Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.259
Filtrar
1.
J Crohns Colitis ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38828738

RESUMEN

BACKGROUND: Colonic fibrosis has important clinical implications in ulcerative colitis. Ultrasound imaging has emerged as a convenient and reliable tool in diagnosis of inflammatory bowel disease. We aimed to explore the potential use of ultrasound to evaluate UC fibrosis. METHODS: Consecutive UC patients who had proctocolectomy from July 2022 to Sep 2023 were enrolled in the study. Patients underwent bowel ultrasound examination and ultrasound elastography imaging prior to surgery. Milan ultrasound criteria (MUC) was calculated and bowel wall stiffness was determined using two mean strain ratios (MSRs). Degree of colonic fibrosis and inflammation was measured upon histological analysis. ROC analysis was used to evaluate the performance of ultrasound-derived parameters to predict fibrosis. RESULTS: Fifty-six patients were enrolled with 112 segments included in analysis. The median fibrosis score was 2 (0-4) and the median Geboes score was 5 (0-13) and these two scores were significantly correlated (p<0.001). The muscularis mucosa thickness was significantly higher in moderate-severe fibrosis than none-mild fibrosis (p=0.003) but bowel wall thickness was not (p=0.082). The strain ratios (p<0.001) and MUC (p=0.010) was significantly higher in involved than non-involved segments. The strain ratios were correlated with fibrosis score (p<0.001) but not MUC (p=0.387). At ROC analysis, MSR1 had an AUC of 0.828 (cutoff value 3.07, 95% CI 0.746-0.893, p<0.001) to predict moderate-severe fibrosis. CONCLUSION: Ultrasound elastography imaging could predict the degree of colonic fibrosis in UC. Application of this technique could help disease monitoring and decision-making of UC patients.

2.
Muscle Nerve ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38828855

RESUMEN

INTRODUCTION/AIMS: The current diagnosis of ulnar neuropathy at the elbow (UNE) relies mainly on the clinical presentation and nerve electrodiagnostic (EDX) testing, which can be uncomfortable and yield false negatives. The aim of this study was to investigate the diagnostic value of conventional ultrasound, shear wave elastography (SWE), and superb microvascular imaging (SMI) in diagnosing UNE. METHODS: We enrolled 40 patients (48 elbows) with UNE and 48 healthy volunteers (48 elbows). The patients were categorized as having mild, moderate or severe UNE based on the findings of EDX testing. The cross-sectional area (CSA) was measured using conventional ultrasound. Ulnar nerve (UN) shear wave velocity (SWV) and SMI were performed in a longitudinal plane. RESULTS: Based on the EDX findings, UNE severity was graded as mild in 4, moderate in 10, and severe in 34. The patient group showed increased ulnar nerve CSA and stiffness at the site of maximal enlargement (CSA mean at the site of max enlargement [CSAmax] and SWV mean at the site of max enlargement [SWVmax]), ulnar nerve CSA ratio, and stiffness ratio (elbow-to-upper arm), compared with the control group (p < .001). Furthermore, the severe UNE group showed higher ulnar nerve CSAmax and SWVmax compared with the mild and moderate UNE groups (p < .001). The cutoff values for diagnosis of UNE were 9.5 mm2 for CSAmax, 3.06 m/s for SWVmax, 2.00 for CSA ratio, 1.36 for stiffness ratio, and grade 1 for SMI. DISCUSSION: Our findings suggest that SWE and SMI are valuable diagnostic tools for the diagnosis and assessment of severity of UNE.

3.
J Periodontal Res ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837789

RESUMEN

AIM: To assess ultrasonographic tissue elasticity at teeth and implant sites and its variation after peri-implant soft tissue augmentation with a connective tissue graft (CTG). METHODS: Twenty-eight patients, each contributing with one clinically healthy dental implant exhibiting a soft tissue dehiscence (PSTD), were included. Implant sites were augmented with CTG and monitored over 12 months. Ultrasonographic strain elastography, expressed as strain ratios (SR1, SR2, and SR3, respectively) was assessed at baseline, 6-, and 12-month, and compared with the corresponding contralateral homologous natural tooth. SR1 assessed the strain/elasticity of the midfacial coronal portion of the soft tissue in comparison to the natural tooth crown/implant-supported crown, SR2 evaluated the strain of the midfacial coronal soft tissue in relation to the one of the alveolar mucosa, while SR3 depicted the strain of the midfacial soft tissue in relation to the interproximal soft tissue on the transverse ultrasound scan. RESULTS: SR1 in natural dentition and at implant sites was 0.20 ± 0.08 and 0.30 ± 0.14, respectively (p = .002), indicating that the coronal portion of the soft tissue around teeth is generally more elastic than its counterpart around dental implants. Soft tissue augmentation with CTG promoted an increased stiffness of the midfacial coronal portion of the soft tissue over 12 months (p < .001 for SR1, SR2, and SR3). Strain ratios at the 12-month time points were significantly higher than the values observed at 6 months (p < .001). Regression analysis demonstrated that strain elastography ratios in natural dentition were significantly associated with keratinized gingiva width, and gingival thickness. At implant sites, SR1 was significantly associated with keratinized mucosa width and mucosal thickness (p < .001 for both correlations), SR2 was significantly associated with keratinized mucosa width (p = .013), and SR3 was significantly associated with the surgical technique performed in combination with CTG (p = .022). CONCLUSION: Ultrasound strain elastography captures and quantifies tissue elasticity and its changes after soft tissue augmentation. A different baseline tissue elasticity was observed between teeth and dental implants in the most coronal aspect of the soft tissue. The main factors affecting tissue elasticity-related outcomes were the keratinized tissue width, and mucosal thickness.

4.
Neuroimage ; 295: 120662, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38823503

RESUMEN

Understanding the physiological processes in aging and how neurodegenerative disorders affect cognitive function is a high priority for advancing human health. One specific area of recently enabled research is the in vivo biomechanical state of the brain. This study utilized reverberant optical coherence elastography, a high-resolution elasticity imaging method, to investigate stiffness changes during the sleep/wake cycle, aging, and Alzheimer's disease in murine models. Four-dimensional scans of 44 wildtype mice, 13 mice with deletion of aquaporin-4 water channel, and 12 mice with Alzheimer-related pathology (APP/PS1) demonstrated that (1) cortical tissue became softer (on the order of a 10% decrease in shear wave speed) when young wildtype mice transitioned from wake to anesthetized, yet this effect was lost in aging and with mice overexpressing amyloid-ß or lacking the water channel AQP4. (2) Cortical stiffness increased with age in all mice lines, but wildtype mice exhibited the most prominent changes as a function of aging. The study provides novel insight into the brain's biomechanics, the constraints of fluid flow, and how the state of brain activity affects basic properties of cortical tissues.

5.
JVS Vasc Sci ; 5: 100198, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38846626

RESUMEN

Objective: Strain has become a viable index for evaluating abdominal aortic aneurysm stability after endovascular aneurysm repair (EVAR). In addition, literature has shown that healthy aortic tissue requires a degree of strain to maintain homeostasis. This has led to the hypothesis that too much strain reduction conferred by a high degree of graft oversizing is detrimental to the aneurysm neck in the seal zone of abdominal aortic aneurysms after EVAR. We investigated this in a laboratory experiment by examining the effects that graft oversizing has on the pressure-normalized strain ( ε ρ + ¯ /pulse pressure [PP]) reduction using four different infrarenal EVAR endografts and our ultrasound elastography technique. Approximate graft oversizing percentages were 20% (30 mm phantom-graft combinations), 30% (28 mm phantom-graft combinations), and 50% (24 mm phantom-graft combinations). Methods: Axisymmetric, 10% by mass polyvinyl alcohol phantoms were connected to a flow simulator. Ultrasound elastography was performed before and after implantation with the four different endografts: (1) 36 mm polyester/stainless steel, (2) 36 mm polyester/electropolished nitinol, (3) 35 mm polytetrafluoroethylene (PTFE)/nitinol, and (4) 36 mm nitinol/polyester/platinum-iridium. Five ultrasound cine loops were taken of each phantom-graft combination. They were analyzed over two different cardiac cycles (end-diastole to end-diastole), yielding a total of 10 maximum mean principal strain ( ε ρ + ¯ ) values. ε ρ + ¯ was divided by pulse pressure to yield pressure-normalized strain ( ε ρ + ¯ /PP). An analysis of variance was performed for graft comparisons. We calculated the average percent ε ρ + ¯ /PP reduction by manufacturer and percent oversizing. These values were used for linear regression analysis. Results: Results from one-way analysis of variance showed a significant difference in ε ρ + ¯ /PP between the empty phantom condition and all oversizing conditions for all graft manufacturers (F(3, 56) = 106.7 [graft A], 132.7 [graft B], 106.5 [graft C], 105.7 [graft D], P < .0001 for grafts A-D). There was a significant difference when comparing the 50% condition with the 30% and 20% conditions across all manufacturers by post hoc analysis (P < .0001). No significant difference was found when comparing the 20% and 30% oversizing conditions for any of the manufacturers or when comparing ε ρ + ¯ /PP values across the manufacturers according to percent oversize. Linear regression demonstrated a significant positive correlation between the percent graft oversize and the all-graft average percent ε ρ + ¯ /PP reduction ( R 2  = 0.84, P < .0001). Conclusions: This brief report suggests that a 10% increase in graft oversizing leads to an approximate 5.9% reduction in ε ρ + ¯ /PP on average. Applied clinically, this increase may result in increased stiffness in axisymmetric vessels after EVAR. Further research is needed to determine if this is clinically significant.

7.
Heliyon ; 10(11): e31742, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38845994

RESUMEN

This review aims to explore the current application of Cranial Ultrasound Screening (CUS) in the diagnosis and treatment of brain diseases in extremely preterm infants. It also discusses the potential role of emerging ultrasound-derived technologies such as Super Microvascular Structure Imaging (SMI), Shear Wave Elastography (SWE), Ultrafast Doppler Ultrasound (UfD), and 3D ventricular volume assessment and automated segmentation techniques in clinical practice. A systematic search of medical databases was conducted using the keywords "(preterm OR extremely preterm OR extremely low birth weight) AND (ultrasound OR ultrasound imaging) AND (neurodevelopment OR brain development OR brain diseases OR brain injury OR neuro*)" to identify relevant literature. The titles, abstracts, and full texts of the identified articles were carefully reviewed to determine their relevance to the research topic. CUS offers unique advantages in early screening and monitoring of brain diseases in extremely preterm infants, as it can be performed at the bedside without the need for anesthesia or special monitoring. This technique facilitates early detection and intervention of conditions such as intraventricular hemorrhage, white matter injury, hydrocephalus, and hypoxic-ischemic injury in critically ill preterm infants. Continuous refinement of the screening and follow-up processes provides reliable clinical decision-making support for healthcare professionals and parents. Emerging ultrasound technologies, such as SWE, SMI, and UfD, are being explored to provide more accurate and in-depth understanding of brain diseases in extremely preterm infants. SWE has demonstrated its effectiveness in assessing the elasticity of neonatal brain tissue, aiding in the localization and quantification of potential brain injuries. SMI can successfully identify microvascular structures in the brain, offering a new perspective on neurologic diseases. UfD provides a high-sensitivity and quantitative imaging method for the prevention and treatment of neonatal brain diseases by detecting subtle changes in red blood cell movement and accurately assessing the status and progression of brain diseases. CUS and its emerging technologies have significant applications in the diagnosis and treatment of brain diseases in extremely preterm infants. Future research aims to address current technical challenges, optimize and enhance the clinical decision-making capabilities related to brain development, and improve the prevention and treatment outcomes of brain diseases in extremely preterm infants.

8.
Heliyon ; 10(11): e31726, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38841497

RESUMEN

Measuring elasticity without physical contact is challenging, as current methods often require deconstruction of the test sample. This study addresses this challenge by proposing and testing a photoacoustic effect-based method for measuring the elasticity of polydimethylsiloxane (PDMS) at various mixing ratios, which may be applied on the wide range of applications such as biomedical and optical fields. A dual-light laser source of the photoacoustic (PA) system is designed, employing cross-correlation signal processing techniques. The platform systems and a mathematical model for performing PDMS elasticity measurements are constructed. During elasticity detection, photoacoustic signal features, influenced by hardness and shapes, are analyzed using cross-correlation calculations and phase difference detection. Results from phantom tests demonstrate the potential of predicting Young's modulus using the cross-correlation method, aligning with the American Society for Testing and Materials (ASTM) standard samples. However, accuracy may be affected by mixed materials and short tubes. Normalization or calibration of signals is suggested for aligning with Young's coefficient.

9.
Sci Rep ; 14(1): 12605, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38824246

RESUMEN

The diagnostic value of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules is still controversial, so we used meta-analysis to seek controversial answers. The PubMed, OVID, and CNKI databases were searched according to the inclusion and exclusion criteria. The literature was selected from the establishment of each database to February 2024. The QUADAS-2 tool assessed diagnostic test accuracy. SROC curves and Spearman's correlation coefficient were made by Review Manager 5.4 software to assess the presence of threshold effects in the literature. Meta-Disc1.4 software was used for Cochrane-Q and χ2 tests, which be used to evaluate heterogeneity, with P-values and I2 indicating heterogeneity levels. The appropriate effect model was selected based on the results of the heterogeneity test. Stata18.0 software was used to evaluate publication bias. The diagnostic accuracy of contrast-enhanced ultrasound combined with ultrasound elastography for benign and malignant thyroid nodules was evaluated by calculating the combined sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, DOR, and area under the SROC curve. A total of 31 studies included 3811 patients with 4718 nodules were analyzed. There is no heterogeneity caused by the threshold effect, but there is significant non-threshold heterogeneity. Combined diagnostic metrics were: sensitivity = 0.93, specificity = 0.91, DOR = 168.41, positive likelihood ratio = 10.60, and negative likelihood ratio = 0.07. The SROC curve area was 0.97. Contrast-enhanced ultrasound and elastography show high diagnostic accuracy for thyroid nodules, offering a solid foundation for early diagnosis and treatment.Trial registration. CRD42024509462.


Asunto(s)
Medios de Contraste , Diagnóstico por Imagen de Elasticidad , Nódulo Tiroideo , Ultrasonografía , Humanos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía/métodos , Diagnóstico Diferencial , Sensibilidad y Especificidad , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Neoplasias de la Tiroides/diagnóstico
10.
J Cardiol Cases ; 29(6): 254-257, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38826762

RESUMEN

A 68-year-old man was diagnosed with pericarditis associated with immunoglobulin G4-related disease and was administered prednisolone 2 years prior to presentation. During the process of tapering off from prednisolone 1 year later, edema of the lower legs and pleural effusion worsened. He gradually developed dyspnea on exertion, and laboratory examinations revealed elevated liver enzyme levels. Diuretics were administered; however, the symptoms did not resolve. Transthoracic echocardiography and cardiac catheterization revealed findings consistent with those of constrictive pericarditis. Pericardiectomy was considered and the perioperative risks due to possible recovery from liver dysfunction were discussed. Combinational elastography was subsequently performed. The results indicated the absence of liver fibrosis, suggesting that liver dysfunction was attributable to liver congestion; thus, the liver dysfunction was considered reversible. Subsequently, pericardiectomy was performed. Given that constrictive pericarditis can lead to liver dysfunction due to congestion, the perioperative risk is often controversial when considering surgical interventions. Learning objective: Combinational elastography may be useful in the preoperative evaluation of patients with cardiac diseases complicated by liver dysfunction to distinguish liver fibrosis, understand the pathogenesis of liver dysfunction, and determine subsequent treatment strategies.

11.
Gynecol Endocrinol ; 40(1): 2352139, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38733361

RESUMEN

OBJECTIVE: The main purpose of this systematic review and meta-analysis was to investigate the diagnostic value of ultrasound elastography in the evaluation of polycystic ovary syndrome (PCOS). METHODS: A comprehensive and methodical investigation was carried out in the databases of PubMed, EMBASE, Cochrane, Scopus, Web of Science, and China National Knowledge Infrastructure, covering the entire duration of these databases until October 18, 2023. The primary purpose of this research was to evaluate and contrast ovarian tissue elasticity in people with and without PCOS. The elasticity of ovarian tissue was quantified using standardized mean difference (SMD). RESULTS: A total of eight studies were ultimately selected for systematic evaluation and meta-analysis. Five studies used shear wave elastography (SWE) as a diagnostic tool, and it was discovered that women with PCOS had higher levels of ovarian shear wave elasticity than their healthy counterparts. The SMD was determined to be 1.86 kilopascal (95% CI: 1.27 to 2.44). Three studies were conducted using strain elastography (SE) to compare the ovarian strain ratio of patients with PCOS to that of a healthy control group. The SMD for the PCOS group was 2.07 (95% CI: 1.79 to 2.34), which indicated that the ovarian strain ratio was significantly higher in that group. CONCLUSION: This systematic review and meta-analysis found that women with PCOS had stiffer ovarian tissue than women without the disorder. Ultrasound elastography may provide clinicians with value beyond 2D ultrasound in the diagnosis of PCOS.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Síndrome del Ovario Poliquístico , Síndrome del Ovario Poliquístico/diagnóstico por imagen , Síndrome del Ovario Poliquístico/fisiopatología , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Ovario/diagnóstico por imagen , Elasticidad
12.
Quant Imaging Med Surg ; 14(5): 3447-3460, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38720850

RESUMEN

Background: Magnetic resonance elastography (MRE) is a non-invasive method to measure the viscoelastic properties of tissue and has been applied in multiple abdominal organs. However, abdominal MRE suffers from detrimental breathing motion causing misalignment of structures between repeated acquisitions for different MRE dimensions (e.g., motion encoding directions and wave phase offsets). This study investigated motion correction strategies to resolve all breathing motion on sagittal free-breathing MRE acquisitions in a phantom, in healthy volunteers and showed feasibility in patients. Methods: First, in silico experiments were performed on a static phantom dataset with simulated motion. Second, eight healthy volunteers underwent two sagittal MRE acquisitions in the pancreas and right kidney. The multi-frequency free-breathing spin-echo echo-planar-imaging (SE-EPI) MRE consisted of four frequencies (30, 40, 50, 60 Hz), eight wave-phase offsets, with 3 mm3 isotropic voxel size. Following data re-sorting in different number of motion states (4 till 12) based on respiratory waveform signal, three intensity-based registration methods (monomodal, multimodal, and phase correlation) and non-rigid local registration were compared. A ranking method was used to determine the best registration method, based on seven signal-to-noise and image quality measures. Repeatability was assessed for no motion correction (Original) and the best performing method (Best) using Bland-Altman analysis. Lastly, the best motion correction method was compared to no motion correction on patient MRE data [pancreatic ductal adenocarcinoma (PDAC, n=5) and metabolic dysfunction-associated steatotic liver disease (MASLD) (n=1)]. Results: In silico experiments showed a deviation of shear wave speed (SWS) with simulated motion to the ground truth, which was (partially) resolved using motion correction. In healthy volunteers ranking resulted in the best motion correction method of monomodal registration using nine motion states, while no motion correction was ranked last. Limits of agreement were (-0.18, 0.14), and (-0.25, 0.18) m/s for Best and Original, respectively. Using motion correction in patients resulted in a significant increase in SWS in the pancreas (Original: 1.39±0.10 and Best: 1.50±0.17 m/s). After motion correction PDAC had a mean SWS of 1.56±0.27 m/s (Original: 1.42±0.25 m/s). The fibrotic liver mean SWS was 2.07±0.20 m/s (Original: 2.12±0.18 m/s). Conclusions: Motion correction in sagittal free-breathing abdominal MRE results in improved data quality, inversion precision, repeatability, and is feasible in patients.

13.
J Biophotonics ; : e202400016, 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38702959

RESUMEN

Optical coherence elastography (OCE) demonstrated impressive abilities for diagnosing tissue types/states using differences in their biomechanics. Usually, OCE visualizes tissue deformation induced by some additional stimulus (e.g., contact compression or auxiliary elastic-wave excitation). We propose a new variant of OCE with osmotically induced straining (OIS-OCE) and demonstrate its application to assess various stages of proteoglycan content degradation in cartilage. The information-bearing signatures in OIS-OCE are the magnitude and rate of strains caused by the application of osmotically active solutions onto the sample surface. OCE examination of the induced strains does not require special tissue preparation, the osmotic stimulation is highly reproducible, and strains are observed in noncontact mode. Several minutes suffice to obtain a conclusion. These features are promising for intraoperative method usage when express assessment of tissue state is required during surgical operations. The "waterfall" images demonstrate the development of cumulative osmotic strains in control and degraded cartilage samples.

14.
JSES Int ; 8(3): 577-581, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707569

RESUMEN

Background: The flexor pronator muscles (FPMs) have been thought as a dynamic stabilizer to protect the ulnar collateral ligament (UCL) from valgus stress during throwing motion. Thus, evaluation of the FPMs is important for preventing UCL injuries. Shear wave ultrasound elastography (SWE) is an imaging modality that quantifies tissue elasticity. The purpose of this study was to measure the tissue elasticities of healthy FPMs using SWE. Methods: We investigated 22 healthy men (mean age, 29 ± 6 years). The elasticities of the FPMs, including the pronator teres (PT), flexor digitorum superficialis (FDS), and flexor carpi ulnaris (FCU), were measured using SWE for each arm under two conditions: at rest (unloaded) and under valgus stress (loaded). The values obtained under different loading conditions were compared between both elbows. Results: The mean SWE values of the PT, FDS, and FCU for the dominant elbows were 22.4 ± 3.6, 22.8 ± 2.9, and 22.3 ± 3.4 kPa, respectively. The corresponding mean SWE values for the nondominant elbows were 24.2 ± 4.6, 23.1 ± 3.5, and 23.4 ± 3.5 kPa, respectively. The mean SWE values of the PT, FDS, and FCU at rest (unloaded) were 23.3 ± 4.2, 22.9 ± 3.2, and 22.9 ± 3.5 kPa, respectively. The corresponding mean SWE values under valgus stress (loaded) were 35.0 ± 6.2, 34.7 ± 5.3, and 31.9 ± 4.8 kPa, respectively. Conclusion: This noninvasive evaluation of the stiffness of the FPMs may provide clinically relevant data for the prevention of UCL injuries.

15.
Artículo en Inglés | MEDLINE | ID: mdl-38716213

RESUMEN

Background: Non-invasive tests (NITs) can be used to estimate the severity of fibrosis in patients with nonalcoholic fatty liver disease (NAFLD) but their diagnostic accuracy is variable. Hispanic patients are at increased risk of NAFLD and diabetes. We evaluate the diagnostic performance of the fibrosis index based on 4 factors (FIB-4) in a population of Hispanic patients who underwent vibration-controlled transient elastography (VCTE). Methods: A total of 1,524 patients underwent VCTE at University of California, Los Angeles from July 18, 2019 to June 7, 2022. Ultimately 110 patients were identified as Hispanic, with confirmed NAFLD. Sensitivity, specificity, positive predictive value and negative predictive value of FIB-4 threshold ≥1.3 were calculated. Logistic regression models were used to determine updated thresholds for patients with and without diabetes based on Youden's index. Results: Of the 110 patients, the majority (65%) were female. Prevalence of diabetes was higher in the group with clinically significant fibrosis (76% vs. 36%, P<0.001). Using a FIB-4 threshold ≥1.3 to predict clinically significant fibrosis (F2-F4 on VCTE), area under the receiver operating characteristic (AUROC) was 0.74. By incorporating diabetes status, AUROC was 0.81 when employing a FIB-4 threshold of ≥1.0 in patients with diabetes and ≥1.5 in patients without diabetes. Conclusions: Using a FIB-4 threshold of ≥1.0 in patients with diabetes and ≥1.5 in patients without diabetes improves the diagnostic performance of the test. The new FIB-4 including diabetes status will lead to improved screening in patients who are at risk of clinically significant fibrosis.

16.
Ultrasound Med Biol ; 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38714465

RESUMEN

OBJECTIVE: Ultrasound speckle tracking enables in vivo measurement of soft tissue deformation or strain, providing a non-invasive diagnostic tool to quantify tissue health. However, adoption into new fields is challenging since algorithms need to be tuned with gold-standard reference data that are expensive or impractical to acquire. Here, we present a novel optimization approach that only requires repeated measurements, which can be acquired for new applications where reference data might not be readily available or difficult to get hold of. METHODS: Soft tissue motion was captured using ultrasound for the medial collateral ligament (MCL) of three quasi-statically loaded porcine stifle joints, and medial ligamentous structures of a dynamically loaded human cadaveric knee joint. Using a training subset, custom speckle tracking algorithms were created for the porcine and human ligaments using surrogate optimization, which aimed to maximize repeatability by minimizing the normalized standard deviation of calculated strain maps for repeat measurements. An unseen test subset was then used to validate the tuned algorithms by comparing the ultrasound strains to digital image correlation (DIC) surface strains (porcine specimens) and length change values of the optically tracked ligament attachments (human specimens). RESULTS: After 1500 iterations, the optimization routine based on the porcine and human training data converged to similar values of normalized standard deviations of repeat strain maps (porcine: 0.19, human: 0.26). Ultrasound strains calculated for the independent test sets using the tuned algorithms closely matched the DIC measurements for the porcine quasi-static measurements (R > 0.99, RMSE < 0.59%) and the length change between the tracked ligament attachments for the dynamic human dataset (RMSE < 6.28%). Furthermore, strains in the medial ligamentous structures of the human specimen during flexion showed a strong correlation with anterior/posterior position on the ligaments (R > 0.91). CONCLUSION: Adjusting ultrasound speckle tracking algorithms using an optimization routine based on repeatability led to robust and reliable results with low RMSE for the medial ligamentous structures of the knee. This tool may be equally beneficial in other soft-tissue displacement or strain measurement applications and can assist in the development of novel ultrasonic diagnostic tools to assess soft tissue biomechanics.

17.
J Matern Fetal Neonatal Med ; 37(1): 2347954, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38714523

RESUMEN

BACKGROUND: A short cervix in the second trimester is known to increase the risk of preterm birth, which can be reduced with the administration of vaginal progesterone. However, some studies have suggested that a significant number of cases still experience preterm birth despite progesterone treatment. OBJECTIVE: This study was aimed to investigate the potential value of transvaginal cervical elasticity measured by E-Cervix as a predictor for spontaneous preterm birth (sPTB) in singleton pregnancies receiving progesterone treatment for a short cervix (CL ≤ 2.5 cm) diagnosed at 18 to 24 weeks' gestation. STUDY DESIGN: This prospective study was conducted at a single center premature high-risk clinic from January 2020 to July 2022. Singleton pregnancies with a short cervix at 18 to 24 weeks' gestation were enrolled. Cervical elastography using E-Cervix was performed, and maternal and neonatal demographic characteristics, cervical length (CL), elasticity contrast index (ECI), cervical hardness ratio, mean internal os strain (IOS), and mean external os strain (EOS) were compared before and after progesterone treatment in sPTB and term birth groups. Multivariate logistic regression was used to analyze the association between elasticity parameters and spontaneous preterm birth. The screening performance of CL and optimal cervical elasticity parameters in predicting sPTB was evaluated using receiver-operating characteristic (ROC) curve analysis. RESULTS: A total of 228 singleton pregnant women were included in the study, among which 26 (11.4%) had sPTB. There were no significant differences in maternal characteristics and gestational age at enrollment between women with and without sPTB. At the start of progesterone treatment, there were no significant differences in cervical elasticity parameters between the two groups. After two weeks of progesterone treatment, women who had sPTB showed significantly higher levels of ECI, IOS, EOS (p = 0.0108, 0.0001, 0.016), and lower hardness ratio (p = 0.011) compared to those who had a full-term birth. Cervical length did not show significant differences between the two groups, regardless of whether progesterone treatment was administered before or after. Among the post-treatment cervical elasticity parameters, IOS and EOS were associated with a 3.38-fold and 2.29-fold increase in the risk of sPTB before 37 weeks (p = 0.032, 0.047, respectively). The AUROC of the combined model including CL, IOS, and EOS (0.761, 95% CI0.589-0.833) was significantly higher than the AUROC of CL alone (0.618, 95% CI 0.359-0.876). At a fixed false-positive of 13%, the addition of IOS and EOS in the CL model increased sensitivity from 34.6% to 57.6%, PPV from 25.7% to 36.5%, and NPV from 91.1% to 94.1%. CONCLUSION: When assessing the risk of sPTB in singleton pregnancies with a short cervix receiving progesterone therapy, relying solely on cervical length is insufficient. It is crucial to also evaluate cervical stiffness, particularly the strain of the internal and external os, using cervical elastography.


Asunto(s)
Cuello del Útero , Diagnóstico por Imagen de Elasticidad , Nacimiento Prematuro , Progesterona , Humanos , Femenino , Embarazo , Progesterona/administración & dosificación , Nacimiento Prematuro/prevención & control , Adulto , Estudios Prospectivos , Cuello del Útero/diagnóstico por imagen , Cuello del Útero/efectos de los fármacos , Progestinas/administración & dosificación , Progestinas/uso terapéutico , Segundo Trimestre del Embarazo , Medición de Longitud Cervical , Edad Gestacional , Administración Intravaginal , Valor Predictivo de las Pruebas
18.
Pediatr Radiol ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717607

RESUMEN

BACKGROUND: Assessment of breast development by physical examination can be difficult in the early stages and in overweight girls. OBJECTIVE: To investigate ultrasonography (US) for evaluation of early breast development. MATERIALS AND METHODS: In a prospective study, 125 girls (age 7.1 ± 1.5 years) with breast development before 8 years underwent US breast staging, breast volume, and elastography, in addition to clinical/hormonal evaluation for precocious puberty. Accuracy of US for determining breast development and predicting progression to central precocious puberty was investigated. RESULTS: Physical examination revealed glandular breast enlargement in 100 and predominantly lipomastia in 25. Breast US in the former confirmed glandular breast development in 92 (group 1, physical examination and US positive), but not in 8 (group 2, physical examination positive, US negative). Comparison of the two groups demonstrated lower Tanner and US staging, bone age/chronological age, basal luteinizing hormone (LH), breast volume, and uterine volume in group 2. In the 25 lipomastia patients, US demonstrated no breast tissue in 19 (group 3, physical examination and US negative), but US stage ≥ II in 6 (group 4, physical examination negative, US positive) without differences in clinical parameters. After follow-up of 19.8 ± 4.2 months, 46/125 subjects were diagnosed with precocious puberty. US stage, total breast volume, and shear-wave speeds were significantly higher in these 46 patients. Multivariate analyses demonstrated breast volume > 3.4 cc had odds ratio of 11.0, sensitivity of 62%, and specificity of 89, in predicting progression to precocious puberty, being second only to stimulated LH for all variables. CONCLUSION: Breast US is a useful predictive tool for diagnosis of precocious puberty in girls. Higher US stages and higher breast volume on US increased the likelihood of eventual diagnosis of precocious puberty.

19.
Front Bioeng Biotechnol ; 12: 1378031, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784765

RESUMEN

Background: Abnormal, excessive, and repetitive knee load is a critical risk factor for osteoarthritis (OA). The gastrocnemius muscle-tendon unit (MTU) interacts with foot biomechanics and is vital in cushioning the knee load. Abnormal gastrocnemius activation and plantar pressure during walking in patients with knee OA may negatively affect gastrocnemius MTU stiffness, increasing knee load. Few studies investigated the relationship between gastrocnemius MTU stiffness and plantar pressure. This study aimed to evaluate the changes in gastrocnemius MTU stiffness in patients with knee OA and their correlations with plantar pressure and clinical symptoms. Methods: Thirty women patients with unilateral knee OA and 30 healthy women participants were recruited. Shear wave elastography was used to quantify gastrocnemius MTU stiffness in ankle resting and anatomical 0° positions, defined as natural and neutral positions in this study. A plantar pressure analysis system was used to collect the plantar pressure parameters on the symptomatic side in patients with knee OA. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Visual Analogue Scale (VAS) scores were used to measure the severity of clinical symptoms. Results: Medial and lateral gastrocnemius (MG and LG) stiffness on both the asymptomatic and symptomatic sides in patients with knee OA was increased compared with that in healthy participants. The MG and LG optimal cutoff stiffness in the natural position was 15.73 kPa and 14.25 kPa, respectively. The optimal cutoff stiffness in the neutral position was 36.32 kPa and 25.43 kPa, respectively, with excellent sensitivity and specificity. The MG and LG stiffness were positively correlated with the percentages of anterior and medial plantar pressure and negatively correlated with the length of pressure center path. The LG and MG were significantly correlated with WOMAC and VAS scores. Conclusion: Patients with knee OA have increased gastrocnemius muscle stiffness, closely related to plantar pressure and clinical symptoms. Monitoring the gastrocnemius muscle in patients with knee OA can provide an essential basis for its prevention and treatment.

20.
Dig Liver Dis ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38744558

RESUMEN

BACKGROUND: Magnetic resonance elastography (MRE) is recognized as the most precise imaging technology for assessing liver fibrosis in individuals with metabolic dysfunction-associated steatotic liver disease (MASLD). We aimed to investigate the clinical factors and pathological characteristics that may impact LSM in MASLD patients. METHODS: This cross-sectional study recruited 124 patients who concurrently performed MRE, MRI-PDFF, and biopsy-proven MASLD. Linear regression models, Spearman's correlation, and subgroup analysis were employed to identify the variables affecting LSM. RESULTS: The AUROC (95 % CI) of MRE for diagnosing fibrosis stage ≥ 1, 2, 3, and 4 was 0.80 (0.70-0.90), 0.76 (0.66-0.85), 0.92 (0.86-0.99), and 0.99 (0.99-1.00), with corresponding cutoffs of 2.56, 2.88, 3.35, and 4.76 kPa, respectively. Multivariate analyses revealed that AST was the only independent clinical variable significantly correlated with LSM. Furthermore, LSM exhibited a notable association with the grade of lobular inflammation and hepatocellular ballooning. Subgroup analysis showed that when AST ≥ 2 ULN or inflammation grade ≥ 2, LSM of patients with early fibrosis stages showed a slight but significant increase. CONCLUSION: MRE demonstrates significant diagnostic accuracy in predicting liver fibrosis stages for MASLD patients, especially for advanced liver fibrosis and cirrhosis. However, elevated AST and the severity of liver inflammation may impact its accuracy in staging early liver fibrosis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...