESUMEN
La artritis reumatoide es una enfermedad progresiva, con manifestaciones clásicas y tempranas como es la afectación de las articulaciones pequeñas de las manos y los tobillos. Se realizó una revisión bibliográfica de los documentos publicados entre 2017 y 2022. Se realizó una lectura preliminar de 37 artículos que cumplían con los criterios de inclusión, y finalmente se seleccionaron 23 artículos, de los cuales se tomó el contenido de mayor importancia. La ecografía es una técnica fiable y más sensible que la exploración clínica en el estudio de la enfermedad músculo-esquelética, pues permite una exploración multiplanar y dinámica, lo que resulta en un diagnóstico más exacto. La técnica Doppler constituye un complemento útil en el seguimiento de estos pacientes. Esta enfermedad es recurrente en las consultas de Reumatología, por tanto, en su valoración inicial, la utilidad de los medios diagnósticos, especialmente la ecografía, tiene gran importancia.
Rheumatoid arthritis is a progressive disease, with classic and early manifestations such as involvement of the small joints of the hands and ankles. We conducted a bibliographic review of the documents published between 2017 and 2022. A preliminary reading of 37 articles that met the inclusion criteria was carried out, and 23 articles were finally selected, from which the most important content was taken. Ultrasound is a more sensitive and reliable technique than clinical examination for the study of musculoskeletal disease, since it allows a multiplanar and dynamic examination, which results in a more accurate diagnosis. Doppler technique is a useful complement in the follow-up of these patients. This disease is recurrent in Rheumatology consultations, that's why in its initial assessment, the usefulness of diagnostic means, especially ultrasound, is of great importance.
Asunto(s)
Artritis Reumatoide , Reumatología , Ecocardiografía DopplerRESUMEN
BACKGROUND: Doppler echocardiographic (echo) assessment of residual mitral regurgitation (MR) after transcatheter edge-to-edge repair (TEER) is challenging and often subjective. This study aimed to evaluate the accuracy and feasibility of standardized quantitative echo methods for assessment of MR severity after MitraClip repair by comparing measurements against a reference MR severity obtained from patient-specific in silico models. METHODS: Post-procedure hemodynamics were simulated under five different MitraClip configurations in previously validated patient-specific in silico models for the treatment of functional MR. The residual regurgitant volume was calculated as in clinical practice using four quantitative virtual echo methods: pulsed Doppler, volumetric, proximal isovelocity surface area (PISA) and vena contracta area (VCA). Multiple permutations were performed for each method. Virtual echo MR results were evaluated against reference MR values directly extracted from the 5 patient-specific in silico models. RESULTS: The echo methods with the greatest accuracy were the three-dimensional (3D) volumetric method (r = 0.957, bias -0.8 ± 1.2 ml, p = 0.01), the 3D VCA method wherein velocity time integrals were evaluated for each jet assessed (r = 0.919, bias -1.5 ± 1.7 ml, p = 0.03), and the 3D PISA method integrating surface areas throughout systole (r = 0.98, bias -2.0 ± 0.9 ml, p = 0.003). The pulsed Doppler and 2D volumetric methods had technical limitations that may result in a high underestimation or overestimation of the MR severity after TEER. In the case of multiple regurgitant jets, a more accurate MR assessment was obtained when all significant jets were evaluated. CONCLUSIONS: Clinically, the 3D volumetric, 3D VCA and 3D PISA methods gave the most accurate MR quantification after TEER. Three-dimensional echo technologies harbor the potential of becoming the non-invasive imaging tool of choice for MR quantification after complex transcatheter mitral interventions.
Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Simulación por Computador , Ecocardiografía Doppler en Color , Hemodinámica , Humanos , Reproducibilidad de los Resultados , Índice de Severidad de la EnfermedadRESUMEN
Abstract Objective: To evaluate cardiac function and structural changes in children of diabetic mothers in the fetal and neonatal period using Doppler-echocardiographic data. Method: A prospective, descriptive observational study conducted in a private and tertiary care service for high-risk pregnant women. It included 48 children of mothers with gestational diabetes mellitus (GDM) considered clinically compensated during pregnancy, with a single fetus and absence of malformations. Myocardial thickness, shortening fraction, left ventricular (LVMPI) and right ventricular (RVMPI) myocardial performance index, and mitral and tricuspid valve E/A ratio were evaluated in 96 echocardiographic exams with Doppler. Results: The hypertrophic cardiomyopathy was 29% vs 6% p = 0.006 in the prenatal and postnatal periods respectively. The shortening fraction was 0% vs 6% p = 0.242 in the fetuses and newborns respectively. The myocardial performance index of the right ventricle was 12% vs 54% p ≤ 0.001, and on the left ventricle 27% vs 60% p = 0.001 in the prenatal and postnatal periods respectively. The ratio of mitral valve E/A waves was 6% vs 50% p ≤ 0.001 and the ratio of tricuspid valve E/A waves was 0% vs 27% p 0.001 in the fetuses and newborns respectively. Conclusion: A decrease in the rate of myocardial hypertrophy and changes in cardiac function parameters were observed in the fetal and neonatal periods.
Asunto(s)
Humanos , Femenino , Embarazo , Recién Nacido , Niño , Diabetes Gestacional , Cardiomiopatías , Estudios Prospectivos , Ultrasonografía Prenatal , Edad Gestacional , Corazón Fetal/diagnóstico por imagen , MadresRESUMEN
OBJECTIVES: To evaluate the accuracy of predicted prosthesis-patient mismatch (PPM) regarding actual PPM measured postoperatively. To assess the association between PPM and prosthetic valve dysfunction. METHODS: Retrospective cohort study including adult patients after aortic valve replacement surgery with a biological prosthesis. Predicted PPM status was determined using mean reference effective orifice area indexed to total body surface (iEOA), without considering reference standard deviations. Postoperative PPM status was determined by measuring iEOA within the first 60 postoperative days. Prosthetic valve dysfunction was defined as thrombosis, pannus, valve degeneration, and/or disruption. RESULTS: 205 patients were enrolled between January 2003 and June 2017: predicted PPM was absent in 52 patients (25.4%), moderate in 137 patients (66.8%), and severe in 16 patients (7.8%). After surgery, the actual postoperative iEOA was measured: 53 (25.9%) did not have PPM, 73 had moderate PPM (35.6%), and 79 had severe PPM (38.5%). Predicted PPM identified the presence of hemodynamically significant actual postoperative PPM (OR = 2.56; 95%CI 1.30-5.05; P = .006), though not its degree of severity. Prosthetic valve dysfunction was more frequent among patients with hemodynamically significant PPM (53.9% vs. 11.3%; P < .001), compared to those without PPM. The association between PPM and prosthetic valve dysfunction was maintained after adjusting for gender, age, and ever-smoking (OR = 9.03; P < .001). The incidence of thrombosis or pannus was also nonsignificantly higher in patients with moderate or severe PPM. CONCLUSIONS: Predicted PPM identifies the presence, possibly not the severity, of actual postoperative PPM. Moderate or severe PPM is associated with prosthetic valve dysfunction. Actual postoperative prosthesis-patient mismatch measured within 60 postoperative days showed a distinctive hemodynamic profile and presented a stronger association with prosthetic valve dysfunction than predicted prosthesis-patient mismatch. A. Echocardiographic follow-up in patients according to the actual postoperative PPM measured within 60 postoperative days. B. Prediction of prosthetic valve dysfunction based on preoperative predicted PPM or on actual postoperative PPM within 60 postoperative days. PPM: prosthesis-patient mismatch. OR: Odds ratio.
Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del TratamientoRESUMEN
RESUMEN La ventana aortopulmonar es una malformación cardiaca congénita poco frecuente que se encuentra entre el 0,2% y 0,6% de todas las cardiopatías congénitas. Consiste en una comunicación entre la aorta ascendente y el tronco de la arteria pulmonar en presencia de dos arterias con dos válvulas semilunares. Se presenta el caso de un lactante de 6 meses con 5,860 kg remitido al servicio de cardiología infantil por dificultad respiratoria y escasa ganancia ponderal. Entre los métodos diagnósticos se realiza la ecocardiografía doppler color requiriendo posteriormente complementar dicho método con cateterismo cardiaco y posterior resolución quirúrgica.
ABSTRACT Aortopulmonary window is a rare congenital heart malformation that is found in between 0.2% and 0.6% of all congenital heart disease. It consists of a communication between the ascending aorta and the trunk of the pulmonary artery in the presence of two arteries with two semilunar valves. We present the case of a 6-month-old infant weighing 5,860 kg referred to the pediatric cardiology service due to respiratory distress and low weight gain. As part of the diagnostic workup, color Doppler echocardiography was performed, along with subsequent cardiac catheterization and surgical resolution.
RESUMEN
BACKGROUND: Upper airway obstruction may cause pulmonary hypertension in childhood. In this study we aimed to identify a possible correlation of systolic pulmonary arterial pressure (SPAP), using Doppler echocardiography, with nasal patency (NP), as measured by rhinomanometry, in mouth-breathing (MB) children with allergic rhinitis (AR) and adenotonsillar hypertrophy (ATH). METHODS: In this cross-sectional study we evaluated 183 patients, from 2 to 12 years of age, at an MB referral clinic in Brazil, from December 2013 to 2017. We allocated patients to 4 etiology groups: group 1, 60 MBs with ATH; group 2, 47 MBs with AR; group 3, 43 MBs with both ATH and AR; and group 4, 33 nasal breathing control subjects. The ratio of total nasal inspiratory flow (assessed by active anterior rhinomanometry) and expected inspiratory flow adjusted for height determined the percent NP (%NP). RESULTS: The median %NP was higher in controls than in the MB groups (controls, 114% [79-147%]; ATH: 65% [5-116%]; AR: 57% [23-144%]; ATH and AR: 64% [3-120%]; p < 0.001). Median SPAP was higher in the MB groups than in controls (SPAP: ATH, 26.0 [20.0-35.0] mmHg; AR, 26.0 [22.0-32.0] mmHg; ATH and AR, 26.30 [20.0-34.0] mmHg; control, 22.0 [16.0-30.0] mmHg; p < 0.001). SPAP showed a negative association with %NP (Spearman's rho = -0.24; p < 0.001). CONCLUSION: Reduced nasal airflow in MB children showed a correlation with higher levels of systolic pulmonary arterial pressure. The AR and ATH groups were similar in nasal obstruction severity and systolic pulmonary arterial pressure level distribution.
Asunto(s)
Obstrucción Nasal , Rinitis Alérgica , Presión Arterial , Niño , Estudios Transversales , Humanos , Hipertrofia , Boca , Obstrucción Nasal/diagnóstico por imagenRESUMEN
OBJECTIVE: To evaluate cardiac function and structural changes in children of diabetic mothers in the fetal and neonatal period using Doppler-echocardiographic data. METHOD: A prospective, descriptive observational study conducted in a private and tertiary care service for high-risk pregnant women. It included 48 children of mothers with gestational diabetes mellitus (GDM) considered clinically compensated during pregnancy, with a single fetus and absence of malformations. Myocardial thickness, shortening fraction, left ventricular (LVMPI) and right ventricular (RVMPI) myocardial performance index, and mitral and tricuspid valve E/A ratio were evaluated in 96 echocardiographic exams with Doppler. RESULTS: The hypertrophic cardiomyopathy was 29% vs 6% pâ¯=â¯0.006 in the prenatal and postnatal periods respectively. The shortening fraction was 0% vs 6% pâ¯=â¯0.242 in the fetuses and newborns respectively. The myocardial performance index of the right ventricle was 12% vs 54% pâ¯≤â¯0.001, and on the left ventricle 27% vs 60% pâ¯=â¯0.001 in the prenatal and postnatal periods respectively. The ratio of mitral valve E/A waves was 6% vs 50% pâ¯≤â¯0.001 and the ratio of tricuspid valve E/A waves was 0% vs 27% pâ¯≤â¯0.001 in the fetuses and newborns respectively. CONCLUSION: A decrease in the rate of myocardial hypertrophy and changes in cardiac function parameters were observed in the fetal and neonatal periods.
Asunto(s)
Cardiomiopatías , Diabetes Gestacional , Niño , Femenino , Corazón Fetal/diagnóstico por imagen , Edad Gestacional , Humanos , Recién Nacido , Madres , Embarazo , Estudios Prospectivos , Ultrasonografía PrenatalRESUMEN
BACKGROUND: Strain Rate Imaging (SRI) is one of the most used techniques to study left atrial (LA) and diastolic function. Its availability in low-income countries is diminished since it requires additional expensive software, among other limitations. In contrast, Tissue Doppler Imaging (TDI) is widely available and easy to use. We hypothesize TDI could detect changes in LA and diastolic function associated with age similarly to SRI. The aim of this study is to evaluate the effects of age on LA and diastolic function assessed by LA lateral wall TDI online by spectral pulse, and to compare them with age-related variations of LA SRI and other parameters of diastolic function in a population of healthy adults. MATERIALS AND METHODS: Ninety-one healthy adults were prospectively evaluated. In apical four - chamber view the LA lateral wall was divided in three portions. Peak velocities of basal and mid portions were measured with TDI online by spectral pulse and with SRI by speckle tracking. A first positive wave (S'la and SRS) and two negative waves (E'la and SRE, and A'la and SRA respectively) were obtained. E'la/A'la ratio and SRE/SRA ratio were analyzed. The distribution of the variables by age subgroups was described and analyzed. Correlation analyses were performed. RESULTS: The median age was 42 years old and 54.9% were female. E'la/A'la showed a negative good correlation with age. E'la/A'la and SRE/SRA ratios changed from > 1 to < 1 in the age group of 41-50 years old, while this occurred in the group of 51-60 years old for the E/A ratio. Lateral and septal mitral annulus E´ showed decrease with age and prolongation of E-wave deceleration time was observed in the age group over 61 years old. CONCLUSION: Normal valuesââ according to age group of TDI of the LA lateral wall were obtained. Age-related changes in LA and diastolic function could be detected as early with TDI as with SRI. Future studies are required to explore if this method could be used to address in part LA or diastolic function in other populations with established cardiovascular disease or at risk of presenting it, which could be useful in low-income settings, where SRI is not available.
Asunto(s)
Ecocardiografía Doppler en Color , Voluntarios Sanos , Atrios Cardíacos/diagnóstico por imagen , Adulto , Factores de Edad , Diástole , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Estudios ProspectivosRESUMEN
Resumen: Las cardiopatías congénitas son la tercera causa de malformaciones congénitas y una de las principales responsables de la mortalidad en periodo neonatal en el mundo; se originan a partir de alteraciones en el desarrollo embrionario. La incidencia es variable; en Colombia, se estima que afectan del 2 al 3 % de los recién nacidos vivos. En 2015, 20,8 % de los niños menores de cinco años afectados con cardiopatías congénitas fallecieron a causa de estas alteraciones. El presente es un estudio descriptivo y retrospectivo. Se incluyeron los datos de 252 historias clínicas de pacientes con diagnóstico de cardiopatía congénita entre los años 2010 y 2016, el 56 % de la población encontrada fue de sexo femenino. Predominaron las cardiopatías congénitas no cianosantes (87 %). La mayor prevalencia fue el ductus arterioso permeable (35,3 %). La ecocardiografía Doppler se utilizó en 98,4 % de los casos; con respecto al manejo, el 47,2 % de los pacientes estuvieron en seguimiento, siendo este más común que las alternativas médicas o quirúrgicas. En conclusión, el ductus arterioso permeable, la comunicación interventricular y la comunicación interatrial son las cardiopatías no ciano-santes más frecuentes en la población estudiada y se asocian a hipertensión pulmonar que ameritan mayor seguimiento. La tetralogía de Fallot fue la cardiopatía congénita cianosante más común.
Abstract: Congenital heart defects are the third cause of congenital malformations and one of the main causes of mortality in the neonatal period in the world; they originate from alterations in embryonic development. The incidence is variable; in Colombia, it is estimated that they affect 2 to 3% of live newborns. In 2015, 20.8% of children under the age of five affected with congenital heart defects died from these disorders. This is a descriptive and retrospective study. Data of 252 clinical records of patients diagnosed with congenital heart defect between 2010 and 2016 were included, showing that 56% of this population were female. Acyanotic Congenital Heart Diseases predominated (87%). The highest prevalence was patent ductus arteriosus (35.3%). Doppler echocardiography was used in 98.4% of cases; regarding management, 47.2% of patients were in follow-up, this being more common than medical or surgical alternatives. In conclusion patent ductus arteriosus, ventricular septal defect and interatrial septal defect are the most frequent acyanotic heart diseases in the population under study and they are associated with pulmonary hypertension that require higher follow-up. Tetralogy of Fallot was the most common cyanotic congenital heart disease.
Resumo: As cardiopatias congênitas são a terceira causa de malformações congênitas e uma das principais responsáveis pela mortalidade no período neonatal no mundo. São originadas a partir de alterações no desenvolvimento embrionário. A incidência é variável; na Colômbia, é estimado que afetam de 2 a 3 % dos recém-nascidos vivos. Em 2015, 20,8 % das crianças menores de cinco anos afetadas com cardiopatias congênitas faleceram por causa dessas alterações. Este estudo é descritivo e retrospectivo. Foram incluídos dados de 252 prontuários de pacientes com diagnóstico de cardiopatia congênita entre 2010 e 2016, 56 % da população encontrada foi do sexo feminino. Predominaram as cardiopatias congênitas não cianóticas (87 %). A maior persistência foi o dueto arterioso permeável (35,3 %). A ecocardiografìa Doppler foi utilizada em 98,4 % dos casos; quanto ao manejo, 47,2 % dos pacientes estiveram em seguimento, o que foi mais comum do que as alternativas médicas ou cirúrgicas. Em conclusão, o ducto arterioso permeável, a comunicação interventricular e a comunicação interatrial são as cardiopatias não cianóticas mais frequentes na população estudada e são associadas com a hipertensão pulmonar que merecem maior seguimento. A tetralogia de Fallot foi a cardiopatia congènita cianòtica mais comum.
Asunto(s)
Humanos , Cardiopatías Congénitas , Ecocardiografía Doppler , Conducto Arterioso Permeable , Defectos de los Tabiques CardíacosRESUMEN
Introducción: A partir de los años 50, la presentación clínica clásica de la endocarditis infecciosa ha variado. Debido al uso de antibióticos, drogas ilícitas, catéteres venosos, etc., las manifestaciones tradicionales no son frecuentes. Objetivo: Presentar un caso con endocarditis infecciosa y comentar las manifestaciones embolígenas, así como las medidas preventivas con las nuevas técnicas. Caso clínico: Enfermo con insuficiencia renal crónica, diabético, hipertenso, con catéter venoso central, que presentó, después de una sección de hemodiálisis; escalofríos intensos, fiebre de 39,5 0C, cefalea intensa, toma del estado general, dolor torácico intenso punzante, tos, expectoración con sangre roja rutilante, disnea, soplo regurgitante holosistólico. Se le realizó ecocardiograma dópler que muestra múltiples vegetaciones pequeñas, hemocultivos positivos a estafilococos dorado. Fue tratado según los resultados del antibiograma durante 6 semanas y resolvió su extrema gravedad. Conclusiones: La endocarditis infecciosa puede tener manifestaciones muy diferentes al de décadas anteriores; puede aparecer como cuadro agudo fulminante por manifestaciones embólicas y sépticas múltiples(AU)
Introduction: Since the 1950s, the classical clinical presentation of infectious endocarditis (E.I) has varied. Due to the use of antibiotics, illicit drugs, venous catheters, traditional manifestations are not frequent. Objectives: To review the embolic presentation of endocarditis and pecify the preventive measures with the new techniques. Clinical case: A patient with chronic renal insufficiency, diabetic, hypertensive, with central venous catheter, intense chills, fever of 39.5 ° C, intense headache, general state, severe chest pain, cough, expectoration with bright red blood, dyspnea, holosystolic regurgitant murmur, after a section of hemodialysis. Doppler echocardiogram was performed, visualizing multiple small vegetation's, positive blood cultures to golden staphylococci, treatment according to antibiograms for 6 weeks, at the end of which the extreme severity was resolved. Comments: Infective endocarditis can have a very different behavior from previous decades; it can appear as an acute fulminating disease due to embolic, septic, multiple manifestations(AU)
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Dolor en el Pecho , Pruebas de Sensibilidad Microbiana , Diálisis Renal/instrumentación , Disnea/complicaciones , Insuficiencia Renal Crónica/diagnósticoRESUMEN
RESUMEN: Antecedentes: La presión media arterial pulmonar (PMAP) es una variable hemodinámica indispensable para el diagnóstico, clasificación y pronóstico de la Hipertensión Pulmonar (HP). Su cuantificación se realiza en forma invasiva por cateterismo cardíaco derecho (CCD) y no invasivamente por ecocardiografía Doppler. Masuyama propuso su medición mediante el gradiente transvalvular pulmonar diastólico derivado de la velocidad máxima inicial de la regurgitación pulmonar (∆RPi2) correspondiendo cercanamente a la medición invasiva. Objetivos: Revalidar 3 métodos ecocardiográficos que estiman la PMAP y valorar la utilidad del método de Chemla en el Test de Reactividad Vascular Pulmonar (TRVP). Métodos: Estudio prospectivo, observacional, doble ciego divido en dos etapas. A) o I) 30 pacientes se realizó ecocardiografía Doppler diagnóstica en nuestro centro. Se midieron regurgitación tricuspídea (RT) y tiempo de aceleración pulmonar (TAP) para derivar las siguientes ecuaciones: 1) 0.61xPSAP+1.95 (Chemla) 2) Gradiente presión media RT (∆PmRT) +PAD (presión-aurícula derecha) (Aduen) y 3) 79-0.45xTAP o 90-0.60xTAP, según sea el valor del TAP. B) o II) 10 pacientes enrolados para realizar el TRVP comparando la medición ecocardiográfica (Chemla) con CCD. Resultados: En la primera parte del estudio se encontró alta correlación entre las 3 ecuaciones: ChemlaAduen, R2=0.91; Chemla-Kitabatake, R2=0.87; Aduen-Kitabatake, R2=0,91. En la segunda parte comparando la PMAP-Chemla y Cateterismo derecho (CD) obtuvimos alta correlación: en tiempo 0, 30 min y recuperación:(R2=0.87, 0.99, 0.98, respectivamente). Ambas partes del estudio mostraron límites de concordancia satisfactoria con valor medio de la diferencia entre los métodos cercano a 1 en el t30 y tR del TRVP. Conclusión: los métodos dependientes de la medición de la RT son efectivos y confiables para estimar la PMAP. El método de Chemla es útil en el TRVP.
ABSTRACTS: Background: Mean Pulmonary arterial pressure (PMAP)is an indispensable hemodynamic variable for the diagnosis, classification and prognosis of Pulmonary Hypertension (PH). Its quantification is performed invasively by cardiac catheterization and non-invasively by Doppler echocardiography. Masuyama proposed its measurement by the transvalvular diastolic pulmonary gradient derived from the initial maximum velocity of pulmonary regurgitation(ΔPRi2) corresponding closely to the invasive measurement. Objectives: to compare 3 known echocardiographic methods to estimate MPAP and demonstrate the usefulness of the Chemla method in the Pulmonary Vascular Reactivity Test (PVRT). Methods: prospective, observational, double-blind study divided into two stages. A) 30 patients underwent diagnostic Doppler echocardiography. Tricuspid regurgitation (TR) and pulmonary acceleration time (PAT) were measured to derive the equations: 1) 0.61xSPAP + 1.95 (Chemla) 2) Gradient mean pressure TR (ΔPmTR) + RAP (right atrium pressure) (Aduen).3) 79-0.45xPAT o 90-0.60xPAT depending on the value of PAT. B) 10 patients enrolled to PVRT comparing the echocardiographic measurement (Chemla) with right catheterization. Results: in the first part of the study a high correlation between the 3 equations was found : ChemlaAduen, R2 = 0.91; Chemla-Kitabatake, R2=0.87; Aduen-Kitabatake, R2=0.91. In the second part comparing the MPAP-Chemla and RHC we obtained a high correlation in time 0, 30 min and recovery: (R2=0.87,0,99,0.98, respectively). Both parts of the study showed satisfactory limits concordance with mean value of the difference between the methods close to 1 in the t30 and tR of the TRVP. Conclusion: the methods dependent on the measurement of the TR are effective and reliable for estimating MPAP. The Chemla method is useful in the PVRT.
Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Arteria Pulmonar/fisiología , Arteria Pulmonar/diagnóstico por imagen , Circulación Pulmonar/fisiología , Hipertensión Pulmonar/diagnóstico , Resistencia Vascular , Velocidad del Flujo Sanguíneo , Cateterismo Cardíaco , Ecocardiografía Doppler/métodos , Modelos Lineales , Método Doble Ciego , Interpretación Estadística de Datos , Estudios Prospectivos , Presión Arterial/fisiología , Aceleración , Hipertensión Pulmonar/fisiopatología , Pulmón/fisiología , Pulmón/irrigación sanguíneaRESUMEN
BACKGROUND: Methods to guide fluid therapy in spontaneously breathing patients are scarce. No studies have reported the accuracy of end-tidal CO2 (ET-CO2) to predict volume responsiveness in these patients. We sought to evaluate the ET-CO2 gradient (ΔET-CO2) after a passive leg rise (PLR) maneuver to predict volume responsiveness in spontaneously breathing healthy adults. METHODS: We conducted a prospective study in healthy adult human volunteers. A PLR maneuver was performed and cardiac output (CO) was measured by transthoracic echocardiography. ET-CO2 was measured with non-invasive capnographs. Volume responsiveness was defined as an increase in cardiac output (CO) > 12% at 90 s after PLR. RESULTS: Of the 50 volunteers, 32% were classified as volume responders. In this group, the left ventricle outflow tract velocity time integral (VTILVOT) increased from 17.9 ± 3.0 to 20.4 ± 3.4 (p = 0.0004), CO increased from 4.4 ± 1.5 to 5.5 ± 1.6 (p = 0.0), and ET-CO2 rose from 32 ± 4.84 to 33 ± 5.07 (p = 0.135). Within the entire population, PLR-induced percentage ∆CO was not correlated with percentage ∆ET-CO2 (R2 = 0.13; p = 0.36). The area under the receiver operating curve for the ability of ET-CO2 to discriminate responders from non-responders was of 0.67 ± 0.09 (95% CI 0.498-0.853). A ΔET-CO2 ≥ 2 mmHg had a sensitivity of 50%, specificity of 97.06%, positive likelihood ratio of 17.00, negative likelihood ratio of 0.51, positive predictive value of 88.9%, and negative predictive value of 80.5% for the prediction of fluid responsiveness. CONCLUSIONS: ΔET-CO2 after a PLR has limited utility to discriminate responders from non-responders among healthy spontaneously breathing adults.
RESUMEN
AIMS: Evaluate the ability of right atrial (RA) strain to predict systolic pulmonary artery pressure (SPAP). METHODS AND RESULTS: A total of 102 patients were prospectively enrolled. Conventional echocardiographic measures were performed. RA volume was calculated. Mean maximum right ventricle (RV) strain and lateral RA strain were obtained. Pearson's correlation test was used. A multivariate analysis was performed to compare SPAP with RA strain, RV strain, and baseline characteristics of the patients. RA strain was compared between patients with SPAP ≤ 37 mm Hg with those with SPAP > 37 mm Hg. A receiver operating characteristic (ROC) curve was constructed. A P < 0.01 value was considered statistically significant. AGE: 58.7 ± 15.7 years. Male: 46 (45.1%). The correlation coefficient between SPAP and RA strain was -0.64 (P < 0.01, 95% confidence interval (CI): -0.75 to -0.50). Quadratic R2 coefficient = 0.52. In the multivariate analysis, RA strain was independently associated with SPAP level. There were significant differences in RA strain between patients with SPAP ≤ 37 mm Hg (63.3 ± 13.3%; 95% CI: 59.4%-65.1%) and >37 mm Hg (32.7 ± 11.1%; 95% CI: 26.5%-38.39%) (P < 0.01). RA strain < 42.5% was capable to predict a SPAP > 37 mm Hg with 93% sensitivity and 94% specificity, area under the curve (AUC) of 98% (95% CI: 94%-100%). CONCLUSIONS: Right atrial strain is independently associated with SPAP level. RA strain lower than 42.5% can predict a SPAP > 37 mm Hg with high sensitivity and specificity.
Asunto(s)
Función del Atrio Derecho , Ecocardiografía/métodos , Hipertensión Pulmonar/fisiopatología , Arteria Pulmonar/fisiopatología , Anciano , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
Congestion in heart failure patients with reduced ejection fraction (HFrEF) is relevant and closely linked to the clinical course. Bedside blood pressure measurement during the Valsalva maneuver (Val) added to clinical examination may improve the assessment of congestion when compared to NT-proBNP levels and left atrial pressure (LAP) estimation by Doppler echocardiography, as surrogate markers of congestion in HFrEF. A clinical examination, LAP and blood tests were performed in 69 HFrEF ambulatory patients with left ventricular ejection fraction ≤ 40% and sinus rhythm. Framingham Heart Failure Score (HFS) was used to evaluate clinical congestion; Val was classified as normal or abnormal, NT-proBNP was classified as low (< 1000 pg/ml) or high (≥ 1000 pg/ml) and the ratio between Doppler early mitral inflow and tissue diastolic velocity was used to estimate LAP and was classified as low (E/e'< 15) or high (E/e' ≥ 15). A total of 69 patients with HFrEF were included; 27 had a HFS ≥ 2 and 13 of them had high NT-proBNP. HFS ≥ 2 had a 62% sensitivity, 70% specificity and a positive likelihood ratio of 2.08 (p=0.01) to detect congestion. When Val was added to clinical examination, the presence of a HFS ≥ 2 and abnormal Val showed a 100% sensitivity, 64% specificity and a positive likelihood ratio of 2.8 (p = 0.0004). Compared with LAP, the presence of HFS = 2 and abnormal Val had 86% sensitivity, 54% specificity and a positive likelihood ratio of 1.86 (p = 0.03). In conclusion, an integrated clinical examination with the addition Valsalva maneuver may improve the assessment of congestion in patients with HFrEF.
Asunto(s)
Biomarcadores/análisis , Insuficiencia Cardíaca/diagnóstico , Péptido Natriurético Encefálico/análisis , Fragmentos de Péptidos/análisis , Maniobra de Valsalva , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad , Índice de Severidad de la EnfermedadRESUMEN
La evaluación de la congestión en pacientes con insuficiencia cardíaca y fracción de eyección reducida (ICFEr) resulta relevante y estrechamente vinculada al curso clínico. El agregado del comportamiento de la presión arterial durante la maniobra de Valsalva en la cabecera del paciente (VAL) podría mejorar la evaluación clínica de congestión cuando la comparamos con los niveles de NT-proBNP y la estimación de la presión media en la aurícula izquierda por Doppler cardíaco, como subrogantes de congestión. Se realizó un examen clínico con el VAL, un examen de laboratorio y un Doppler cardíaco en 69 pacientes ambulatorios con insuficiencia cardíaca y fracción de eyección ≤ 40% en ritmo sinusal. El score de Framingham ≥ 2 (SFr ≥ 2) se empleó para evaluar congestión clínica. VAL fue clasificado como normal o anormal, el NT-proBNP como bajo (< 1000 pg/ml) o alto (≥ 1000 pg/ml) y la relación entre la velocidad del llenado ventricular rápido y la velocidad del Doppler tisular (E/e') como baja < 15 o alta ≥ 15. Se halló que 13/27 pacientes con SFr ≥ 2 tenían NT-proBNP alto (sensibilidad 62%, especificidad 70% y razón de verosimilitud positiva [LR+] de 2.08, p = 0.01). El agregado del VAL al SFr ≥ 2 mejoró la exactitud diagnóstica (sensibilidad 100%, especificidad 64% y LR+ 2.8 p = 0.0004). Comparado con la E/e', SFr ≥ 2 con VAL anormal mostró sensibilidad 86%, especificidad 56% y LR + 1.86 (p = 0.03). En conclusión, el agregado del comportamiento de la presión durante la maniobra de Valsalva podría mejorar la evaluación clínica de la congestión en la insuficiencia cardíaca.
Congestion in heart failure patients with reduced ejection fraction (HFrEF) is relevant and closely linked to the clinical course. Bedside blood pressure measurement during the Valsalva maneuver (Val) added to clinical examination may improve the assessment of congestion when compared to NT-proBNP levels and left atrial pressure (LAP) estimation by Doppler echocardiography, as surrogate markers of congestion in HFrEF. A clinical examination, LAP and blood tests were performed in 69 HFrEF ambulatory patients with left ventricular ejection fraction ≤ 40% and sinus rhythm. Framingham Heart Failure Score (HFS) was used to evaluate clinical congestion; Val was classified as normal or abnormal, NT-proBNP was classified as low (< 1000 pg/ml) or high (≥ 1000 pg/ml) and the ratio between Doppler early mitral inflow and tissue diastolic velocity was used to estimate LAP and was classified as low (E/e'< 15) or high (E/e' ≥ 15). A total of 69 patients with HFrEF were included; 27 had a HFS ≥ 2 and 13 of them had high NT-proBNP. HFS ≥ 2 had a 62% sensitivity, 70% specificity and a positive likelihood ratio of 2.08 (p=0.01) to detect congestion. When Val was added to clinical examination, the presence of a HFS ≥ 2 and abnormal Val showed a 100% sensitivity, 64% specificity and a positive likelihood ratio of 2.8 (p = 0.0004). Compared with LAP, the presence of HFS ≥ 2 and abnormal Val had 86% sensitivity, 54% specificity and a positive likelihood ratio of 1.86 (p = 0.03). In conclusion, an integrated clinical examination with the addition Valsalva maneuver may improve the assessment of congestion in patients with HFrEF.