1.
Phys Med Biol ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38981588

RESUMEN

OBJECTIVE: Clinical applications of FLASH radiotherapy require formulas to describe how the FLASH radiation features and other related factors determine the FLASH effect. Mathematical analysis of the models can connect the theoretical hypotheses with the radiobiological effect, which provides the foundation for establishing clinical application models. Moreover, experimental and clinical data can be used to explore the key factors through mathematical analysis. Approach: We abstract the complex models of the oxygen depletion hypothesis and radical recombination-antioxidants hypothesis into concise mathematical equations. The equations are solved to analyze how the radiation features and other factors influence the FLASH effect. Then we propose methodologies for determining the parameters in the models and utilizing the models to predict the FLASH effect. Main results: The formulas linking the physical, chemical and biological factors to the FLASH effect are obtained through mathematical derivation of the equation. The analysis indicates that the initial oxygen concentration, radiolytic oxygen consumption and oxygen recovery are key factors for the oxygen depletion hypothesis and that the level of antioxidants is the key factor for the radical recombination-antioxidants hypothesis. According to the model derivations and analysis, the methodologies for determining parameters and predicting the FLASH effect are proposed: the criteria for data filtration; the strategy of hybrid FLASH and conventional dose rate (CONV) irradiation to ensure the acquisition of effective experimental data across a wide dose range; pipelines of fitting parameters and predicting the FLASH effect. Significance: This study establishes the quantitative relationship between the FLASH effect and key factors. The derived formulas can be used to calculate the FLASH effect in future clinical FLASH radiotherapy. The proposed methodologies guide to obtain sufficient high-quality datasets and utilize them to predict FLASH effect. Furthermore, this study indicates the key factors of FLASH effect and offers clues to further explore the FLASH mechanism.

2.
Materials (Basel) ; 17(13)2024 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-38998435

RESUMEN

This study investigates how scattering foil materials and sampling holder placement affect electron energy distribution in electron beams from a modified medical linear accelerator for FLASH radiotherapy. We analyze electron energy spectra at various positions-ionization chamber, mirror, and jaw-to evaluate the impact of Cu, Pb-Cu, Pb, and Ta foils. Our findings show that close proximity to the source intensifies the dependence of electron energy distribution on foil material, enabling precise beam control through material selection. Monte Carlo simulations are effective for designing foils to achieve desired energy distributions. Moving the sampling holder farther from the source reduces foil material influence, promoting more uniform energy spreads, particularly in the 0.5-10 MeV range for 12 MeV electron beams. These insights emphasize the critical role of tailored material selection and sampling holder positioning in optimizing electron energy distribution and fluence intensity for FLASH radiotherapy research, benefiting both experimental design and clinical applications.

3.
Biomolecules ; 14(7)2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-39062469

RESUMEN

Radiotherapy is an important treatment for many unresectable advanced malignant tumors, and radiotherapy-associated inflammatory reactions to radiation and other toxic side effects are significant reasons which reduce the quality of life and survival of patients. FLASH-radiotherapy (FLASH-RT), a prominent topic in recent radiation therapy research, is an ultra-high dose rate treatment known for significantly reducing therapy time while effectively targeting tumors. This approach minimizes radiation side effects on at-risk organs and maximally protects surrounding healthy tissues. Despite decades of preclinical exploration and some notable achievements, the mechanisms behind FLASH effects remain debated. Standardization is still required for the type of FLASH-RT rays and dose patterns. This review addresses the current state of FLASH-RT research, summarizing the biological mechanisms behind the FLASH effect. Additionally, it examines the impact of FLASH-RT on immune cells, cytokines, and the tumor immune microenvironment. Lastly, this review will discuss beam characteristics, potential clinical applications, and the relevance and applicability of FLASH-RT in treating advanced cancers.


Asunto(s)
Neoplasias , Microambiente Tumoral , Humanos , Neoplasias/radioterapia , Microambiente Tumoral/efectos de la radiación , Animales , Radioterapia/métodos , Radioterapia/efectos adversos , Citocinas/metabolismo
4.
Sci Rep ; 14(1): 14803, 2024 06 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926450

RESUMEN

Ultra-high dose rate (UHDR) irradiation has been shown to have a sparing effect on healthy tissue, an effect known as 'FLASH'. This effect has been studied across several radiation modalities, including photons, protons and clinical energy electrons, however, very little data is available for the effect of FLASH with Very High Energy Electrons (VHEE). pBR322 plasmid DNA was used as a biological model to measure DNA damage in response to Very High Energy Electron (VHEE) irradiation at conventional (0.08 Gy/s), intermediate (96 Gy/s) and ultra-high dose rates (UHDR, (2 × 109 Gy/s) at the CERN Linear Electron Accelerator (CLEAR) user facility. UHDRs were used to determine if the biological FLASH effect could be measured in the plasmid model, within a hydroxyl scavenging environment. Two different concentrations of the hydroxyl radical scavenger Tris were used in the plasmid environment to alter the proportions of indirect damage, and to replicate a cellular scavenging capacity. Indirect damage refers to the interaction of ionising radiation with molecules and species to generate reactive species which can then attack DNA. UHDR irradiated plasmid was shown to have significantly reduced amounts of damage in comparison to conventionally irradiated, where single strand breaks (SSBs) was used as the biological endpoint. This was the case for both hydroxyl scavenging capacities. A reduced electron energy within the VHEE range was also determined to increase the DNA damage to pBR322 plasmid. Results indicate that the pBR322 plasmid model can be successfully used to explore and test the effect of UHDR regimes on DNA damage. This is the first study to report FLASH sparing with VHEE, with induced damage to pBR322 plasmid DNA as the biological endpoint. UHDR irradiated plasmid had reduced amounts of DNA single-strand breaks (SSBs) in comparison with conventional dose rates. The magnitude of the FLASH sparing was a 27% reduction in SSB frequency in a 10 mM Tris environment and a 16% reduction in a 100 mM Tris environment.


Asunto(s)
Daño del ADN , Electrones , Plásmidos , Plásmidos/genética , Relación Dosis-Respuesta en la Radiación , Humanos , Aceleradores de Partículas , Roturas del ADN de Cadena Simple/efectos de la radiación
5.
Radiother Oncol ; 198: 110404, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38942121

RESUMEN

PURPOSE: To investigate quality assurance (QA) techniques for in vivo dosimetry and establish its routine uses for proton FLASH small animal experiments with a saturated monitor chamber. METHODS AND MATERIALS: 227 mice were irradiated at FLASH or conventional (CONV) dose rates with a 250 MeV FLASH-capable proton beamline using pencil beam scanning to characterize the proton FLASH effect on abdominal irradiation and examining various endpoints. A 2D strip ionization chamber array (SICA) detector was positioned upstream of collimation and used for in vivo dose monitoring during irradiation. Before each irradiation series, SICA signal was correlated with the isocenter dose at each delivered dose rate. Dose, dose rate, and 2D dose distribution for each mouse were monitored with the SICA detector. RESULTS: Calibration curves between the upstream SICA detector signal and the delivered dose at isocenter had good linearity with minimal R2 values of 0.991 (FLASH) and 0.985 (CONV), and slopes were consistent for each modality. After reassigning mice, standard deviations were less than 1.85 % (FLASH) and 0.83 % (CONV) for all dose levels, with no individual subject dose falling outside a ± 3.6 % range of the designated dose. FLASH fields had a field-averaged dose rate of 79.0 ± 0.8 Gy/s and mean local average dose rate of 160.6 ± 3.0 Gy/s. In vivo dosimetry allowed for the accurate detection of variation between the delivered and the planned dose. CONCLUSION: In vivo dosimetry benefits FLASH experiments through enabling real-time dose and dose rate monitoring allowing mouse cohort regrouping when beam fluctuation causes delivered dose to vary from planned dose.

6.
Phys Med ; 121: 103360, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692114

RESUMEN

This paper reports the development of dosimeters based on plastic scintillating fibers imaged by a charge-coupled device camera, and their performance evaluation through irradiations with the electron Flash research accelerator located at the Centro Pisano Flash Radiotherapy. The dosimeter prototypes were composed of a piece of plastic scintillating fiber optically coupled to a clear optical fiber which transported the scintillation signal to the readout systems (an imaging system and a photodiode). The following properties were tested: linearity, capability to reconstruct the percentage depth dose curve in solid water and to sample in time the single beam pulse. The stem effect contribution was evaluated with three methods, and a proof-of-concept one-dimensional array was developed and tested for online beam profiling. Results show linearity up to 10 Gy per pulse, and good capability to reconstruct both the timing and spatial profiles of the beam, thus suggesting that plastic scintillating fibers may be good candidates for low-energy electron Flash dosimetry.


Asunto(s)
Electrones , Plásticos , Dosímetros de Radiación , Dosificación Radioterapéutica , Conteo por Cintilación , Electrones/uso terapéutico , Conteo por Cintilación/instrumentación , Radiometría/instrumentación
7.
Med Phys ; 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38772134

RESUMEN

BACKGROUND: The extremely fast delivery of doses with ultra high dose rate (UHDR) beams necessitates the investigation of novel approaches for real-time dosimetry and beam monitoring. This aspect is fundamental in the perspective of the clinical application of FLASH radiotherapy (FLASH-RT), as conventional dosimeters tend to saturate at such extreme dose rates. PURPOSE: This study aims to experimentally characterize newly developed silicon carbide (SiC) detectors of various active volumes at UHDRs and systematically assesses their response to establish their suitability for dosimetry in FLASH-RT. METHODS: SiC PiN junction detectors, recently realized and provided by STLab company, with different active areas (ranging from 4.5 to 10 mm2) and thicknesses (10-20 µm), were irradiated using 9 MeV UHDR pulsed electron beams accelerated by the ElectronFLASH linac at the Centro Pisano for FLASH Radiotherapy (CPFR). The linearity of the SiC response as a function of the delivered dose per pulse (DPP), which in turn corresponds to a specific instantaneous dose rate, was studied under various experimental conditions by measuring the produced charge within the SiC active layer with an electrometer. Due to the extremely high peak currents, an external customized electronic RC circuit was built and used in conjunction with the electrometer to avoid saturation. RESULTS: The study revealed a linear response for the different SiC detectors employed up to 21 Gy/pulse for SiC detectors with 4.5 mm2/10 µm active area and thickness. These values correspond to a maximum instantaneous dose rate of 5.5 MGy/s and are indicative of the maximum achievable monitored DPP and instantaneous dose rate of the linac used during the measurements. CONCLUSIONS: The results clearly demonstrate that the developed devices exhibit a dose-rate independent response even under extreme instantaneous dose rates and dose per pulse values. A systematic study of the SiC response was also performed as a function of the applied voltage bias, demonstrating the reliability of these dosimeters with UHDR also without any applied voltage. This demonstrates the great potential of SiC detectors for accurate dosimetry in the context of FLASH-RT.

8.
Front Oncol ; 14: 1369065, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38737902

RESUMEN

Introduction: FLASH proton therapy (FLASH-PT) requires ultra-high dose rate (≥ 40 Gy/s) protons to be delivered in a short timescale whilst conforming to a patient-specific target. This study investigates the feasibility and constraints of Bragg peak FLASH-PT treatment planning, and compares the in silico results produced to plans for intensity modulated proton therapy (IMPT). Materials and method: Bragg peak FLASH-PT and IMPT treatment plans were generated for bone (n=3), brain (n=3), and lung (n=4) targets using the MIROpt research treatment planning system and the Conformal FLASH library developed by Applications SA from the open-source version of UCLouvain. FLASH-PT beams were simulated using monoenergetic spot-scanned protons traversing through a conformal energy modulator, a range shifter, and an aperture. A dose rate constraint of ≥ 40 Gy/s was included in each FLASH-PT plan optimisation. Results: Space limitations in the FLASH-PT adapted beam nozzle imposed a maximum target width constraint, excluding 4 cases from the study. FLASH-PT plans did not satisfy the imposed target dose constraints (D95% ≥ 95% and D2%≤ 105%) but achieved clinically acceptable doses to organs at risk (OARs). IMPT plans adhered to all target and OAR dose constraints. FLASH-PT plans showed a reduction in both target homogeneity (p < 0.001) and dose conformity (non-significant) compared to IMPT. Conclusion: Without accounting for a sparing effect, IMPT plans were superior in target coverage, dose conformity, target homogeneity, and OAR sparing compared to FLASH-PT. Further research is warranted in treatment planning optimisation and beam delivery for clinical implementation of Bragg peak FLASH-PT.

9.
Bioact Mater ; 37: 299-312, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38694765

RESUMEN

Ultrahigh dose-rate (FLASH) radiotherapy is an emerging technology with excellent therapeutic effects and low biological toxicity. However, tumor recurrence largely impede the effectiveness of FLASH therapy. Overcoming tumor recurrence is crucial for practical FLASH applications. Here, we prepared an agarose-based thermosensitive hydrogel containing a mild photothermal agent (TPE-BBT) and a glutaminase inhibitor (CB-839). Within nanoparticles, TPE-BBT exhibits aggregation-induced emission peaked at 900 nm, while the unrestricted molecular motions endow TPE-BBT with a mild photothermy generation ability. The balanced photothermal effect and photoluminescence are ideal for phototheranostics. Upon 660-nm laser irradiation, the temperature-rising effect softens and hydrolyzes the hydrogel to release TPE-BBT and CB-839 into the tumor site for concurrent mild photothermal therapy and chemotherapy, jointly inhibiting homologous recombination repair of DNA. The enhanced FLASH radiotherapy efficiently kills the tumor tissue without recurrence and obvious systematic toxicity. This work deciphers the unrestricted molecular motions in bright organic fluorophores as a source of photothermy, and provides novel recurrence-resistant radiotherapy without adverse side effects.

11.
Med Phys ; 51(7): 5119-5129, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38569159

RESUMEN

BACKGROUND: Dosimetry in pre-clinical FLASH studies is essential for understanding the beam delivery conditions that trigger the FLASH effect. Resolving the spatial and temporal characteristics of proton pencil beam scanning (PBS) irradiations with ultra-high dose rates (UHDR) requires a detector with high spatial and temporal resolution. PURPOSE: To implement a novel camera-based system for time-resolved two-dimensional (2D) monitoring and apply it in vivo during pre-clinical proton PBS mouse irradiations. METHODS: Time-resolved 2D beam monitoring was performed with a scintillation imaging system consisting of a 1 mm thick transparent scintillating sheet, imaged by a CMOS camera. The sheet was placed in a water bath perpendicular to a horizontal PBS proton beam axis. The scintillation light was reflected through a system of mirrors and captured by the camera with 500 frames per second (fps) for UHDR and 4 fps for conventional dose rates. The raw images were background subtracted, geometrically transformed, flat field corrected, and spatially filtered. The system was used for 2D spot and field profile measurements and compared to radiochromic films. Furthermore, spot positions were measured for UHDR irradiations. The measured spot positions were compared to the planned positions and the relative instantaneous dose rate to equivalent fiber-coupled point scintillator measurements. For in vivo application, the scintillating sheet was placed 1 cm upstream the right hind leg of non-anaesthetized mice submerged in the water bath. The mouse leg and sheet were both placed in a 5 cm wide spread-out Bragg peak formed from the mono-energetic proton beam by a 2D range modulator. The mouse leg position within the field was identified for both conventional and FLASH irradiations. For the conventional irradiations, the mouse foot position was tracked throughout the beam delivery, which took place through repainting. For FLASH irradiations, the delivered spot positions and relative instantaneous dose rate were measured. RESULTS: The pixel size was 0.1 mm for all measurements. The spot and field profiles measured with the scintillating sheet agreed with radiochromic films within 0.4 mm. The standard deviation between measured and planned spot positions was 0.26 mm and 0.35 mm in the horizontal and vertical direction, respectively. The measured relative instantaneous dose rate showed a linear relation with the fiber-coupled scintillator measurements. For in vivo use, the leg position within the field varied between mice, and leg movement up to 3 mm was detected during the prolonged conventional irradiations. CONCLUSIONS: The scintillation imaging system allowed for monitoring of UHDR proton PBS delivery in vivo with 0.1 mm pixel size and 2 ms temporal resolution. The feasibility of instantaneous dose rate measurements was demonstrated, and the system was used for validation of the mouse leg position within the field.


Asunto(s)
Terapia de Protones , Conteo por Cintilación , Animales , Ratones , Conteo por Cintilación/instrumentación , Terapia de Protones/instrumentación , Factores de Tiempo , Radiometría/instrumentación , Radiometría/métodos , Dosificación Radioterapéutica , Protones
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 184-191, 2024 Mar 30.
Artículo en Chino | MEDLINE | ID: mdl-38605619

RESUMEN

More than 70% of tumor patients require radiotherapy. Medical electron linear accelerators are important high-end radiotherapy equipment for tumor radiotherapy. With the application of artificial intelligence technology in medical electron linear accelerator, radiotherapy has evolved from ordinary radiotherapy to today's intelligent radiotherapy. This study introduces the development history, working principles and system composition of medical electron linear accelerators. It outlines the key technologies for improving the performance of medical linear electron accelerators, including beam control, multi-leaf collimator, guiding technology and dose evaluation. It also looks forward to the development trend of major radiotherapy technologies, such as biological guided radiotherapy, FLASH radiotherapy and intelligent radiotherapy, which provides references for the development of medical electron linear accelerators.


Asunto(s)
Electrones , Neoplasias , Humanos , Inteligencia Artificial , Aceleradores de Partículas , Dosificación Radioterapéutica
13.
Phys Med Biol ; 69(10)2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38640916

RESUMEN

Objective.Beam current transformers (BCT) are promising detectors for real-time beam monitoring in ultra-high dose rate (UHDR) electron radiotherapy. However, previous studies have reported a significant sensitivity of the BCT signal to changes in source-to-surface distance (SSD), field size, and phantom material which have until now been attributed to the fluctuating levels of electrons backscattered within the BCT. The purpose of this study is to evaluate this hypothesis, with the goal of understanding and mitigating the variations in BCT signal due to changes in irradiation conditions.Approach.Monte Carlo simulations and experimental measurements were conducted with a UHDR-capable intra-operative electron linear accelerator to analyze the impact of backscattered electrons on BCT signal. The potential influence of charge accumulation in media as a mechanism affecting BCT signal perturbation was further investigated by examining the effects of phantom conductivity and electrical grounding. Finally, the effectiveness of Faraday shielding to mitigate BCT signal variations is evaluated.Main Results.Monte Carlo simulations indicated that the fraction of electrons backscattered in water and on the collimator plastic at 6 and 9 MeV is lower than 1%, suggesting that backscattered electrons alone cannot account for the observed BCT signal variations. However, our experimental measurements confirmed previous findings of BCT response variation up to 15% for different field diameters. A significant impact of phantom type on BCT response was also observed, with variations in BCT signal as high as 14.1% when comparing measurements in water and solid water. The introduction of a Faraday shield to our applicators effectively mitigated the dependencies of BCT signal on SSD, field size, and phantom material.Significance.Our results indicate that variations in BCT signal as a function of SSD, field size, and phantom material are likely driven by an electric field originating in dielectric materials exposed to the UHDR electron beam. Strategies such as Faraday shielding were shown to effectively prevent these electric fields from affecting BCT signal, enabling reliable BCT-based electron UHDR beam monitoring.


Asunto(s)
Electrones , Método de Montecarlo , Fantasmas de Imagen , Dispersión de Radiación , Electrones/uso terapéutico , Aceleradores de Partículas , Dosis de Radiación
14.
Int J Mol Sci ; 25(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38473799

RESUMEN

Major strides have been made in the development of FLASH radiotherapy (FLASH RT) in the last ten years, but there are still many obstacles to overcome for transfer to the clinic to become a reality. Although preclinical and first-in-human clinical evidence suggests that ultra-high dose rates (UHDRs) induce a sparing effect in normal tissue without modifying the therapeutic effect on the tumor, successful clinical translation of FLASH-RT depends on a better understanding of the biological mechanisms underpinning the sparing effect. Suitable in vitro studies are required to fully understand the radiobiological mechanisms associated with UHDRs. From a technical point of view, it is also crucial to develop optimal technologies in terms of beam irradiation parameters for producing FLASH conditions. This review provides an overview of the research progress of FLASH RT and discusses the potential challenges to be faced before its clinical application. We critically summarize the preclinical evidence and in vitro studies on DNA damage following UHDR irradiation. We also highlight the ongoing developments of technologies for delivering FLASH-compliant beams, with a focus on laser-driven plasma accelerators suitable for performing basic radiobiological research on the UHDR effects.


Asunto(s)
Daño del ADN , Motivación , Humanos , Cabeza , Plasma , Radiobiología
15.
Radiother Oncol ; 196: 110238, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38527626

RESUMEN

BACKGROUND: FLASH-radiotherapy (FLASH-RT) is an emerging modality that uses ultra-high dose rates of radiation to enable curative doses to the tumor while preserving normal tissue. The biological studies showed the potential of FLASH-RT to revolutionize radiotherapy cancer treatments. However, the complex biological basis of FLASH-RT is not fully known yet. AIM: Within this context, our aim is to get deeper insights into the biomolecular mechanisms underlying FLASH-RT through Fourier Transform Infrared Microspectroscopy (FTIRM). METHODS: C57Bl/6J female mice were whole brain irradiated at 10 Gy with the eRT6-Oriatron system. 10 Gy FLASH-RT was delivered in 1 pulse of 1.8µs and conventional irradiations at 0.1 Gy/s. Brains were sampled and prepared for analysis 24 h post-RT. FTIRM was performed at the MIRAS beamline of ALBA Synchrotron. Infrared raster scanning maps of the whole mice brain sections were collected for each sample condition. Hyperspectral imaging and Principal Component Analysis (PCA) were performed in several regions of the brain. RESULTS: PCA results evidenced a clear separation between conventional and FLASH irradiations in the 1800-950 cm-1 region, with a significant overlap between FLASH and Control groups. An analysis of the loading plots revealed that most of the variance accounting for the separation between groups was associated to modifications in the protein backbone (Amide I). This protein degradation and/or conformational rearrangement was concomitant with nucleic acid fragmentation/condensation. Cluster separation between FLASH and conventional groups was also present in the 3000-2800 cm-1 region, being correlated with changes in the methylene and methyl group concentrations and in the lipid chain length. Specific vibrational features were detected as a function of the brain region. CONCLUSION: This work provided new insights into the biomolecular effects involved in FLASH-RT through FTIRM. Our results showed that beyond nucleic acid investigations, one should take into account other dose-rate responsive molecules such as proteins, as they might be key to understand FLASH effect.


Asunto(s)
Ratones Endogámicos C57BL , Animales , Femenino , Ratones , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Encéfalo/efectos de la radiación , Análisis de Componente Principal , Neoplasias Encefálicas/radioterapia , Dosificación Radioterapéutica
16.
Phys Med ; 120: 103332, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38518627

RESUMEN

As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal. A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines. In addition, respiratory cycle amplitudes were quantified by fluoroscopic acquisitions on a mouse, to ensure organ coverage and to assess the impact of respiration during FLASH-RT using the 4D digital phantom MOBY. Furthermore, beam incidence direction was studied from mice µCBCT and Monte Carlo simulations. Finally,in vivodosimetry with dose-rate independent radiochromic films (OC-1) and their LET dependency were investigated. The immobilization system ensures that the animal is held in a safe and suitable position. The geometrical evaluation of organ coverage, after the addition of the margins around the organs, was satisfactory. Moreover, no measured differences were found between CONV and FLASH beams enabling a single model of the beamline for all planning studies. Finally, the LET-dependency of the OC-1 film was determined and experimentally verified with phantoms, as well as the feasibility of using these filmsin vivoto validate the targeting. The methodology developed ensures accurate and reproducible preclinical irradiations in CONV and FLASH-RT without in-room image guidance in terms of positioning, dose calculation andin vivodosimetry.


Asunto(s)
Terapia de Protones , Radioterapia Conformacional , Humanos , Ratones , Animales , Protones , Terapia de Protones/métodos , Pulmón , Fantasmas de Imagen , Método de Montecarlo , Carmustina , Etopósido , Dosificación Radioterapéutica
17.
Radiat Oncol ; 19(1): 34, 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38475815

RESUMEN

BACKGROUND: FLASH therapy is a treatment technique in which radiation is delivered at ultra-high dose rates (≥ 40 Gy/s). The first-in-human FAST-01 clinical trial demonstrated the clinical feasibility of proton FLASH in the treatment of extremity bone metastases. The objectives of this investigation are to assess the toxicities of treatment and pain relief in study participants with painful thoracic bone metastases treated with FLASH radiotherapy, as well as workflow metrics in a clinical setting. METHODS: This single-arm clinical trial is being conducted under an FDA investigational device exemption (IDE) approved for 10 patients with 1-3 painful bone metastases in the thorax, excluding bone metastases in the spine. Treatment will be 8 Gy in a single fraction administered at ≥ 40 Gy/s on a FLASH-enabled proton therapy system delivering a single transmission proton beam. Primary study endpoints are efficacy (pain relief) and safety. Patient questionnaires evaluating pain flare at the treatment site will be completed for 10 consecutive days post-RT. Pain response and adverse events (AEs) will be evaluated on the day of treatment and on day 7, day 15, months 1, 2, 3, 6, 9, and 12, and every 6 months thereafter. The outcomes for clinical workflow feasibility are the occurrence of any device issues as well as time on the treatment table. DISCUSSION: This prospective clinical trial will provide clinical data for evaluating the efficacy and safety of proton FLASH for palliation of bony metastases in the thorax. Positive findings will support the further exploration of FLASH radiation for other clinical indications including patient populations treated with curative intent. REGISTRATION: ClinicalTrials.gov NCT05524064.


Asunto(s)
Neoplasias Óseas , Protones , Humanos , Neoplasias Óseas/radioterapia , Dolor , Estudios Prospectivos , Tórax
18.
Phys Med Biol ; 69(9)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38530300

RESUMEN

Objective.The successful implementation of FLASH radiotherapy in clinical settings, with typical dose rates >40 Gy s-1, requires accurate real-time dosimetry.Approach.Silicon carbide (SiC) p-n diode dosimeters designed for the stringent requirements of FLASH radiotherapy have been fabricated and characterized in an ultra-high pulse dose rate electron beam. The circular SiC PiN diodes were fabricated at IMB-CNM (CSIC) in 3µm epitaxial 4H-SiC. Their characterization was performed in PTB's ultra-high pulse dose rate reference electron beam. The SiC diode was operated without external bias voltage. The linearity of the diode response was investigated up to doses per pulse (DPP) of 11 Gy and pulse durations ranging from 3 to 0.5µs. Percentage depth dose measurements were performed in ultra-high dose per pulse conditions. The effect of the total accumulated dose of 20 MeV electrons in the SiC diode sensitivity was evaluated. The temperature dependence of the response of the SiC diode was measured in the range 19 °C-38 °C. The temporal response of the diode was compared to the time-resolved beam current during each electron beam pulse. A diamond prototype detector (flashDiamond) and Alanine measurements were used for reference dosimetry.Main results.The SiC diode response was independent both of DPP and of pulse dose rate up to at least 11 Gy per pulse and 4 MGy s-1, respectively, with tolerable deviation for relative dosimetry (<3%). When measuring the percentage depth dose under ultra-high dose rate conditions, the SiC diode performed comparably well to the reference flashDiamond. The sensitivity reduction after 100 kGy accumulated dose was <2%. The SiC diode was able to follow the temporal structure of the 20 MeV electron beam even for irregular pulse estructures. The measured temperature coefficient was (-0.079 ± 0.005)%/°C.Significance.The results of this study demonstrate for the first time the suitability of silicon carbide diodes for relative dosimetry in ultra-high dose rate pulsed electron beams up to a DPP of 11 Gy per pulse.


Asunto(s)
Compuestos Inorgánicos de Carbono , Dosímetros de Radiación , Radiometría , Radiometría/métodos , Compuestos de Silicona , Electrones
19.
Clin Transl Radiat Oncol ; 45: 100743, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38362466

RESUMEN

Background: Cutaneous basal cell carcinoma (BCC) and squamous cell carcinoma (SCC) are the most prevalent skin cancers in western countries. Surgery is the standard of care for these cancers and conventional external radiotherapy (CONV-RT) with conventional dose rate (0.03-0.06 Gy/sec) represents a good alternative when the patients or tumors are not amenable to surgery but routinely generates skin side effects. Low energy electron FLASH radiotherapy (FLASH-RT) is a new form of radiotherapy exploiting the biological advantage of the FLASH effect, which consists in delivering radiation dose in milliseconds instead of minutes in CONV-RT. In pre-clinical studies, when compared to CONV-RT, FLASH-RT induced a robust, reproducible and remarkable sparing of the normal healthy tissues, while the efficacy on tumors was preserved. In this context, we aim to prospectively evaluate FLASH-RT versus CONV-RT with regards to toxicity and oncological outcome in localized cutaneous BCC and SCC. Methods: This is a randomized selection, non-comparative, phase II study of curative FLASH-RT versus CONV-RT in patients with T1-T2 N0 M0 cutaneous BCC and SCC. Patients will be randomly allocated to low energy electron FLASH-RT (dose rate: 220-270 Gy/s) or to CONV-RT arm. Small lesions (T1) will receive a single dose of 22 Gy and large lesions (T2) will receive 30 Gy in 5 fractions of 6 Gy over two weeks.The primary endpoint evaluates safety at 6 weeks after RT through grade ≥ 3 toxicity and efficacy through local control rate at 12 months. Approximately 60 patients in total will be randomized, considering on average 1-2 lesions and a maximum of 3 lesions per patients corresponding to the total of 96 lesions required. FLASH-RT will be performed using the Mobetron® (IntraOp, USA) with high dose rate functionality.LANCE (NCT05724875) is the first randomized trial evaluating FLASH-RT and CONV-RT in a curative setting.

20.
Small ; 20(29): e2400666, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38368259

RESUMEN

Compared to conventional radiotherapy (RT), FLASH-RT delivers ultra-high dose radiation, significantly reducing damage to normal tissue while guaranteeing the effect of cancer treatment. However, cancer recurrence and metastasis frequently occur after all RT due to the existence of intractable cancer stem cells (CSCs). To address this, a biomimetic nanoplatform (named TAFL) of tumor-derived exosome fusion liposomes is designed by co-loading aggregation-induced emission photothermal agents, TPE-BBT, and anti-cancer drugs, aspirin, aiming to clear CSCs for inhibiting cancer recurrence and metastasis after FLASH-RT therapy . Aspirin released in TAFL system triggered by laser irradiation can induce apoptosis and DNA damage of 4T1 CSCs, comprehensively downregulate their stemness phenotype, and inhibit their sphericity. Furthermore, the TPE-BBT mediated mild-photothermal therapy can alleviate the hypoxic tumor microenvironment, inhibit the DNA repair of CSCs, which further amplifies the effect of aspirin against CSCs, therefore reduces the effective dose of aspirin, making TAFL more biologically safe. In vivo experimental results demonstrated that decreased CSCs population mediated by TAFL system treatment significantly inhibited tumor recurrence and metastasis after FLASH-RT therapy. In summary, this TAFL system   provides a new idea for the future clinical application of FLASH-RT therapy.


Asunto(s)
Aspirina , Neoplasias de la Mama , Metástasis de la Neoplasia , Células Madre Neoplásicas , Células Madre Neoplásicas/efectos de los fármacos , Células Madre Neoplásicas/patología , Neoplasias de la Mama/patología , Neoplasias de la Mama/tratamiento farmacológico , Animales , Femenino , Aspirina/farmacología , Aspirina/uso terapéutico , Línea Celular Tumoral , Recurrencia Local de Neoplasia , Ratones , Humanos , Daño del ADN , Microambiente Tumoral/efectos de los fármacos , Liposomas/química , Apoptosis/efectos de los fármacos , Biomimética/métodos , Materiales Biomiméticos/química , Materiales Biomiméticos/farmacología , Exosomas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA