Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.242
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39077549

RESUMEN

A 67-year-old man visited our hospital complaining of dark-colored urine and upper abdominal pain. Magnetic resonance cholangiopancreatography showed stricture of the distal bile duct, and contrast-enhanced computed tomography showed irregular thickening of the distal bile duct wall. However, no enlarged lymph nodes, pancreatic tumors, or other neoplastic lesions were apparent around the bile duct. Endoscopic ultrasonography and intraductal ultrasonography showed irregular thickening of the inner hypoechoic layer without the disappearance of the innermost thin hyperechoic layer. On the basis of these findings, we considered that the bile duct lesion was of non-epithelial origin. Thus, we repeatedly performed bile duct biopsies from the same site under fluoroscopy to obtain a sample of the submucosal tissue. The pathological diagnosis was diffuse large B-cell lymphoma, and the patient received systemic chemotherapy (rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone). After six courses of rituximab, cyclophosphamide, doxorubicin, vincristine, and prednisone, positron emission tomography-computed tomography showed the disappearance of 18-fluorodeoxyglucose uptake in the bile duct and endoscopic retrograde cholangiography showed improvement of the bile duct stricture. Endoscopic findings and repeated biopsies were useful in making the diagnosis of primary biliary diffuse large B-cell lymphoma.

2.
Dig Endosc ; 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39364550

RESUMEN

Interventional endoscopic ultrasonography/endosongraphy (I-EUS) procedures have rapidly evolved since their introduction three decades ago; however, the classification and terminology for these procedures remain unstandardized. To address this, the Subcommittee for Terminology of I-EUS in the Japan Gastroenterological Endoscopy Society was established to define classifications and a glossary of I-EUS terms. They categorized I-EUS procedures into five types based on purpose and method: (i) EUS-guided sampling; (ii) EUS-guided through-the-needle examination; (iii) EUS-guided drainage/anastomosis (EUS-D/A); (iv) trans-endosonographically/EUS-guided created route (ESCR) procedures; and (v) EUS-guided delivery. EUS-guided sampling includes tissue acquisition and fluid sampling, classified by needle type into fine needle aspiration and fine needle biopsy. Through-the-needle examinations include imaging, measurements, and biopsies. EUS-D/A includes organ drainage/anastomosis, fluid collection drainage, and digestive tract anastomosis. In the EUS-D/A route, "anastomosis" is used for organ-to-organ procedures, whereas "tract" is for fluid drainage. ESCR is a newly proposed term for procedures via anastomosis or tract, such as endoscopic necrosectomy and EUS-guided antegrade stenting. The term "trans-luminal drainage/anastomosis stent" is used for stents that maintain the ESCR rather than treating strictures. EUS-guided delivery involves the delivery of substances, such as fluids, drugs, medical devices, and energy. This proposed categorization and terminology aimed to clarify I-EUS procedures and will require updates as new techniques and concepts emerge.

3.
Surg Endosc ; 2024 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-39317905

RESUMEN

BACKGROUND: Malignant Distal Biliary Obstruction (MBDO) is a common event occurring along the natural history of both pancreatic cancer and cholangiocarcinoma. Epidemiological and biological features make MBDO one of the key elements of the clinical management of patients suffering for of pancreatic cancer or cholangiocarcinoma. The development of dedicated biliary lumen-apposing metal stents (LAMS) is changing the clinical work up of patients with MBDO. i-EUS is an Italian network of clinicians and scientists with a special interest in biliopancreatic endoscopy, EUS in particular. METHODS: The scientific methodology was chosen in line with international guidance and in a fashion similar to those applied by broader scientific associations. PICO questions were elaborated and subsequently voted by a broad panel of experts within a simplified Delphi process. RESULTS AND CONCLUSIONS: The manuscripts describes the results of a consensus conference organized by i-EUS with the aim of providing an evidence based-guidance for the appropriate use of the techniques in patients with MBDO.

4.
Sci Rep ; 14(1): 22453, 2024 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-39341878

RESUMEN

Endoscopic ultrasound-guided fine needle biopsy is an effective method for obtaining tissue samples from various organs; however, challenges such as inadequate specimens persist. This study compared a newly designed Tricore needle with a Franseen needle for endoscopic ultrasound-guided fine needle biopsy of porcine liver. Both needles were tested on four male Yorkshire pigs. Specimens were obtained with an 100% (36/36) success rate with no procedure-related adverse effects. The Tricore needle experienced significantly less resistance during puncture than Franseen needle (3.83 vs. 5.97 N, P < 0.001) and better ultrasound visibility (168.97 vs. 125.04, P = 0.004). The Tricore needle also achieved faster specimen acquisition time (48.94 vs. 59.90 s, P = 0.038), larger total specimen area (6.67 vs. 4.68 mm2, P = 0.049), fewer fragments (23.94 vs. 31.94, P = 0.190), lager fragment area (0.28 vs. 0.15 mm2, P < 0.001), and more the number of complete portal tracts (15.44 vs. 9.33, P = 0.017) compared to the Franseen needle. The newly designed Tricore needle showed enhanced procedural performance and specimen quantity and quality compared to commercially available Franseen needle. Although further clinical studies are required, the Tricore needle may represent a favorable option for endoscopic ultrasound-guided fine-needle biopsy procedures.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Hígado , Agujas , Animales , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos , Porcinos , Hígado/patología , Hígado/diagnóstico por imagen , Masculino , Diseño de Equipo
5.
Cureus ; 16(8): e66983, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39280535

RESUMEN

We present the case of an 82-year-old female with obstructive jaundice secondary to a malignant distal biliary stricture. Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) was performed. The presence of a giant hiatal hernia induced dynamic liver movement during respiration, leading to unstable scope positioning. Despite the successful placement of a long, partially covered metal stent from the left intrahepatic bile duct to the intra-abdominal stomach, computed tomography performed three days later revealed free air and an increased distance between the liver and stomach. A subsequent endoscopy confirmed impending stent migration into the abdominal cavity, necessitating the insertion of an additional metal stent through the existing stent's mesh. The presence of a giant hiatal hernia may be considered a relative contraindication for EUS-HGS due to dynamic movements of the stomach and liver during respiration, which can cause stent migration, increased air leakage, and difficulty in establishing a stable fistula between these organs.

6.
Endosc Int Open ; 12(9): E1015-E1022, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39263557

RESUMEN

Background and study aims The relative procedural performance of needles for endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/B) is unclear. The present study therefore compared six types of 22-gauge FNA/B needles using a bench simulator. Methods Resistance forces during needle puncture and removal, needle tip damage before and after procedure, leakage after puncture of mucinous cyst models, the shape of the puncture surface at the puncture site, amounts of samples extracted, ranges of needle deflection angles, and needle deformation after multiple procedures were compared using six types of needles. Results Maximum resistance forces during puncture and removal were highest for ProCore needles and lowest for Expect needles. None of the needles had damage after puncturing. SharkCore needles showed the highest amount of leakage, whereas FNA needles showed no leakage. The puncture tracts of FNA needles remained in the form of a flap at the puncture site, whereas FNB needles broke off the target material creating a hole. The target material removed was supplemented within the puncture needle. TopGain needles produced significantly larger samples than ProCore, EZShot3 Plus, and Expect needles. FNB needles produced larger and more core samples than FNA needles. EZShot3 Plus needles had the highest range of needle deflection angle using an elevator device and the lowest needle deformation after 20 punctures at full endoscopic angle and a full elevator. Conclusions The performance of the six needles differed in various ways. Understanding the characteristics of each needle may allow for selection of the appropriate needle for each situation.

7.
J Clin Med ; 13(17)2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39274210

RESUMEN

Background and Aims: Despite its relatively low incidence rate compared to others, pancreatic cancer has a poor prognosis owing to its late detection and poor response to systemic chemotherapy. Because the effectiveness of chemotherapy is still restricted, the need for locoregional treatment is increasing. Cryoablation is an effective and minimally invasive treatment for some cancers, but its efficiency in pancreatic cancer is limited. Despite recent reports about promising outcomes, the optimal method and conditions of treatment are not known. In this preliminary study, we aimed to develop a cryoablation needle which can control the ablated area considering application through endoscopic ultrasonography. Methods: Here, we used a novel cryoneedle cooling system which can adjust the ablation range based on a liquid carbon dioxide refrigerant. Applied to the livers of swine, the cryoablation needle rapidly reached -60 °C within 30 s and cryoablation was performed for approximately 240 s. Based on the distance and depth, we collected real-time temperature data during the procedure. To compare the extent of cell death over time, tissue samples were collected hourly from 3 to 6 h after the procedure. Results: Approximately 4-5 mm of tissue was ablated via cryoablation, and cell death progressed over time after cryoablation. Moreover, the ablated lesions could be regulated using an insulating agent on the needle. Conclusions: This preliminary study on a novel surgical cooling needle system compatible with endoscopic ultrasound for cryoablation-based pancreatic cancer treatment confirmed the efficacy of cryoablation and identified the conditions necessary to induce necrosis. Additionally, this study evaluated the effectiveness of the insulation component of the system in protecting normal cells and assessed the extent of necrosis over time after the procedure.

9.
Endosc Int Open ; 12(9): E1075-E1084, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39285859

RESUMEN

Background and study aims The safety of endoscopic submucosal dissection (ESD) has been reported, and the risk of lymph node metastasis is low for colorectal cancer if depth of invasion is the only non-curative factor on histological evaluation. ESD is increasingly performed even if submucosal (SM) invasion is suspected. However, reports about endoscopic findings for the criteria to predict ESD resectability remain limited. Endoscopic ultrasound (EUS) can directly visualize the tomographic image of the gastrointestinal wall and may help predict ESD resectability. Therefore, we investigated the possibility of predicting ESD resectability using EUS. Patients and methods We compared the association between EUS findings and pathological results for gastric or colorectal lesions with suspected SM invasion using white light endoscopy between June 2020 and January 2023. EUS findings were grouped based on the status of the underlying the tumor, as follows: Type I, submucosal layer was observed with reproducibility; Type II, submucosal layer not fully visible; and Type III, submucosal layer disrupted and muscularis propria (MP) layer thickened. Results Forty-one gastric cancer and 22 colorectal cancer cases were analyzed. The proportions of pathological VM0 (no tumor exposed on any vertical margin) for ESD-resected specimens were 89% and 33% for Type I and II, respectively, ( P ≤ 0.01). The proportions of cancer involving MP or deeper were significantly higher for Type II/III than for Type I (41% vs 0%, P ≤ 0.01). Conclusions EUS may have an important role in predicting ESD resectability of gastric and colorectal cancers suspected of having SM invasion.

10.
Endosc Int Open ; 12(9): E1065-E1074, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39285860

RESUMEN

The first Asia-Pacific consensus recommendations for endoscopic and interventional management of hilar cholangiocarcinoma were published in 2013. Since then, new evidence on the role of endoscopy for management of malignant hilar biliary obstruction (MHBO) has emerged. To update the recommendation, we reviewed the literature using a PICO (population/intervention/comparison/outcomes) framework and created consensus statements. The expert panel voted anonymously using the modified Delphi method and all final statements were evaluated for the quality of evidence and strength of recommendation. The important points with inadequate supporting evidence were classified as key concepts. There were seven statements and five key concepts that reached consensus. The statements and key concepts dealt with multiple aspects of endoscopy-based management in MHBO starting from diagnosis, strategies and options for biliary drainage, management of recurrent biliary obstruction, management of cholecystitis after biliary stenting, and adjunctive treatment before stenting. Although the recommendations may assist physicians in planning the treatment for MHBO patients, they should not replace the decision of a multidisciplinary team in the management of individual patients.

11.
World J Gastrointest Surg ; 16(7): 2351-2357, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39087111

RESUMEN

BACKGROUND: Extragastric lesions are typically not misdiagnosed as gastric submucosal tumor (SMT). However, we encountered two rare cases where extrinsic lesions were misdiagnosed as gastric SMTs. CASE SUMMARY: We describe two cases of gastric SMT-like protrusions initially misdiagnosed as gastric SMTs by the abdominal contrast-enhanced computed tomography (CT) and endoscopic ultrasound (EUS). Based on the CT and EUS findings, the patients underwent gastroscopy; however, no tumor was identified after incising the gastric wall. Subsequent surgical exploration revealed no gastric lesions in both patients, but a mass was found in the left triangular ligament of the liver. The patients underwent laparoscopic tumor resection, and the postoperative diagnosis was hepatic hemangiomas. CONCLUSION: During EUS procedures, scanning across different layers and at varying degrees of gastric cavity distension, coupled with meticulous image analysis, has the potential to mitigate the likelihood of such misdiagnoses.

12.
Dig Endosc ; 2024 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-39129171

RESUMEN

OBJECTIVES: Detective flow imaging endoscopic ultrasonography (DFI-EUS) is a recent imaging modality developed for detecting fine vessels without the need for ultrasound contrast agents. The aim of the present study was to evaluate the utility of DFI-EUS for solid pancreatic lesions and to compare the diagnostic ability for pancreatic cancer (PC) between DFI-EUS, directional power Doppler (eFLOW) EUS, and contrast-enhanced harmonic (CH)-EUS. METHODS: Patients with a pancreatic lesion who underwent DFI-EUS, eFLOW-EUS, and CH-EUS between March 2019 and November 2023 were retrospectively enrolled. Final diagnoses were confirmed by pathologic examination of EUS-guided tissue acquisition and/or resected specimens. Lesions were categorized into the three patterns of poor, mild, and rich vascularity on DFI-EUS and eFLOW-EUS, and hypo-, iso-, and hypervascular on CH-EUS. PC was defined as a poor pattern on DFI-EUS and eFLOW-EUS, and a hypovascular pattern on CH-EUS. RESULTS: The final diagnoses of 90 examined tumors were PC (n = 57), inflammatory mass (n = 6), autoimmune pancreatitis (n = 13), neuroendocrine tumor (n = 9), and others (n = 5). The sensitivity, specificity, and accuracy for diagnosis of PC were 93%, 82%, and 88%, respectively, on DFI-EUS, 97%, 42%, and 77% on eFLOW-EUS, and 95%, 89%, and 92% on CH-EUS. The accuracy of DFI-EUS was significantly superior to eFLOW-EUS (P = 0.005), but no significant difference was found between DFI-EUS and CH-EUS. CONCLUSION: DFI-EUS is more sensitive for depicting vasculature than eFLOW-EUS, and has higher diagnostic sensitivity for PC. Evaluation of vascularity on DFI-EUS is useful for the differential diagnosis of pancreatic lesions without the need for intravenous contrast agent.

14.
Endosc Int Open ; 12(8): E962-E967, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39184061

RESUMEN

Background and study aims Direct endoscopic necrosectomy (DEN) represents the first-line treatment for walled-off necrosis (WON). However, DEN has a non-negligible rate of overall adverse events (AE) and is time-consuming due to the lack of dedicated devices. This pilot study was designed to evaluate the feasibility and safety of a novel dedicated device for DEN named Necrolit. Patients and methods In this multicenter retrospective analysis,16 patients with WON who underwent DEN using Necrolit were compared with a control group treated with non-dedicated devices. Technical success, AEs, clinical success, number of procedures per patient, procedure time, and length of hospital stay were evaluated. Necrolit technical performance indicators were also studied. Results Technical success was obtained in all patients in both groups. In the Necrolit group, the overall AE rate was 10.1% vs. 15.9% in the control group. Clinical success was 100% in the Necrolit group vs. 81.3% in the control group. Patients treated with Necrolit underwent a slightly lower mean number of procedures (4.1 ± 2.3 vs. 5.1 ± 1.9) with comparable mean procedure time (67.8 ± 39 minutes vs. 70.1 ± 32.6 minutes). Mean duration of hospital stay was 39.4 days (± 30.9) in the Necrolit group vs. 43 days (± 29.4) in the control group. Device-related technical performance was rated positively. Conclusions DEN with Necrolit appears feasible and safe.

15.
Endosc Int Open ; 12(8): E998-E1005, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39184062

RESUMEN

Background and study aims Lymph node (LN) involvement is a poor prognostic factor for patients with intrahepatic cholangiocarcinoma (iCCA). The aim of this study was to evaluate the yield and impact on clinical decision making of endoscopic ultrasound with tissue acquisition (EUS-TA) of LNs in patients with potentially resectable iCCA. Patients and methods In this multicenter cohort study, patients with potentially resectable iCCA and preoperative EUS between 2010 and 2020 were retrospectively included. The impact of EUS-TA was defined as the percentage of patients who did not undergo surgical exploration due to pathologically confirmed positive LNs found with EUS-TA. Results A total of 56 patients underwent EUS, with 91% of patients to target suspicious LNs on imaging. EUS-TA of LNs confirmed malignancy in 21 LNs among 19 patients (34%). In 17 patients (30%), surgical exploration was withheld due to nodal involvement. Finally, 24 patients (43%) underwent surgical exploration among whom positive regional LNs were identified in six patients (25%). Conclusions In patients with potentially resectable iCCA and suspicious LNs on cross-sectional imaging, EUS-TA confirmed LN involvement in 30% of patients. Surgical exploration was withheld mostly because of extraregional LN involvement and regional LN involvement in patients with high surgical risk.

16.
Endosc Int Open ; 12(8): E955-E961, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39131731

RESUMEN

Background and study aims To insert the metal stent delivery system (8.5F) during interventional endoscopic ultrasound (I-EUS), several dilation steps are needed, which may be related to increased bile leakage from a fistula. There have been no definitive studies of dilation force. The aim of the present study was to evaluate dilation force during I-EUS using several dilation devices. Methods In the present study, seven dilation devices were evaluated including bougie dilators such as a straight-shaped dilator (the ES dilator, Soehendra dilator, a standard ERCP catheter) a screw-shaped dilator (Tornus ES, Soehendra stent retriever), and a 4-mm balloon catheter (REN biliary balloon catheter, Hurricane RX). The diameter of each dilator and dilation force were measured. Results Of the bougie dilators, the dilation force of the ES dilator was the highest (0.908±0.035 kg). Of the balloon catheters, the dilation force of the Hurricane RX (3.261±0.024 kg) was slightly higher than that of the REN (3.159±0.072 kg). Of the bougie dilators, although the diameter of the ES dilator was not larger than that of the Tornus ES, the dilation force was stronger. Similarly, the diameter of the Soehendra stent retriever was greater than that of the ERCP catheter or Soehendra dilator and the dilation force was lower. Conclusions Compared with bougie dilators, balloon catheters have stronger dilation force according to our experimental study. The present results should be evaluated in clinical trials.

17.
Heliyon ; 10(14): e34344, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39130461

RESUMEN

Objectives: This research aimed to retrospectively construct and authenticate ultrasomics models using endoscopic ultrasonography (EUS) images for forecasting the pathological grading of pancreatic neuroendocrine tumors (PNETs). Methods: After confirmation through pathological examination, a retrospective analysis of 79 patients was conducted, including 49 with grade 1 PNETs and 30 with grade 2/3 PNETs. These patients were randomized to the training or test cohort in a 6:4 proportion. The least absolute shrinkage and selection operator (LASSO) algorithm was used to reduce the dimensionality of ultrasomics features derived from standard EUS images. These nonzero coefficient features were retained and applied to construct prediction models via eight machine-learning algorithms. The optimum ulstrasomics model was determined, followed by creating and evaluating a nomogram. Results: Ultrasomics features of 107 were extracted, and only those with coefficients greater than zero were retained. The XGboost ultrasomics model performed exceptionally well, achieving AUCs of 0.987 and 0.781 in the training and test cohorts, respectively. Furthermore, an effective nomogram was developed and visually represented. Finally, the calibration curves, decision curve analysis (DCA) plots, and clinical impact curve (CIC) displayed in the ulstrasomics model and nomogram demonstrated high accuracy. They provided significant net benefits for clinical decision-making. Conclusions: A novel ulstrasomics model and nomogram were created and certified to predict the pathological grading of PNETs using EUS images. This study has the potential to provide valuable insights that improve the clinical applicability and efficacy of EUS in predicting the grading of PNETs.

18.
Zhonghua Gan Zang Bing Za Zhi ; 32(6): 572-576, 2024 Jun 20.
Artículo en Chino | MEDLINE | ID: mdl-38964902

RESUMEN

Liver biopsy is an important means of clinical diagnosis and treatment of liver diseases, but it is not easily accepted by patients because of its invasiveness. The most commonly employed liver biopsy approaches are percutaneous or transjugular. Endoscopic ultrasound-guided liver biopsy (EUS-LB), a newly emerging transjugular technique, has been widely studied and applied in recent years, but its application in China is less common. The EUS-LB has the advantages of high safety and comfort, simultaneous sampling of both liver lobes, and adequate sampling volume; however, it also has the disadvantages of high requirements for hardware, operators, and cost. This article reviews the clinical application of EUS-LB in accordance with pertinent research findings from recent years and discusses its advantages, disadvantages, and implementation feasibility.


Asunto(s)
Endosonografía , Hígado , Humanos , Hígado/patología , Hígado/diagnóstico por imagen , Endosonografía/métodos , Hepatopatías/patología , Hepatopatías/diagnóstico por imagen , Hepatopatías/diagnóstico
19.
Clin Endosc ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38965710

RESUMEN

Eosinophilic esophagitis (EoE) is a chronic immune-mediated disease involving inflammation of the esophagus. Endoscopy is essential in the diagnosis and treatment of EoE and shows typical findings, including esophageal edema, rings, exudates, furrows, and stenosis. However, studies involving pediatric and adult patients with EoE suggest that even a normally appearing esophagus can be diagnosed as EoE by endoscopic biopsy. Therefore, in patients with suspected EoE, biopsy samples should be obtained from the esophagus regardless of endoscopic appearance. Moreover, follow-up endoscopies with biopsy after therapy initiation are usually recommended to assess response. Although previous reports of endoscopic ultrasonography findings in patients with EoE have shown diffuse thickening of the esophageal wall, including lamina propria, submucosa, and muscularis propria, its role in EoE remains uncertain and requires further investigation. Endoscopic dilation or bougienage is a safe and effective procedure that can be used in combination with medical and/or dietary elimination therapy in patients with esophageal stricture for the management of dysphagia and to prevent its recurrence.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA