World J Urol ; 42(1): 298, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709327

RESUMEN

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Asunto(s)
Diseño de Equipo , Riñón , Iluminación , Ureteroscopios , Modelos Anatómicos , Humanos
3.
World J Urol ; 42(1): 294, 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38704777

RESUMEN

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Asunto(s)
Ureteroscopios , Ureteroscopía , Humanos , Diseño de Equipo , Iluminación , Docilidad , Cálices Renales
4.
J Clin Med ; 13(9)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38731026

RESUMEN

New suction endoscopes, ureteral access sheaths (UAS) and catheters aim to improve the efficacy of flexible ureteroscopy and optimize its safety. Suction UAS with non-flexible tips have shown promising results, especially in maintaining low intrarenal pressure, but also in removing small debris and reducing the "snow globe" effect. In addition, suctioning UAS with a flexible tip offers the advantage of being able to be navigated through the pyelocaliceal system to where the laser lithotripsy is performed. It can also remove small stone fragments when the flexible ureteroscope is retracted, using the Venturi effect. Direct in-scope suction (DISS) involves aspirating dust and small stone debris through the working channel of a flexible ureteroscope, thus regulating intrarenal pressure and improving visibility. Steerable aspiration catheters are other devices designed to increase stone clearance of the pyelocaliceal system. They are inserted under fluoroscopic guidance into every calyx after retraction of the flexible ureteroscope, alternating irrigation and aspiration to remove dust and small gravels. Combining flexible-tip suction UAS and the DISS technique may offer some advantages worth evaluating. The advantage of using these instruments to achieve a low intrarenal pressure was demonstrated. The true practical impact on the long-term stone-free status is a matter requiring further studies.

5.
Actas urol. esp ; 48(3): 204-209, abr. 2024. tab
Artículo en Español | IBECS | ID: ibc-231925

RESUMEN

Objetivos Este estudio evalúa el impacto del uso de una vaina de acceso ureteral (VAU) durante la ureteroscopia flexible (URSf) para el tratamiento de la litiasis urinaria, centrándose en resultados como la tasa libre de litiasis, el tiempo quirúrgico y las complicaciones. Métodos Este estudio prospectivo y aleatorizado se llevó a cabo en el Hospital de Badr en la Universidad de Helwan y en los hospitales de la Universidad de Ain Shams, desde agosto de 2021 hasta agosto de 2022. Los pacientes se aleatorizaron sistemáticamente a 2 grupos (URSf con VAU: 33 pacientes y URSf sin VAU: 31 pacientes), y se sometieron a evaluaciones preoperatorias y postoperatorias, incluyendo pruebas de laboratorio y de imagen. Se controlaron los posibles riesgos asociados al procedimiento, como el fracaso en el acceso al cálculo, el dolor, el sangrado y la sepsis. Resultados Se observó que los 2 grupos eran comparables en cuanto a características demográficas o hallazgos preoperatorios de la litiasis (p>0,05 para todos). Sin embargo, el tiempo quirúrgico fue menor en el grupo tratado sin VAU (79,4±15,3 vs. 90,4±16,7min en el grupo tratado con VAU; p=0,008). Las tasas de complicaciones intraoperatorias, incluidos el fracaso del acceso, la interrupción de la operación, las lesiones ureterales y el sangrado, fueron comparables en ambos grupos (p>0,05). No se observaron diferencias significativas en cuanto a la tasa libre de litiasis postoperatoria (78,8 vs. 71,0%; p=0,305) y el tamaño litiásico residual medio (2,7±3,5 vs. 3,1±3,1mm; p=0,687). Conclusiones El presente estudio sugiere que URSf sin VAU puede ofrecer una opción eficiente e igualmente efectiva para el tratamiento de los cálculos renales y de uréter superior. Sin embargo, se necesitan más estudios con muestras de mayor tamaño y periodos de seguimiento más largos para validar estos resultados y establecer indicaciones más precisas para este procedimiento. (AU)


Objectives This study evaluates the impact of using an access sheath (AS) during flexible ureteroscopy (fURS) for urolithiasis treatment, focusing on outcomes such as stone-free rate, operation time, and complications. Methods This prospective, randomized study was carried out at Badr Hospital, Helwan University, and Ain Shams University hospitals from August 2021 to August 2022. Patients were systematically randomized into two groups (fURS with AS: 33 patients and without AS: 31 patients) and underwent preoperative and postoperative assessments, including lab tests and imaging. Possible procedure-associated risks, such as failed stone access, pain, bleeding, and sepsis, were monitored. Results The two groups were found to be comparable in terms of demographic characteristics or preoperative stone findings (P>.05 for all). However, operation duration was shorter in the No Sheath group (79.4±15.3minutes vs. 90.4±16.7minutes in the Sheath group, P=.008). Intraoperative complication rates, including failed access, operation termination, ureteric injury, and bleeding, were comparable in both groups (P>.05). Postoperative stone-free rates (78.8% vs. 71.0%, P=.305) and mean residual stone size (2.7±3.5mm vs. 3.1±3.1mm, P=.687) showed no significant differences. Conclusions The present study suggests that fURS without an access sheath may offer an efficient and equally effective option for managing upper ureteric and renal stones. However, more studies with larger sample sizes and longer follow-up periods are required to validate these findings and to establish more precise indications for this approach. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Ureteroscopía/instrumentación , Ureteroscopía/métodos , Urolitiasis/cirugía
7.
World J Urol ; 42(1): 233, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38613608

RESUMEN

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Asunto(s)
Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Holmio , Tulio , Ureteroscopía , Estudios Prospectivos , Cálculos Renales/cirugía , Rayos Láser
8.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-38520528

RESUMEN

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Asunto(s)
Iluminación , Ureteroscopios , Humanos , Diseño de Equipo , Urólogos , Equipos Desechables , Ureteroscopía
9.
BMC Urol ; 24(1): 70, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38532342

RESUMEN

BACKGROUND: Ureteropelvic junction obstruction (UPJO) is a common obstructive disease of the urinary tract. UPJO patients commonly exhibit coexistent renal calculi. The main aim of therapy is to relieve the obstruction and remove the stones at the same time. METHODS: This retrospective study included 110 patients diagnosed with UPJO coexisting with multiple renal calculi at Shanxi Bethune Hospital and the First Hospital of Shanxi Medical University between March 2016 and January 2022. Patients were divided according to the methods used for dealing with UPJO and renal calculi. In Group A, patients underwent traditional open pyeloplasty and pyelolithotomy. In Group B, patients underwent percutaneous nephrolithotomy first and then laparoscopic pyeloplasty. In Group C, patients underwent flexible cystoscopy to remove stones and then laparoscopic pyeloplasty. In Group D, patients underwent flexible vacuum-assisted ureteral access sheath (FV-UAS)assisted flexible ureteroscopy (f-URS) and underwent laparoscopic pyeloplasty. The stones were broken up using a holmium laser. The pyeloplasty success rate, stone clearance rate, operation time, bleeding amount, complication occurrence rate, postsurgical pain, length of stay, and hospitalization cost were compared between the groups. The follow-up period was at least 2 years. RESULTS: The use of f-URS and the FV-UAS, significantly increased the renal stone clearance rate and significantly reduced the complication incidence and operation time in UPJO patients with multiple coexisting renal calculi. CONCLUSIONS: Laparoscopic pyeloplasty combined with f-URS and FV-UAS is safe and effective for treating UPJO in patients complicated by renal caliceal stones. TRIAL REGISTRATION: Retrospectively registered.


Asunto(s)
Cálculos Renales , Laparoscopía , Cálculos Ureterales , Obstrucción Ureteral , Humanos , Ureteroscopía/efectos adversos , Estudios Retrospectivos , Pelvis Renal/cirugía , Laparoscopía/métodos , Obstrucción Ureteral/cirugía , Cálculos Renales/cirugía , Resultado del Tratamiento , Cálculos Ureterales/cirugía
10.
J Endourol ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38468539

RESUMEN

Introduction: Retrograde intrarenal surgery (RIRS) is associated with complications, many of which are related to the intrarenal pressure (IRP). We aim to describe the design of a novel isoprenaline-eluting guidewire ("IsoWire") and present the results from the first in vitro release studies and the first animal studies showing its effect on IRP. Materials and Methods: The IsoWire comprises a Nitinol core surrounded by a stainless-steel wire wound into a tight coil. The grooves created by this coil provided a reservoir for adding a hydrogel coating into which isoprenaline, a beta-agonist, was loaded. Animal studies were performed using a porcine model. For the control, IRP, heart rate (HR), and mean arterial pressure (MAP) were measured continuously for 6 minutes with a standard guidewire in place. For the experiment, the standard hydrophilic guidewire was removed, the IsoWire was inserted into the renal pelvis, and the same parameters were measured. Results: In vitro analysis of the isoprenaline release profile showed that most (63.9 ± 5.9%) of the loaded drug mass was released in the 1st minute, and almost all of the drug was released in the first 4 minutes exponentially. Porcine studies showed a 25.1% reduction in IRP in the IsoWire that released 10 µg in the 1st minute; however, there was a marked increase in HR. The average percentage reduction in IRP was 8.95% and 21.3% in the IsoWire that released 5 and 7.5 µg of isoprenaline, respectively, with no changes in HR or MAP. Conclusions: The IsoWire, which releases 5 and 7.5 µg of isoprenaline in the 1st minute, appears to be safe and effective in reducing the IRP. Further studies are needed to establish whether the isoprenaline-induced ureteral relaxation will render easier insertion of a ureteral access sheath, reduce IRP during sheathless RIRS, or even promote the practice of sheathless RIRS.

11.
J Robot Surg ; 18(1): 128, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38492131

RESUMEN

Robotic flexible ureteroscopy (RFURS) has shown encouraging results in terms of stone free rate (SFR) and better ergonomics compared to conventional FURS. However, few studies have reported its outcomes. The goal of this study was to report our initial results of RFURS, furthermore we proposed a novel metrics for composite outcome reporting named tetrafecta. A retrospective analysis of electronic records of 100 patients treated with RFURS for renal stones between 2019 till 2023 was performed. Tetrafecta criteria included, complete stone removal after a single treatment session, without auxiliary procedures, absence of high-grade complications (GIII-V) and same-day hospital discharge. Mean patient age and stone size were 40.7 ± 9.2 and 11.7 ± 5.8 mm, respectively. Median stone volume was 916 (421-12,235) mm3. Twenty-eight patients had multiple renal stones. Staghorn stones were seen in 12 patients. Preoperative DJ stent was fixed in 58 patients. Median operative time and stone treatment time were 116 min (97-148) and 37 (22-69) min. The median stone treatment efficiency (STE) was 21.6 (8.9-41.6). A strong positive correlation between stone volume and STE (R = 0.8, p < 0.0001). Overall, 73 patients were stone free after the initial treatment session while tetrafecta was achieved in 70 patients. Univariate analysis showed that the stone size (p = 0.008), acute infundibulopelvic angle (p = 0.023) and preoperative stenting (p = 0.017) had significant influence on achieving tetrafecta. Multivariate analysis identified preoperative stenting (OR 0.3, 95% CI 0.1-0.8, p = 0.019) as the only independent predictor of tetrafecta achievement. A comprehensive reporting methodology for reporting outcomes of RFURS is indicated for patient counseling and comparing different techniques. Tetrafecta was achieved in 70% of cases. Presence of significant residual stones ≥ 3mm was the leading cause of missing tetrafecta. Absence of preoperative stent was the only predictor of missing tetrafecta.


Asunto(s)
Cálculos Renales , Procedimientos Quirúrgicos Robotizados , Humanos , Ureteroscopía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Cálculos Renales/cirugía
12.
World J Urol ; 42(1): 130, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38460016

RESUMEN

OBJECTIVE: To explore the parameters influencing intraoperative calculi excretion (ICE) during flexible ureteroscopy lithotripsy (fURL) using in vitro simulation experiments. METHODS: 3D-printed human kidney models were used to simulate the elimination of gravel during fURL. The factors influencing the ICE during fURL were analyzed by comparing the effects of different degrees of hydronephrosis (mild, moderate, and severe), surgical positions (supine and lateral position), ratios of endoscope-sheath diameter (RESD) (0.625, 0.725, and 0.825), gravel sizes (0.50-1.00 mm, 0.25-0.50 mm, and 0.10-0.25 mm), and ureteral access sheaths (UASs) (traditional UAS and negative-pressure UAS) on ICE. RESULTS: The impacts of various UAS, RESD, degree of hydronephrosis, surgical positions, and gravel sizes on ICE were all significant (p < 0.05). We found no evidence of multicollinearity for all the independent variables, and the linear regression equation fitted as ICE ( g / min ) = 0.102 + 0.083 ∗ UAS grade - 0.050 ∗ RESD grade - 0.048 ∗ hydronephrosis grade + 0.065 ∗ position grade - 0.027 ∗ gravel size grade (R2 = 0.569). CONCLUSION: Employing negative-pressure UAS, smaller RESD, milder hydronephrosis, lateral position, and smaller gravel size contribute to improved ICE during fURL. Among them, the adoption of negative-pressure UAS had the most substantial effects.


Asunto(s)
Hidronefrosis , Cálculos Renales , Litotricia , Cálculos Ureterales , Humanos , Ureteroscopía , Cálculos Renales/cirugía , Ureteroscopios , Cálculos Ureterales/cirugía
13.
World J Urol ; 42(1): 122, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38453696

RESUMEN

PURPOSE: To maintain safe intrarenal pelvic pressure (IPP), the combination of flexible ureteroscope (fURS) and traditional ureteral access sheath (T-UAS) should maintain a basic rule that is the ratio of endoscope-sheath diameter (RESD) ≤ 0.75. However, the negative-pressure ureteral access sheath (NP-UAS) may break the rule of negative pressure suction. This study aimed to examine the effect of NP-UAS on IPP and flow rate (FR) with varying RESD. METHODS: In a 3D-printed renal model, flexible ureteroscopy lithotripsy (fURL) was replicated. Six sizes of fURS paired with 12Fr T-UAS and NP-UAS resulted in six distinct RESDs of 0.63, 0.78, 0.87, 0.89, 0.90, and 0.91. While the irrigation pressure (IRP) was set between 100 and 800 cmH2O and the sucking pressure (SP) was set between 0 and 800 cmH2O, the IPP and FR were measured in each RESD. RESULTS: NP-UASs can reduce the IPP and increase the FR at the same RESD compared to T-UASs. The IPP decreased with increasing SP with NP-UAS. When RESD ≤ 0.78, T-UAS and NP-UAS can maintain IPP < 40 cmH2O in most circumstances. When RESD = 0.87, it is challenging for T-UAS to sustain IPP < 40 cmH2O; however, NP-UAS can do so. When RESD ≥ 0.89, it is difficult to maintain an IPP < 40 cmH2O even with NP-UAS. CONCLUSION: NP-UAS can decrease IPP and increase FR compared with T-UAS. To maintain a safe IPP, it is recommended that RESD < 0.85 when utilizing NP-UAS.


Asunto(s)
Cálculos Renales , Uréter , Humanos , Ureteroscopía/métodos , Riñón , Ureteroscopios
15.
Urolithiasis ; 52(1): 33, 2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38340170

RESUMEN

The aim is to compare the efficacy and safety between single percutaneous nephrolithotomy (sPNL) and antegrade flexible ureteroscopy-assisted percutaneous nephrolithotomy (aPNL) for the treatment of staghorn calculi. A prospective randomized controlled study was conducted at the Second Hospital of Tianjin Medical University. A total of 160 eligible patients were included, with 81 in the sPNL group and 79 in the aPNL group. The study first compared the overall differences between sPNL and aPNL. Then, the patients were divided into two subgroups: Group 1 (with less than 5 stone branches) and Group 2 (with 5 or more stone branches), and the differences between the two subgroups were further analyzed. The results showed that aPNL had a higher stone-free rate (SFR) and required fewer percutaneous tracts, with a shorter operation time compared to sPNL (P < 0.05). Moreover, aPNL significantly reduced the need for staged surgery, particularly in patients with 5 or more stone branches. Moreover, there were no significant differences in the changes of hemoglobin levels and the need for blood transfusions between the sPNL and aPNL groups, and the incidence of multiple tracts was lower in the aPNL group. The two groups showed comparable rates of perioperative complications. We concluded that aPNL resulted in a higher SFR for staghorn calculi, and required fewer multiple percutaneous tracts, reduced the need for staged surgery, and had a shorter operative time than PNL alone, especially for patients with 5 or more stone branches. Furthermore, aPNL did not increase the incidence of surgical complications.


Asunto(s)
Cálculos Renales , Nefrolitotomía Percutánea , Nefrostomía Percutánea , Cálculos Coraliformes , Humanos , Cálculos Coraliformes/cirugía , Nefrolitotomía Percutánea/efectos adversos , Nefrolitotomía Percutánea/métodos , Ureteroscopía/efectos adversos , Ureteroscopía/métodos , Estudios Prospectivos , Resultado del Tratamiento , Cálculos Renales/cirugía , Nefrostomía Percutánea/efectos adversos , Nefrostomía Percutánea/métodos , Estudios Retrospectivos
16.
Transl Androl Urol ; 13(1): 185-191, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38404560

RESUMEN

Background: Percutaneous nephrolithotomy (PCNL) is the first-line treatment for large renal stones. However, multi-tract or staged procedures may be necessitated in bilateral or anatomically-complex stones to achieve stone clearance. Endoscopic combined intrarenal surgery (ECIRS) integrates the advantages of PCNL and retrograde intrarenal surgery. In this article, we detail a hybrid surgical technique adopted for the management of complex simultaneous bilateral upper urinary tract stones. In addition, we discuss the advantages and disadvantages of combining a variety of new techniques that may improve post-operative outcomes and patient satisfaction. Case Description: We report the case of a 36-year-old male with a large left renal pelvis stone, right proximal ureteric stone, and bilateral renal stones. Biochemical results showed raised inflammatory markers but he denied pre-stenting and staged surgery. After receiving 3-day antibiotic prophylaxis, he underwent an elective hybrid procedure. Under split-leg prone position, we performed a hybrid procedure that included left ECIRS with tubeless single-tract mini PCNL and left flexible ureteroscopy, and right flexible ureteroscopic lithotripsy. Hemostasis was achieved by electrocauterization with a novel device. The patient made an uneventful recovery. Follow-up computed tomography (CT) at 1-month revealed complete stone clearance. Conclusions: Unilateral ECIRS with tubeless single-tract mini PCNL with electrocoagulation hemostasis and adjacent retrograde intrarenal surgery in split-leg prone position is a safe, feasible, and efficient technique to manage large renal stones.

17.
Urol Case Rep ; 53: 102663, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38312135

RESUMEN

The occurrence of a large ureteric calculus in a transplanted kidney, originating from a donor, is a rare but significant complication. It poses risks such as urinary obstruction, septicemia, and potential loss of allograft function. In this case, we report our first use of the direct in-scope suction technique during antegrade flexible ureteroscopy lithotripsy. This method successfully removed a donor-derived ureteric calculus in a kidney transplant recipient. The procedure resulted in complete stone removal, and the patient experienced a favorable postoperative recovery without additional adverse events.

18.
BMC Urol ; 24(1): 39, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355516

RESUMEN

BACKGROUND: This retrospective study was conducted to compare the safety and efficacy of Sun's tip-flexible semirigid ureterorenoscopy (tf-URS), super-mini percutaneous nephrolithotomy (SMP) and flexible ureteroscopy (FURS) in treating upper urinary tract calculi, including upper ureteral or renal calculi. METHODS: We included patients with upper ureteral calculi or renal calculi 1.0-2.0 cm in size, who underwent tf-URS, SMP or FURS, respectively. The indicators reflecting safety and efficacy were compared among the three surgical techniques. RESULTS: SMP presented with higher single stone crushing success rate, but longer operation time and postoperative hospital stay, more blood loss, and higher postoperative pain score compared with FURS and tf-URS (P < 0.05). The hospitalization cost of tf-URS group was lower than that of SMP and FURS groups (P < 0.05). The incidence of postoperative fever in tf-URS group was significantly higher than that in SMP group (P < 0.05). No significant difference was found in mucosal injury, perirenal hematoma, and stone-free rate at 3 months after surgery (P > 0.05). CONCLUSIONS: tf-URS and FURS have the advantages in minimal invasion, hospitalization cost, patient comfort, and hospital stay while SMP has higher stone-free rate. These three surgical techniques are safe, reliable and complementary, which should be selected according to the actual situation.


Asunto(s)
Cálculos Renales , Nefrolitotomía Percutánea , Uréter , Humanos , Ureteroscopía/métodos , Estudios Retrospectivos , Nefrolitotomía Percutánea/métodos , Resultado del Tratamiento , Cálculos Renales/cirugía , Hemorragia Gastrointestinal
19.
Artículo en Inglés | MEDLINE | ID: mdl-38364181

RESUMEN

Background: During percutaneous nephrolithotomy (PCNL), accessibility to the entire collecting system is crucial to check the presence of any residual stone fragments. In this study, we aimed to identify the rate of accessibility of all caliceal cavities using lower-, middle- and, upper-pole punctures and the eventual benefit of simultaneous utilization of retrograde/antegrade flexible nephroscopy. Materials and Methods: Data of patients undergone supine PCNL in five different institutions were collected prospectively. Access status to other poles of the kidney with a rigid nephroscope, antegrade access status to the other poles of the kidney with a flexible nephroscope, or retrograde access with a flexible ureterorenoscope were all evaluated together with detection of residual fragments. Access status to the other poles of the kidney with anterograde and retrograde approaches were compared. Results: Data of 226 patients were analyzed and stone-free status was achieved in 207 (91.6%) of the patients. The entire collecting system could be successfully approached by a rigid nephroscope in 50% of the cases through middle-pole puncture. This rate was significantly higher than that of lower-pole puncture (37.1%) and upper-pole puncture (28.1%) (P = .035). The successful approach to the entire collecting system with retrograde ureterorenoscopy was possible in 97.6% of the cases, while the successful approach was possible in 48 of the 60 cases (80%) with the retrograde approach (P < .0001). Conclusions: During PCNL, evaluation of the entire collecting system with rigid nephroscopy is not possible in a significant portion of the patients. We believe that the application of flexible nephroscopy, particularly via retrograde approach improves the stone-free rates.

20.
Urolithiasis ; 52(1): 30, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38329544

RESUMEN

To evaluate the necessity of confirmation for a negative urine culture test outcome after an appropriate antibiotic regimen for urinary tract infection (UTI) prior to endoscopic stone removal procedures. 170 cases receiving an appropriate antibiotic treatment for culture proven UTI based on test outcomes before endoscopic stone removal were evaluated in two groups: Group 1 (n = 85) Patients in whom a second urine culture test was performed to ensure "negative urine culture" status prior to the procedures after receiving antibiotic therapy and Group 2 (n = 85). Patients receiving the same antibiotic therapy without any additional urine culture test before the procedures. Cases were comparatively evaluated with respect to the statistical significance of post-operative infective complications (fever, sepsis), duration of hospital stay and readmission rates during early post-operative period. Our findings demonstrated no significant difference regarding the rate of infective complications (presence of fever, incidence of septic findings), hospitalization period and readmission rates between the two groups. Although the presence of a negative urine status has been confirmed by urine culture test in group 1 cases, no additional urine culture test was performed with this aim in group 2 cases (negative urine culture was confirmed only with urinalysis) and the outcomes regarding the infective problems were found to be similiar. Our current findings indicate that a second urine culture test may not be a "must" if the patients receive an appropriate antibiotic regimen based on the sensitivity test outcomes for a reasonable time period.


Asunto(s)
Cálculos Renales , Infecciones Urinarias , Humanos , Antibacterianos/uso terapéutico , Urinálisis , Infecciones Urinarias/tratamiento farmacológico , Infecciones Urinarias/epidemiología , Infecciones Urinarias/etiología , Cálculos Renales/cirugía , Complicaciones Posoperatorias , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS