Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 671
Filtrar
1.
Int J Neonatal Screen ; 10(3)2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39311362

RESUMEN

In 2015, U.K. newborn screening (NBS) laboratory guidelines were introduced to standardize dried blood spot (DBS) specimen quality acceptance and specify a minimum acceptable DBS diameter of ≥7 mm. The UK 'acceptable' avoidable repeat rate (AVRR) is ≤2%. To assess inter-laboratory variability in specimen acceptance/rejection, two sets of colored scanned images (n = 40/set) of both good and poor-quality DBS specimens were distributed to all 16 U.K. NBS laboratories for evaluation as part of an external quality assurance (EQA) assessment. The mean (range) number of specimens rejected in the first EQA distribution was 7 (1-16) and in the second EQA distribution was 7 (0-16), demonstrating that adherence to the 2015 guidelines was highly variable. A new minimum standard for DBS size of ≥8 mm (to enable a minimum of six sub-punches from two DBS) was discussed. NBS laboratories undertook a prospective audit and demonstrated that using ≥8 mm as the minimum acceptable DBS diameter would increase the AVRR from 2.1% (range 0.55% to 5.5%) to 7.8% (range 0.55% to 22.7%). A significant inverse association between the number of specimens rejected in the DBS EQA distributions and the predicted AVVR (using ≥8 mm minimum standard) was observed (r = -0.734, p = 0.003). Before implementing more stringent standards, the impact of a standard operating procedure (SOP) designed to enable a standardized approach of visual assessment and using the existing ≥7 mm diameter (to enable a minimum of four sub-punches from two DBS) as the minimum standard was assessed in a retrospective audit. Implementation of the SOP and using the ≥7 mm DBS diameter would increase the AVRR from 2.3% (range 0.63% to 5.3%) to 6.5% (range 4.3% to 20.9%). The results demonstrate that there is inconsistency in applying the acceptance/rejection criteria, and that a low AVVR is not an indication of good-quality specimens being received into laboratories. Further work is underway to introduce and maintain standards without increasing the AVRR to unacceptable levels.

2.
Diagnostics (Basel) ; 14(17)2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39272691

RESUMEN

Background Detecting total cholesterol in dried blood spots could aid in identifying individuals with a high likelihood of familial hypercholesterolemia and could be used as a screening measure. This study aims to assess the diagnostic accuracy of dried blood spots on Whatman 903 paper cards using a manual enzymatic technique. Methods: A total of 394 samples were collected as serum and dried blood spots were compared. Cholesterol was determined in serum using the automated reference method, while cholesterol on paper was measured using a manual enzymatic method. Within- and between-day diagnostic variability were analyzed. The correlation between both methods was assessed using Passing-Bablok regression and Bland-Altman plot. Internal validation of our correlation formula was performed on 149 samples, along with external validation of the formula proposed by Corso et al. Results: The within- and between-day coefficient of variation was found to be lower than 10.14% and 14.09%, respectively. Passing-Bablok regression indicated a precision of 0.803 and an accuracy of 0.96. Internal validation precision was measured at 0.716. The resulting positive and negative predicted values were 0.77 and 0.92, respectively, vs. 0.46 and 0.96 from the external formula. Conclusions: Total cholesterol analysis in dried blood spots demonstrates high precision and reproducibility. This method reliably enables the incorporation of this biological marker into neonatal screening for familial hypercholesterolemia detection.

3.
Scand J Clin Lab Invest ; 84(5): 326-335, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39225029

RESUMEN

Breast cancer (BC) is among the most commonly diagnosed cancers. Besides mammography, breast ultrasonography and the routinely monitored protein markers, the variations of small molecular metabolites in blood may be of great diagnostic value. This study aimed to quantify specific metabolite markers with potential application in BC detection. The study enrolled 50 participants, 25 BC patients and 25 healthy controls (CTRL). Dried blood spots (DBS) were utilized as biological media and were quantified via a simplified liquid chromatography tandem mass spectrometry (LC-MS/MS) method, used in expanded newborn screening. The targeted metabolomic analysis included 12 amino acids and 32 acylcarnitines. Statistical analysis revealed a significant variation of metabolic profiles between BC patients and CTRL. Among the 44 metabolites, 18 acylcarnitines and 10 amino acids remained significant after Bonferroni correction, showing increase or decrease and enabled classification of BC patients and CTRL. The well-established LC-MS/MS protocol could provide results within few minutes. Therefore, the combination of an easy-to-handle material-DBS and LC-MS/MS protocol could facilitate BC screening/diagnosis and in the next step applied to other cancer patients, as well.


Asunto(s)
Neoplasias de la Mama , Carnitina , Pruebas con Sangre Seca , Metabolómica , Espectrometría de Masas en Tándem , Humanos , Neoplasias de la Mama/sangre , Neoplasias de la Mama/diagnóstico , Femenino , Pruebas con Sangre Seca/métodos , Metabolómica/métodos , Persona de Mediana Edad , Carnitina/sangre , Carnitina/análogos & derivados , Estudios de Casos y Controles , Adulto , Cromatografía Liquida , Biomarcadores de Tumor/sangre , Anciano , Aminoácidos/sangre , Metaboloma
4.
J Inherit Metab Dis ; 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39227307

RESUMEN

Late-onset Pompe disease (LOPD) is caused by a genetic deficiency of the lysosomal enzyme acid alpha-glucosidase (GAA), leading to progressive limb-girdle weakness and respiratory impairment. The insidious onset of non-specific early symptoms often prohibits timely diagnosis. This study aimed to validate the high-risk screening criteria for LOPD in the Chinese population. A total of 726 patients were included, including 96 patients under 14 years of age. Dried blood spots (DBS) and tandem mass spectrometry (MS/MS) were employed to evaluate serum GAA activity. Forty-four patients exhibited a decreased GAA activity, 16 (2.2%) of which were confirmed as LOPD by genetic testing. Three previously unreported GAA mutations were also identified. The median diagnostic delay was shortened to 3 years, which excelled the previous retrospective studies. At diagnosis, most patients exhibited impaired respiratory function and/or limb-girdle weakness. Elevated serum creatine kinase (CK) levels were more frequently observed in patients who manifested before age 16. Overall, high-risk screening is a feasible and efficient method to identify LOPD patients at an early stage. Patients over 1 year of age with either weakness in axial and/or proximal limb muscles, or unexplained respiratory distress shall be subject to GAA enzymatic test, while CK levels above 2 times the upper normal limit shall be an additional criterion for patients under 16. This modified high-risk screening criteria for LOPD requires further validation in larger Chinese cohorts.

5.
Brain Behav Immun ; 123: 99-107, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39260764

RESUMEN

Attention-deficit hyperactivity disorder (ADHD) is a neurodevelopmental disorder typically detected in childhood. Although ADHD has been demonstrated to have a strong genetic component, environmental risk factors, such as maternal infections during pregnancy, may also play a role. We therefore measured the immunological response to 5 abundant microorganisms (Toxoplasmosis Gondii, cytomegalovirus (CMV), Herpes Simplex Virus 1, Epstein Barr Virus and mycoplasma pneumoniae) in newborn heel prick samples of 1679 ADHD cases and 2948 matching controls as part of the iPSYCH Danish case-cohort study. We found an association between high anti-CMV (OR 1.30, 95 % CI [1.09,1.55], p = 0.015) and anti-mycoplasma (OR 1.30, 95 % CI [1.07,1.59], p = 0.037) signal and those newborns later being diagnosed with ADHD. The risk estimate remained increased when controlling for ADHD polygenic risk score as well as penicillin prescriptions. We saw a dose-response association with the amount of positive anti-microorganism titers increasing the risk of being diagnosed with ADHD later in life (p = 0.01 for the trend), suggesting that the more activated the immune system is prior to or at birth, the higher the risk is for a later diagnosis with ADHD. If the associations are causal, they emphasize the importance of a healthy life style during pregnancy to reduce the risk of infections when pregnant and the associated risks for the child.

6.
Alzheimers Dement ; 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-39234633

RESUMEN

INTRODUCTION: The apolipoprotein E (APOE) ε4 allele carries risk for cognitive impairment, but whether the level of circulating apoE4 protein in carriers affects cognition is unclear, as is how health and lifestyle impact circulating apoE4 levels. METHODS: We assayed apoE4 protein levels in dried blood spots of 12,532 adults aged 50+. Regression analyses tested the likelihood of cognitive impairment between groups and within those with detected apoE4 protein. Predictors of circulating apoE4 were assessed. RESULTS: We detected protein binding that indicates the presence of an APOE ε4 allele in 28.4% of this group. This group was more likely to have cognitive impairment, and this risk increases with age. However, higher apoE4 levels were associated with less likelihood of cognitive impairment within this group. Antihypertensive medication predicted apoE4 protein levels. DISCUSSION: The apoE4 isoform is associated with a deficient protein and worse cognition. This association is modulated by the level of circulating apoE4 protein in ε4 carriers. HIGHLIGHTS: An assay to quantify apoE4 levels from dried blood spot samples was applied. The apoE4 protein was detected as specific binding at ≥30,000 pg/mL in 28.4% of samples. Having the apoE4 protein was associated with worse cognitive performance. Higher apoE4 protein levels in those who have it were associated with better cognition. Cardiovascular factors influenced levels of apoE4 protein.

7.
Forensic Sci Int ; 363: 112173, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39111057

RESUMEN

This study details trends in direct alcohol biomarker concentrations from civil cases within the United Kingdom (UK). Our subject cohort in this study related to family law litigation, where an individual was subject to an alcohol monitoring order by the court. This monitoring was conducted by quantification of alcohol biomarkers Phosphatidlyethanol (PEth) in dried blood spots (DBS) and Ethyl Glucuronide (EtG) and Ethyl Palmitate (EtPa) from hair segments. In total 298 PEth cases predominantly from the South East of England during the period July 2022 to August 2023 were analysed for alcohol biomarkers in DBS and hair. Subjects alcohol intake was classified as abstinence/low alcohol consumption, moderate or excessive alcohol consumption, based on a combination of Society for Hair Testing and PEth Net guidelines. Our results indicate that 33 % of PEth concentrations were consistent with excessive alcohol use (>200 ng/mL DBS), with 36 % consistent with social or moderate alcohol use (20-200 ng/mL DBS). In relation to EtG and EtPa 23 % and 31 % of subjects were classified as excessive alcohol users respectively. This study indicates that DBS sampling of PEth is a more sensitive predictor of alcohol use, in particular, at differentiating between moderate and excessive alcohol use compared to EtG and EtPa testing in hair. The authors suggest that increased frequency in the sampling of PEth in DBS (multiple occasions per month) may provide a more accurate assessment and simplification of the interpretation criteria of alcohol patterns rather than the combined hair testing and DBS sampling that are typically requested by UK courts.


Asunto(s)
Consumo de Bebidas Alcohólicas , Biomarcadores , Glucuronatos , Glicerofosfolípidos , Cabello , Humanos , Glucuronatos/análisis , Cabello/química , Biomarcadores/sangre , Biomarcadores/análisis , Masculino , Femenino , Inglaterra , Adulto , Consumo de Bebidas Alcohólicas/legislación & jurisprudencia , Glicerofosfolípidos/sangre , Pruebas con Sangre Seca , Persona de Mediana Edad , Adulto Joven , Detección de Abuso de Sustancias/métodos , Adolescente , Ácidos Palmíticos
8.
Anal Bioanal Chem ; 2024 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-39180594

RESUMEN

Dried blood spot (DBS) technique has become a new popular topic in anti-doping field in recent years due to its advantages of sample stability and easy operation. It can be employed as a supplementary method to routine urine analysis. However, the small volume of DBS samples (usually 10-20 µL) significantly reduces the application value of this technique. Therefore, the development of sensitive detection methods for the analysis of prohibited substances in DBS is particularly important. In this study, based on the characteristics of low molecular mass peptide (LMMP) drugs, systematic optimization strategies were utilized for the first time to establish a sensitive detection method for LMMPs in DBS. Without using DMSO to enhance mass spectrometry ionization efficiency of peptides, the limits of detection (LOD) ranged between 0.05 and 3.74 ng/mL, significantly better than the previously reported method (0.5-20 ng/mL). This method was validated according to the guidelines of the World Anti-Doping Agency (WADA), and corresponding post-administration study was conducted, demonstrating that the method could be applied to routine analysis of LMMP drugs in DBS. Moreover, since DMSO is not involved, this method also has the potential to simultaneously detect both LMMP and small molecular drugs.

9.
Artículo en Inglés | MEDLINE | ID: mdl-39089063

RESUMEN

Homocysteine, methionine, methylmalonic acid and 2-methylcitric acid are clinically relevant markers in the methionine, propionate, and cobalamin metabolism. This study aimed to develop and validate an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneously determining total homocysteine, methionine, methylmalonic acid and 2-methylcitric acid in dried blood spots. Three 3.2 mm discs were punched from each calibrator, quality control, and sample dried blood spot into a 96-well U-plate. Each sample was spiked with internal standards and extracted. Then the supernatant was transferred to another 96-well U-plate. After nitrogen drying, the dried residues were reconstituted, centrifuged, and the resulting supernatant was transferred to another 96-well plate for analysis. The method was performed using UPLC-MS/MS within 3 min, validated according to guidance documents, and applied to 72 samples from confirmed patients with methionine, propionate, and cobalamin metabolism disorders. The UPLC-MS/MS method provided satisfactory separation of the four analytes. The R2 values were ≥ 0.9937 for all analytes. The recoveries ranged from 94.17 to 114.29 %, and the coefficients of variation for intraday and interday precision were 0.19 % to 5.23 % and 1.02 % to 6.89 %, respectively. No significant carry-over was detected for the four analytes, and most of confirmed samples exhibited biomarker patterns characteristic of the relevant disorders. A simple and fast UPLC-MS/MS method was successfully developed, validated, and applied to clinical samples for the simultaneous determination of total homocysteine, methionine, methylmalonic acid, and 2-methylcitric acid in dried blood spots.


Asunto(s)
Citratos , Pruebas con Sangre Seca , Homocisteína , Límite de Detección , Metionina , Ácido Metilmalónico , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Homocisteína/sangre , Homocisteína/análogos & derivados , Ácido Metilmalónico/sangre , Ácido Metilmalónico/análogos & derivados , Pruebas con Sangre Seca/métodos , Reproducibilidad de los Resultados , Metionina/sangre , Metionina/análogos & derivados , Metionina/química , Modelos Lineales , Citratos/sangre , Citratos/química , Masculino , Femenino , Preescolar
10.
BMC Public Health ; 24(1): 2350, 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39210314

RESUMEN

BACKGROUND: Although behavioral interventions show some promise for reducing stimulant use and achieving durable viral suppression in sexual minority men (SMM) with HIV, scalable mHealth applications are needed to optimize their reach and cost-effectiveness. METHODS: Supporting Treatment Adherence for Resilience and Thriving (START) is a randomized controlled trial (RCT) testing the efficacy and cost-effectiveness of a mHealth application that integrates evidence-based positive affect regulation skills with self-monitoring of adherence and mood. The primary outcome is detectable HIV viral load (i.e., > 300 copies/mL) from self-collected dried blood spot (DBS) specimens at 6 months. Secondary outcomes include detectable DBS viral load at 12 months, self-reported stimulant use severity, anti-retroviral therapy (ART) adherence, and positive affect over 12 months. A national sample of up to 250 SMM with HIV who screen positive for stimulant use disorder and reporting suboptimal ART adherence is being recruited via social networking applications through April of 2024. After providing informed consent, participants complete a run-in period (i.e., waiting period) including two baseline assessments with self-report measures and a self-collected DBS sample. Those who complete the run-in period are randomized to either the START mHealth application or access to a website with referrals to HIV care and substance use disorder treatment resources. Participants provide DBS samples at baseline, 6, and 12 months to measure HIV viral load as well as complete self-report measures for secondary outcomes at quarterly follow-up assessments over 12 months. DISCUSSION: To date, we have paid $117,500 to advertise START on social networking applications and reached 1,970 eligible participants ($59.77 per eligible participant). Although we identified this large national sample of potentially eligible SMM with HIV who screen positive for a stimulant use disorder and report suboptimal ART adherence, only one-in-four have enrolled in the RCT. The run-in period has proven to be crucial for maintaining scientific rigor and reproducibility of this RCT, such that only half of consented participants complete the required study enrollment activities and attended a randomization visit. Taken together, findings will guide adequate resource allocation to achieve randomization targets in future mHealth research SMM with HIV who use stimulants. TRIAL REGISTRATION: This protocol was registered on clinicaltrials.gov (NCT05140876) on December 2, 2021.


Asunto(s)
Infecciones por VIH , Telemedicina , Adulto , Humanos , Masculino , Antirretrovirales/uso terapéutico , Análisis Costo-Beneficio , Infecciones por VIH/tratamiento farmacológico , Cumplimiento de la Medicación , Resiliencia Psicológica , Minorías Sexuales y de Género/psicología , Trastornos Relacionados con Sustancias/terapia , Cumplimiento y Adherencia al Tratamiento/psicología , Carga Viral , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
Indian J Med Microbiol ; 51: 100700, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39127256

RESUMEN

INTRODUCTION: COVID-19 disease continues to be a global health concern. The current protocol for detecting SARS-CoV-2 requires healthcare professionals to draw blood from patients. Recent studies showed that dried blood spot (DBS) is a valuable sampling procedure that can collect a low blood volume without the need for the presence of medical practitioners. This study synthesized the available literature on using DBS as a blood collection tool to diagnose COVID-19 disease. MATERIALS AND METHODS: A comprehensive search utilizing OVID, CINAHL, and Scopus databases was done from inception to March 2023. Five reviewers collected, extracted and organized the study data. RESULTS: This systematic review included 57 articles. DBS was commonly prepared by finger pricking. Most studies showed more favorable results and longer sample stability (more than 1080 days) with lower storage temperature conditions for the DBS. DBS samples were mostly used for serological assays for COVID-19 disease detection. ELISA was the most used detection method (43.66 %). Diagnostic performance of laboratory tests for COVID-19 using DBS sample showed high sensitivity of up to 100 % for immunoassay tests and 100 % specificity in agglutination, PCR, and DELFIA assays. CONCLUSION: DBS sampling coupled with serological testing can be an alternative method for collecting blood and detecting COVID-19 disease. These tests using DBS samples showed excellent diagnostic performance across various geographic locations and demographics.

12.
J Clin Virol ; 174: 105710, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38954911

RESUMEN

Epstein-Barr virus (EBV) is a ubiquitous and oncogenic virus that is associated with various malignancies and non-malignant diseases and EBV DNA detection is widely used for the diagnosis and prognosis prediction for these diseases. The dried blood spots (DBS) sampling method holds great potential as an alternative to venous blood samples in geographically remote areas, for individuals with disabilities, or for newborn blood collection. Therefore, the objective of this study was to assess the viability of detecting EBV DNA load from DBS. Matched whole blood and DBS samples were collected for EBV DNA extraction and quantification detection. EBV DNA detection in DBS presented a specificity of 100 %. At different EBV DNA viral load in whole blood, the sensitivity of EBV DNA detection in DBS was 38.78 % (≥1 copies/mL), 43.18 % (≥500 copies/mL), 58.63 % (≥1000 copies/mL), 71.43 % (≥2000 copies/mL), 82.35 % (≥4000 copies/mL), and 92.86 % (≥5000 copies/mL), respectively. These results indicated that the sensitivity of EBV DNA detection in DBS increased with elevating viral load. Moreover, there was good correlation between EBV DNA levels measured in whole blood and DBS, and on average, the viral load measured in whole blood was about 6-fold higher than in DBS. Our research firstly demonstrated the feasibility of using DBS for qualitative and semi-quantitative detection of EBV DNA for diagnosis and surveillance of EBV-related diseases.


Asunto(s)
ADN Viral , Pruebas con Sangre Seca , Infecciones por Virus de Epstein-Barr , Herpesvirus Humano 4 , Sensibilidad y Especificidad , Carga Viral , Humanos , Herpesvirus Humano 4/genética , Herpesvirus Humano 4/aislamiento & purificación , Carga Viral/métodos , Infecciones por Virus de Epstein-Barr/diagnóstico , Infecciones por Virus de Epstein-Barr/virología , Infecciones por Virus de Epstein-Barr/sangre , ADN Viral/sangre , Pruebas con Sangre Seca/métodos , Manejo de Especímenes/métodos , Sangre/virología
13.
Brain Behav Immun ; 120: 545-553, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38971206

RESUMEN

Dried blood spots (DBS) provide a minimally invasive method to assess inflammatory markers and can be collected remotely at-home or in-person in the lab. However, there is a lack of methodological information comparing these different collection methods and in older adults. We investigated the feasibility (including adherence, yield, quality, and participant preferences) and measurement properties (reliability, validity) of remotely collected DBS inflammatory markers in older adults. Participants (N = 167, mean age = 72, range: 60-96 years) collected their own DBS (finger prick on filter paper) during three remote interviews over âˆ¼ 6 months. Within 4-5 days on average of their last remote interview, a subset of 41 participants also attended an in-person lab visit that included a researcher-collected DBS sample, venous blood draw, and survey to assess participant preferences of DBS collection. DBS and venous blood were assayed for CRP, IL-6, and TNF-α. Adherence: 98% of expected DBS samples (493 out of 501) were completed and mailed back to the lab. Yield: 97% of DBS samples were sufficient for all assays. Quality: On average, 0.80 fewer optimal spots (60uL of blood that filled the entire circle) were obtained remotely vs. in-person (p = 0.013), but the number of useable or better spots (at least 30-40uL of blood) did not differ (p = 0.89). Preference: A slight majority of participants (54%) preferred in-person DBS collection. Reliability: DBS test-retest reliabilities were good: CRP (ICC = 0.74), IL-6 (ICC = 0.76), and TNF-α (ICC = 0.70). Validity: Inflammatory levels from DBS correlated strongly with levels from venous blood (r = 0.60-0.99) and correlated as expected with sociodemographic and physical health and function variables. Older adults can remotely collect their own DBS to acquire reliable and valid inflammatory data. Remote DBS collection is highly feasible and may allow for inflammatory markers to be assessed in larger, more representative samples than are possible with lab- or clinic-based research designs.


Asunto(s)
Biomarcadores , Pruebas con Sangre Seca , Inflamación , Humanos , Anciano , Femenino , Masculino , Persona de Mediana Edad , Pruebas con Sangre Seca/métodos , Anciano de 80 o más Años , Biomarcadores/sangre , Reproducibilidad de los Resultados , Inflamación/sangre , Interleucina-6/sangre , Factor de Necrosis Tumoral alfa/sangre , Estudios de Factibilidad , Proteína C-Reactiva/análisis , Proteína C-Reactiva/metabolismo , Recolección de Muestras de Sangre/métodos
14.
Anal Bioanal Chem ; 416(20): 4635-4645, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38949681

RESUMEN

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.


Asunto(s)
17-alfa-Hidroxiprogesterona , Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Pruebas con Sangre Seca/métodos , 17-alfa-Hidroxiprogesterona/sangre , Recién Nacido , Cromatografía Liquida/métodos , Límite de Detección , Estándares de Referencia , Hiperplasia Suprarrenal Congénita/sangre , Hiperplasia Suprarrenal Congénita/diagnóstico , Tamizaje Neonatal/métodos , Reproducibilidad de los Resultados , Técnicas de Dilución del Indicador , Femenino , Valores de Referencia
15.
bioRxiv ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38826424

RESUMEN

Dried blood spot (DBS) cards can be used as an alternative sample collection method to plasma, however, there is no optimized elution protocol for DBS cards specifically for hepatitis B surface antibody (anti-HBs) testing. The study aimed to develop a DBS elution protocol for anti-HBs quantification. Our study sought to determine the ideal phosphate-buffered saline (PBS) buffer volume to use by comparing three PBS volumes (300uL, 450uL, and 500uL), and the optimal time to agitate DBS discs on a plate shaker (1hr, 2hrs, 3hrs, and 4hrs) to yield DBS anti-HBs concentrations that are comparable to corresponding plasma anti-HBs concentrations. The optimal DBS storage temperature (25°C, -20°C, and -80°C) was investigated to determine the ideal long-term storage temperature of the cards. Residual samples were used for optimization (2019-2021). A total of 50 DBS-plasma pairs was used throughout the study, with plasma anti-HBs concentrations being used as the golden standard to compare. The analysis of results was carried out by determining the p-values of the Wilcoxon sign rank. A two-way analysis of variance (ANOVA) was also performed to determine the impact of PBS elution volumes, elution time, and storage temperature on the anti-HBs concentration of DBS samples on STATA Version 15.0. No statistically significant difference between the DBS-plasma anti-HBs pairs was observed when using 450 or 500uL of PBS buffer and when samples were agitated for 3 hours (p=0.594, p=0.499 respectively). The optimal storage temperature for DBS cards was 25°C because the results showed no statistically significant difference between DBS-plasma anti-HBs titers (p=0.594). The two-way ANOVA analysis showed that elution volumes and time had no statistically significant impact on the DBS anti-HBs concentrations, p=0.948 and p=0.381 respectively. Storage temperature had a statistically significant impact on the DBS anti-HBs concentrations, p=0.002. The optimized DBS elution protocol for anti-HBs quantification will help monitor vaccine efficacy in infants due to the low sample volumes required compared to plasma and also can be used for anti-HBs testing in resource-limited areas around the country.

16.
Crit Rev Clin Lab Sci ; : 1-24, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38855982

RESUMEN

This scoping review aimed to synthesize the analytical techniques used and methodological limitations encountered when undertaking secondary research using residual neonatal dried blood spot (DBS) samples. Studies that used residual neonatal DBS samples for secondary research (i.e. research not related to newborn screening for inherited genetic and metabolic disorders) were identified from six electronic databases: Cochrane Library, Cumulative Index to Nursing and Allied Health Literature (CINAHL), Embase, Medline, PubMed and Scopus. Inclusion was restricted to studies published from 1973 and written in or translated into English that reported the storage, extraction and testing of neonatal DBS samples. Sixty-seven studies were eligible for inclusion. Included studies were predominantly methodological in nature and measured various analytes, including nucleic acids, proteins, metabolites, environmental pollutants, markers of prenatal substance use and medications. Neonatal DBS samples were stored over a range of temperatures (ambient temperature, cold storage or frozen) and durations (two weeks to 40.5 years), both of which impacted the recovery of some analytes, particularly amino acids, antibodies and environmental pollutants. The size of DBS sample used and potential contamination were also cited as methodological limitations. Residual neonatal DBS samples retained by newborn screening programs are a promising resource for secondary research purposes, with many studies reporting the successful measurement of analytes even from neonatal DBS samples stored for long periods of time in suboptimal temperatures and conditions.

17.
Anal Chim Acta ; 1315: 342756, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38879204

RESUMEN

BACKGROUND: Dried blood spots (DBSs) collected and archived in newborn screening programs (NSP) represent a potentially valuable resource for assessing exposure to a range of organic and inorganic chemicals in newborns. This study develops and optimizes a method to measure polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs), and organochlorine pesticides (OCPs) in DBS using the isotope dilution technique, ultrasonic-assisted liquid-liquid extraction, simple cleanup, triple quadrupole GC-MS/MS analysis, and background correction. RESULTS: We minimize the number of extraction repetitions and the volume of solvent, which helps increase throughput while minimizing the potential for contamination. We obtained high recovery and precision for most compounds, and method detection limits (MDLs) were sufficiently low to detect the more prevalent compounds based on representative sample of the US population. MDLs averaged 0.020 ng/mL (recovery: 107 %, precision: 4 %) for PCNs, 0.021 ng/mL (recovery: 97 %, precision: 4 %) for PCBs, 0.021 ng/mL (recovery: 117 %, precision: 2 %) for OCPs, and 0.021 ng/mL (recovery: 96 %, precision: 3 %) for PBDEs. SIGNIFICANCE AND NOVELTY: To our knowledge, this is the first study presenting an analytical method and for PCNs in DBS, and one of the few studies providing an assessment of method performance for persistent organic pollutants in DBS. The optimized method can be applied to a wide range of applications, including exposure assessment, environmental epidemiology, forensics, environmental surveillance, and ecological monitoring.


Asunto(s)
Pruebas con Sangre Seca , Naftalenos , Contaminantes Orgánicos Persistentes , Espectrometría de Masas en Tándem , Pruebas con Sangre Seca/métodos , Humanos , Naftalenos/sangre , Contaminantes Orgánicos Persistentes/sangre , Espectrometría de Masas en Tándem/métodos , Éteres Difenilos Halogenados/sangre , Éteres Difenilos Halogenados/análisis , Bifenilos Policlorados/sangre , Bifenilos Policlorados/análisis , Extracción Líquido-Líquido/métodos , Hidrocarburos Clorados/sangre , Hidrocarburos Clorados/análisis , Recién Nacido , Cromatografía de Gases y Espectrometría de Masas/métodos , Límite de Detección , Plaguicidas/sangre , Plaguicidas/análisis
18.
BMC Med Genomics ; 17(1): 171, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943113

RESUMEN

Iodine deficiency-induced goiter continues to be a global public health concern, with varying manifestations based on geography, patient's age, and sex. To gain insights into clinical occurrences, a retrospective study analyzed medical records from patients with iodine deficiency-induced goiter or thyroid cancer who underwent surgery at the Community Hospital in Riehen, Switzerland, between 1929 and 1989. Despite today's adequate iodine supplementation, a significant risk for iodine-independent goiter remains in Switzerland, suggesting that genetic factors, among others, might be involved. Thus, a pilot study exploring the feasibility of genetic analysis of blood spots from these medical records was conducted to investigate and enhance the understanding of goiter development, potentially identify genetic variations, and explore the influence of dietary habits and other environmental stimuli on the disease.Blood prints from goiter patients' enlarged organs were collected per decade from medical records. These prints had been made by pressing, drawing, or tracing (i.e., pressed and drawn) the removed organs onto paper sheets. DNA analysis revealed that its yields varied more between the prints than between years. A considerable proportion of the samples exhibited substantial DNA degradation unrelated to sample collection time and DNA mixtures of different contributors. Thus, each goiter imprint must be individually evaluated and cannot be used to predict the success rate of genetic analysis in general. Collecting a large sample or the entire blood ablation for genetic analysis is recommended to mitigate potential insufficient DNA quantities. Researchers should also consider degradation and external biological compounds' impact on the genetic analysis of interest, with the dominant contributor anticipated to originate from the patient's blood.


Asunto(s)
Bocio , Yodo , Neoplasias de la Tiroides , Humanos , Suiza , Neoplasias de la Tiroides/genética , Neoplasias de la Tiroides/sangre , Bocio/genética , Bocio/sangre , Yodo/deficiencia , Masculino , Femenino , Alemania , Historia del Siglo XX , Estudios Retrospectivos , Persona de Mediana Edad , Adulto
19.
Artículo en Inglés | MEDLINE | ID: mdl-38917652

RESUMEN

Dried Blood Spots (DBS) revolutionize therapeutic drug monitoring using LC-MS for the precise quantification of cardiovascular drugs (CDs), enabling personalized treatment adapted to patient-specific pharmacokinetics with minimal invasiveness. This study aims to achieve simultaneous quantification of eight CDs in DBS, overcoming physicochemical challenges. A two-step protein precipitation method was used for simple and precise sample preparation. The drugs were analyzed using LC-MS/MS in ESI positive-ion mode, showing high sensitivity and linearity, with a correlation coefficient (r2) exceeding 0.999, after being separated on a reversed-phase chromatography by gradient elution of DW-acetonitrile containing 0.1 % formic acid + 2 mM ammonium formate. The validation results indicate good selectivity, with no observed matrix effect and carry-over. The intra- and inter-day accuracy and precision were within 6 % for most drugs, except for digoxin and deslanoside at low therapeutic levels where the variation was within 20 %. Stability tests confirmed suitable DBS handling and storage conditions, indicating drug stability for at least 30 days at room temperature. The analysis of whole spot has demonstrated remarkable precision and reliability in all target drugs. The analysis of 3 mm internal diameter discs, punched in and out of DBS, presumed to contain 3 µL of blood, showed acceptable accuracy for most drugs, with less polar drugs like digoxin and deslanoside showing lower accuracy, indicating a need for further correction due to non-uniform drug distribution. Consequently, the developed LC-MS/MS method enables the quantification of multiple CDs in a single DBS analysis, while suggesting the potential for accuracy-based analysis.


Asunto(s)
Fármacos Cardiovasculares , Pruebas con Sangre Seca , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Pruebas con Sangre Seca/métodos , Humanos , Reproducibilidad de los Resultados , Modelos Lineales , Cromatografía Liquida/métodos , Fármacos Cardiovasculares/sangre , Fármacos Cardiovasculares/farmacocinética , Límite de Detección , Monitoreo de Drogas/métodos
20.
J Infect Public Health ; 17(8): 102476, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38901117

RESUMEN

BACKGROUND: In Equatorial Guinea, only 54 % of people living with HIV know their HIV status. There are no confirmatory or molecular diagnostic techniques for early diagnosis or monitoring of infection in the country. Rapid diagnostic tests can induce false-positive diagnoses if used as a confirmatory technique. Our study aimed to identify the challenges of early HIV diagnosis in Equatorial Guinea by analyzing the rate of false positive diagnoses, diagnostic and therapeutic delays, and treatment failures among those on antiretroviral therapy. METHODS: From 2019-2022, dried blood from 341 children, adolescents and adults diagnosed in Equatorial Guinea as HIV-positive by rapid diagnostic testing, and from 54 HIV-exposed infants were collected in Bata and sent to Madrid to confirm HIV-infection by molecular (Xpert HIV-1Qual, Cepheid) and/or serological confirmatory assays (Geenius-HIV-1/2, BioRad). HIV diagnostic delay (CD4 <350cells/mm3), advanced disease at diagnosis (CD4 <200cells/mm3) and antiretroviral treatment delay and failure (viraemia >1,000RNA-HIV-1-copies/ml) were also studied after viral quantification (XpertVL HIV-1, Cepheid). RESULTS: False-positive diagnoses were identified in 5 % of analysed samples. HIV infection was confirmed in 90.5 % of previously diagnosed patients in Equatorial Guinea and 3.7 % of HIV-exposed children undiagnosed in the field. Two-thirds of each new HIV patient had delayed diagnosis, and one-third had advanced disease. Treatment delay occurred in 28.3 % of patients, being around four times more likely in adolescents/adults than children. More than half (56 %) of 232 treated patients presented treatment failure, being significantly higher in children/adolescents than in adults (82.9 %/90 % vs. 45.6 %, p < 0.001). CONCLUSION: We identified some challenges of early HIV diagnosis in Equatorial Guinea, revealing a high rate of false positive diagnoses, diagnostic/treatment delays, and treatment failures that need to be addressed. The implementation of more accurate rapid diagnostic techniques and confirmatory tests, along with improving access to care, treatment, awareness, and screening, would contribute to controlling the spread of HIV in the country.


Asunto(s)
Diagnóstico Tardío , Infecciones por VIH , Tiempo de Tratamiento , Humanos , Guinea Ecuatorial , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , Adolescente , Niño , Masculino , Femenino , Adulto , Preescolar , Diagnóstico Tardío/estadística & datos numéricos , Adulto Joven , Lactante , VIH-1/aislamiento & purificación , Reacciones Falso Positivas , Persona de Mediana Edad , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA